Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser-driven x-ray and proton micro-source and application to simultaneous single-shot bi-modal radiographic imaging

Radiographic imaging with x-rays and protons is an omnipresent tool in basic research and applications in industry, material science and medical diagnostics. The information contained in both modalities can often be valuable in principle, but difficult to access simultaneously. Laser-driven solid-density plasma-sources deliver both kinds of radiation, but mostly single modalities have been explored for applications. Their potential for bi-modal radiographic imaging has never been fully realized, due to problems in generating appropriate sources and separating image modalities. Here, we report on the generation of proton and x-ray micro-sources in laser-plasma interactions of the focused Texas Petawatt laser with solid-density, micrometer-sized tungsten needles. We apply them for bi-modal radiographic imaging of biological and technological objects in a single laser shot. Thereby, advantages of laser-driven sources could be enriched beyond their small footprint by embracing their additional unique properties, including the spectral bandwidth, small source size and multi-mode emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images

Purpose: To estimate attenuation using cross sectional CT images and scanned projection radiograph (SPR) images in a series of thorax and abdomen phantoms. Methods: Attenuation was quantified in terms of a water cylinder with cross sectional area of A{sub w} from both the CT and SPR images of abdomen and thorax phantoms, where A{sub w} is the area of a water cylinder that would absorb the same dose as the specified phantom. SPR and axial CT images were acquired using a dual-source CT scanner operated at 120 kV in single-source mode. To use the SPR image for estimating A{sub w}, the pixel values of a SPR image were calibrated to physical water attenuation using a series of water phantoms. A{sub w} and the corresponding diameter D{sub w} were calculated using the derived attenuation-based methods (from either CT or SPR image). A{sub w} was also calculated using only geometrical dimensions of the phantoms (anterior-posterior and lateral dimensions or cross sectional area). Results: For abdomen phantoms, the geometry-based and attenuation-based methods gave similar results for D{sub w}. Using only geometric parameters, an overestimation of D{sub w} ranging from 4.3% to 21.5% was found for thorax phantoms. Results for D{sub w} using the CT image and SPR based methods agreed with each other within 4% on average in both thorax and abdomen phantoms. Conclusions: Either the cross sectional CT or SPR images can be used to estimate patient attenuation in CT. Both are more accurate than use of only geometrical information for the task of quantifying patient attenuation. The SPR based method requires calibration of SPR pixel values to physical water attenuation and this calibration would be best performed by the scanner manufacturer.

60 APPLIED LIFE SCIENCES↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Application of Perona Malik anisotropic diffusion on digital radiographic image

Perona Malik Anisotropic Diffusion (PMAD) is a very useful and efficient denoising technique if the parameters are properly selected. Overestimating the parameters may cause oversmoothed and underestimating it may leave unfiltered noise. This makes the selection of parameters a crucial process. In this paper the PMAD model is solved using a finite difference scheme The discretized model is evaluated using different diffusion coefficient of exponential and quadratic on defective radiographic images in terms of quality and efficiency. In the application of the PMAD model on image data, a set of defective radiographic images of welding is used as input data. Peak Signal to Noise Ratio (PSNR), Structural Similarity Measure (SSIM) and temporal time are used to evaluate the performance of the model. The implementation of the experiment has been carried out using MATLAB R2009a. In terms of quality, results show that the Quadratic Diffusion Coefficient Function (QDCF) provides better results compared with the Exponential Diffusion Coefficient Function (EDCF). In conclusion, the denoising effect using PMAD model based on finite difference scheme shows able to improve image quality by removing noise in the defective radiographic image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus ‘super-resolution’). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

47 OTHER INSTRUMENTATION↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus $super$-$resolution$). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting a mixing parameter from 2D radiographic imaging of variable-density turbulent flow

We extract a suitably averaged fluctuating density from the two-dimensional radiographic image of a flow. The X-ray attenuation is given by the Beer–Lambert law which exponentially damps the incident beam intensity by a factor proportional to the density, opacity and thickness of the target. By making reasonable assumptions for the mean density, opacity and effective thickness of the target flow, we estimate the density fluctuation contribution to the attenuation. The extracted density fluctuations averaged across the thickness of the flow in the direction of the beam may be used to form the density–specific-volume correlation $b$. In a statistical description of variable-density turbulence, $b$ quantifies the degree of mixedness. The ability to extract a measure of mixedness from experimental data would be a powerful tool that could be used in the validation of mix models. The scheme proposed is tested for DNS data computed for variable density buoyancy-driven mixing. We quantify the deficits in the extracted value of $b$ due to target thickness, Atwood number and modeled signal noise. This analysis justifies using the proposed scheme to infer the mix parameter from thin targets at moderate to low Atwood numbers. Furthermore, to illustrate how the scheme might be used in a practical problem, we demonstrate its application to a radiographic image of counter-shear flow obtained from experiments at the National Ignition Facility.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the quality of radiographic images acquired with point-like gamma-ray sources through correction of the beam divergence and attenuation

Radiographic images acquired with point-like gamma-ray sources exhibit a desirable low penumbra effects specially when positioned far away from the set object-detector. Such an arrangement frequently is not affordable due to the limited flux provided by a distant source. A closer source, however, has two main drawbacks, namely the degradation of the spatial resolution - as actual sources are only approximately punctual - and the non-homogeneity of the beam hitting the detector, which creates a false attenuation map of the object being inspected. This non-homogeneity is caused by the beam divergence itself and by the different thicknesses traversed the beam even if the object were an homogeneous flat plate. In this work, radiographic images of objects with different geometries, such as flat plates and pipes have undergone a correction of beam divergence and attenuation addressing the experimental verification of the capability and soundness of an algorithm formerly developed to generate and process synthetic images. The impact of other parameters, including source-detector gap, attenuation coefficient, ratio defective-to-main hull thickness and counting statistics have been assessed for specifically tailored test-objects aiming at the evaluation of the ability of the proposed method to deal with different boundary conditions. All experiments have been carried out with an X-ray sensitive Imaging Plate and reactor-produced {sup 198}Au and {sup 165}Dy sources. The results have been compared with other technique showing a better capability to correct the attenuation map of inspected objects unveiling their inner structure otherwise concealed by the poor contrast caused by the beam divergence and attenuation, in particular for those regions far apart from the vertical of the source.

07 ISOTOPE AND RADIATION SOURCES↗

Improvement of density resolution in short-pulse hard x-ray radiographic imaging using detector stacks

We demonstrate that stacking several imaging plates (IPs) constitutes an easy method to increase hard x-ray detection efficiency. Used to record x-ray radiographic images produced by an intense-laser driven hard x-ray backlighter source, the IP stacks resulted in a significant improvement of the radiograph density resolution. We attribute this to the higher quantum efficiency of the combined detectors, leading to a reduced photon noise. Electron-photon transport simulations of the interaction processes in the detector reproduce the observed contrast improvement. Increasing the detection efficiency to enhance radiographic imaging capabilities is equally effective as increasing the x-ray source yield, e.g., by a larger drive laser energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Workshop on Radiographic Imaging and Applications Research and Development Recommendations for Field Radiography

The Workshop on Radiographic Imaging and Applications (WORIA) brought together subject matter experts from industry, academia, US and UK government agencies, and the national laboratories to provide a forum to liaise and share information between technology developers in government and industry, end users, and mission stakeholder to produce an “expert consensus view” regarding future research directions toward a comprehensive radiography/penetrating imaging portfolio in the Defense Nuclear Nonproliferation Research and Development Near Field Detection Portfolio. The inaugural WORIA was held at the Spallation Neutron Source at Oak Ridge National Laboratory on February 7–9, 2023. The inaugural WORIA meeting focused on field radiography applications, or situations in which a portable imaging system must be brought to an item of interest (rather than the item brought to an imaging facility). This report documents consensus views derived from the meeting and provides research and development recommendations for federal program managers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy radiographic imaging performance of LYSO

Here, a comprehensive comparison of the dominant sources of radiation-induced blur for radiographic imaging system performance is made. End-point energies of 6, 10, 15, and 20 MeV bremsstrahlung photon radiation produced at the Los Alamos National Laboratory Microtron facility were used to examine the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO:Ce) scintillators 3, 5 and 10 mm thick. The system resolution was measured and compared between the various end-point energies and scintillator thicknesses. Contrary to expectations, it is found that there was only a minor dependence of system resolution on scintillator thickness or beam end-point energy. This indicates that increased scintillator thickness does not have a dramatic effect on system performance. The data are then compared to Geant4 simulations to assess contributions to the system performance through the examination of modulation transfer functions. It was determined that the low-frequency response of the system is dominated by the radiation-induced signal, while the higher-frequency response of the system is dominated by the optical imaging of the scintillation emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEDICATED FILTER FOR DEFECTS CLUSTERING IN RADIOGRAPHIC IMAGE

Defect clusters such as linear or clustered porosity are in some cases even more important than single flaws. This paper presents two methods of defect clustering and algorithm for calculation of distances between flaws in digital radiographic image. Dedicated lookup table based filter is used for calculation of distances between objects in the specified range. For defect clustering two functions were developed. First one is based on MMD (Minimum Mean Distance) algorithm. Second one uses hierarchical procedures for clustering defects of various types, shapes and size.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗