Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser-driven x-ray and proton micro-source and application to simultaneous single-shot bi-modal radiographic imaging

Radiographic imaging with x-rays and protons is an omnipresent tool in basic research and applications in industry, material science and medical diagnostics. The information contained in both modalities can often be valuable in principle, but difficult to access simultaneously. Laser-driven solid-density plasma-sources deliver both kinds of radiation, but mostly single modalities have been explored for applications. Their potential for bi-modal radiographic imaging has never been fully realized, due to problems in generating appropriate sources and separating image modalities. Here, we report on the generation of proton and x-ray micro-sources in laser-plasma interactions of the focused Texas Petawatt laser with solid-density, micrometer-sized tungsten needles. We apply them for bi-modal radiographic imaging of biological and technological objects in a single laser shot. Thereby, advantages of laser-driven sources could be enriched beyond their small footprint by embracing their additional unique properties, including the spectral bandwidth, small source size and multi-mode emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Film adhesive enhances neutron radiographic images

Resolution of neutron radiographic images of thermally conductive film is increased by replacing approximately 5 percent of aluminum powder, which provides thermal conductivity, with gadolinium oxide. Oxide is also chemically stable.

Reed, M. W.↗

Seed viability detection using computerized false-color radiographic image enhancement

Seed radiographs are divided into density zones which are related to seed germination. The seeds which germinate have densities relating to false-color red. In turn, a seed sorter may be designed which rejects those seeds not having sufficient red to activate a gate along a moving belt containing the seed source. This results in separating only seeds with the preselected densities representing biological viability lending to germination. These selected seeds demand a higher market value. Actual false-coloring isn't required for a computer to distinguish the significant gray-zone range. This range can be predetermined and screened without the necessity of red imaging. Applying false-color enhancement is a means of emphasizing differences in densities of gray within any subject from photographic, radiographic, or video imaging. Within the 0-255 range of gray levels, colors can be assigned to any single level or group of gray levels. Densitometric values then become easily recognized colors which relate to the image density. Choosing a color to identify any given density allows separation by morphology or composition (form or function). Additionally, relative areas of each color are readily available for determining distribution of that density by comparison with other densities within the image.

Vozzo, J. A.↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus ‘super-resolution’). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

47 OTHER INSTRUMENTATION↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus $super$-$resolution$). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Workshop on Radiographic Imaging and Applications Research and Development Recommendations for Field Radiography

The Workshop on Radiographic Imaging and Applications (WORIA) brought together subject matter experts from industry, academia, US and UK government agencies, and the national laboratories to provide a forum to liaise and share information between technology developers in government and industry, end users, and mission stakeholder to produce an “expert consensus view” regarding future research directions toward a comprehensive radiography/penetrating imaging portfolio in the Defense Nuclear Nonproliferation Research and Development Near Field Detection Portfolio. The inaugural WORIA was held at the Spallation Neutron Source at Oak Ridge National Laboratory on February 7–9, 2023. The inaugural WORIA meeting focused on field radiography applications, or situations in which a portable imaging system must be brought to an item of interest (rather than the item brought to an imaging facility). This report documents consensus views derived from the meeting and provides research and development recommendations for federal program managers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved radiographic image amplifier panel

Layered image amplifier for radiographic /X ray and gamma ray/ applications, combines very high radiation sensitivity with fast image buildup and erasure capabilities by adding a layer of material that is both photoconductive and light-emitting to basic image amplifier and cascading this assembly with a modified Thorne panel.

Brown, R. L., Sr.↗

Digital processing of radiographic images

Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

Bond, A. D.↗

Advanced radiographic imaging techniques.

Examination of the nature and operational constraints of conventional X-radiographic and neutron imaging methods, providing a foundation for a discussion of advanced radiographic imaging systems. Two types of solid-state image amplifiers designed to image X rays are described. Operational theory, panel construction, and performance characteristics are discussed. A closed-circuit television system for imaging neutrons is then described and the system design, operational theory, and performance characteristics are outlined. Emphasis is placed on a description of the advantages of these imaging systems over conventional methods.

Beal, J. B.↗

Analog enhancement of radiographic images

The paper shows how analog methods for edge sharpening, contrast enhancement, and expansion of the range of gray levels of particular interest are effective for easy on-line application to video viewing of X-ray roentgenograms or to fluoroscopy. The technique for analog enhancement of radiographic images is a modified version of the system designed by Fuchs et al. (1972), whereby an all directional second derivative signal called detail signal is used to produce both vertical and horizontal enhancement of the image. Particular attention is given to noise filtration and contrast enhancement. Numerous radiographs supplement the text.

Baily, N. A.↗

Computer processing of radiographic images

In the past 20 years, a substantial amount of effort has been expended on the development of computer techniques for enhancement of X-ray images and for automated extraction of quantitative diagnostic information. The historical development of these methods is described. Illustrative examples are presented and factors influencing the relative success or failure of various techniques are discussed. Some examples of current research in radiographic image processing is described.

Selzer, R. H.↗

Solid state radiographic image amplifiers, part C

The contrast sensitivity of the radiographic amplifiers, both the storage type and nonstorage type, their absolute sensitivity, and the reproducibility of fabrication were investigated. The required 2-2T quality level was reached with the radiographic storage screen. The sensitivity threshold was 100 to 200 mR with 45 to 100 kV filtered X-rays. The quality level of the radiographic amplifier screen (without storage) was 4-4T; for a 6 mm (0.25 in.) thick aluminum specimen, a 1 mm (0.040 in.) diameter hole in a 0.25 mm (0.010 in.) thick penetrameter was detected. Its sensitivity threshold was 2 to 6 mR/min. The developed radiographic screens are applicable for uses in nondestructive testing.

Szepesi, Z.↗