Engineering PapersSearch

SEARCH · Engineering Papers

Results for “radiation dose estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiation dose estimates for typical piloted NTR lunar and Mars mission engine operations

The natural and manmade radiation environments to be encountered during lunar and Mars missions are qualitatively summarized. The computational methods available to characterize the radiation environment produced by an operating nuclear propulsion system are discussed. Mission profiles and vehicle configurations are presented for a typical all-propulsive, fully reusable lunar mission and for a typical all-propulsive Mars mission. Estimates of crew location biological doses are developed for all propulsive maneuvers. Post-shutdown dose rates near the nuclear engine are estimated at selected mission times.

Schnitzler, Bruce G.

Effect of Anatomical Modeling on Space Radiation Dose Estimates: A Comparison of Doses for NASA Phantoms and 5th, 50th, and 95th Percentile UF Hybrid Phantoms

The estimate of absorbed dose to individual organs of a space crewmember is affected by the geometry of the anatomical model of the astronaut used in the radiation transport calculation. For astronaut dosimetry, NASA currently uses the computerized anatomical male (CAM) and computerized anatomical female (CAF) stylized phantoms to represent astronauts in its operational radiation dose analyses. These phantoms are available in one size and in two body positions. In contrast, the UF Hybrid Adult Male and Female (UFHADM and UFHADF) phantoms have organ shapes based on actual CT data. The surfaces of these phantoms are defined by non-uniform rational B-spline surfaces, and are thus flexible in terms of body morphometry and extremity positioning. In this study, UFHADM and UFHADF are scaled to dimensions corresponding to 5th, 50th, and 95th percentile (PCTL) male and female astronauts. A ray-tracing program is written in Visual Basic 2008, which is then used to create areal density maps for dose points corresponding to various organs within the phantoms. The areal density maps, along with appropriate space radiation spectra, are input into the NASA program couplet HZETRN/BRYNTRN, and organ doses are calculated. The areal density maps selected tissues and organs of the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared. In addition, the organ doses for the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared to organ doses for CAM and CAF.

Bahadori, A.

Space radiation dose estimates on the surface of Mars

The Langley cosmic ray transport code and the Langley nucleon transport code (BRYNTRN) are used to quantify the transport and attenuation of galactic cosmic rays (GCR) and solar proton flares through the Martian atmosphere. Surface doses are estimated using both a low density and a high density carbon dioxide model of the atmosphere which, in the vertical direction, provides a total of 16 g/sq cm and 22 g/sq cm of protection, respectively. At the Mars surface during the solar minimum cycle, a blood-forming organ (BFO) dose equivalent of 10.5 to 12 rem/yr due to galactic cosmic ray transport and attenuation is calculated. Estimates of the BFO dose equivalents which would have been incurred from the three large solar flare events of August 1972, November 1960, and February 1956 are also calculated at the surface. Results indicate surface BFO dose equivalents of approximately 2 to 5, 5 to 7, and 8 to 10 rem per event, respectively. Doses are also estimated at altitudes up to 12 km above the Martian surface where the atmosphere will provide less total protection.

Simonsen, Lisa C.

Reliability of equivalent sphere model in blood-forming organ dose estimation

The radiation dose equivalents to blood-forming organs (BFO's) of the astronauts at the Martian surface due to major solar flare events are calculated using the detailed body geometry of Langley and Billings. The solar flare spectra of February 1956, November 1960, and August 1972 events are employed instead of the idealized Webber form. The detailed geometry results are compared with those based on the 5-cm sphere model which was used often in the past to approximate BFO dose or dose equivalent. Larger discrepancies are found for the later two events possibly due to the lower numbers of highly penetrating protons. It is concluded that the 5-cm sphere model is not suitable for quantitative use in connection with future NASA deep-space, long-duration mission shield design studies.

Shinn, Judy L.

Visual assessment of the radiation distribution in the ISS Lab module: visualization in the human body

The US Lab module of the International Space Station (ISS) is a primary working area where the crewmembers are expected to spend majority of their time. Because of the directionality of radiation fields caused by the Earth shadow, trapped radiation pitch angle distribution, and inherent variations in the ISS shielding, a model is needed to account for these local variations in the radiation distribution. We present the calculated radiation dose (rem/yr) values for over 3,000 different points in the working area of the Lab module and estimated radiation dose values for over 25,000 different points in the human body for a given ambient radiation environment. These estimated radiation dose values are presented in a three dimensional animated interactive visualization format. Such interactive animated visualization of the radiation distribution can be generated in near real-time to track changes in the radiation environment during the orbit precession of the ISS.

NASA Center JSC

Radiation exposure and dose estimates for a nuclear-powered manned Mars sprint mission

A conceptual manned mission to Mars is analyzed in order to estimate potential ionizing radiation doses that may be incurred by crew members during the course of the mission. The scenario is set for a journey during the solar active period and includes a brief stay on the Martian surface. Propulsion is assumed to be provided by nuclear thermal rocket power, and estimates of the dose contributions from the reactors are included. However, due to effective shielding of the reactors by large propellant tanks, it is found that the incurred doses are principally due to the charged particle natural environment. Recent data (August-December 1989) for large solar proton events are used to simulate the flame environment, while standard models are used for the trapped particle and galactic cosmic ray contributions. Shield effectiveness for several candidate materials are investigated.

Nealy, John E.

Distribution of plutonium and radium in the human heart

Since 1968, the United States Transuranium and Uranium Registries (USTUR) has studied the biokinetics and tissue dosimetry of uranium and transuranium elements in nuclear workers. As part of the USTUR collaboration with the Million Person Study of Low-Dose Health Effects, radiation dose to different parts of the human heart is being estimated for workers with documented intakes of 239 Pu or 226 Ra. The study may be expanded for workers with intakes of 238 U and other radionuclides. The distribution of radionuclides, expressed in terms of concentration (Bq per kg of tissue) serves as an important parameter for estimating radiation dose. Based on available organs from workers who donated their bodies or tissues for research, nine undissected hearts were selected: seven from USTUR registrants with plutonium exposure (males) and two individuals with radium intakes (female and male). For the plutonium workers, estimated 239 Pu systemic deposition ranged from <74 Bq to 1765 Bq. Estimated 226 Ra ‘initial systemic intakes’ were 10.1 MBq and 14.8 kBq for the female patient and male worker, respectively. Organ dissection was based on a heart model published by Borrego et al (2019 J. Radiol. Prot. 39 950–65). This model includes nine cardiac substructures: aorta, left main coronary artery, left atrium, left anterior descending artery, left circumflex artery, left ventricle, right atrium, right coronary artery, and right ventricle. In addition, heart valves, fat attached to epicardium, fluids, and a coronary bypass graft were collected resulting in 111 samples that are currently undergoing radiochemical analyses and mass-spectrometric measurements. The 239 Pu and 226 Ra evaluations are not completed. The results of this study are intended to support radiation worker health studies by improving associated dosimetric and epidemiological models.

USTUR

HEMODOSE: A Set of Multi-parameter Biodosimetry Tools

There continues to be important concerns of the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow (BM) injury. This is due to the fact that hematopoietic system is a vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. In this work we describe the HEMODOSE web tools, which are built upon solid physiological and pathophysiological understanding of mammalian hematopoietic systems, and rigorous coarse-grained biomathematical modeling and validation. Using single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure, these tools can estimate absorbed doses of adult victims very rapidly and accurately to assess the severity of BM radiation injury. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. HEMODOSE web tools establish robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in very late phase (up to 4 weeks) after exposure.

Hu, Shaowen

MTL_TX: A Multi-Task Transformer Model for Improved Radiation Time-Series Estimation

Controlling radiation doses at potential radioactive facilities is critical to ensuring the safety of both personnel and the public. At the Thomas Jefferson National Accelerator Facility (JLab), multiple sensors are deployed around the three experimental halls to monitor key parameters, including single-beam current, energy levels, current leakage, and radiation values during accelerator operations. In this study, we developed a Multi-task Transformer model, MTL_TX, to accurately estimate radiation doses at sensor locations based on historical data, with the aim of enhancing safety in accelerator facilities and surrounding public areas. To improve estimation accuracy, we integrated two innovative components into the proposed model: hierarchical feature embedding (HFE) and multi-level decomposition attention (MDA). Additionally, the multi-task learning (MTL) framework effectively leverages correlations among multiple sensors, enabling individual estimations for each sensor. MTL_TX achieved outstanding results on data collected in 2018, with an MSE of 0.1464, an RMSE of 0.2353, and an R 2 score of 0.8584. Furthermore, when trained on 2018 data, MTL_TX exhibited excellent generalization capability to unseen datasets from 2016 to 2019, achieving an MSE of 0.1407, an RMSE of 0.2263, and an R 2 score of 0.8831. These results demonstrate a significant improvement over existing state-of-the-art models.

Transformer

The Effect of a Mars Mission on Chromosome Damage in the Blood Lymphocytes of Astronauts

The radiation environment encountered during a manned mission to Mars will lead to significant elevation of biological damage in astronauts. Here we present estimates of the increased frequencies of chromosome aberrations in the peripheral blood lymphocytes of astronauts after a hypothetical Mars mission using radiation dose estimations and lymphocyte biology. Results will incorporate previously published data on in vivo induced chromosome damage in the blood lymphocytes of crewmembers after ISS and Mir missions, along with recent findings on the time dependant decay of chromosome aberrations after space flight.

George, Kerry A.

HEMODOSE: A Set of Multi-parameter Biodosimetry Tools

After the events of September 11, 2001 and recent events at the Fukushima reactors in Japan, there is an increasing concern of the occurrence of nuclear and radiological terrorism or accidents that may result in large casualty in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine the radiation induced changes at different biological levels. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced injury. This is due to the fact that hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as the most practical and best laboratory test to estimate radiation dose. The HEMODOSE web tools are built upon solid physiological and pathophysiological understanding of mammalian hematopoietic systems, and rigorous coarse-grained biomathematical modeling and validation. Using single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure, these tools can estimate absorbed doses of adult victims very rapidly and accurately. Some patient data in historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large scale radiological disaster scenario. Unlike previous dose prediction algorithms, the HEMODOSE web tools establish robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in very late phase (up to 4 weeks) after exposure

Hu, Shaowen

A Multiple Parameters Biodosimetry Tool with Various Blood Cell Counts - the Hemodose Approach

There continue to be important concerns about the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow injury. This is due to the fact that the hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. Based upon years of physiological and pathophysiological investigation of mammalian hematopoietic systems, and rigorous coarse-grained bio-mathematical modeling and validation on species from mouse, to dog, monkey, and human, we have developed a set of software tools Hemodose, which can use single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure to estimate absorbed doses of adult victims very rapidly and accurately. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. Most significant to the improvement of national and local preparedness of a potential nuclear/radiological disaster, this HemoDose approach establishes robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in the very late phase (up to 4 weeks) after exposure.

Hu, Shaowen

A Launch Requirements Trade Study for Active Space Radiation Shielding for Long Duration Human Missions

A trade study for an active shielding concept based on magnetic fields in a solenoid configuration versus mass based shielding was developed. Monte Carlo simulations were used to estimate the radiation exposure for two values of the magnetic field strength and the mass of the magnetic shield configuration. For each field strength, results were reported for the magnetic region shielding (end caps ignored) and total region shielding (end caps included but no magnetic field protection) configurations. A value of 15 cSv was chosen to be the maximum exposure for an astronaut. The radiation dose estimate over the total shield region configuration cannot be used at this time without a better understanding of the material and mass present in the end cap regions through a detailed vehicle design. The magnetic shield region configuration, assuming the end cap regions contribute zero exposure, can be launched on a single Space Launch System rocket and up to a two year mission can be supported. The magnetic shield region configuration results in two versus nine launches for a comparable mass based shielding configuration. The active shielding approach is clearly more mass efficient because of the reduced number of launches than the mass based shielding for long duration missions.

Singleterry, Robert C., Jr.

Application of FISH based G2-PCC assay for the cytogenetic assessment of high radiation dose exposures: Potential implications for rapid triage biodosimetry

The main goal of this study is to test the utility of calyculin A induced G2-PCC assay as a biodosimetry triage tool for assessing a wide range of low and acute high radiation dose exposures of photons. Towards this initiative, chromosome aberrations induced by low and high doses of x-rays were evaluated and characterized in G2-prematurely condensed chromosomes (G2-PCCs) by fluorescence in situ hybridization (FISH) using human centromere and telomere specific PNA (peptide nucleic acid) probes. A dose dependent increase in the frequency of dicentric chromosomes was observed in the G2-PCCs up to 20 Gy of x-rays. The combined yields of dicentrics and rings in the G2-PCCs showed a clear dose dependency up to 20 Gy from 0.02/cell for 0.1 Gy to 14.98/cell for 20 Gy. Centric rings were observed more frequently than acentric ring chromosomes in the G2-PCCs at all the radiation doses from 1 Gy to 20 Gy. A head-to-head comparison was also performed by FISH on the yields of chromosome aberrations induced by different doses of x-rays (0 Gy -7.5 Gy) in colcemid arrested metaphase chromosomes and calyculin A induced G2-PCCs. In general, the frequencies of dicentrics, rings and acentric fragments were slightly higher in G2-PCCs than in colcemid arrested metaphase chromosomes at all the radiation doses, but the differences were not statistically significant. To reduce the turnaround time for absorbed radiation dose estimation, attempt was made to obtain G2-PCCs by reducing the culture time to 36 hrs. The absorbed doses estimated in x-rays irradiated (0,1,2 and 4 Gy) G2-PCCs after 36 hrs of culture were grossly like that of G2-PCCs and colcemid arrested metaphase chromosomes prepared after 48 hrs of culture. Our study indicates that the shortened version of calyculin A induced G2-PCC assay coupled with the FISH staining technique can serve as an effective triage biodosimetry tool for large-scale radiological/nuclear incidents.

Science & Technology - Other Topics