The Quench Protection of Direct Wind Magnets
The direct wind magnets have several unique features. The conductor layout is characterized by thin single conductors wound over long lengths and separated from the other turns with thick layer of insulation. Moreover, there are several layers of winding. The strong non-uniformity in the magnetic field distribution results in different current and thermal margins for quenching in different regions. The quench protection modeling involves multi-physics coupling between electrical, thermal and magnetic transient. The material properties vary over time and location. This coupled with the complexity in the geometry adds to long computation times. The objective of this study is to understand the quench propagation in an EIC high inductance direct wind magnet which enables one to design appropriate quench protection strategies to protect the magnet. An advanced modeling program has been developed to simulate direct wind magnet quench. In conclusion, we validate theoretical simulations with experimental data.