Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum state tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Behavior of the maximum likelihood in quantum state tomography

Quantum state tomography on a d-dimensional system demands resources that grow rapidly with d. They may be reduced by using model selection to tailor the number of parameters in the model (i.e., the size of the density matrix). Most model selection methods typically rely on a test statistic and a null theory that describes its behavior when two models are equally good. Here, we consider the loglikelihood ratio. Because of the positivity constraint ρ ≥ 0, quantum state space does not generally satisfy local asymptotic normality (LAN), meaning the classical null theory for the loglikelihood ratio (the Wilks theorem) should not be used. Thus, understanding and quantifying how positivity affects the null behavior of this test statistic is necessary for its use in model selection for state tomography. We define a new generalization of LAN, metric-projected LAN, show that quantum state space satisfies it, and derive a replacement for the Wilks theorem. In addition to enabling reliable model selection, our results shed more light on the qualitative effects of the positivity constraint on state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variational approach to quantum state tomography based on maximal entropy formalism

Quantum state tomography is an integral part of quantum computation and offers the starting point for the validation of various quantum devices. One of the central tasks in the field of state tomography is to reconstruct, with high fidelity, the quantum states of a quantum system. From an experiment on a real quantum device, one can obtain the mean measurement values of different operators. With such data as input, in this report we employ the maximal entropy formalism to construct the least biased mixed quantum state that is consistent with the given set of expectation values. Even though, in principle, the reported formalism is quite general and should work for an arbitrary set of observables, in practice we shall demonstrate the efficacy of the algorithm on an informationally complete (IC) set of Hermitian operators. Such a set possesses the advantage of uniquely specifying a single quantum state from which the experimental measurements have been sampled and hence renders the rare opportunity not only to construct a least-biased quantum state but even replicate the exact state prepared experimentally within a preset tolerance. Here, the primary workhorse of the algorithm is reconstructing an energy function which we designate as the effective Hamiltonian of the system, and parameterizing it with Lagrange multipliers, according to the formalism of maximal entropy. These parameters are thereafter optimized variationally so that the reconstructed quantum state of the system converges to the true quantum state within an error threshold. To this end, we employ a parameterized quantum circuit and a hybrid quantum-classical variational algorithm to obtain such a target state, making our recipe easily implementable on a near-term quantum device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing multi-step quantum state tomography by PhaseLift

Multi-photon system has been studied by many groups, however the biggest challenge faced is the number of copies of an unknown state are limited and far from detecting quantum entanglement. The difficulty to prepare copies of the state is even more serious for the quantum state tomography. One possible way to solve this problem is to use adaptive quantum state tomography, which means to get a preliminary density matrix in the first step and revise it in the second step. In order to improve the performance of adaptive quantum state tomography, we develop a new distribution scheme of samples and extend it to three steps, that is to correct it once again based on the density matrix obtained in the traditional adaptive quantum state tomography. Our numerical results show that the mean square error of the reconstructed density matrix by our new method is improved to the level from 10{sup −4} to 10{sup −9} for several tested states. In addition, PhaseLift is also applied to reduce the required storage space of measurement operator. - Highlights: • PhaseLift is firstly applied in the adaptive quantum state tomography and the required store space of measurement operator is reduced. • Traditional adaptive quantum state tomography is extended to three-step adaptive quantum state tomography. • A new scheme of copy distribution of state is proposed to effectively use the limited copies of state. • For several tested states, the mean square error of the reconstructed state is reduced to 10{sup −9} from 10{sup −4}. • Fidelity is more accurately estimated with limited copies of state compared with traditional adaptive quantum state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computationally efficient Bayesian quantum state tomography

We describe a method for Bayesian quantum state estimation combining efficient parameterization, a pseudo-likelihood, and advanced numerical sampling techniques. Examples reveal significant computational speedup, indicating the approach’s promise in practical quantum state tomography.

Lukens, Joseph↗

Efficient quantum state tomography with mode-assisted training

Neural networks (NNs) representing quantum states are typically trained using Markov chain Monte Carlo based methods. However, unless specifically designed, such samplers only consist of local moves, making the slow-mixing problem prominent even for extremely simple quantum states. Here, we propose to use mode-assisted training that provides global information via the modes of the NN distribution. Further, applied to quantum state tomography using restricted Boltzmann machines, this method improves the quality of reconstructed quantum states by orders of magnitude. The method is applicable to other types of NNs and may efficiently tackle problems previously unmanageable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding boundary effects in quantum state tomography – One qubit case

For classical and quantum estimation with finite data sets, the estimation error can deviate significantly from its asymptotic (large data set) behavior. In quantum state tomography, a major reason for this is the existence of a boundary in the parameter space imposed by constraints, such as the positive semidefiniteness of density matrices. Intuitively, we should be able to reduce the estimation error by using our knowledge of these constraints. This intuition is correct for maximumlikelihood estimators, but the size of the reduction has not been evaluated quantitatively. In this proceeding, we evaluate the improvement in one qubit state tomography by using mathematical tools in classical statistical estimation theory. In particular, we show that the effect of the reduction decreases exponentially with respect to the number of data sets when the true state is mixed, and it remains at arbitrarily large data set when the true state is pure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum state tomography and fidelity estimation via Phaselift

Experiments of multi-photon entanglement have been performed by several groups. Obviously, an increase on the photon number for fidelity estimation and quantum state tomography causes a dramatic increase in the elements of the positive operator valued measures (POVMs), which results in a great consumption of time in measurements. In practice, we wish to obtain a good estimation of fidelity and quantum states through as few measurements as possible for multi-photon entanglement. Phaselift provides such a chance to estimate fidelity for entangling states based on less data. In this paper, we would like to show how the Phaselift works for six qubits in comparison to the data given by Pan’s group, i.e., we use a fraction of the data as input to estimate the rest of the data through the obtained density matrix, and thus goes beyond the simple fidelity analysis. The fidelity bound is also provided for general Schrödinger Cat state. Based on the fidelity bound, we propose an optimal measurement approach which could both reduce the copies and keep the fidelity bound gap small. The results demonstrate that the Phaselift can help decrease the measured elements of POVMs for six qubits. Our conclusion is based on the prior knowledge that a pure state is the target state prepared by experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence procedure for efficient quantum-state tomography

I show that in tomographic experiments, the measurement of a small set of observables suffices to confirm or incrementally amend prior expectations with a high degree of confidence. To this end, I adapt the evidence procedure, an estimation technique used in classical image reconstruction, for use in quantum-state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum-state tomography of a single nuclear spin qubit of an optically manipulated ytterbium atom

A single Yb atom is loaded into a high-finesse optical cavity with a moving lattice, and its nuclear spin state is manipulated using a nuclear magnetic resonance technique. A highly reliable quantum state control with fidelity and purity greater than 0.98 and 0.96, respectively, is confirmed by the full quantum state tomography; a projective measurement with high speed (500 {mu}s) and high efficiency (0.98) is accomplished using the cavity QED technique. Because a hyperfine coupling is induced only when the projective measurement is operational, the long coherence times (T{sub 1}=0.49 s and T{sub 2}=0.10 s) are maintained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al.[R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of 'minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multidimensional approach to quantum state tomography of photoelectron wavepackets

There is a growing interest in reconstructing the density matrix of photoelectron wavepackets, in particular in complex systems where decoherence can be introduced either by a partial measurement of the system or through coupling with a stochastic environment. To this end, several methods to reconstruct the density matrix, quantum state tomography protocols, have been developed and tested on photoelectrons ejected from noble gases following absorption of extreme ultraviolet (XUV) photons from attosecond pulses. It remains a challenge to obtain model-free, single scan protocols that can reconstruct the density matrix with high fidelities. Current methods require extensive measurements or involve complex fitting of the signal. Efficient single-scan reconstructions would be of great help to increase the number of systems that can be studied. We propose a new and more efficient protocol that is able to reconstruct the continuous variable density matrix of a photoelectron in a single time delay scan. It is based on measuring the coherences of a photoelectron created by absorption of an XUV pulse using a broadband infrared (IR) probe that is scanned in time and a narrowband IR reference that is temporally fixed to the XUV pulse. We illustrate its performance for a Fano resonance in He as well as mixed states in Ar arising from spin-orbit splitting. We show that the protocol results in excellent fidelities and near-perfect estimation of the purity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular axis distribution moments in ultrafast transient absorption spectroscopy: A path toward ultrafast quantum state tomography

In ultrafast time-resolved experiments with gas phase molecules, the alignment of the molecular axis relative to the polarization of the interacting laser pulses plays a crucial role in determining the dynamics following this light–matter interaction. The molecular axis distribution is influenced by the interacting pulses and is intrinsically linked to the electronic coherences of the excited molecules. However, in typical theoretical calculations of such interactions, the signal is either calculated for a single molecule in the molecular frame or averaged over all possible molecular orientations to compare with the experiment. Such averaging removes information about anisotropy in the molecular-axis distribution, even though anisotropic contributions can play a significant role in the measured experimental signal. Here, we calculate the laboratory frame transient electronic first-order polarization [P (1) ] spectra in terms of separated molecular frame and laboratory frame quantities. The laboratory frame polarizations are compared with orientation-averaged quantum master equation calculations, demonstrating that orientation-averaging captures only the isotropic contributions. We show that our formalism also allows us to evaluate the anisotropic contributions to the spectrum. Lastly, we discuss the application of this approach to achieve ultrafast quantum state tomography using transient absorption spectroscopy and field observables in nonlinear spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Regularizing least squares quantum state tomography with classical shadows

Classical shadows herald remarkable opportunities for resource-efficient quantum estimation. Although superficially disconnected from traditional inference methods, we show how classical shadows fit under a larger umbrella of least squares regularization, revealing tradeoffs with related methods.

Zhu, Zhihui [Ohio State University]↗

Quantum state tomography with fully symmetric measurements and product measurements

We introduce random-matrix theory to study the tomographic efficiency of a wide class of measurements constructed out of weighted 2-designs, including symmetric informationally complete (SIC) probability operator measurements (POMs). In particular, we derive analytic formulas for the mean Hilbert-Schmidt distance and the mean trace distance between the estimator and the true state, which clearly show the difference between the scaling behaviors of the two error measures with the dimension of the Hilbert space. We then prove that the product SIC POMs, the multipartite analog of the SIC POMs, are optimal among all product measurements in the same sense as the SIC POMs are optimal among all joint measurements. We further show that, for bipartite systems, there is only a marginal efficiency advantage of the joint SIC POMs over the product SIC POMs. In marked contrast, for multipartite systems, the efficiency advantage of the joint SIC POMs increases exponentially with the number of parties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗