Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Installation Quality Framework: Investment Return Approach for Energy Savings on Building Product Installation

A case study was conducted on 44 residential homes using both traditional house wrap and ZIP System systems to measure the overall airtightness and compare estimated energy usages. The labor, material, and overhead and profit (O&P) costs were analyzed and used to determine the optimal choice for long-term benefits in terms of cost and performance. The impact of insulation installation is considered a key factor in improving the strategy of reducing energy consumption. Improved installation practices can affect the airtightness of common wall assemblies to reduce the building energy performance gaps and provide insight on how to allocate resources better. A framework was developed to analyze operational costs and building energy performance to address how installation quality is a factor in the return of investment in building construction for heating and cooling systems within the thermal envelope. With this methodology, aggressive energy performance goals will be met while balancing the tradeoff between installation techniques and building systems efficiency based on the introduced probabilistic investment return (PIR) metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Residential HVAC Systems: Evaluating How the Usage of Smart Diagnostic Tools for Quality Installation and Commissioning Impacts System Performance and HVAC Contractor Businesses

The adoption of digital quality installation and fault detection tools has the potential to transform the $14 billon residential heating, ventilating, and air conditioning (HVAC) service and installation industry. Increased market penetration can be accelerated by providing an increased understanding of the energy and economic value proposition of the usage of these tools. In tandem with energy and HVAC system performance impact research and analysis, the Southface Team investigated the economic business implications for HVAC service and installation contractors adopting the use of measureQuick (mQ), a smart diagnostic app that aids in quality installation and fault detection and works agnostically with Bluetooth-enabled HVAC technician tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Fault Detection & Diagnostics: Residential Market Analysis

This report provides an overview of the market potential for automated fault detection and diagnostics (AFDD) in the residential sector, focusing on embedded AFDD in central air conditioners (CAC) and air-source heat pumps (ASHP) as well as the use of smart diagnostic tools to ensure quality installation of CAC/ASHP equipment. The contents include background on AFDD, stakeholder engagement efforts, a technology assessment of AFDD and smart diagnostic tools, residential CAC and ASHP market trends, a characterization of the CAC and ASHP installed base, a synopsis of utility provider programs, and market barriers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) Quality Assurance Program - 20237

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous HEPA filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The SSCVS project has proceeded with the awarding of CD-3A for Long Lead Procurements followed by CD-2/3 approval for the construction of the facilities. The SSCVS project team made the decision to increase the quality oversight throughout the complete project per the Project Quality Assurance Plan (PQAP) such that it can ensure the final products meet applicable NQA-1 requirements and general quality requirements, and that the project will proceed to operations without significant delays due to post installation quality concerns. The PQAP was established prior to approval of the project at the CD-2/3 milestone. The SSCVS project has 2 major long lead procurements which commenced with the awarding of CD-3A. These procurements include the HEPA filter housing assemblies and the Exhaust Fans. There are 22 HEPA filter assemblies for the SSCVS, which are designated Safety Significant for pressure boundary confinement, per the approved PDSA. The exhaust fans also have Safety Significant components to maintain the pressure confinement boundary. NWP made the decision to install resident Quality Inspectors at the fabrication facilities to ensure the documentation for each fabricated unit meets all the QA requirements as defined in the respective contract documents. For the construction of the SSCVS Salt Reduction Building (SRB) and New Filter Building (NFB), dedicated, on-site quality inspectors have been utilized to ensure that all work being performed will comply with quality requirements and the Special Inspections as defined in IBC-2015. At each stage of inspection, hold points are placed into the work packages to ensure NWP QA personnel are present to inspect and verify the installations are in accordance with the design specifications, codes and standards. With this level of oversight, NWP anticipates that the level of quality related issues, as seen on multiple other DOE complex site projects, will be avoided and that the commissioning, start-up and hot operations will progress in a timely fashion, as all documentation will be in place and approved prior to initiation of these activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Installation and imaging of thousands of minirhizotrons to phenotype root systems of field-grown plants

Roots are vital to plant performance because they acquire resources from the soil and provide anchorage. However, it remains difficult to assess root system size and distribution because roots are inaccessible in the soil. Existing methods to phenotype entire root systems range from slow, often destructive, methods applied to relatively small numbers of plants in the field to rapid methods that can be applied to large numbers of plants in controlled environment conditions. Much has been learned recently by extensive sampling of the root crown portion of field-grown plants. But, information on large-scale genetic and environmental variation in the size and distribution of root systems in the field remains a key knowledge gap. Minirhizotrons are the only established, non-destructive technology that can address this need in a standard field trial. Prior experiments have used only modest numbers of minirhizotrons, which has limited testing to small numbers of genotypes or environmental conditions. This study addressed the need for methods to install and collect images from thousands of minirhizotrons and thereby help break the phenotyping bottleneck in the field. Over three growing seasons, methods were developed and refined to install and collect images from up to 3038 minirhizotrons per experiment. Modifications were made to four tractors and hydraulic soil corers mounted to them. High quality installation was achieved at an average rate of up to 84.4 minirhizotron tubes per tractor per day. A set of four commercially available minirhizotron camera systems were each transported by wheelbarrow to allow collection of images of mature maize root systems at an average rate of up to 65.3 tubes per day per camera. This resulted in over 300,000 images being collected in as little as 11 days for a single experiment. The scale of minirhizotron installation was increased by two orders of magnitude by simultaneously using four tractor-mounted, hydraulic soil corers with modifications to ensure high quality, rapid operation. Image collection can be achieved at the corresponding scale using commercially available minirhizotron camera systems. Along with recent advances in image analysis, these advances will allow use of minirhizotrons at unprecedented scale to address key knowledge gaps regarding genetic and environmental effects on root system size and distribution in the field.

54 ENVIRONMENTAL SCIENCES↗

Accelerating Optimal Integration of Energy Efficiency Strategies with Industrialized Modular Construction: Preprint

The National Renewable Energy Laboratory's (NREL's) Industrialized Construction Innovation team first introduced the Industrialized Construction Assessment Framework to achieve affordable, net-zero energy (NZE) modular multifamily buildings in the 2020 ACEEE paper "Integrating Energy Efficiency Strategies with Industrialized Construction for our Clean Energy Future." Since then, NREL has continued to drive the ambitious plan to accelerate optimal integration of energy efficiency strategies during industrialized construction with little or no additional cost, labor, and production time. This follow-on paper introduces the Energy in Modular (EMOD) buildings method and presents NREL's research efforts over the last two years in collaboration with industry, including affordable housing partners. NREL has developed an idealized NZE modular multifamily building design that incorporates five energy efficiency strategies well suited for industrialized construction in factories: (1) envelope thermal control, (2) envelope infiltration control, (3) mechanical, electrical, and plumbing systems, (4) smart controls, and (5) solar plus storage. This paper highlights results from leveraging design for manufacturing and assembly principles, testing, and validation pilots with factory partners; demonstrating pod prototypes in test stand at NREL; and performing simulations. Overall, these research efforts address barriers to whole-building system integration, such as poor installation quality of thermal and air barriers; lack of unitized systems for space conditioning, energy recovery and ventilation, and water heating; problematic on-site installation, commissioning, and configuration of controls; and lack of cost-effective integration for grid-friendly design and emerging technologies. Conclusively, the paper delineates next steps for future work with NREL's partners toward developing a transformational pathway for our clean energy future.

affordable housing↗

Automated tracking of prefabricated components for areal-time evaluator to optimize and automateinstallation

Trade associations for prefabricated construction estimate that about 50% of prefabricated wall projects have alignment problems that lead to defects and rework. Additionally, component installation times average between 30 and 60 minutes per component. To address these issues, a real-time evaluator (RTE) system was introduced to decrease cost and automate prefabricated component installation by reducing the installation time, decreasing rework, and enhancing energy performance through higher installation quality. The RTE uses commonly available hardware and software to perform autonomous tracking to measure the real-time location and orientation of components as they are crane-lifted and installed. The hardware, software, and algorithms that allow the autonomous tracking of components are detailed. An algorithm to automate the initial search for a component with three attached retroreflectors is proposed. Algorithms to automate the measurement of component position and orientation are also proposed. Simple lab-scale proof-of-concept experiments were conducted to assess the algorithms for automation of component searching, measurement of real-time movement, and measurement of component orientation. With additional development, the system can be used as a tool to generate the commands for autonomous crane operation or single-task construction robots.

Hayes, Nolan↗

Estimating the Value of Worker Training: A System Reliability & LCOE Perspective

This workshop presentation briefly describes the labor standards required for large photovoltaic (PV) systems (>1MWac) to receive the full investment tax credit from the Inflation Reduction Act. The potential for labor standards to affect aspects other than upfront installation costs (such as energy generation or maintenance expenses) is analyzed using levelized cost of energy (LCOE) calculations. This considers benefits which may come from better training for workers, more productive workers, or improved installation quality, using NREL's simplified PV-specific LCOE calculator at pvlcoe.nrel.gov.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

PV Field Reliability Status--Analysis of 100,000 Solar Systems

In this paper, we analyzed annual production data from 100 000 photovoltaic systems as well as comments relating to their performance and maintenance. Our analysis revealed that 80% to 90% of all systems performed within 10% of the predicted production or better. Also, 56% of the systems were still performing above P50 or the median at 5 years. However, a small but significant tail of about 7000 systems perform below P90 expectations. In general, residential systems have a lower rate of failure than utility or commercial systems. Despite higher rates of component failures, utility systems lose less power than residential or commercial systems. This outcome is likely due to closer monitoring and better operations and maintenance practices. Inverters are still the components that reportedly fail most often (4%-6%), but other failures such as unspecified repair and meters cause more production loss. Reported module failures are relatively rare (0.2%) and are within the range of historical values. Installation quality affects performance and safety as indicated by data showing connector, wiring, breaker, and fuse failures due to undersizing, electrical design, and improper connection. Lastly, early detection of degradation and proactive response resulted in less impact on production than reactive, unplanned repairs.

14 SOLAR ENERGY↗

Progress Report of Alloy 709 Performance in Liquid Sodium

With improved high-temperature properties, Alloy 709 shows great potential for advanced reactor applications. To understand the effects of sodium on A709, small tensile specimens were machined from two commercial heats and subject to sodium exposure in two forced convection loops operated by Argonne. Thermal aging experiments were also conducted in parallel to isolate any sodium-specific effects. An increasing trend in yield strength and a decrease trend in ultimate tensile strength can be seen with the increasing exposure time, suggesting microstructural changes at these temperatures. Nonetheless, the thermally aged and sodium exposed samples behaved similarly, implying no sodium-specific effect at these temperatures. In contrast, 316H SS exposed to sodium at 650°C showed a strong sodium effect. The different responses of A709 and 316H SS to sodium exposure is of interest and requires additional effort to understand. The cold traps of the sodium loop were replaced early in FY23. During a maintenance operation, an unexpected sodium leak incident occurred at one of the sodium loops, triggering an emergency response. An investigation into the incident revealed that the leak happened at a VCR fitting on the recently replaced cold trap. The metal gasket of the leaked VCR fitting was not compressed sufficiently. A dimensional mismatch between the new component and old piping configuration was responsible for a significant misalignment. A new cold trap with improved design is in production. The new design provides additional flexibility and an access point for post-installation helium leak check and for venting of trapped gas. These design features will make the system more error-tolerant and the installation quality verifiable. A thermodynamic analysis was performed to understand the carburization-decarburization behavior of A709 in sodium environment. The equilibrium carbon activity in the alloy was evaluated with M 23 C 6 , TiC, and NbC. The carburization-decarburization boundary was calculated with different methods developed previously. The results suggests that A709 will be carburized in SMT-1 and SMT-2, and can be decarburized in low-carbon-activity environments such as EBR-II at temperatures above 620-650°C. Nonetheless, A709 should be less likely to be decarburized than 316H SS when exposed to the same low-carbon-activity environment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗

Application of Manufacturing Quality Management Principles to PV System Installations

To help SETO/DOE achieve its goals, the IBTS team proposed a project addressing system reliability by improving installation standards and quality management. The proposed approach was designed to help achieve measurable reductions in installation defect density and improvements in the performance of PV systems by optimizing design and installation of residential and commercial PV systems. This approach addressed the soft costs associated with installations and quality management. The project demonstrated improved system reliability and reduced PV system installation costs. The software developed improved operations, decreased risk, and increased the overall value of PV systems across their lifecycle. The project used several data collection methods, including extensive industry surveys, face-to-face high-level interviews at industry conferences, stakeholder teleconferences, and in-depth interviews conducted by IBTS staff. Results from the research found the industry needs a uniform assessment method for national providers to be more efficient; the software should support both code officials and installers; most industry stakeholders would find value in a centralized software system that allows them to collect, report, and review information on in-process and completed solar installations; and mobile solutions that bridge existing knowledge gaps with inspectors and integrate with existing methodologies (such as permitting software) are of great value. The software solution developed is web-based, allowing for national access, and is built on a Google Firebase platform that can handle significant users and data. It can be used onsite or remotely, allowing for code compliance to continue despite ongoing pandemic related delays or shutdowns for local economies. The information provided by the software tool allows users to uniformly assess a system for compliance and use that aggregated data to identify training topics or create internal process designed to improving issues and reducing occurrence. This solution has multiple benefits in managing quality at time of use and promoting an increase in future safety and quality through education. Perhaps most importantly, this software increases public safety by ensuring compliance of installed systems and allows for local AHJs to remotely engage specialized and qualified solar specific expertise for oversite of the installation in their jurisdictions. Data analysis provides the quality feedback loop identifying the root cause of failure and drives installation practices to improve through training and education, resulting in systems with higher performance, greater reliability, and reduced operations and maintenance costs. With the successful completion of this project, the industry can expect reduced soft costs and increased performance and safety and will ultimately benefit from longer performing systems that cost less to operate.

14 SOLAR ENERGY↗

Morgan State University Air Quality Monitor Field Campaign Report

This activity was to enable us to install air quality and meteorological instrumentation such as an automated Air Quality Drone, PurpleAir Sensor, and Sensit Ramp Air Quality Sensor. This installation formed part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Coast-Urban-Rural Atmospheric Gradient Experiment (CoURAGE) at the Baltimore site. Figure 1 shows the aerial image of the CoURAGE Baltimore site with all the installed instruments.

47 OTHER INSTRUMENTATION↗

Solar Photovaltaics Durability and Resilience - A Win-Win

Solar photovoltaics (PV) will play a crucial role in decarbonizing the electrical grid and limit the effects of detrimental climate change. Long lifetimes of PV installations are a win-win situation, as it not only reduces carbon emissions directly through avoidance of fossil fuel emissions but also indirectly, as it reduces the demand of needed materials and potentially recycling. However, during their decades-long lifetime expectations installations are also more commonly exposed to extreme weather events. Building durable solar system to withstand extreme weather events is essential in the electrification of the economy and will save lives, particularly when they power critical infrastructure such as hospitals. As more PV is installed in regions prone to extreme weather events, high-quality materials, installation and monitoring practices can mitigate risk. Evaluating resilience requires combined computational, analytical, and experimental capabilities that are best leveraged by teams working across multiple disciplines.

durability↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reimagining Heating, Ventilation, and Air Conditioning for New Manufactured Homes

Manufactured homes represent one of the most affordable paths to home ownership for American households, but minimum-efficiency equipment and poor-quality home installation can lead to excess energy use and high operating costs. Slipstream, with partners from the Florida Solar Energy Center (FSEC), Northwest Energy Works, and Washington State University, identified and tested manufactured home HVAC innovations targeted for new construction offering the most promising mix of improved energy performance and likelihood of industry uptake.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗