The Average Quality Factors by TEPC for Charged Particles

The quality factor used in radiation protection is defined as a function of LET, Q(sub ave)(LET). However, tissue equivalent proportional counters (TEPC) measure the average quality factors as a function of lineal energy (y), Q(sub ave)(Y). A model of the TEPC response for charged particles considers energy deposition as a function of impact parameter from the ion s path to the volume, and describes the escape of energy out of sensitive volume by delta-rays and the entry of delta rays from the high-density wall into the low-density gas-volume. A common goal for operational detectors is to measure the average radiation quality to within accuracy of 25%. Using our TEPC response model and the NASA space radiation transport model we show that this accuracy is obtained by a properly calibrated TEPC. However, when the individual contributions from trapped protons and galactic cosmic rays (GCR) are considered; the average quality factor obtained by TEPC is overestimated for trapped protons and underestimated for GCR by about 30%, i.e., a compensating error. Using TEPC's values for trapped protons for Q(sub ave)(y), we obtained average quality factors in the 2.07-2.32 range. However, Q(sub ave)(LET) ranges from 1.5-1.65 as spacecraft shielding depth increases. The average quality factors for trapped protons on STS-89 demonstrate that the model of the TEPC response is in good agreement with flight TEPC data for Q(sub ave)(y), and thus Q(sub ave)(LET) for trapped protons is overestimated by TEPC. Preliminary comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.2-4.1, while TEPC measures 2.9-3.4 for QQ(sub ave)(y), indicating that QQ(sub ave)(LET) for GCR is underestimated by TEPC.

Kim, Myung-Hee Y.

Quality factors for alpha particles emitted in tissue

A concept of a mean or dose averaged quality factor was defined in ICRP Publication 26 using relationships for quality factor as a function of LET. The concept of radiation weighting factors, wR, was introduced in ICRP Publication 60 in 1990. These are meant to be generalized factors that modify absorbed dose to reflect the risk of stochastic effects as a function of the quality of the radiation incident on the body or emitted by radioactivity within the body. The values of wr are equal to 20 for all alpha particles externally or internally emitted. This note compares the dose averaged quality factor for alpha particles originating in tissue using the old and revised recommendations for quality factor as a function of LET. The dose averaged quality factor never exceeds 20 using the old recommendations and is never less than 20 with the revised recommendations.

Non-NASA Center

Improving the Optical Quality Factor of the WGM Resonator

Resonators usually are characterized with two partially dependent values: finesse (F) and quality factor (Q). The finesse of an empty Fabry-Perot (FP) resonator is defined solely by the quality of its mirrors and is calculated as F=piR(exp 1/2)/(1-R). The maximum up-to-date value of reflectivity R approximately equal to 1 - 1.6 x 10(exp -6) is achieved with dielectric mirrors. An FP resonator made with the mirrors has finesse F=1.9 x 10(exp 6). Further practical increase of the finesse of FP resonators is problematic because of the absorption and the scattering of light in the mirror material through fundamental limit on the reflection losses given by the internal material losses and by thermodynamic density fluctuations on the order of parts in 109. The quality factor of a resonator depends on both its finesse and its geometrical size. A one-dimensional FP resonator has Q=2 F L/lambda, where L is the distance between the mirrors and lambda is the wavelength. It is easy to see that the quality factor of the resonator is unlimited because L is unlimited. F and Q are equally important. In some cases, finesse is technically more valuable than the quality factor. For instance, buildup of the optical power inside the resonator, as well as the Purcell factor, is proportional to finesse. Sometimes, however, the quality factor is more valuable. For example, inverse threshold power of intracavity hyperparametric oscillation is proportional to Q(exp 2) and efficiency of parametric frequency mixing is proportional to Q(exp 3). Therefore, it is important to know both the maximally achievable finesse and quality factor values of a resonator. Whispering gallery mode (WGM) resonators are capable of achieving larger finesse compared to FP resonators. For instance, fused silica resonators with finesse 2.3 x 10(exp 6) and 2.8 x 10(exp 6) have been demonstrated. Crystalline WGM resonators reveal even larger finesse values, F=6.3 x 10(exp 6), because of low attenuation of light in the transparent optical crystals. The larger values of F and Q result in the enhancement of various nonlinear processes. Low-threshold Raman lasing, optomechanical oscillations, frequency doubling, and hyperparametric oscillations based on these resonators have been recently demonstrated. Theory predicts a possibility of nearly 10(exp 14) room-temperature optical Q-factors of optical crystalline WGM resonators, which correspond to finesse levels higher than 10(exp 9). Experiments have shown numbers a thousand times lower than that. The difference occurs due to media imperfections. To substantially reduce the optical losses caused by the imperfections, a specific, multi-step, asymptotic processing of the resonator is implemented. The technique has been initially developed to reduce microwave absorption in dielectric resonators. One step of the process consists of mechanical polishing performed after high temperature annealing. Several steps repeat one after another to lead to significant reduction in optical attenuation and, as a result, to the increase of Q-factor as well as finesse of the resonator which demonstrates a CaF2 WGM resonator with F greater than 10(exp 7) and Q greater than 10(exp 11).

Savchenkov, Anatoliy

On the determination of series resistance and diode quality factor of solar cells

The series resistance and diode quality factor are used for evaluation of solar cell performance. These parameters are normally deduced from the terminal I-V characteristics under forward bias. The method produces a smaller series resistance and a larger value for diode quality factor than appropriate for the device when operating as a solar cell. It is suggested that the diode quality factor be determined from measured saturated photocurrent, open circuit voltage characteristics and the series resistance be measured with an r-f bridge or calculated from a measurement of the surface sheet resistance.

Anderson, R. L.

Track Structure and the Quality Factor for Space Radiation Cancer Risk

A major risk from exposure to space radiation is the induction of cancer and it is from estimates of this risk that the maximum career flight times of NASA space crew members are restricted by a permissible exposure limit. For the purpose of demonstrating compliance with the career limit, NASA has developed a cancer risk projection model for exposure-induced fatal cancer, in which the formulation and numerical values of the quality factor (QFNASA) are substantially different from those of the quality factor (Q) or radiation weighting factor (wR) routinely applied for radiation protection on earth. The quality factor is used to account for the increased effectiveness of radiations of high linear energy transfer (LET), compared to the effectiveness of low-LET γ-rays derived from epidemiological studies of the atomic-bomb survivors. The need for a special approach for space radiation is dictated by the special characteristics of the charged particles from solar radiation and especially the charged particles of high energy and charge (HZE) in galactic cosmic rays (GCR). This article considers aspects of radiation track structure in relation to the relative biological effectiveness (RBE) of HZE particles and the quality factor used for space radiation. The NASA quality factor (QFNASA) is composed of two terms, which can be interpreted as broadly representing the low- and the high-ionization-density components of the HZE particle tracks. These are discussed in turn as they relate to available experimental evidence on the biological effectiveness of such components. Also briefly described are subsequent published proposals for a reformulation of the quality factor to relate more directly to the acute γ-ray exposures from the atomic bombs and for further refinement of the parameter values (and their uncertainties) that determine the shape of the quality factor function. Other recent developments are also mentioned.

Mullenax, Carol A.

A simple parameterization for quality factor as a function of linear energy transfer

The paper presents a simple analytic approximation of the radiation quality factor (Q) as a function of linear energy transfer for use in radiation protection calculations. The paper also presents estimated quality factors in water for protons over a broad range of incident energies. It is shown that the quality factors are less than unity for all proton energies greater than 13 MeV.

Townsend, Lawrence W.

Dose rate, dose-equivalent rate, and quality factor in SLS-1

A tissue-equivalent proportional counter (TEPC) sensitive to the lineal energy range of 0.26-300 keV micrometer-1 was flown on STS-40 (39 degrees x 278 km x 296 km) inside the Spacelab. This instrument was previously flown on STS-31 but was modified to provide a finer resolution at lower lineal energies to better map the South Atlantic Anomaly (SAA) protons. The instrument was turned on 6 June 1991, and operated for 7470 min (124.5 h). The flight duration was characterized by a very large number of X-ray solar flares and enhanced magnetic field fluctuations; however, no significant dose from the solar particles was measured at the location of this instrument. The flight data can be separated into trapped and galactic cosmic radiation parts. The dose rate, dose-equivalent rate and quality factor for trapped radiation were 4.21 +/- 0.03 mrad day-1, 7.72 +/- 0.05 mrem day-1, and 1.83 +/- 0.1, respectively. The dose rate, dose-equivalent rate, and quality factor for galactic cosmic radiation were 5.34 +/- 0.03 mrad day-1, 14.63 +/- 0.06 mrem day-1, and 2.74 +/- 0.1, respectively. The overall quality factor for the flight was 2.38. The dose from the GCR is higher than from SAA protons because of the high inclination and low altitude of this flight. The AP8MAX model of the trapped radiation gives a dose rate of 2.43 mrad day-1 and a quality factor of 1.77. The CREME solar maximum model of galactic cosmic radiation gives a dose rate of 2.54 mrad day-1 and a quality factor of 2.91. Thus the AP8MAX model underestimates the dose by a factor of 1.8 whereas the CREME model leads to an underestimation of the dose by a factor of 2. A comparison of the LET spectra using the AP8MAX model and galactic cosmic radiation transport codes shows only a qualitative agreement.

NASA Discipline Number 00-00

On the evaluation of antenna quality factors

Antenna reactive energies and modal quality factors by compact expressions given in terms of polynomials with positive coefficients not involving spherical Bessel functions

Kalafus, R. M.

On the potential impact of the newly proposed quality factors on space radiation protection

The recently proposed changes in the defined quality factor hold great potential for easing some of the protection requirements from electrons and protons in the near-Earth environment. At the same time, the high Linear Energy Transfer (LET) components play an even more important role which must be further evaluated. Several recommendations are made which need to be addressed before these new quality factors can be implemented into space radiation potection practice.

Wilson, John W.

Realization of high quality production schedules: Structuring quality factors via iteration of user specification processes

This paper describes an architecture for realizing high quality production schedules. Although quality is one of the most important aspects of production scheduling, it is difficult, even for a user, to specify precisely. However, it is also true that the decision as to whether a scheduler is good or bad can only be made by the user. This paper proposes the following: (1) the quality of a schedule can be represented in the form of quality factors, i.e. constraints and objectives of the domain, and their structure; (2) quality factors and their structure can be used for decision making at local decision points during the scheduling process; and (3) that they can be defined via iteration of user specification processes.

Hamazaki, Takashi

Measurement of a high electrical quality factor in a niobium resonator for a gravitational radiation detector

The mechanical and electrical quality factors of a 10-g niobium resonator were measured at 4.4 K and were found to be 8.1 x 10 to the 6th, and 3.8 x 10 to the 6th, respectively. The value for the electrical quality factor is high enough for a system operating at 50 mK at a sensitivity level of one phonon. The resonator's low damping properties make it suitable for use as a transducer for a cryogenic three-mode gravitational radiation detector. A practical design is given for the mounting of the resonator on a 2400-kg aluminum-bar detector. Projections are made for the sensitivity of a 2400-kg bar instrumented as a three-mode system with this resonator inductively coupled to a SQUID.

Folkner, W. M.

Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment.

Kim, Myung-Hee Y.

Laser-Induced Enhancement of Acoustic Mode Quality Factor Revealed by Correlated Single-Particle Optical and Electron Microscopy

Acoustic modes in plasmonic nanostructures provide fundamental insights into their optomechanical behavior at the nanoscale, enabling emerging applications in plasmon-enhanced optomechanics, ultrasensitive sensing, and nanoscale energy transduction. Here we explore the modulation of acoustic phonon dynamics in lithographically fabricated gold nanodisks via laser-induced photothermal annealing. Using a correlated approach that utilizes both single-particle transient extinction spectroscopy and advanced electron microscopy, we directly link nanoscale structural transformations to changes in mechanical properties as probed through the coherence of the excited acoustic modes. Specifically, ultrafast pump–probe microscopy reveals an enhancement in the acoustic mode quality factor of annealed gold nanodisks, indicative of reduced damping and improved vibrational coherence. Structural characterization via scanning electron microscopy and electron backscatter diffraction confirms that photoinduced annealing results in smoother surface morphology and overall enhanced crystallinity. The improved crystalline order reduces defect and crystal boundary scattering, which we suggest as the reason underlying the lower quality factor before annealing. Furthermore, these findings demonstrate that targeted structural engineering at the nanoscale offers a powerful strategy for optimizing the optomechanical performance of plasmonic nanostructures, with broad implications for the design of next-generation nanophotonic and optomechanical systems.

Annealing (metallurgy)

Preliminary Study for a Tetrahedron Formation: Quality Factors and Visualization

Spacecraft flying in tetrahedron formations are excellent for electromagnetic and plasma studies. The quality of the science recorded is strongly affected by the tetrahedron evolution. This paper is a preliminary study on the computation of quality factors and visualization for a formation of four or five satellites. Four of the satellites are arranged geometrically in a tetrahedron shape. If a fifth satellite is present, it is arbitrarily initialized at the geometric center of the tetrahedron. The fifth satellite could act as a collector or as a spare spacecraft. Tetrahedron natural coordinates are employed for the initialization. The natural orbit evolution is visualized in geocentric equatorial inertial and in geocentric solar magnetospheric coordinates.

Guzman, Jose J.

A pilot's assessment of helicopter handling-quality factors common to both agility and instrument flying tasks

A series of simulation and flight investigations were undertaken to evaluate helicopter flying qualities and the effects of control system augmentation for nap-of-the-Earth (NOE) agility and instrument flying tasks. Handling quality factors common to both tasks were identified. Precise attitude control was determined to be a key requirement for successful accomplishment of both tasks. Factors that degraded attitude controllability were improper levels of control sensitivity and damping, and rotor system cross coupling due to helicopter angular rate and collective pitch input. Application of rate command, attitude command, and control input decouple augmentation schemes enhanced attitude control and significantly improved handling qualities for both tasks. The NOE agility and instrument flying handling quality considerations, pilot rating philosophy, and supplemental flight evaluations are also discussed.

Gerdes, R. M.