Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupoles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dependence of nuclear quadrupole resonance transitions on the electric field gradient asymmetry parameter for nuclides with half-integer spins

Allowed transition energies and eigenstate expansions have been calculated and tabulated in numerical form as functions of the electric field gradient asymmetry parameter for the zero field Hamiltonian of quadrupolar nuclides with I=3/2,5/2,7/2, and 9/2. These results are essential to interpret nuclear quadrupole resonance (NQR) spectra and extract accurate values of the electric field gradient tensors. Applications of NQR methods to studies of electronic structure in heavy element systems are proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test Results of the CERN HL-LHC low- Quadrupole Short Models MQXFS3c and MQXFS4

For the High Luminosity Upgrade of the CERN Large Hadron Collider, lower * quadrupole magnets based on advanced Nb3Sn conductors will be installed on each side of the ATLAS and CMS experiment insertion zones. As part of the technological developments needed to achieve the required field gradient of 132.6 T/m within a 150-mm aperture, short length model magnets, named MQXFS, are tested both at the CERN SM18 and FERMI Lab test facilities. The model magnets rely on two types of Nb3Sn conductors (RRP and PIT) and on an innovative bladders and keys design to provide mechanical support against the Lorentz forces. In 2016 and 2017, the powering tests of the first two models MQXFS3 (RRP) and MQXFS5 (PIT) proved that nominal performance (16.5 kA) could be reached with excellent memory of the quench current after thermal cycle. However both magnets showed a slow training behavior with clear observations of voltage disturbances before the quench. Besides MQXFS5 only could reach ultimate current (17.9 kA) whereas erratic behavior was observed on MQXFS3 due to conductor local degradation at the head of one of the coil. In 2018, this limiting coil was changed and the applied azimuthal pre-stress increased. If ultimate current could then be reached, no stable current could be maintained due to identified defect on the outer layer of the new coil. Finally the outcome of the test of the new model MQXFS4, featuring the final RRP conductors that will be used for the series production and variation on the inner layer quench heater designs are here reported in details.

43 PARTICLE ACCELERATORS↗

Summary of Test Results of MQXFS1—The First Short Model 150 mm Aperture Nb 3 Sn Quadrupole for the High-Luminosity LHC Upgrade

The development of Nb 3 Sn quadrupole magnets for the High-Luminosity LHC upgrade is a joint venture between the US LHC Accelerator Research Program (LARP)* and CERN with the goal of fabricating large aperture quadrupoles for the LHC interaction regions (IR). The inner triplet (low-β) NbTi quadrupoles in the IR will be replaced by the stronger Nb3Sn magnets boosting the LHC program of having 10-fold increase in integrated luminosity after the foreseen upgrades. Previously, LARP conducted successful tests of short and long models with up to 120 mm aperture. The first short 150 mm aperture quadrupole model MQXFS1 was assembled with coils fabricated by both CERN and LARP. The magnet demonstrated a strong performance at Fermilab's vertical magnet test facility reaching the LHC operating limits. This paper presents the latest results from MQXFS1 tests with changed prestress levels. The overall magnet performance, including quench training and memory, ramp rate, and temperature dependence, is also summarized.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of the First Short Model 150-mm-Aperture Nb3Sn Quadrupole MQXFS for the High-Luminosity LHC Upgrade

LHC Accelerator Research Program (LARP) and CERN combined their efforts in developing Nb3Sn magnets for the high-luminosity LHC upgrade. The ultimate goal of this collaboration is to fabricate large aperture Nb 3Sn quadrupoles for the LHC interaction regions. These magnets will replace the present 70-mm-Aperture NbTi quadrupole triplets for expected increase of the LHC peak luminosity up to 5 × 10 34 cm -2 s -1 or more. Over the past decade, LARP successfully fabricated and tested short and long models of 90 and 120-mm-Aperture Nb3Sn quadrupoles. Recently, the first short model of 150-mm-diameter quadrupole MQXFS was built with coils fabricated both by LARP and CERN. The magnet performance was tested at Fermilab's vertical magnet test facility. Here, this paper reports the test results, including the quench training at 1.9 K, ramp rate and temperature dependence, as well as protection heater studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of combined function dipole-quadrupole PMQs magnets for NSLS-II upgrade

This paper focuses on the R&D performed for the development of permanent magnets-based dipoles-quadrupoles combined function magnets (PMQs) for the future NSLSII upgrade “complex bend” lattice (CB). This new lattice uses PMQs that provide both bending (dipole) and strong focusing (quadrupole) magnetic field on the electron beam. The permanent magnet (PM) technology is suitable for the high magnetic field strengths (0.5 T, 130 T/m) required for such combine function magnets. PM technology leads to a compact magnet design that is essential in realizing the complex bend lattice concept, as well as a passive magnet solution which does not require electrical power supply reducing power consumption by ~ 80% (from 1.7 MW to 0.3 MW for NSLS-II). Two PMQs magnets designs are under consideration: A hybrid design that use both PM and soft iron poles, and Halbach type that is a pure PM design. Both PMQs designs present challenges in achieving the specified magnetic field quality due to their higher sensitivity to errors (mechanical tolerances and PM properties). This paper presents cost-effective designs and prototypes results for hybrid and Halbach PMQs, addressing various technical challenges while meeting the field requirements of the complex bend lattice for the NSLS-II upgrade.

N'gotta, Patrick [Brookhaven]↗

Tolerance analyses of a quadrupole magnet for advanced photon source upgrade

Given physics requirements, the mechanical fabrication and assembly tolerances for storage ring magnets can be calculated using analytical methods [1, 2]. However, this method is not easy for complicated magnet designs [1]. In this paper, a novel method is proposed to determine fabrication and assembly tolerances consistent with physics requirements, through a combination of magnetic and mechanical tolerance analyses. In this study, finite element analysis using OPERA is conducted to estimate the effect of fabrication and assembly errors on the magnetic field of a quadrupole magnet and to determine the allowable tolerances to achieve the specified magnetic performances. Based on the study, allowable fabrication and assembly tolerances for the quadrupole assembly are specified for the mechanical design of the quadrupole magnet. Next, to achieve the required assembly level tolerances, mechanical tolerance stackup analyses using a 3D tolerance analysis package are carried out to determine the part and subassembly level fabrication tolerances. This method can be used to determine the tolerances for design of other individual magnets and of magnet strings.

43 PARTICLE ACCELERATORS↗

Vertical Magnetic Measurements of the First Full-Length Prototype MQXFAP2 Quadrupole for the LHC Hi-Lumi Accelerator Upgrade Project

This paper reports the commissioning of the vertical magnetic measurement system and the room temperature (warm) and cryogenic (cold) magnetic field measurements of the first full-length (4.2 m) quadrupole built by the U.S. Accelerator Upgrade Project (AUP) (formerly the LARP collaboration) for the high luminosity upgrade of the Large Hadron Collider at CERN. The magnet, designated MQXFAP2, is a prototype preceding production for the AUP which will provide ten sets of 8.4-m superconducting insertion region quadrupoles for the Hi-Lumi Upgrade. The quadrupoles will be built by assembling two 4.2-m magnets in a single cryostat. Agreement between Brookhaven National Laboratory's (BNL's) and Lawrence Berkeley National Laboratory's (LBNL's) warm measurement data has indicated that the upgraded vertical magnetic measurement system at Brookhaven National Laboratory is ready for MQXFA magnet production testing. Lastly, the cold magnetic measurement has been performed and preliminary data analysis has been conducted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Eight piece quadrupole magnet, method for aligning quadrupole magent pole tips

The invention provides an alternative to the standard 2-piece or 4-piece quadrupole. For example, an 8-piece and a 10-piece quadrupole are provided whereby the tips of each pole may be adjustable. Also provided is a method for producing a quadrupole using standard machining techniques but which results in a final tolerance accuracy of the resulting construct which is better than that obtained using standard machining techniques.

43 PARTICLE ACCELERATORS↗

Stretchable Nanolasing from Hybrid Quadrupole Plasmons

This paper reports a robust and stretchable nanolaser platform that can preserve its high mode quality by exploiting hybrid quadrupole plasmons as an optical feedback mechanism. Increasing the size of metal nanoparticles in an array can introduce ultra-sharp lattice plasmon resonances with out-of-plane charge oscillations that are tolerant to lateral strain. By patterning these nanoparticles onto an elastomeric slab surrounded by liquid gain, we realized reversible, tunable nanolasing with high strain sensitivity and no hysteresis. Furthermore, our semi-quantum modeling demonstrates that lasing build-up occurs at the hybrid quadrupole electromagnetic hot spots, which provides a route towards mechanical modulation of light-matter interactions on the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The HL-LHC Low-β Quadrupole Magnet MQXF: From Short Models to Long Prototypes

Among the components to be upgraded in LHC interaction regions for the HiLumi-LHC projects are the inner triplet (or low-β) quadrupole magnets, denoted as Q1, Q2a, Q2b, and Q3. Here, the new quadrupole magnets, called MQXF, are based on Nb3Sn superconducting magnet technology and operate at a gradient of 132.6 T/m, with a conductor peak field of 11.4 T. Q1 and Q3 are composed of magnets (called MQXFA) fabricated by the U.S. Accelerator Upgrade Project (AUP), with a magnetic length of 4.2 m. Q2a and Q2b consist of magnets (called MQXFB) fabricated by CERN, with a magnetic length of 7.15 m. After a series of short models, constructed in close collaboration by the US and CERN, the development program is now entering in the prototyping phase, with CERN on one side and BNL, FNAL, and LBNL on the other side assembling and testing their first long magnets We provide in this paper a description of the status of the MQXF program, with a summary of the short model test results, including quench performance, and mechanics, and an update on the fabrication, assembly, and test of the long prototypes.

43 PARTICLE ACCELERATORS↗

Fabrication of First 4-m Coils for the LARP MQXFA Quadrupole and Assembly in Mirror Structure

The US LHC Accelerator Research Program is constructing prototype interaction region quadrupoles as part of the US in-kind contribution to the Hi-Lumi LHC project. The low-beta MQXFA Q1/Q3 coils have a 4-m length and a 150 mm bore. The design is first validated on short, one meter models (MQXFS) developed as part of the longstanding Nb3Sn quadrupole R&D by LARP in collaboration with CERN. In parallel, facilities and tooling are being developed and refined at BNL, LBNL, and FNAL to enable long coil production, assembly, and cold testing. Long length scale-up is based on the experience from the LARP 90 mm aperture (TQ-LQ) and 120 mm aperture (HQ and Long HQ) programs. A 4-m long MQXF practice coil was fabricated, water jet cut and analyzed to verify procedures, parts, and tooling. In parallel, the first complete prototype coil (QXFP01a) was fabricated and assembled in a long magnetic mirror, MQXFPM1, to provide early feedback on coil design and fabrication following the successful experience of previous LARP mirror tests.

43 PARTICLE ACCELERATORS↗

Mechanical Design Analysis of MQXFB, the 7.2-m-Long Low- $\beta$ Quadrupole for the High-Luminosity LHC Upgrade

As part of the High-Luminosity Large Hadron Collider (LHC) Project, a set of Nb 3 Sn quadrupoles are being developed, aiming to enhance the performance of the inner triplets. The new magnets, identified as MQXFA and MQXFB, will share the same cross section with two different lengths, 4.2 and 7.2 m, respectively. During the magnet development, three short models were tested, along with a number of mechanical models, demonstrating the capability of the magnet cross section to achieve the specified performances. The same performances are now required for the full-length magnets. To ensure this, the authors studied the impact of the magnet length on the capability of the structure to provide an adequate support to the coils. Finite element and simplified analytical models were used to evaluate the impact of the magnet length on the stresses in the magnet ends and coil elongation during powering. Lastly, the models were calibrated using the results from the short model tests, and used to provide an indication on the required prestress and its foreseen impact on the magnet performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical Analysis of the Short Model Magnets for the Nb $_{3}$Sn Low-$\beta$ Quadrupole MQXF

During the development of MQXF, the new Nb 3 Sn quadrupole to be used in the large hadron collider (LHC) inner triplets for the High Luminosity upgrade, three short models were tested: MQXFS1, MQXFS3, and MQXFS5. These models differ in the use of thin or thick laminations for the iron components, in the coil design, and in the superconductive strands, rod restack process (RRP) or powder in tube (PIT). In the MQXF design, the azimuthal prestress is provided at room temperature by means of the bladder-key technology, and it is further increased during the cooldown by the differential thermal contraction of the various components. Four aluminum rods provide the longitudinal prestress. Both systems allow for a flexible control of the amount of prestress applied. As a consequence, it was possible to test the models exploring different azimuthal and longitudinal prestress conditions, in an attempt to understand their impact on the magnet performances. Here, this paper studies the mechanical behavior of these short models, also providing the strain and stresses measured by means of strain gauges installed on the aluminum shell, on the winding poles and on the rods. Finally, the paper compares the measures with the results from finite element (FE) models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geometric Field Errors of Short Models for MQXF, the Nb3Sn Low-β Quadrupole for the High Luminosity LHC

© 2002-2011 IEEE. In the framework of the high-luminosity upgrade of the large hadron collider, the U.S. LARP collaboration and CERN are jointly developing a 150-mm aperture Nb3Sn quadrupole for the Large Hadron Collider (LHC) interaction regions. Due to the large beam size and orbit displacement in the final focusing triplet, MQXF has challenging targets for field quality at nominal operation conditions. Three short model magnets have been tested and around 30 coils have been built, allowing a first analysis of the reproducibility of the coil size and turns positioning. The impact of the coil shimming on field quality is evaluated, with special emphasis on the warm magnetic measurements and the correlation to field measurements at cold and nominal field. The variability of the field harmonics along the magnet axis is studied by means of a Monte-Carlo analysis and the effects of the corrective actions implemented to suppress the low-order unallowed multipoles are discussed.

Bermudez, Susana Izquierdo↗

Quantum phase crossover in the spherical mean-field plus quadrupole–quadrupole and pairing model with two j-orbits

The shape phase crossover in the mean-field plus the geometric quadrupole–quadrupole and pairing model within two [Formula: see text]-orbits is analyzed, for which a simple description of [Formula: see text]Sn confined in the lowest [Formula: see text] and [Formula: see text] orbits above the [Formula: see text]Sn core is demonstrated to reveal the crossover behavior of the model. It is shown that [Formula: see text], [Formula: see text] and [Formula: see text], [Formula: see text] in this case may serve as effective order parameters for even–even and odd-A systems, respectively, from which the shape phase crossover from the rotation-like phase to the superconducting-like phase can be observed with variation of the number of valence neutrons.

Physics↗

Online multi-objective Bayesian optimization of injection efficiency and beam lifetime with skew quadrupoles at NSLS-II

At NSLS-II, the vertical emittance of electron beam is typically blown up to ~30 pm with a coupling wave to increase beam lifetime during user operation. As more and more insertion devices are added to the storage ring, injection efficiency to the ring drops noticeably in certain machine states, apparently due to degraded dynamic apertures. To help alleviate this issue, we have recently performed online multi-objective Bayesian optimization to increase injection efficiency while maintaining beam lifetime, by adjusting the strengths of 15 skew quadrupoles in non-dispersive sections. We report the results of this optimization effort.

Hidaka, Yoshiteru [Brookhaven]↗

Quench Protection of the First 4-m-Long Prototype of the HL-LHC Nb$_3$Sn Quadrupole Magnet

The quadrupole magnets for the LHC upgrade to higher luminosity are jointly developed by CERN and US-LARP (LHC Accelerator Research Program). These Nb3Sn magnets will be protected against overheating after a quench by a combination of heaters bonded to the coil outer surface and CLIQ (Coupling-Loss Induced Quench) units. The first 4 meter long prototype magnet, called MQXFAP1, was tested at the Brookhaven National Laboratory in stand-alone configuration. The magnet training campaign, consisting of 18 quenches, was interrupted due to the development of a short circuit between one heater strip and the coil. During the campaign, different quench protection schemes were implemented, including heaters attached to outer and inner layers, one CLIQ unit, and the energy-extraction system. The configuration including outer-layer heaters and CLIQ achieved the fastest current discharge, hence the lowest hot-spot temperature. The electro-magnetic and thermal transients after a quench were simulated with the program STEAM-LEDET and found in good agreement.

43 PARTICLE ACCELERATORS↗