133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Extraction of high-purity medium-chain-length polyhydroxyalkanoates via combined mechanical treatment and mild oxidation

Polyhydroxyalkanoates (PHAs) are a class of polyester polymers of microbial origin and considered biodegradable alternatives to conventional plastics. To make PHAs cost-competitive with synthetic plastics, their production cost, including extraction cost, should be significantly reduced. Herein, this study aimed to develop an effective extraction method based on combined mechanical disruption and chemical treatment for the recovery of high-purity medium-chain-length PHAs (mcl-PHAs) at a lower cost. mcl-PHAs-accumulating Pseudomonas strains were used for PHA extraction via high-pressure homogenization (HPH) coupled with surfactant treatment and mild alkaline hydrogen peroxide oxidation. The mechanical-chemical method was found to have strong synergy for PHA extraction while minimizing PHA depolymerization. The optimized condition resulted in nearly 90 % mcl-PHA recovery with high purity (>91 %). The extracted high-purity PHAs exhibited thermal and mechanical properties suitable for downstream applications entailing flexible and elastomeric materials.

42 ENGINEERING

Separation and Recovery of High-Purity Dysprosium from Electric Vehicle Scrap Permanent Magnets Using Cyanex 572, a Cationic Extractant in a Membrane Solvent Extraction Process

Rare earth elements (REEs), especially heavy rare earth elements such as dysprosium (Dy), have gained immense attention globally due to their widespread use in many state-of-the-art technologies. Consequently, demand for REEs is increasing rapidly in comparison to their supply. Recycling of REEs from end-of-life (EoL) electronic waste (e-waste) can help to mitigate the increasing gap between the demand and supply of REEs. This study reports the separation and recovery of high-purity Dy from various feedstocks such as scrap permanent magnets (SPMs), electric vehicle (EV) magnets, and mixed rare earth oxides (REOs) using an economically viable and scalable membrane solvent extraction (MSX) process. First, the optimized conditions (organic phase composition and feed solution acid concentration) for the separation of Dy from light REEs such as neodymium (Nd) and praseodymium (Pr) were evaluated using liquid–liquid extraction. Thereafter, a multistage MSX process was developed to separate high purity (>99.5 wt %) Dy from Nd and Pr using Cyanex 572, a cationic extractant. Using feedstocks with varying initial compositions, the MSX process obtained 100% pure Dy with 63–96% Dy recovery in three to six stages with a maximum extraction rate of 2.9 g m–2 h –1 . Purity of the recovered Dy was confirmed via additional characterization such as scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. This novel MSX process holds immense potential for industry deployment for the separation of heavy and light rare REEs from a wide range of e-waste.

electrical vehicle magnets

High Purity and Reduced Defects Hard Carbon Synthesis for Sodium-Ion Batteries

Hard carbon (HC) is the state-of-the-art anode material for sodium-ion batteries; however, the high-temperature carbonization of precursors (>1100 °C) often introduces inorganic impurities, an issue that remains largely underexplored. Here, we report a simple synthesis strategy for producing high purity HC by carbonizing a cellulose-derived precursor at 1400 °C under a slightly reducing Ar–H2 atmosphere on a graphite substrate, thereby eliminating the aluminum contamination observed during conventional carbonization on an alumina substrate under Ar. In addition, the modified synthetic condition reduces surface defects and the concentration of oxygen-containing functional groups, thereby altering the interphase formation on the HC surface. At a current density of 20 mA g−1, the impurity-rich HC exhibited an initial coulombic efficiency (ICE) of 74.1% and a reversible capacity of 248.8 mAh g−1. In sharp contrast, the high purity HC delivered a significantly improved ICE of 90.1% and a reversible capacity of 345.1 mAh g−1. These results underscore the critical importance of impurity and defect control during HC synthesis and highlight the clear electrochemical advantages of high purity HC with reduced defects for sodium-ion battery anodes.

Harshita, Lohanni

Enhanced spectral purity of WSe 2 quantum emitters via conformal organic adlayers

Quantum emitters in solid-state materials are typically embedded in the bulk of their hosts, making their electronic transitions inaccessible to surface modification. In contrast, two-dimensional materials, with their all-surface nature, offer a platform for tuning quantum emitters via chemical functionalization. Because of its semiconducting properties that enable electrical addressability, monolayer WSe 2 is a promising candidate for quantum emission, although the complex interplay between point defects and the localized strain needed to activate quantum emission leads to poor spectral purity. Here, we demonstrate that functionalizing monolayer WSe 2 with conformal adlayers of 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA) improves quantum emission spectral purity. Optical spectroscopy reveals that PTCDA functionalization lowers defect activation energies by 10 meV and induces a 30 nm redshift in quantum emission wavelength, while preserving the bright and dark exciton energies of monolayer WSe 2 . First-principles calculations corroborate these findings, thus providing molecular-level insight into the underlying mechanism of enhanced spectral purity.

Ananth, Riddhi [Northwestern Univ., Evanston, IL (

Blinking compromises the single-photon purity of individual CsPbBr 3 perovskite nanocrystals

Individual lead halide perovskite nanocrystals (PNCs) are promising single photon emitters but often suffer from photoluminescence blinking. Here, we correlate the photoluminescence blinking behavior of CsPbBr 3 NCs with their second-order correlation functions. We find that even moderate band-edge carrier blinking (BC-blinking) can significantly decrease the PNC’s single photon purity, while the impact from Auger blinking is much smaller. Additionally, the degree of BC-blinking can introduce significant uncertainties in single photon purity compared to PNCs with suppressed blinking. Furthermore, we quantitatively correlate the decrease in single photon purity with BC-blinking severity.

36 MATERIALS SCIENCE

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]

Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector

The Short-Baseline Neutrino (SBN) program at Fermilab will pursue neutrino properties searches, exploiting three Liquid Argon Time Projection Chamber (LArTPC) experiments to investigate neutrino oscillations with neutrinos from the Booster Neutrino Beam (BNB). SBND will be the near detector in the program, measuring the un-oscillated flux. It is anticipated to begin operating in 2023. Thanks to its peculiar proximity to the neutrino source of about 110 meters, SBND will collect extremely high statistics data of the flux in the GeV energy range, providing unprecedented precision measurements. SBND particular setting also allows to take measurements at different distances from BNB’s center maintaining statistics high enough at each range. LArTPC and the cold electronics technologies, as well as the argon-neutrino interaction studies, will play a key role in future neutrino physics. In this prospect, this work was focused on two SBND features: SBND PRISM tool, with the aim of investigating neutrino flux at different distances from the beam axis, and Purity Monitors, which provide a clever measurement of argon purity in the detector, whose value is fundamental in neutrino-argon interaction.

43 PARTICLE ACCELERATORS

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La

The impact of nickel concentration and stacking fault energy on deformation mechanisms in high-purity austenitic Fe-Cr-Ni alloys

Understanding how composition affects deformation mechanisms in austenitic stainless steels is essential for developing accurate predictive models of stress-induced failures and stress corrosion cracking. Nickel (Ni), an element classified as a critical element, plays a crucial role in these processes. It is important to examine how Ni concentration influences stacking fault energy (SFE) and, consequently, the deformation mechanisms of austenitic stainless steels. However, in commercial stainless steels, the effects of other alloying elements and impurities can obscure Ni's role, complicating efforts to isolate its impact. Here, in this study, we use two high-purity Fe-Cr-Ni alloys to investigate how Ni concentration and SFE interact to alter deformation mechanisms and induce martensitic transformation. By combining in situ synchrotron X-ray diffraction (XRD) tensile testing and post-mortem electron microscopy with density functional theory simulations, we gain precise insights into these phenomena. We find that the Fe18Cr10Ni (wt%) alloy, with its low SFE, exhibits higher stacking fault probability, deformation-induced martensitic transformation, and a lesser increase in dislocation density with plastic strain. In contrast, the Fe18Cr14Ni (wt%) alloy, with its higher SFE, shows enhanced deformation twinning and greater dislocation density with increasing strain. These findings from high-purity ternary alloys provide valuable insights that can guide the search for alternative elements to replace Ni while achieving similar effects on phase stability and deformation behavior.

36 MATERIALS SCIENCE

Experimental investigation of the dependence of void nucleation and growth on initial microstructure in high-purity titanium under tension

An experimental investigation of failure mechanisms in relation to the initial microstructure in high-purity titanium samples is presented. The initial microstructure of the specimens was measured in 3D using diffraction-contrast tomography (DCT). Ex-situ X-ray computed tomography (XCT) was used to visualize voids in specimens at various levels of deformation attained by interrupted tensile testing. Electron backscatter diffraction (EBSD) mapping was used to characterize the deformed microstructures per specimen. The investigation showed that the location of failures was unrelated to the formation of the first voids, but rather the nucleation and growth of cracks were from heavily deformed surface regions. The areas surrounding the failure-causing cracks had the highest propensity for void development of any area in the specimen. This facilitated crack propagation through the specimen via “linking up”. The failure of the specimens by microvoid coalescence was bolstered by “dimpled” fracture surfaces. Paint composed of gallium embedded in rubber was used to track the displacement of points along the loading direction of the specimens, to relate the location of failure to the material's initial microstructure. However, the correlation proved difficult, due to complex microstructural evolution involving voids, grain fragmentations, and profuse twinning. Nevertheless, it was shown that necking occurred near the largest grain in the gauge section of the specimens. This is likely caused by the decrease in strength of larger grains, causing strain to concentrate in their vicinity. Here, a comprehensive picture of the failure processes in high-purity titanium under axial loading is presented and discussed in the paper.

36 MATERIALS SCIENCE

High-Purity Quantum Emission from an Au 24 (S-CH 2 Ph- t Bu) 20 Nanocluster at Room Temperature

Atomically precise gold nanoclusters have garnered significant attention for their diverse applications, ranging from biological labeling to optoelectronics. Their potential in optical quantum computing, which calls for ideal single-photon sources, has recently become a key area of interest. In the current work, we use photon antibunching experiments to explore the single-photon emission efficiency of atomically precise Au 24 nanoclusters protected by 4-tert-butylbenzyl mercaptan ligands (Au 24 (TBBM) 20 ). This cluster exhibits quantum emission with good photostability and without any observable blinking or spectral drift at room temperature under an inert gas atmosphere, with antibunching dips (g 2 (0)) as low as 0.07 in the solid state or, equivalently, a single-photon purity of 93% under time-gated conditions. Transient absorption and time-gated antibunching studies reveal that the short emission lifetime of this cluster and its high photoluminescence quantum yield in the solid state play critical roles in enhancing the emitted single-photon purity. This research advances the understanding of single-emitter behavior in atomically precise gold nanoclusters, contributing to the development of stable quantum emitters that are essential for quantum computing and cryptography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090

Qubit-state purity oscillations from anisotropic transverse noise

We explore the dynamics of qubit-state purity in the presence of transverse noise that is anisotropically distributed in the Bloch-sphere X Y plane. We perform Ramsey experiments with noise injected along a fixed laboratory-frame axis and observe oscillations in the purity at twice the qubit frequency arising from the intrinsic qubit Larmor precession. We probe the oscillation dependence on the noise anisotropy, orientation, and power spectral density, using a low-frequency fluxonium qubit. Our results elucidate the impact of transverse noise anisotropy on qubit decoherence and may be useful for disentangling charge and flux noise in superconducting quantum circuits. Published by the American Physical Society 2025

Rower, David A. (ORCID:0000000328455616)

Room-temperature high-purity single-photon emission from carbon-doped boron nitride thin films

Hexagonal boron nitride (h-BN) has emerged as a promising platform for generating room temperature single photons exhibiting high brightness and spin-photon entanglement. However, improving emitter purity, stability, and scalability remains a challenge for quantum technologies. Here, we demonstrate highly pure and stable single-photon emitters (SPEs) in h-BN by directly growing carbon-doped, centimeter-scale h-BN thin films using the pulsed laser deposition (PLD) method. These SPEs exhibit room temperature operation with polarized emission, achieving a g (2) (0) value of 0.015, which is among the lowest reported for room temperature SPEs and the lowest achieved for h-BN SPEs. It also exhibits high brightness (~0.5 million counts per second), remarkable stability during continuous operation (>15 min), and a Debye-Waller factor of 45%. First-principles calculations reveal unique carbon defects responsible for these properties, enabled by PLD’s low-temperature synthesis and in situ doping. Our results demonstrate an effective method for large-scale production of high-purity, stable SPEs in h-BN, enabling robust quantum optical sources for various quantum applications.

36 MATERIALS SCIENCE

Production of High Yield, Ultra‐Shallow Nitrogen‐Vacancy Centre Ensembles Through High Purity Forming gas Annealing

Dense, ultra‐shallow (<10 nm from the surface) ensembles of nitrogen‐vacancy (NV) centers in diamond are sought‐after for realising practical quantum sensing at the nanoscale. However, these ensembles typically suffer from reduced NV creation efficiency and spin coherence compared to their deeper and bulk counterparts. Consequently, most demonstrations in the literature to date have been restricted to using single NV centers with atypical coherence and charge stability properties not achievable across entire ensembles. Here, in this work, we demonstrate that controlled annealing in a high purity forming gas atmosphere improves near‐surface NV formation efficiency to over 20%. This environment preserves a high quality hydrogen termination throughout the anneal, avoiding material etching over many hours at temperatures up to 1100°C and possibly helping to suppress vacancy out‐diffusion. We show that high temperature annealing is especially vital for improving spin properties in high density, ultra‐shallow implanted samples due to the localised damage profiles produced. By allowing the formation of high yield NV ensembles with improved spin properties, the optimised forming gas anneal can facilitate the reliable production of more sensitive diamond sensors than have previously been accessible.

Healey, Alexander J. [Royal Melbourne Institute of