Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumped hydro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Basic Design Layout of a Modular Pumped Hydro Teaching Unit

This work was originally completed in July 2015 as a proposal to Santa Fe Community College (SFCC) for their engineering program and a follow up to a feasibility study completed for the Community College the year earlier as indicated below. The work was ahead of its time and funding was hard to obtain to implement a project. This work is now being formally released for distribution to a wider audience based on the evolving circumstances in greater society that now favor this approach with funding more readily available. Due to the distribution outside of SFCC, specific architectural drawing sets of the pertinent buildings called out in the design have been removed. No changes to the design have been made. The design layout utilizing a building is not meant to limit the implementation of the design. The elevation difference required may be obtained with a building, a small hill, jacking up the upper tank, or similar means. The design presented is a basic design, identifying major components and how they are connected together. The user may change components under their own liability. All local applicable codes and standards must be followed when building an actual unit, under the authority of a responsible engineer or owner. Appropriate measures must be followed to protect people from hazards such as electricity, water pressure, and general construction. A leak test to verify water tightness of the system should be conducted prior to any operations. The vision of this design is to allow a class of 10 to 15 students to construct the assembly within a month or so time period, and then learn to operate the assembly at their school location under the guidance of their instructor. This will allow the students to learn about the practical concept of storing electricity with water, and gain a hands on experience of the real world challenges faced with full Modular Pumped Hydro Projects.

13 HYDRO ENERGY↗

Preliminary Hyde Memorial State Park Modular Pumped Hydro Energy Storage Sizing Study

Hyde Memorial State Park has lost grid supplied power and has been running on a diesel generator for some time now. The powerline that feeds the park is a state owned, 5 mile underground extension from the PNM service connection point. The line has decayed over the past 30 plus years and due to the location (much of it running under the road) the cost of repair and the logistics of closing the road are not good options. In June 2019 through a state contractor, the State of New Mexico Energy, Minerals and Natural Resources Department completed a renewable energy microgrid feasibility study to see if it was technically and economically feasible to operate the park without future grid power. The study looked at solar plus battery storage and a propane generator as a possible option. New Mexico State Parks Division has indicated their wish to move forward with the microgrid project which will now go out to one of the state’s energy services performance contractors. The contractor will have to finalize the feasibility study and develop a complete list of construction costs. Given, the lack of long-term O&M data on the battery, as part of the next phase of the project the State of New Mexico Energy, Minerals and Natural Resources Department asked Los Alamos National Laboratory to preliminary examine the potential for pumped hydro as an alternative to batteries.

13 HYDRO ENERGY↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tool-Based Case Studies on Strategic Deployment of Untapped Micro-Pumped Hydro Storage in Michigan

With most classical hydropower sites already utilized and the global push for rapid integration of renewable energy sources accelerating, there is a critical need to identify alternative energy storage solutions. Pumped hydro energy storage, which accounts for the vast majority of global grid-scale storage, remains one of the most cost-effective and long-duration storage technologies available. Hence, this study presents a novel tool designed to assess the untapped potential of inland lakes and reservoirs for micro-PSH, using Michigan’s relatively flat landscape as a case study due to its extensive but underutilized water infrastructure. To ensure accuracy and reliability, the tool incorporates extensive data gathered from authorized sources, covering more than 420 water facilities and potential reservoirs in the state. The tool evaluates key parameters such as horizontal and vertical distances, volume, and the total storage capacity of each reservoir. Its robust assessment framework integrates these metrics to evaluate each site’s potential. The tool’s intuitive interface and geospatial visualizations support actionable insights for planners and scalable deployment of distributed storage infrastructure.

13 HYDRO ENERGY↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

BI-LEVEL OPTIMIZATION FOR ELECTRICITY TRANSACTION IN SMART COMMUNITY WITH MODULAR PUMP HYDRO STORAGE

Grid integration of the increasing distributed energy resources could be challenging in terms of new infrastructure investment, power grid stability, etc. To resolve more renewables locally and reduce the need for extensive electricity transmission, a community energy transaction market is assumed with market operator as the leader whose responsibility is to generate local energy prices and clear the energy transaction payment among the prosumers (followers). The leader and multi-followers have competitive objectives of revenue maximization and operational cost minimization. This non-cooperative leader-follower (Stackelberg) game is formulated using a bi-level optimization framework, where a novel modular pump hydro storage technology (GLIDES system) is set as an upper level market operator, and the lower level prosumers are nearby commercial buildings. The best responses of the lower level model could be derived by necessary optimality conditions, and thus the bi-level model could be transformed into single level optimization model via replacing the lower level model by its Karush-Kuhn-Tucker (KKT) necessary conditions. Several experiments have been designed to compare the local energy transaction behavior and profit distribution with the different demand response levels and different local price structures. The experimental results indicate that the lower level prosumers could benefit the most when local buying and selling prices are equal, while maximum revenue potential for the upper level agent could be reached with non-equal trading prices.

Chen, Yang↗

Technoeconomic Studies for the Rorex Creek Pumped Storage Hydro Project: An Evaluation of New Pumped Storage Hydro in the Tennessee Valley Authority System

This report evaluates the economic viability of the proposed 1,200 MW, 23,365 MWh Rorex Creek Pumped Storage Hydro (PSH) plant that would be located near Pisgah, Alabama. In addressing this question, this study has developed processes, models and data that better value PSH from a utility perspective, more specifically a vertically integrated utility, enabling optimal PSH design and deployment. This study is designed to enhance TVA’s toolset in making PSH investment decisions and contribute to the design of a more cost-effective, stable future grid. These techniques can then be applied to a broader range of assets and utilities.

Cohen, Stuart↗

Regenerative Fuel Cell System (Cooperative Research and Development Final Report, CRADA Number CRD-16-635)

Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.

13 HYDRO ENERGY↗

A Configuration Based Pumped Storage Hydro Model in the MISO Day-Ahead Market

Pumped storage hydro units (PSHU) can provide flexibility to power systems. This becomes particularly valuable in recent years with the increasing shares of intermittent renewable resources. However, due to emphasis on thermal generation in the current market practices, the flexibility from PSHUs have not been fully explored and utilized. This paper proposes a configuration based pumped storage hydro (PSH) model for the day-ahead market, in order to enhance the use of PSH resources in the system. A strategic design of incorporating and fully optimizing PSHUs in the day-ahead market is presented. Here, we show the compactness of the proposed model. Numerical studies are presented in an illustrative test system and the Midcontinent Independent System Operator (MISO) system.

13 HYDRO ENERGY↗

Pumped Storage Hydro Model Evaluation Report Task 1: Tool Assessment

Pumped storage hydro (PSH) projects support various aspects of power system operations. However, determining the value of PSH projects and the many services and contributions to the system they provide can be a challenge. The PSH techno-economic studies being carried out by a 5-lab consortium are defining extensive modeling approaches for evaluating the economic benefits of PSH projects. To enhance the impact of the valuation approach and follow-on techno-economic studies, Pacific Northwest National Laboratory (PNNL) will be developing a set of online tools that industry could adopt and use to advance PSH projects in the US. The problem is that the research team is not entirely clear on the features of the tools that would offer the most significant impact to industry. Thus, year one of this effort is designed to first define the needs of industry before developing the PSH valuation tool. The first step in defining industry needs is to evaluate existing tool packages, including those created by DOE and those by industry groups, to both measure usage levels and define tool attributes that maximize industry impact. The second step in this process will be to hold a workshop designed to elicit direct industry input. Given the breadth and nature of the task, which is to define ideal model attributes, the research team did not constrain the assessment to storage valuation tools. Several tools were assessed, and their characteristics compared against a list of “ideal” attributes that included ease of use, generalizability of results, and analytical flexibility. Information regarding usage and impact were then compared to specific model attributes to define which attributes appear to drive success. The following key lessons and implications can be drawn from the analysis: Models with high ease of use were often the most adopted by industry, though they did not necessarily have high publication reference records, meaning a published article made direct reference to the tool. For example, REScheck TM and COMcheck TM , two tools which share a site, have seen a high amount of web traffic and usage. Similarly, Storage Value Estimate Tool (StorageVET®), an energy storage valuation model, has a large number of organizations using it despite a low publication reference record. A common feature between these models is that they are web-hosted, theoretically making them more easily accessible with graphic user interfaces (GUIs) that are more navigable; Models with higher usage statistics were typically free and/or open source. While it may be unsurprising that this attribute could be considered a draw for users, there is the potential for overestimating the tool's value based on popularity due to the fact that some users may have used the model simply because it was free and not because it is the best model; Models that offer more in-depth analysis and a wide coverage of applications (e.g. VOLTTRON™, GridLAB-D™, and Integrated Valuation of Ecosystem Services and Tradeoffs (InVest)) have shown a high number of publication references as well as showing a high number of downloads in the case of GridLAB-D™. It should be noted that the figure below does not include the model with the highest number of publication references (EnergyPlus™) as it has been removed to show clearer distinction between the remaining tools; The most popular model within the evaluation list was EnergyPlus™. This tool has the highest number of publication references (2,034) of all models considered and contains both a high ease of use level as well as broad application flexibility. Its high usage may be correlated, however, with the presumed wider audience conducting energy consumption modeling compared to the audiences for some of the other tools in this list; Models that were low in both general usage and publication reference generally did not exhibit characteristics considered ideal by the research team. Some of these models offered a narrower range of analytical applications or lower generalizability of results. This would automatically restrict the pool of potential users to those who fall within a narrow range of specific technologies or applications. This report also explores two model structures for the PSH tool: decision tree-based, which would guide the user through the valuation methods defined in the PSH techno-economic studies currently being carried out by DOE, and an all-inclusive comprehensive model. The strengths of each were explored and a hybrid approach was defined that would embed a price taker model into the decision tree approach. Such an approach would provide a comprehensive approach for modeling small-scale PSH while recognizing the challenges associated with implementing a price-maker approach in an all-inclusive model. Insight gained in this analysis of other models can aid in narrowing down the list of effective and sought-after attributes, and in defining model structure. Next steps toward developing a model for storage valuation will be to gain direct industry input through workshops.

13 HYDRO ENERGY↗

Modeling State Transition and Head-Dependent Efficiency Curve for Pumped Storage Hydro in Look-Ahead Dispatch

As one of the most widely installed utility-scale storage facilities, pumped storage hydro (PSH) plays an essential role in providing flexibility for power systems worldwide. Thus, to accurately quantify the flexibility of PSH units in operational optimization problems is important. The conventional PSH models in the literature rarely consider detailed state transitions due to their hourly-based settings. However, it becomes imperative for operational optimization on short-term intervals, especially with increasing shares of renewable energy in power systems. To this end, this paper presents a novel deterministic PSH model that considers the transition time and trajectory between three states of PSH units in look-ahead dispatch. Moreover, to better characterize the varying efficiency of PSH units with water head and flow rate, this paper proposes to model detailed headdependent efficiency curves (hereafter called input-output curves) in look-ahead dispatch, which encounters heavy computational burdens when short time intervals are applied. In this work, a zig-zag piece-wise linear approximation method is used for input-output curve modeling. This can enable an accurate quantification for variable efficiency and head dependence in a computationally effective manner. Here, numerical results are presented to show performances of the proposed PSH model in both flexibility quantification and computation time.

13 HYDRO ENERGY↗

Value and Role of Pumped Storage Hydro under High Variable Renewables

A project team, led by GE Research, was tasked by the U.S Department of Energy (DOE) to study the value and role of pumped storage hydro (PSH) under high variable renewables. The study was majority funded by DOE’s Office of Energy Efficiency and Renewable Energy (EERE) through a program managed by EERE’s Water Power Technologies Office. The project team for the study consists of three organizations – GE Research, GE Energy Consulting, and GE Renewables.

13 HYDRO ENERGY↗

Repurposing Inactive Oil and Gas Wells for Energy Storage: Maximizing the Potential Via Optimal Drivetrain Control: Preprint

In recent years, there has been a growing emphasis on utilizing energy storage to enhance grid resilience against disruptive events. While renewable energy supply continues to expand, gravity-based solutions like pumped hydro remain dominant in the commercial space. However, their geographical limitations constrain availability, scalability, and increase costs for co-locating solar and wind energy. An alternative approach proposes repurposing idle oil and gas wells located closer to existing grid infrastructure, offering a promising and cost-effective solution. This paper addresses the optimization and control of a regenerative drive system coupled to an interior permanent magnet synchronous machine in a 300-meter well with a 100-Newton weight. The study employs a dynamic MATLAB/Simulink model to simulate the operation of the electric drivetrain system during storage and discharge operations. The results demonstrate an initial round-trip efficiency of 85.9% for the electrical system alone and identify crucial factors for maximizing efficiency. The optimized operation and control of the electromechanical drivetrain system hold great potential for minimizing the levelized cost of storage while maximizing efficiency and revenue generation.

ENERGY STORAGE,ENGINEERING↗

ORNL Hydropower Cost Database Extract from FERC Form-1

The ORNL FERC Form 1 Hydropower Cost Database Extract is a cleaned and compiled version of the hydropower component of the Federal Energy Regulatory Commission’s (FERC) Electric Utility Annual Report, also known as Form-1. The database includes conventional and pumped storage hydropower plants owned by non-federal major utilities that submitted the Form 1 data from 1994-2020, representing about 22% of existing conventional hydropower capacity and 61% of pumped storage capacity. The database includes the escalation factors and describes the methods used to scale costs to a common data year, as well as tables of identifiers necessary to link the hydropower plants to two other relevant databases, the National Inventory of Dams and the ORNL Existing Hydropower Assets database. This database provides historical capital and operating costs for three schedules/classes defined in Form 1: Large Hydro, Pumped Storage Hydro, and Small Hydro. The Large Hydro and Pumped Storage Hydro data include cost items, such as land, structures, facilities, etc.

13 HYDRO ENERGY↗

Geomembranes for Pumped Storage Hydro

Energy storage is fundamental to ensuring the reliability, stability, and resilience of the grid, essential for meeting the energy demands now and in the future. Pumped storage stands out as a proven energy storage solution. There are 43 pumped-storage plants operating in the USA today, and they offer unparalleled scalability, rapid-response capabilities, and long-term reliability at a competitive cost. With a history of successful operation spanning decades, and approximately 60 sites proposed at various stages of permitting and development, this technology is a critical component for the US energy sector. However, its development involves some complex engineering and regulatory challenges.

13 HYDRO ENERGY↗

Nonexhaustive Taxonomy of Hydropower and Pumped Storage Hydro Facilities [Slides]

The National Renewable Energy Laboratory (NREL) has published benchmark technical reports and presentations that disaggregate major product components for a variety of technologies, including land-based and offshore wind, photovoltaic, and battery energy storage systems. NREL has partnered with staff from the Pacific Northwest National Laboratory (PNNL) and members of the U.S. Department of Energy's Water Power Technology Office (WPTO) to create a non-exhaustive taxonomy of the major products and components of hydropower and pumped storage systems.

13 HYDRO ENERGY↗