Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗

Distribution System State Estimation With High Penetration of Demand Response Enabled Loads

Demand-side operations incentivize utility customers to take part in various grid services. A demand response enabled load (DREL) is a flexible grid asset that schedules electricity consumption in response to a time-of-use (TOU) energy price. Consequently, its energy profile differs from that of a conventional load that is insensitive to price. This difference may cause new challenges for distribution system state estimation (DSSE). It is well known that DSSE often needs to use pseudo-measurements based on historic load profiles to increase system observability. However, historic profiles of conventional loads are not representative of DREL behaviors. Additionally, the inaccuracy impacts DSSE results and other DSSE-dependent operations. In this paper, we propose an online pseudo-measurement generation approach for DSSE with DRELs. We formulate an optimization model to represent DRELs self-adjusting actions. Sampling-based stochastic optimization techniques are proposed to account for uncertainties in DRELs. A set of representative DREL behavior data corresponding to the samples are used to characterize DREL pseudo-measurements. Case studies with modified IEEE 123-bus test system verify the validity of the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Fidelity Gaussian Process for Distribution System Voltage Probabilistic Estimation with PVs

The increasing penetration of behind-the-meter PVs causes challenges to maintain voltage security due to the lack of distribution system visibility. This paper proposes a nonlinear autoregressive Gaussian process (NARGP) approach to fuse limited number of SCADA/AMI data together with historical pseudo measurements for distribution node voltage probabilistic estimation. The high-fidelity SCADA data are fused with the low-fidelity AMI and pseudo measurements by the autoregressive algorithm embedded in the Gaussian process. This allows us to use multi-fidelity data to achieve entire distribution system voltage visibility. Numerical results carried out on the IEEE 123node system demonstrate that the NARGP method is able to obtain high accuracy in estimating bus voltage and quantifying estimation uncertainties as compared to other approaches.

distribution system estimation↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

Real-Time Distribution System State Estimation with Asynchronous Measurements

We report state estimation is a fundamental task in power systems. Although distribution systems are increasingly equipped with sensing devices and smart meters, measurements are typically reported at different rates and asynchronously; these aspects pose severe strains on workhorse state estimation algorithms, which are designed to process batches of data collected in a synchronous manner from all the measurement units. In this paper, we develop a novel state estimation algorithm to continuously update the estimate of the state based on measurements received in an asynchronous manner from measurement units. The synthesis of the algorithm hinges on a proximal-point type method, implemented in an online fashion, and capable of processing measurements received sequentially from sensors. A performance analysis is presented by providing bounds on the estimation error in terms of the mean and variance that hold at each iteration and asymptotically. The scheme is also compared with a more traditional Weighted Least Squares estimator that compensates for the lack of measurement data by using, as pseudo measurements, the measurement retrieved during a certain time window. Numerical simulations on the IEEE 37-bus feeder corroborate the analytical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital twin advanced distribution management systems (ADMS) and methods

Advanced Distribution Management Systems not generally optimize over the entire feeder because there are few high-fidelity distribution circuit models and real-time distribution-connected sensors are rare. The limited observability at the distribution level makes it difficult to globally optimize distribution operations and issue control setpoints to power systems equipment or Distributed Energy Resources (DER) to perform grid-support services. For example, setpoints can be issued to DER based on results from an optimization module that incorporates a static or time-series feeder simulation. Feeder simulation initial conditions are populated with photovoltaic (PV) and load forecasts, state estimation results, and/or digital twin measurements or state output. The real-time (RT) digital twin runs a model of the feeder to generate state estimation pseudo-measurements since there are limited live feeder measurements.

Johnson, Jay Tillay↗

Solving Optimal Power Flow for Distribution Networks with State Estimation Feedback

Conventional optimal power flow (OPF) solvers assume full observability of the involved system states. However in practice, there is a lack of reliable system monitoring devices in the distribution networks. To close the gap between the theoretic algorithm design and practical implementation, this work proposes to solve the OPF problems based on the state estimation (SE) feedback for the distribution networks where only a part of the involved system states are physically measured. The SE feedback increases the observability of the under-measured system and provides more accurate system states monitoring when the measurements are noisy. We analytically investigate the convergence of the proposed algorithm. The numerical results demonstrate that the proposed approach is more robust to large pseudo measurement variability and inherent sensor noise in comparison to the other frameworks without SE feedback.

distirbution systems↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Feasibility of Correlation-Aware Inference and Universal Precision Scaling in Bonse–Hart Ultra-Small-Angle Neutron Scattering

Bonse–Hart ultra-small-angle neutron scattering (USANS) provides access to micrometre-scale structure, but useful measurements often require long counting times. In this work, we test whether the expected smoothness of the scattering profile can be exploited to improve data quality at lower counting statistics. We apply a Gaussian-process-based method to Bonse–Hart USANS data and evaluate its performance on pseudo-measurements generated from high-statistics experiments under Poisson statistics. This provides a stringent test of how well the underlying I(Q) profile can be reconstructed when the available counts are substantially reduced. We further show that, in the counting-limited regime, the reconstruction error follows a universal scaling behaviour that differs from the usual independent-counting expectation. At higher counts, the improvement crosses over to a resolution-limited regime set by analyser-angle discretization and rocking-curve width. These results clarify when correlation-aware inference is useful in USANS and provide a practical basis for improving measurement efficiency and beam-time usage.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Explainable multi-fidelity Bayesian neural network for distribution system state estimation

Distribution System State Estimation (DSSE) is frequently constrained by limited real-time measurements, the uncertainties introduced by distributed energy resources, and the presence of bad data. To address them, this paper proposes an enhanced Multi-Fidelity Bayesian Neural Network (MFBNN) DSSE approach. A low-fidelity layer based on a Deep Neural Network (DNN) is first pre-trained on pseudo-measurement data to learn fundamental state features. Subsequently, a high-fidelity Bayesian Neural Network (BNN) layer leverages limited but high-quality real-time measurements to refine these features, thereby achieving accurate DSSE. Additionally, the deep SHapley Additive exPlanation (SHAP) is developed to quantify the influence of measurement data on DSSE through dual perspectives of global feature importance and local nodal contributions, establishing a hierarchical explainability framework for machine learning-based DSSE. Comparative studies conducted on the IEEE 13-bus system and a real-world 2135-node system from Dominion Energy demonstrate that the proposed method excels in estimation accuracy, even under situations of high noise levels, bad data, and missing data. Further comparisons with Weighted Least Squares (WLS) and other machine learning-based DSSE approaches verify that the proposed framework offers higher accuracy, improved interpretability, and enhanced robustness.

Bad data↗

Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources

Power distribution systems are increasingly integrating heterogeneous sensors with varying data reporting rates and types, which pose challenges to achieving observability at the desired temporal resolution of distribution system state estimation (DSSE). Multisensor failures caused by extreme events exacerbate these issues, introducing substantial uncertainties into DSSE. This article proposes a novel solution to these challenges by ensuring high-resolution system observability despite heterogeneous data sources and multisensor failures. First, a deep learning architecture combining long short-term memory (LSTM) and graph convolutional network (GCN) is employed to synchronize meters with different reporting rates, aiming to achieve system observability. A random-walk-model-based approach is introduced to generate pseudo-measurements while properly characterizing their uncertainties under multisensor failures. Finally, a disaster-risk-informed observability metric (RiOM) is defined to quantify the uncertainty associated with state estimation results. The proposed framework offers deeper insights into the system observability on the fly compared with conventional analysis. The effectiveness of the framework is demonstrated on an IEEE standard test case and a large-scale real-world distribution feeder in mid-Minnesota in the U.S.

97 MATHEMATICS AND COMPUTING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 10: Controllability and Observability Analysis (Deliverable D7))

It is common to have less than full observability for distribution systems, as the number of available measurements are not sufficient. Considering increasing penetration of distributed energy resources (DERs), it is imperative to understand and control distribution systems better. Developed for the transmission system, the original numerical observability analysis methods were based on the canonical DC Power Flow (DC-PF) model. However, the DC-PF model is ill-suited for the distribution system in which line resistance to reactance (R/X) ratios can be near unity. In this report, we apply the non-iterative Observability Test (OT) and Observable Island Identification Procedure (OIIP) in to the gain matrix from the distribution system state estimator. Because sensors are few in distribution systems, pseudo-measurements based on historical load profiles and zero-injection virtual measurements are often employed to ensure observability. However, both the observability and the accuracy of the state estimates are uncertain when historical data is limited/unavailable.

42 ENGINEERING↗

System state estimation with asynchronous measurements

The present disclosure provides techniques for estimating network states using asynchronous measurements by leveraging network inertia. For example, a device configured in accordance with the techniques of the present disclosure may receive electrical parameter values corresponding to at least one first location within a power network and determine, based on the electrical parameter values and a previous estimated state of the power network, an estimated value of unknown electrical parameters that correspond to a second location within the power network. The device may further cause at least one device within the power network to modify operation based on the estimated value of the unknown electrical parameters. The leveraging of network inertia may obviate the need for probabilistic models or pseudo-measurements.

Cavraro, Guido↗