Medical Proton Test Facilities (MPTFs) Lessons Learned on the Unique Aspects for Single Event Effects (SEE) Testing of Electronics in the 200 MeV Regime

Ever since the closure of the Indiana University Cyclotron Facility (IUCF) in 2014, there has been an increasing use of medical proton therapy facilities (MPTF) for SEE testing with protons in the 200 MeV or greater regime. This talk covers some of the unique features and considerations for utilizing MPTFs including both logistical and technical aspects. This presentation provides an overview of lessons learned for SEE testing at MPTFs.

Medical Proton Test Facilities (MPTFs)↗

Proton Testing of nVidia Jetson TX1

Single-Event Effects (SEE) testing was conducted on the nVidia Jetson TX1 System on Chip (SOC); herein referred to as device under test (DUT). Testing was conducted at Massachusetts General Hospitals (MGH) Francis H. Burr Proton Therapy Center on October 16th, 2016 using 200MeV protons. This testing trip was purposed to provide a baseline assessment of the radiation susceptibility of the DUT as no previous testing had been conducted on this component.

Proton testing↗

Proton Testing of nVidia GTX 1050 GPU

Single-Event Effects (SEE) testing was conducted on the nVidia GTX 1050 Graphics Processor Unit (GPU); herein referred to as device under test (DUT). Testing was conducted at Massachusetts General Hospitals (MGH) Francis H. Burr Proton Therapy Center on April 9th, 2017 using 200-MeV protons. This testing trip was purposed to provide a baseline assessment of the radiation susceptibility of the DUT as no previous testing had been conducted on this component.

Proton testing↗

Proton Testing of nVidia GTX 1050 GPU, Part 2

Single-Event Effects (SEE) testing was conducted on the nVidia GTX 1050 Graphics Processor Unit (GPU); herein referred to as device under test (DUT). Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on April 28th, 2018 using 200-MeV protons. This testing trip was purposed to provide additional radiation susceptibility data from payloads compiled in Q3FY18. While not all radiation-induced errors are critical, the effects on the application need to be considered. More so, failure of the device and an inability to reset itself should be considered detrimental to the application. Radiation effects on electronic components are a significant reliability issue for systems intended for space.

Single-Event Effects (SEE)↗

Proton Testing of AMD v1202b System on Chip

Single-Event Effects (SEE) testing was previously conducted on the AMD v1200 System on Chip (SoC) at Massachusetts General Hospital’s (MGH) Francis H. Burr Proton Therapy Center on May 28, 2022, using 200-MeV protons.

Edward J Wyrwas↗

Heavy-ion radiobiology: new approaches to delineate mechanisms underlying enhanced biological effectiveness

Shortly after the discovery of polonium and radium by Marie Curie and her husband and colleague, Pierre Curie, it was learned that exposure to these alpha-particle emitters produced deleterious biological effects. The mechanisms underlying the increased biological effectiveness of densely ionizing radiations, including alpha particles, neutrons and highly energetic heavy charged particles, remain an active area of investigation. In this paper, we review recent advances in several areas of the radiobiology of these densely ionizing radiations, also known as heavy ions. Advances are described in the areas of DNA damage and repair, chromosome aberrations, mutagenesis, neoplastic transformation in vitro, genomic instability, normal tissue radiobiology and carcinogenesis in vivo. We focus on technical innovations, including novel applications of pulsed-field gel electrophoresis, fluorescence in situ hybridization (FISH), linkage analysis, and studies of gene expression and protein expression. We also highlight the use of new cellular and animal systems, including those with defined DNA repair deficiencies, as well as epithelial cell model systems to assess neoplastic transformation both in vitro and in vivo. The studies reviewed herein have had a substantial impact on our understanding of the genotoxic effects of heavy ions as well as their distinct effects on tissue homeostasis. The use of these radiations in cancer therapy is also discussed. The use of both heavy-ion and proton therapy is on the upswing in several centers around the world, due to their unique energy deposition characteristics that enhance the therapeutic effect and help reduce damage to normal tissue.

Review, Academic↗

Stereology techniques in radiation biology

Clinicians involved in conventional radiation therapy are very concerned about the dose-response relationships of normal tissues. Before proceeding to new clinical protocols, radiation biologists involved with conformal proton therapy believe it is necessary to quantify the dose response and tolerance of the organs and tissues that will be irradiated. An important focus is on the vasculature. This presentation reviews the methodology and format of using confocal microscopy and stereological methods to quantify tissue parameters, cell number, tissue volume and surface area, and vessel length using the microvasculature as a model tissue. Stereological methods and their concepts are illustrated using an ongoing study of the dose response of the microvessels in proton-irradiated hemibrain. Methods for estimating the volume of the brain and the brain cortex, the total number of endothelial cells in cortical microvessels, the length of cortical microvessels, and the total surface area of cortical microvessel walls are presented step by step in a way understandable for readers with little mathematical background. It is shown that stereological techniques, based on a sound theoretical basis, are powerful and reliable and have been used successfully.

Non-NASA Center↗

Proton Testing of AMD Ryzen 3 1200 Microprocessors

Single-Event Effects (SEE) testing was conducted on the AMD Ryzen 3 1200 microprocessor. Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

single event functional interrupt (SEFI)↗

Proton Testing of AMD Ryzen 3 2200G Microprocessors

Single-Event Effects (SEE) testing was conducted on the AMD Ryzen 3 2200G microprocessor with integrated graphics. Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

radiation tesing↗

Proton Testing of AMD e9173 GPU

Single-Event Effects (SEE) testing was conducted on the AMD e9173 Graphics Processor Unit (GPU). Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center.

Single-Event Effects (SEE)↗

Proton Testing of nVidia Jetson TX2

Single-Event Effects (SEE) testing was conducted on the nVidia Jetson TX2 System on Chip (SOC). Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

System on Chip (SOC)↗

Single-Event Effect Testing of the Vishay Si7414DN n-Type TrenchFET(Registered Trademark) Power MOSFET

This study was being undertaken to determine the single event effect susceptibility of the commercial Vishay 60-V TrenchFET power MOSFET. Heavy-ion testing was conducted at the Texas AM University Cyclotron Single Event Effects Test Facility (TAMU) and the Lawrence Berkeley National Laboratory BASE Cyclotron Facility (LBNL). In addition, initial 200-MeV proton testing was conducted at Massachusetts General Hospital (MGH) Francis H. Burr Proton Beam Therapy Center. Testing was performed to evaluate this device for single-event effects from lower-LET, lighter ions relevant to higher risk tolerant space missions.

proton testing↗

Directional Spherical Cherenkov Detector

A proposed radiation-detecting apparatus would provide information on the kinetic energies, directions, and electric charges of highly energetic incident subatomic particles. The apparatus was originally intended for use in measuring properties of cosmic rays in outer space, but could also be adapted to terrestrial uses -- for example, radiation dosimetry aboard high-altitude aircraft and in proton radiation therapy for treatment of tumors.

Wrbanek, John D.↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Cancer therapy↗

Team Update on North American Proton Facilities for Radiation Testing

In the wake of the closure of the Indiana University Cyclotron Facility (IUCF), this presentation provides an overview of the options for North American proton facilities. This includes those in use by the aerospace community as well as new additions from the cancer therapy regime. In addition, proton single event testing background is provided for understanding the criteria needed for these facilities for electronics testing.

Single event effects testing↗