Engineering PapersSearch

SEARCH · Engineering Papers

Results for “profilometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Three-dimensional stylus profilometry

The method of three-dimensional stylus profilometry is presented together with a computer-based system for transforming the surface topography of a specimen into an intensity image. Examples are given in which intensity images obtained by stylus profilometry are compared with scanning electron micrographs and two other representations of the stylus data. The comparisons are made for three types of surface irregularities: a discrete feature, a periodic profile surface, and a random profile surface. It is shown that stylus profilometry provides high vertical resolution for low sloped surfaces and thus can be useful in revealing features not easily detectable with other methods.

Teague, E. C.

Radial Profilometry

Radial profilometry is combination of optical and electronic techniques for measurement of inner surfaces of cylindrical or nearly cylindrical cavities. Profilometer inserted in pipe or other cavity to measure its shape optically. Illumination supplied through optical fiber, and image of inspected area of cavity transmitted through bundle of optical fibers. Applications include inspection of pipes, tubes, boreholes, and possibly measurements of contours in blood vessels or other internal organs.

Gilbert, J. A.

Measurements of erosion characteristics for metal and polymer surfaces using profilometry

The surfaces of many materials exposed in low earth orbit are modified due to interaction with atomic oxygen. Chemical changes and surface roughening effects can occur which alter optical and other properties. The experiment A0114 contained 128 solid surface samples, half of which were exposed on the front and half on the rear of Long Duration Exposure Facility. Each sample was subjected to many analyses, but only the methods and techniques are described which were used to measure the changes in roughness, erosion depths, and material growth using profilometry.

Christl, Ligia C.

Measurements of erosion characteristics for metal and polymer surfaces using profilometry

The surfaces of many materials exposed in low earth orbit are modified due to interaction with atomic oxygen. Chemical changes and surface roughening effects can occur which alter optical and other properties. The experiment A0114 contained 128 solid surface samples, half of which were exposed on the front and half on the rear of LDEF. Each sample has been subjected to many analyses, but only the methods and techniques used to measure the changes in roughness, erosion depths, and material growth using profilometry are described.

Christl, Ligia C.

The interaction of atomic oxygen with copper: An XPS, AES, XRD, optical transmission, and stylus profilometry study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed to study the reaction of material surfaces with low earth orbits (LEO) atmospheric oxygen. The experiment contained 128 one-inch circular samples; metals, polymers, carbons, and semiconductors. Half of these samples were exposed on the front of the Long Duration Exposure Facility (LDEF) and remaining on the rear. Among metal samples, copper has shown some interesting new results. There were two forms of copper samples: a thin film sputter-coated on fused silica and a solid piece of OFHC copper. They were characterized by x-ray and Auger electron spectroscopies, x-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to demonstrate the presence of Cu2O and CuO and to determine the oxidation states.

Raikar, Ganesh N.

On the use of laser profilometry for ocean wave studies

Airborne laser profilometer measurements of wave skewness and spectra are presented. The measurements were made during high wind and sea state conditions in the North Atlantic. The sea states ranged from 4.5 to 8.7 m and varied from swell to wind wave dominated situations. Skewness values for the five cases ranged from 0.08 to 0.28 and compare favorably with other existing measurements. Also, the Phillips and Wallops spectral models show excellent agreement with profilometer spectra of developing seas. For one case where the seas were fully developed, the Pierson-Moskowitz spectrum provides the best representation.

Mcclain, C. R.

Robust, sub-angstrom level mid-spatial frequency profilometry

A noncontacting measurement approach is presented that involves the measurement of the local curvature of the test piece by simultaneously measuring its slope at two slightly displaced locations. As the sensing beams are scanned along the test piece, a profile of curvature is built, from which the height profile is deduced by double integration. The sensing of curvature eliminates the need for a reference surface, and makes the approach insensitive to all types of vibration and drift, both in surface height and in surface slope. The approach is considered to be well suited to measuring grazing incidence optics with highly different transverse and longitudinal radii of curvature. Implementation features including a steering mirror and a movable detector provide for servo tracking of test pieces as fast as F-0.5, with radii as small as 20 mm (convex or concave).

Glenn, Paul

Robust, angstrom level circularity profilometry

A noncontacting approach is presented which involves measuring the local circumferential curvature of the test piece by simultaneously measuring its circumferential slope at two slightly displaced locations. A pair of sensing beams is scanned along the circumference, and a profile of curvature is built, from which the circularity profile is deduced. The sensing of curvature makes the approach insensitive to all types of vibration and drift and runout errors in the relative rotation. The special qualities of the approach are summarized which make it well suited to measuring cylindrical optics and enable it to accommodate radii as small as twenty millimeters.

Glenn, Paul

Angstrom level profilometry for sub-millimeter to meter scale surface errors

A versatile noncontacting profilimetry approach is defined which involves the measurement of the local curvature of a test piece by simultaneously measuring its slope at two slightly displaced locations. Several extensions of the measurement technique are emphasized including beam expansion for long scans, measurement of circularity and cone angle of near cylindrical optics, and measurement of absolute flatness.

Glenn, Paul

Precision Thickness Variation Mapping Via One-Transducer Ultrasonic High Resolution Profilometry for Sample With Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses is discussed. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.

Precision Thickness Variation Mapping via One-Transducer Ultrasonic High Resolution Profilometry for Sample with Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.

Discerning Cell Surface Defects with 3D Optical Profilometry

This investigation seeks to establish better criteria that can be used for qualitative visual screening of cylindrical battery cells through exploration of various defects across multiple cylindrical Lithium-Ion battery cells. This investigation focuses on INR18650s and INR21700s cells from Molicel, LG, and Samsung. The principal instrument used is a high-definition 3D optical profilometer with measurement accuracy less than 0.5 microns. Through this effort, a catalog was built discerning minor surface imperfections from significant flaws. The catalog generated covers a comparison of axial and radial scratches, less than 5 microns, greater than 5 microns and greater than 15 microns, as well as the difference between surface discoloration, early-stage pitting, and late stages of corrosion. An exploration is made into cell button defects and crimp shoulder defects. When ultra-high-power optical magnification and three-dimension topological tools are not immediately available, this catalog will help determine if an individual cell is usable, worth further investigation, or failing. The purpose of this catalog is to be a field guide used for quick reference of a potential issue, with the goal of increasing screening throughput while reducing the need for costly examination. Trade names and trademarks are used in this abstract for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration.

battery

Discerning Cell Surface Defects with 3D Optical Profilometry

This investigation seeks to establish better criteria that can be used for qualitative visual screening of cylindrical battery cells through exploration of various defects across multiple cylindrical Lithium-Ion battery cells. This investigation focuses on INR18650s and INR21700s cells from Molicel, LG, and Samsung. The principal instrument used is a high-definition 3D optical profilometer with measurement accuracy less than 0.5 microns. Through this effort, a catalog was built discerning minor surface imperfections from significant flaws. The catalog generated covers a comparison of axial and radial scratches, less than 5 microns, greater than 5 microns and greater than 15 microns, as well as the difference between surface discoloration, early-stage pitting, and late stages of corrosion. An exploration is made into cell button defects and crimp shoulder defects. When ultra-high-power optical magnification and three-dimension topological tools are not immediately available, this catalog will help determine if an individual cell is usable, worth further investigation, or failing. The purpose of this catalog is to be a field guide used for quick reference of a potential issue, with the goal of increasing screening throughput while reducing the need for costly examination. Trade names and trademarks are used in this abstract for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration.

battery

MAB Phase Ceramics for Lunar Applications

During the ten-week internship my work focused on designing characterization protocol for 3D printed MAB phase ceramics on steel and Tiplates. I was mentored by Dr. Samuel Hocker of NASA and advised by Dr. Gupta from University of North Dakota. I also collaborated with Mackenzie Short from the University of North Dakota. The characterization protocol was divided into following steps; initially, we performed visual inspection of the plates. During this process, the coatings which spalled or delaminated were discarded for further evaluation. During the next step, we performed optical microscopy to discern and document surface features and porosities of the samples. We also noted some decomposition under the optical microscope as well. Thereafter, profilometry analysis was performed to understand the effect of power density on the surface roughness. Due to the deposited powder over the samples, the profilometry was inconclusive. We then cleaned the samples on the steel plate using ethanol and cotton swabs to wipe up the loose powder covering the samples. Detailed SEM analysis was then performed on the cleaned specimens. In parallel, the 3D printed samples on the Tiplate were cleaned by using an ultrasonic bath for 1h. Optical imaging showed that this cleaning process was more effective for cleaning except that small cracks propagated through the layered ceramics. The profilometry data gathered on the titanium plate after cleaning was more conclusive. The SEM data on the steel plate showed that there is decomposition at all wattages although at 100 W the extent of decomposition was lower. We are planning to characterize the steel samples after cleaning in ultrasonic bath for 5-10 min to minimize cracking during the cleaning process. In addition, we are also planning to study the fractured surface by SEM analysis.

Additive Manufacturing, Laser Powder Bed Fusion, S

Analysis of surfaces from the LDEF A0114, phase 4

Progress made from 1 Mar. to 31 Aug. 1991 is presented. The work concentrated on profilometry measurements of eroded and corroded sample surfaces, optical transmission measurements, analysis of the pinhole camera, and x-ray photoelectron spectroscopic (XPS) analysis of some samples. The following papers are presented: (1) observation of Be-7 on the surface of the Long Duration Exposure Facility (LDEF) Spacecraft; (2) measurement of the passive attitude control performance of a recovered spacecraft; (3) effects on LDEF exposed copper flim and bulk; (4) measurements of erosion characteristics for metal and polymer surfaces using profilometry; (5) the interactions of atmospheric cosmogenic radionuclides with spacecraft surfaces; (6) pinhole cameras as sensors for atomic oxygen in orbit; and (7) interaction of atomic oxygen with solid surfaces in low earth orbit- results from LDEF experiment A0114.

Gregory, John C.

Interactions of atomic oxygen with material surfaces in low Earth orbit: Preliminary results from experiment A0114

The atomic oxygen experiment consisted of two trays (one-sixth of a Long Duration Exposure Facility (LDEF) tray each) of 64 one inch diameter solid samples. It was intended that the effects of atomic oxygen and solar ultraviolet irradiation on the surface properties of each material could be distinguished from each other and from the effects of aging. Sixteen of the samples were placed on a thermally isolated plate of highly polished aluminum, while the main plate was coated with the thermal control coating S13-GLO. Though the experiment was entirely passive, it was hoped that the effects of thermal activation might be observed, if present. The plates were expected to stabilize at temperatures differing by 20-30 C. The samples included thin films of metals Os, Ir, Pt, Ni, Mo, and Al coated onto silica optical flats, metal carbides (WC, SiC), solid carbons of various types, eight polymers, and some other coatings of various types. Analysis is essentially complete using stylus profilometry with high sensitivity Talystep and lower sensitivity Talysurf machines. Though the integrated fluence of O atoms on the LDEF was 30 times that of previous missions, etch depths of the polymers such as the polyimide Kapton show excellent agreement with extrapolations from previous flight data. However, some new effects were observed. We demonstrated on a previous experiment on STS-8 that profilometry of this kind can show steps of 50 A (for example those due to oxide film growth on metals) and this is now the preferred method for estimating etch depth (or mass loss) of erodible substances.

Gregory, John C.

Interaction of atomic oxygen with thin film and bulk copper: An XPS, AES, XRD, and profilometer study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed primarily to study degradation of material surfaces due to low earth orbital (LEO) atmospheric oxygen. The experiment contained 128 one inch circular samples: metals, polymers, carbons, and semiconductors. Among metal samples, copper has shown some interesting new results. Two types of copper samples, a film sputter coated on fused silica and a bulk piece of OFHC copper, were characterized employing a variety of techniques such as X-ray and Auger electron spectroscopies, X-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to characterize the presence of Cu2O and CuO in addition to Cu Auger LMM lines. These results are supported by our recent X-ray diffraction studies which clearly establish the presence of Cu oxides which we were unable to prove in our earlier work. Profilometry showed an increase in thickness of the film sample where exposed to 106.7 +/- 0.5 nm from an initial thickness of 74.2 +/- 1.1 nm. Further studies with SEM and ellipsometry are underway.

Raikar, Genesh N.

Analysis of surfaces from the LDEF A0114, phase 2

During the reporting period, work continued on profilometry measurements of eroded and corroded sample surfaces, optical transmission measurements, analysis of the pinhole camera, and x-ray photoelectron spectroscopy (XPS) analysis of some samples. Among metal samples, copper showed some interesting new results. There were two forms of copper samples: a thin film sputter-coated on fused silica and a solid piece of OFHC copper. They were characterized by x-ray and Auger electron spectroscopies, x-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to demonstrate the presence of Cu2O and CuO and to determine the oxidation states.

Gregory, John C.