Engineering PapersSearch

SEARCH · Engineering Papers

Results for “profilometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Three-dimensional stylus profilometry

The method of three-dimensional stylus profilometry is presented together with a computer-based system for transforming the surface topography of a specimen into an intensity image. Examples are given in which intensity images obtained by stylus profilometry are compared with scanning electron micrographs and two other representations of the stylus data. The comparisons are made for three types of surface irregularities: a discrete feature, a periodic profile surface, and a random profile surface. It is shown that stylus profilometry provides high vertical resolution for low sloped surfaces and thus can be useful in revealing features not easily detectable with other methods.

Teague, E. C.

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology

Measuring 3D Profilometry of SAVY-4000 Nuclear Material Storage Containers: Novacam TubeInspect Capabilities Report

The SAVY-4000 container series is a general-purpose interim storage container for nuclear materials, developed and maintained by Los Alamos National Laboratory (LANL). It is the first vented, general-use nuclear material container to be demonstrated as meeting the requirements outlined in DOE M 441.1-1, the Nuclear Material Packaging Manual. Due to the challenging radiation, thermal, and corrosive storage conditions that the SAVY containers must endure, continuous surveillance techniques are employed to ensure the containers meet all safety standards and specifications. These inspections are typically performed by human operators, who check for issues such as corrosion, O-ring deterioration, corrosion, filter integrity, and potential manufacturing defects. However, human inspections alone are not sufficient, and automated inspection technologies, such as the ATIS system, as well as other automated systems are also utilized. The MicroCam TubeInspect, developed by Novacam Technologies Inc., is designed to address the challenges of understanding how manufacturing variations in the SAVY-4000 container series may affect performance. It is a 3D profilometry measurement system that enables detailed analysis of surface features, including defects, surface roughness, and manufacturing variations. This advanced tool significantly enhances rapid surveillance techniques for both pristine and used containers. In this study, container properties such as surface roughness, thickness, and geometric attributes like circularity are measured for SAVY-4000 containers. Artificially corroded or dented containers are examined to demonstrate the MicroCam's ability to quantify defects. A sensitivity analysis is also conducted, comparing the MicroCam results to those obtained using more precise instruments such as confocal microscopy. This comparison aims to provide valuable insights into container quality, durability, and potential improvements in manufacturing processes.

42 ENGINEERING

Radial Profilometry

Radial profilometry is combination of optical and electronic techniques for measurement of inner surfaces of cylindrical or nearly cylindrical cavities. Profilometer inserted in pipe or other cavity to measure its shape optically. Illumination supplied through optical fiber, and image of inspected area of cavity transmitted through bundle of optical fibers. Applications include inspection of pipes, tubes, boreholes, and possibly measurements of contours in blood vessels or other internal organs.

Gilbert, J. A.

Measurements of erosion characteristics for metal and polymer surfaces using profilometry

The surfaces of many materials exposed in low earth orbit are modified due to interaction with atomic oxygen. Chemical changes and surface roughening effects can occur which alter optical and other properties. The experiment A0114 contained 128 solid surface samples, half of which were exposed on the front and half on the rear of Long Duration Exposure Facility. Each sample was subjected to many analyses, but only the methods and techniques are described which were used to measure the changes in roughness, erosion depths, and material growth using profilometry.

Christl, Ligia C.

Measurements of erosion characteristics for metal and polymer surfaces using profilometry

The surfaces of many materials exposed in low earth orbit are modified due to interaction with atomic oxygen. Chemical changes and surface roughening effects can occur which alter optical and other properties. The experiment A0114 contained 128 solid surface samples, half of which were exposed on the front and half on the rear of LDEF. Each sample has been subjected to many analyses, but only the methods and techniques used to measure the changes in roughness, erosion depths, and material growth using profilometry are described.

Christl, Ligia C.

The interaction of atomic oxygen with copper: An XPS, AES, XRD, optical transmission, and stylus profilometry study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed to study the reaction of material surfaces with low earth orbits (LEO) atmospheric oxygen. The experiment contained 128 one-inch circular samples; metals, polymers, carbons, and semiconductors. Half of these samples were exposed on the front of the Long Duration Exposure Facility (LDEF) and remaining on the rear. Among metal samples, copper has shown some interesting new results. There were two forms of copper samples: a thin film sputter-coated on fused silica and a solid piece of OFHC copper. They were characterized by x-ray and Auger electron spectroscopies, x-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to demonstrate the presence of Cu2O and CuO and to determine the oxidation states.

Raikar, Ganesh N.

Defining Probe Closure Offset and Scan Stitching Methodology for Element Contact Profilometry in the Hot Fuel Examination Facility

The Element Contact Profilometer (ECP) is a non-destructive post-irradiation examination (PIE) method established in the Materials and Fuels Complex (MFC) Hot Fuel Examination Facility (HFEF). The ECP suspends a fuel rod with a standard end-fitting in a vertical orientation and draws it between two opposed Sony probes with sapphire rod tips, which measure the diameter directly as a function of vertical stage position through contact profilometry. The ECP is equipped with concave rollers, which pinch the rod to maintain a consist position between these sapphire probe tips. A schematic of the analysis head is shown in Figure 1. The gripper that suspends the rod end-fitting is able to rotate to allow measuring of any azimuthal angle around the rod. This system is used to characterize the diameter of full-length light water reactor (LWR) irradiated fuel rods at multiple azimuthal angles in support of the Advanced Fuels Campaign (AFC).

22 - GENERAL STUDIES OF NUCLEAR REACTORS

On the use of laser profilometry for ocean wave studies

Airborne laser profilometer measurements of wave skewness and spectra are presented. The measurements were made during high wind and sea state conditions in the North Atlantic. The sea states ranged from 4.5 to 8.7 m and varied from swell to wind wave dominated situations. Skewness values for the five cases ranged from 0.08 to 0.28 and compare favorably with other existing measurements. Also, the Phillips and Wallops spectral models show excellent agreement with profilometer spectra of developing seas. For one case where the seas were fully developed, the Pierson-Moskowitz spectrum provides the best representation.

Mcclain, C. R.

Robust, sub-angstrom level mid-spatial frequency profilometry

A noncontacting measurement approach is presented that involves the measurement of the local curvature of the test piece by simultaneously measuring its slope at two slightly displaced locations. As the sensing beams are scanned along the test piece, a profile of curvature is built, from which the height profile is deduced by double integration. The sensing of curvature eliminates the need for a reference surface, and makes the approach insensitive to all types of vibration and drift, both in surface height and in surface slope. The approach is considered to be well suited to measuring grazing incidence optics with highly different transverse and longitudinal radii of curvature. Implementation features including a steering mirror and a movable detector provide for servo tracking of test pieces as fast as F-0.5, with radii as small as 20 mm (convex or concave).

Glenn, Paul

Robust, angstrom level circularity profilometry

A noncontacting approach is presented which involves measuring the local circumferential curvature of the test piece by simultaneously measuring its circumferential slope at two slightly displaced locations. A pair of sensing beams is scanned along the circumference, and a profile of curvature is built, from which the circularity profile is deduced. The sensing of curvature makes the approach insensitive to all types of vibration and drift and runout errors in the relative rotation. The special qualities of the approach are summarized which make it well suited to measuring cylindrical optics and enable it to accommodate radii as small as twenty millimeters.

Glenn, Paul

Angstrom level profilometry for sub-millimeter to meter scale surface errors

A versatile noncontacting profilimetry approach is defined which involves the measurement of the local curvature of a test piece by simultaneously measuring its slope at two slightly displaced locations. Several extensions of the measurement technique are emphasized including beam expansion for long scans, measurement of circularity and cone angle of near cylindrical optics, and measurement of absolute flatness.

Glenn, Paul

Precision Thickness Variation Mapping Via One-Transducer Ultrasonic High Resolution Profilometry for Sample With Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses is discussed. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.

Precision Thickness Variation Mapping via One-Transducer Ultrasonic High Resolution Profilometry for Sample with Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.

Progress Report on SFR Metallic Fuel Data Qualification

This report summarizes the progress of SFR metallic fuel qualification related activities, which are focused on providing quality assurance relevant information applicable to experiments irradiated during the Integral Fast Reactor (IFR) program. An overview of the metallic fuel performance data and the associated databases, including the EBR-II Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT Experimental Relational Database (TREXR) is included. The legacy data in the databases, including as-built, post-irradiation examination (PIE), operating parameters, and out-of-pile experiment post-test data are introduced. The SFR metallic fuel Quality Assurance Program Plan (QAPP) and its implementation to qualify these legacy data is described in detail. Important PIE data QA documents and the specifications of seven types of PIE measurements (contact profilometry, laser profilometry, neutron radiography, gamma scan, fission gas release fission gas chemistry, and metallography) are provided. Examples of the implementation of the QAPP to qualify each of those types of PIE data are provided.

Mo, Kun [Argonne National Laboratory (ANL), Argonn

Quality Assurance of Legacy Post-Irradiation Examination Data for Metallic Fuels

The U.S. DOE-NE’s Advanced Reactor Technologies (ART) Fast Reactor Program (FRP) and the NE-4 Advanced Fuels Campaign (AFC) have jointly undertaken the qualification of the legacy post-irradiation examination (PIE) data held in the Fuels Irradiation & Physics Database (FIPD), covering metallic fuel experiments conducted in the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF). In FY26 this effort reached a milestone: six major types of PIE data—contact profilometry, isotopic gamma scan, fission gas chemistry, fission gas release, laser profilometry, and neutron radiography—have been qualified for all available experiments in FIPD, and the U.S. nuclear industry can now draw on them with confidence in licensing activities for metallic fuel-based advanced fast reactors. This report documents the qualification process and the resulting status of the PIE data.

Mo, Kun

Analysis of surfaces from the LDEF A0114, phase 4

Progress made from 1 Mar. to 31 Aug. 1991 is presented. The work concentrated on profilometry measurements of eroded and corroded sample surfaces, optical transmission measurements, analysis of the pinhole camera, and x-ray photoelectron spectroscopic (XPS) analysis of some samples. The following papers are presented: (1) observation of Be-7 on the surface of the Long Duration Exposure Facility (LDEF) Spacecraft; (2) measurement of the passive attitude control performance of a recovered spacecraft; (3) effects on LDEF exposed copper flim and bulk; (4) measurements of erosion characteristics for metal and polymer surfaces using profilometry; (5) the interactions of atmospheric cosmogenic radionuclides with spacecraft surfaces; (6) pinhole cameras as sensors for atomic oxygen in orbit; and (7) interaction of atomic oxygen with solid surfaces in low earth orbit- results from LDEF experiment A0114.

Gregory, John C.

Interactions of atomic oxygen with material surfaces in low Earth orbit: Preliminary results from experiment A0114

The atomic oxygen experiment consisted of two trays (one-sixth of a Long Duration Exposure Facility (LDEF) tray each) of 64 one inch diameter solid samples. It was intended that the effects of atomic oxygen and solar ultraviolet irradiation on the surface properties of each material could be distinguished from each other and from the effects of aging. Sixteen of the samples were placed on a thermally isolated plate of highly polished aluminum, while the main plate was coated with the thermal control coating S13-GLO. Though the experiment was entirely passive, it was hoped that the effects of thermal activation might be observed, if present. The plates were expected to stabilize at temperatures differing by 20-30 C. The samples included thin films of metals Os, Ir, Pt, Ni, Mo, and Al coated onto silica optical flats, metal carbides (WC, SiC), solid carbons of various types, eight polymers, and some other coatings of various types. Analysis is essentially complete using stylus profilometry with high sensitivity Talystep and lower sensitivity Talysurf machines. Though the integrated fluence of O atoms on the LDEF was 30 times that of previous missions, etch depths of the polymers such as the polyimide Kapton show excellent agreement with extrapolations from previous flight data. However, some new effects were observed. We demonstrated on a previous experiment on STS-8 that profilometry of this kind can show steps of 50 A (for example those due to oxide film growth on metals) and this is now the preferred method for estimating etch depth (or mass loss) of erodible substances.

Gregory, John C.