Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “proficiency test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report: Document # 6679664_11752120)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 5/19/2020, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

47 OTHER INSTRUMENTATION↗

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report; PT ID Number 6679665)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 12/28/2021, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

42 ENGINEERING↗

GenomeTrakr proficiency testing for foodborne pathogen surveillance: an exercise from 2015

Pathogen monitoring is becoming more precise as sequencing technologies become more affordable and accessible worldwide. This transition is especially apparent in the field of food safety, which has demonstrated how whole-genome sequencing (WGS) can be used on a global scale to protect public health. GenomeTrakr coordinates the WGS performed by public-health agencies and other partners by providing a public database with real-time cluster analysis for foodborne pathogen surveillance. Because WGS is being used to support enforcement decisions, it is essential to have confidence in the quality of the data being used and the downstream data analyses that guide these decisions. Routine proficiency tests, such as the one described here, have an important role in ensuring the validity of both data and procedures. In 2015, the GenomeTrakr proficiency test distributed eight isolates of common foodborne pathogens to participating laboratories, who were required to follow a specific protocol for performing WGS. Resulting sequence data were evaluated for several metrics, including proper labelling, sequence quality and new single nucleotide polymorphisms (SNPs). Illumina MiSeq sequence data collected for the same set of strains across 21 different laboratories exhibited high reproducibility, while revealing a narrow range of technical and biological variance. The numbers of SNPs reported for sequencing runs of the same isolates across multiple laboratories support the robustness of our cluster analysis pipeline in that each individual isolate cultured and resequenced multiple times in multiple places are all easily identifiable as originating from the same source.

59 BASIC BIOLOGICAL SCIENCES↗

Application of trichloroacetimidate-mediated benzylation to the detection of pinacolyl methylphosphonic acid in standardised proficiency test matrices

Here, a procedure for the qualitative analysis of pinacolyl methylphosphonic acid (PMPA), a degradation product from the nerve agent Soman (GD), is presented. The protocol involves the derivatization of PMPA with benzyl trichloroacetimidate resulting in its benzylation under neutral conditions, a desirable attribute in the presence of other base-sensitive analytes. The method was found to perform well in the detection of this Schedule 2 chemical, spiked at low concentrations, in three different test matrices, two soils and one liquid, featured in different Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests.

Chemistry↗

Benzyl trichloroacetimidates as derivatizing agents for phosphonic acids related to nerve agents by EI-GC-MS during OPCW proficiency test scenarios

Abstract The use of benzyl trichloroacetimidates for the benzylation of phosphonic acid nerve agent markers under neutral, basic, and slightly acidic conditions is presented. The benzyl-derived phosphonic acids were detected and analyzed by Electron Ionization Gas Chromatography–Mass Spectrometry (EI-GC–MS). The phosphonic acids used in this work included ethyl-, cyclohexyl- and pinacolyl methylphosphonic acid, first pass hydrolysis products from the nerve agents ethyl N -2-diisopropylaminoethyl methylphosphonothiolate (VX), cyclosarin (GF) and soman (GD) respectively. Optimization of reaction parameters for the benzylation included reaction time and solvent, temperature and the effect of the absence or presence of catalytic acid. The optimized conditions for the derivatization of the phosphonic acids specifically for their benzylation, included neutral as well as catalytic acid (< 5 mol%) and benzyl 2,2,2-trichloroacetimidate in excess coupled to heating the mixture to 60 °C in acetonitrile for 4 h. While the neutral conditions for the method proved to be efficient for the preparation of the p -methoxybenzyl esters of the phosphonic acids, the acid-catalyzed process appeared to provide much lower yields of the products relative to its benzyl counterpart. The method’s efficiency was tested in the successful derivatization and identification of pinacolyl methylphosphonic acid (PMPA) as its benzyl ester when present at a concentration of ~ 5 μg/g in a soil matrix featured in the Organisation for the Prohibition of Chemical Weapons (OPCW) 44th proficiency test (PT). Additionally, the protocol was used in the detection and identification of PMPA when spiked at ~ 10 μg/mL concentration in a fatty acid-rich liquid matrix featured during the 38 th OPCW-PT. The benzyl derivative of PMPA was partially corroborated with the instrument's internal NIST spectral library and the OPCW central analytical database (OCAD v.21_2019) but unambiguously identified through comparison with a synthesized authentic standard. The method’s MDL (LOD) values for the benzyl and the p -methoxybenzyl pinacolyl methylphosphonic acids were determined to be 35 and 63 ng/mL respectively, while the method’s Limit of Quantitation (LOQ) was determined to be 104 and 189 ng/mL respectively in the OPCW-PT soil matrix evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of carbonyldiimidazole as a derivatization agent for the detection of pinacolyl alcohol, a forensic marker for Soman, by EI-GC–MS and LC-HRMS in official OPCW proficiency test matrices

Pinacolyl alcohol (PA), a key forensic marker for the nerve agent Soman (GD), is a particularly difficult analyte to detect by various analytical methods. In this work, we have explored the reaction between PA and 1,1'-carbonyldiimidazole (CDI) to yield pinacolyl 1H-imidazole-1-carboxylate (PIC), a product that can be conveniently detected by gas chromatography–mass spectrometry (GC–MS) and liquid chromatography-high-resolution mass spectrometry (LC-HRMS). Regarding its GC–MS profile, this new carbamate derivative of PA possesses favorable chromatographic features such as a sharp peak and a longer retention time (RT = 16.62 min) relative to PA (broad peak and short retention time, RT = 4.1 min). Additionally, the derivative can also be detected by LC-HRMS, providing an avenue for the analysis of this chemical using this technique where PA is virtually undetectable unless present in large concentrations. From a forensic science standpoint, detection of this low molecular weight alcohol signals the past or latent presence of the nerve agent Soman (GD) in a given matrix (i.e., environmental or biological). The efficiency of the protocol was tested separately in the analysis and detection of PA by EI-GC–MS and LC-HRMS when present at a 10 μg/mL in a soil matrix featured in the 44th PT and in a glycerol-rich liquid matrix featured in the 48th Official Organization for the Prohibition of Chemical Weapons (OPCW) Proficiency Test when present at a 5 μg/mL concentration. In both scenarios, PA was successfully transformed into PIC, establishing the protocol as an additional tool for the analysis of this unnatural and unique nerve agent marker by GC–MS and LC-HRMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highlighting the Importance of Authentic Reference Chemicals in the Unambiguous Identification of Unknowns during Routine Sample Analysis─An OPCW Proficiency Test Case

The unequivocal identification of unknown chemicals during routine sample analysis is a constant occurrence in the field of analytical chemistry. The process can be painstakingly tedious, particularly in situations where a tentatively identified unknown may possess isomeric counterparts yielding identical accurate mass values and very similar mass spectra. In this work, we present the experimental process involved in the correct identification of 1,4-oxathiane 4,4-dioxide and differentiation from its constitutional isomer, 2-hydroxyethyl vinyl sulfone, when present in a silica gel matrix featured in the 54th Environmental Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test. After discovering that the library-generated mass spectrum for 2-hydroxyethyl vinyl sulfone in a preliminary gas chromatography–mass spectrometry (GC-MS) analysis did not match the one from an authentic reference chemical, we embarked on an unknown structure determination campaign involving GC-MS, liquid chromatography-tandem mass spectrometry (LC-MS-MS), and nuclear magnetic resonance (NMR) spectroscopy. All of the information obtained, coupled to the synthesis of an authentic reference chemical, was used to determine the identity of the unknown as 1,4-oxathiane 4,4-dioxide. The process described in this work highlights the important role played by authentic reference chemicals in the identification of unknown chemicals during routine sample analysis.

Chemistry↗

Acylation as a successful derivatization strategy for the analysis of pinacolyl alcohol in a glycerol-rich matrix by GC-MS: application during an OPCW Proficiency Test

A derivatization protocol based on the acylation of pinacolyl alcohol (PA), an important marker for the nerve agent soman, is presented. The procedure provides a convenient means of detecting, by gas chromatography-mass spectrometry (GC-MS), PA when present at a low concentration in a complex glycerol/alcohol-rich matrix. While there are only two reports describing the specific analysis of PA in matrices at low concentrations, the protocol described herein represents the first of its kind in the analysis of PA in a highly reactive matrix. Two alternative paths for the protocol’s execution are presented. The first involves the direct derivatization of the PA with either acetyl or benzoyl chloride; both reactions yield ester products with significantly different retention times than those of the interferences of the reactive glycerol-rich matrix and in areas of the GC-chromatogram featuring lower levels of matrix interferences. A second procedure involved an initial diethyl ether/aqueous extraction of the matrix; while the extraction was found to substantially remove many of the hydrophilic matrix components and improve the overall derivatization, it also led to some loss of PA available for the derivatization. Both protocols were applied to the successful derivatization and analysis of PA by GC-MS when present at a 5 μg.mL -1 concentration in a glycerol-rich matrix sample administered during the 48th Proficiency Test administered by the Organisation for the Prohibition of Chemical Weapons (OPCW).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing the reliability of the NIST library during routine GC-MS analyses: Structure and spectral data corroboration for 5,5-diphenyl-1,3-dioxolan-4-one during a recent OPCW proficiency test

In the field of analytical chemistry, it is the nature of the available instrumentation that makes a specific technique uniquely suited for answering a specific challenge. Often times, instruments equipped with ultrasensitive array of detectors and state-of-the-art separation components have served to highlight their invaluable role in the field. Nonetheless, it is their ultimate ability to predict the structure of an unknown material on the basis of mass spectral data that exponentially magnifies their value. Their efficacy in achieving this prediction is largely based on the size of their internal mass spectral library that conveniently can be accessed by using the software. The library can thus exhaustively correlate an unknown compound's mass spectrum to known compounds in a database and provide the analytical chemist with a probable structure for the unknown analyte. During routine analysis, it is customary that after the appropriate collection of the compound's mass spectrum, the next step involves its comparison with a compound in the instrument's National Institute of Standards and Technology (NIST) library.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LLNL Evaluation of 44th OPCW Environmental Proficiency Test

The goal of the test was to analyze all samples for the presence of any Scheduled Chemicals and/or their precursors/degradation/reaction products and chemicals listed in the list of “Additional Non-Scheduled Reportable Chemicals”. According to the test scenario, the samples were collected from a facility described as an industrial research laboratory for developing new chemical compounds. Each participating laboratory received a set of three aqueous samples (described as “Decon Waste”) and a set of three soil samples (described as collected in an area of suspected chemical contamination, near a chemical storage facility). Each set of samples contained one “test sample”, one “control sample”, and one “blank sample” without indication of their identities. The test sample contained an unknown number of spiking chemicals, each present at a concentration of 1 ppm or greater. The control sample contained an unknown number of spiking chemicals, each present at a concentration of 5 ppm or greater. The blank sample contained no chemicals relevant to the aim of the test. However, for this test, the blank samples did contain irrelevant chemicals in addition to the sample matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experiments regarding methylphosphonic acid in proficiency test Sample 445

Samples 445/07 and 444/07 (blank) were extracted, in triplicate, by three different extraction methods – column elution, gentle rocking, and agitation with a vortex mixer. The recoveries for MPA differed depending on the extraction method used. In Sample 445/07, MPA was measured at ~2 μg/g (~20% recovery) when extracted by column elution and at ~1 μg/g when gentle rocking or vortex mixing was used. In addition, the soil matrix was observed to cause some ionization suppression effects when LC/MS analysis was used. The results of our experiments support the findings of the Sample Preparation Laboratory and suggest that MPA should remain a scoring chemical for the 44th OPCW PT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical analysis of an inter-laboratory comparison of small-scale safety and thermal testing of RDX

In this study, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency test for small-scale safety and thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results from this test for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Class 5 Type II standard. The material was tested as a well-characterized standard several times during the proficiency test to assess differences among participants and the range of results that may arise for well-behaved explosive materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OPCW Twining Project Visit by the National Laboratory of Scientific and Technical Police (LNPST) to Lawrence Livermore National Laboratory Forensic Science Center (LLNL)

PURPOSE FOR TRIP Through the Organisation for Prohibition of Chemical Weapons (OPCW) Twinning and Assistance Program, Lawrence Livermore National Laboratory, Forensic Science Center (LLNL) has been paired with Morocco’s National Laboratory of Scientific and Technical Police (LNPST), with the goal of mentoring LNPST to become an OPCW Designated Laboratory. The purpose of this visit was for LLNL staff to mentor staff from LNPST as they participated in hands-on, laboratory-based exercises to analyze proficiency test samples prepared by LLNL. This visit was designed to help LNPST scientists strengthen their skills in OPCW proficiency testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an unacceptable level of bias.

benchmark problems↗

Effective methylation of phosphonic acids related to chemical warfare agents mediated by trimethyloxonium tetrafluoroborate for their qualitative detection and identification by gas chromatography-mass spectrometry

The effective methylation of phosphonic acids related to chemical warfare agents (CWAs) employing trimethyloxonium tetrafluoroborate (TMO·BF 4 ) for their qualitative detection and identification by gas chromatography-mass spectrometry (GC-MS) is presented. The methylation occurs in rapid fashion (1 h) and can be conveniently carried out at ambient temperature, thus providing a safer alternative to the universally employed diazomethane-based methylation protocols. Optimization of the methylation parameters led us to conclude that methylene chloride was the ideal solvent to carry out the derivatization, and that even though methylated products can be observed surfacing after only 1 h, additional time was not found to be detrimental but beneficial to the process particularly when dealing with analytes at low concentrations (~10 μg mL -1 ). Due to its insolubility in methylene chloride, TMO·BF 4 conveniently settles to the bottom during the reaction and does not produce additional interfering by-products that may further complicate the GC-MS analysis. We demonstrated the method to successfully methylate a variety of Schedule 2 phosphonic acids, including their half esters, resulting in derivatives that were readily detected and identified using the instrument's spectral library. Most importantly, the method was shown to simultaneously methylate a mixture of the organophosphorus-based nerve agent hydrolysis products: pinacolyl methylphosphonate (PMPA), cyclohexyl methylphosphonate (CyMPA) and ethyl methylphosphonate (EMPA) (at a 10 μg mL - 1 concentration each) in a fatty acid ester-rich organic matrix (OPCW-PT-O 3 ) featured in the 38th Organisation for the Prohibition of Chemical Weapons (OPCW) Proficiency Test. Additionally, the protocol was found to effectively methylate N,N-diethylamino ethanesulfonic acid and N,N-diisopropylamino ethanesulfonic acid that are products arising from the oxidative degradation of the V-series agents VR and VX respectively. This work described herein represents the first report on the use of TMO·BF 4 as a viable, stable and safe agent for the methylation of phosphonic acids and their half esters and within the context of an OPCW Proficiency Test sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗