Engineering PapersSearch

SEARCH · Engineering Papers

Results for “procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Rancor Integrated Procedure System (RIPS): A Computer-Based Procedure Platform for Advanced Reactor Research

The Rancor Microworld Simulator is a simplified, pressurized water, small modular reactor simulator that includes a multi-unit plant model server, an advanced digital human-machine control interface, and the Rancor Integrated Procedure System (RIPS). Rancor provides a research and development tool that can be used for collecting operator performance data and for prototyping concepts of operations (ConOps) for advanced reactor development. RIPS is meant as a research tool and includes many unique features: (1) RIPS has a robust procedure authoring system. (2) RIPS has the capability to run any of the three IEEE-Std-1786 computer-based procedure types. (3) RIPS can be configured to take on the look and feel of different vendors’ computer-based procedure systems for the purpose of developing and evaluating different ConOps for plant upgrades or new builds. (4) RIPS includes the capability for logging operator procedure use, including integrating procedure logs with Rancor simulator logs, thereby allowing automated data collection of operator scenario runs. (5) RIPS integrates with the Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER), a dynamic human reliability analysis environment that creates a digital human twin or virtual operator to mimic reactor operator performance. (6) RIPS includes support for automation of plant monitoring and control functions. While RIPS is explicitly built into Rancor, it may also be used with full-scope training simulators. This functionality allows RIPS to be used for existing plants and advanced reactors under development.

99 - GENERAL AND MISCELLANEOUS

SIMS Data Correction Procedure for Quasi‐Simultaneous Arrival ( QSA ) Under‐counting and Ramifications of Misapplication

Isotope geochemistry requires isotope ratios measured using secondary ion mass spectrometry (SIMS) to be made with optimal precision and accuracy. Under some analytical conditions when using electron multiplier detectors, secondary ions may be under‐counted because of quasi‐simultaneous arrival (QSA) at the first dynode. The relative magnitude of the associated QSA correction to raw measured isotopic ratios can be up to seventy permil or more. Therefore, not applying the correction, or misapplication of it could lead to significant inaccuracies in published isotope ratio data. Examples and ramifications of the latter are described in addition to a straightforward procedure for QSA under‐counting correction.

Geochemistry & Geophysics

New procedure for evaluation of U(3) coupling and recoupling coefficients

A simple method to calculate Wigner coupling coefficients and Racah recoupling coefficients for U(3) in two group–subgroup chains is presented. While the canonical U(3) coupling and recoupling coefficients are applicable to any system that respects U(3) symmetry, the U(3) coupling coefficients are more specific to nuclear structure studies. This new procedure precludes the use of binomial coefficients and alternating sums which were used in the 1973 formulation of Draayer and Akiyama, and in so doing provides a faster and more accurate determination of any and all required results. The resolution of the outer multiplicity is based on the null space concept of the U(3) generators proposed by Alex et al., whereas the inner multiplicity in the angular momentum subgroup chain is obtained from the dimension of the null space of the SO(3) raising operator. It is anticipated that a C++ library will ultimately be available for determining generic coupling and recoupling coefficients associated with both the canonical and the physical group–subgroup chains of U(3).

Cross-Coupling Reaction

Data for Greenhouse Gas Accounting Procedures in Low Carbon Fuel Policies Overlook the Spatial Variability of Miscanthus-Derived Sustainable Aviation Fuel

Low carbon fuel policies such as the U.S. Renewable Fuel Standard (RFS), Canada Clean Fuel Regulations (CFR), and California Low Carbon Fuel Standard (LCFS) as well as the 45Z tax credit are intended to reduce greenhouse gas (GHG) emissions from transportation. Cellulosic feedstocks, optimized biorefineries, and favorable farming locations can significantly reduce biofuel carbon intensity (CI). Despite advances in field-to-fuel GHG monitoring and flexibility in resource allocation within biorefineries (e.g., governing net electricity production), rigid CI accounting procedures in current policies may limit CI responsiveness across candidate sites and processing facilities. This work examines a hypothetical biomass-to-sustainable aviation fuel (SAF) pathway using miscanthus and alcohol-to-jet (i) to demonstrate how GHG accounting requirements drive estimates of biofuel CIs and (ii) to explore potential CI and financial implications of scenario-specific life cycle assessment (LCA). Results demonstrate that GHG accounting using the CFR/LCFS can reasonably account for distinct levels of net electricity production by a biorefinery, but only the CFR yields similar CI sensitivity to spatially explicit factors (feedstock CI, grid electricity CI) as scenario-specific LCA: most GHG accounting frameworks do not capture CI variation across candidate sites in the United States. Ultimately, this work demonstrates the importance of LCA methodological specifications in low carbon fuel policies and tax credits.

Miscanthus

Civil Procedure for the Anthropocene

Climate considerations must become an element of procedural analysis. Scholars, rule makers, legislators, and judges have historically prioritized procedural values including cost, speed, and accuracy. More recent waves of scholarship—including critical perspectives—have emphasized participation as a further procedural goal. Yet this list has grown stale. Current environmental realities force all areas of law, including civil procedure, to reckon with climate change. In the future, proceduralists will be forced to integrate climate-aware thinking into their analyses, proposals, and discussions. Predictably, minds will disagree on how to accomplish this and the kinds of trade-offs that are warranted. Yet the fundamental point of this article remains: climate change resilience is a procedural concern that has not been recognized but must be. This signals not the genesis of a new branch of procedural scholarship but an opportunity to broaden the discussion for all procedural scholarship. In addition, this Article serves as a guide for rule makers and legislators who have just recently begun to show interest in climate-aware procedures. It directs them to procedural topics that require urgent attention, provides implementation strategies for developing resilient procedures, and considers the attendant costs and benefits of different approaches ranging from laissez-faire to aggressive engagement. Just as civil procedural innovations contributed to the emergence and success of the civil rights movement, our collective response to climate change will also be shaped by civil procedure. This Article prepares for this future and offers a corrective to the field’s failure to anticipate and respond to climate change.

54 ENVIRONMENTAL SCIENCES

Computer-Based Procedures Among Older Adults: Findings from the Rancor Microworld Simulator

As with many industries worldwide, nuclear energy is experiencing an aging workforce; older than other energy sources and the national average. For example, while almost one in three nuclear industry professionals are 55+ years, for oil and gas that number is one in five. The challenges brought about by an aging workforce are one of the industry’s top concerns. However, the industry lacks for empirical research that examines the effects of developmental aging in older workers, as well as the interactions between aging and new digital technologies. We present the results of an experiment that tested three different computer-based procedures in a sample of 30 older adults (55+ years). While the industry has traditionally relied on paper-based procedures, these are being modernized by digital technology. Participants were randomly assigned to one of three procedure-types that varied by the level of digitalization, based on the IEEE Standard-1786. Type 1 essentially represents a digital representation of a paper-based procedure, Type 2 adds embedded indicators, and Type 3 adds soft controls. Participants performed two different operational scenarios (startup and loss of feedwater) on a simplified nuclear power plant simulator. Results revealed a weak signal that Type 2 may produce lower workload and lower completion times in some instances. However, there were no significant effects of procedure-type across any other outcomes, including simulator log data, situation awareness, and preference ratings. We discuss our findings in terms of optimal levels of digitalization/automation for an aging nuclear workforce and suggest pathways for future directions.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

An efficient second-order adaptive procedure for inserting CAD geometries into hexahedral meshes using volume fractions

Here, this paper is concerned with inserting three-dimensional computer-aided design (CAD) geometries into meshes composed of hexahedral elements using a volume fraction representation. An adaptive procedure for doing so is presented. The procedure consists of two steps. The first step performs spatial acceleration using a k-d tree. The second step involves subdividing individual hexahedra in an adaptive mesh refinement (AMR)-like fashion and approximating the CAD geometry linearly (as a plane) at the finest subdivision. The procedure requires only two geometric queries from a CAD kernel: determining whether or not a queried spatial coordinate is inside or outside the CAD geometry and determining the closest point on the CAD geometry’s surface from a given spatial coordinate. We prove that the procedure is second-order accurate for sufficiently smooth geometries and sufficiently refined background meshes. We demonstrate the expected order of accuracy is achieved with several verification tests and illustrate the procedure’s effectiveness for several exemplar CAD geometries.

Adaptive

Light Water Reactor Sustainability Program: Use of Time Distributions to Predict Operator Procedure Performance in Dynamic Human Reliability Analysis

The Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) framework affords software capable of conducting human reliability analysis (HRA) using a dynamic approach built around operating procedures (OPs) from nuclear power plants (NPPs). Previous HUNTER reports document the development of this software tool, the coupling of HUNTER to the simulator code, the collection of operator performance data by using simulators to calibrate HUNTER models, and linking HUNTER to probabilistic risk assessment (PRA) software. The present report largely addresses two topics. The first is a new function in HUNTER called the HUNTER Procedure Performance Predictor (P3). HUNTER P3 uses HUNTER’s built in Monte Carlo tools featuring human performance variability to identify potential error traps in procedures. The second topic is time distribution analysis to generate time inputs for dynamic HRA. The current analysis was performed to investigate time distributions for task primitives, which are the minimum task unit of analysis used in dynamic HRA modeling. Using the time distribution data, the elapsed time for human actions in an extended loss of AC power (ELAP) scenario is then investigated. Time data and prediction are essential for modeling procedure performance.

99 GENERAL AND MISCELLANEOUS

SCALE Procedure for Verified, Archived, Library of Inputs and Data (VALID)

This procedure provides a framework for preparing, reviewing, and storing model inputs and derived data so that individuals with authorized access to the Verified, Archived, Library of Inputs and Data (VALID) repository can use the inputs and data with confidence in their analyses. This procedure uses documented checks and reviews to ensure that the inputs and data were correctly generated using appropriate references. Configuration management is implemented to prevent inadvertent modification of the inputs and data or inclusion of models that have not been reviewed. This procedure also provides guidance to be followed if errors are identified or if input or data revisions are needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

A Weakly Supervised Machine Learning Procedure for Magnet Quench Diagnostics

Voltage taps remain the standard and reliable diagnostic tool for detecting quenches in superconducting magnets. However, they identify a quench only at the time of voltage rise and do not provide information on earlier physical precursors. In this work, we investigate whether acoustic emission data can reveal precursor activity that occurs before conventional voltage detection using machine learning techniques. We introduce an event selection method and a weakly supervised machine learning procedure to learn data-driven criteria for identifying potential acoustic precursors to quenches. Two Convolutional Neural Network (CNN) architectures are trained: one on acoustic sensor events from our selection procedure and one on the Fast Fourier Transforms (FFTs) of these events. Both networks are trained iteratively using confidence-weighted loss functions to associate certain subsets of training data with a precursor label. We evaluate the performance of these models by examining the time distribution of events classified as potential precursors relative to the quench onset. Results indicate that the proposed approach can possibly distinguish acoustic emission events occurring closer to the quench from earlier acoustic activity during ramping, suggesting the potential for flagging quench precursors in acoustic data.

Khan, Maira [Fermilab] (ORCID:0009000891602387)

April 2024 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility (SWPF) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00027, Revision 0, one SDF waste form (saltstone) sample was prepared in the Savannah River National Laboratory (SRNL) from the SWPF Decontaminated Salt Solution (DSS) Waste Acceptance Criteria (WAC) sample and Z-area premix material for the April 2024 semiannual Toxicity Characteristic Leaching Procedure (TCLP) sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). After at least 28 days cured, a sample of the SDF waste form was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The April 2024 semiannual Cement-Free grout sample met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

October 2024 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility (SWPF) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00027, Revision 0, one SDF waste form (saltstone) sample was prepared in the Savannah River National Laboratory (SRNL) from the SWPF Decontaminated Salt Solution (DSS) Waste Acceptance Criteria (WAC) sample and Z-area premix material for the October 2024 semiannual Toxicity Characteristic Leaching Procedure (TCLP) sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). At 64 days cured, a sample of the SDF waste form was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The October 2024 semiannual Cement-Free grout sample met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and met the SPF WAC that was in effect at the time of the sample collection at SWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

DC Fast Charging Test Procedures

This report has been drafted as an initial effort to develop a standardized test procedure for DCFC for LD EVs. The proposed test procedures are designed to be time-efficient, aligned with EV discharge tests, and practical to implement, thereby minimizing the testing and computational efforts required by OEMs and testing authorities.

33 ADVANCED PROPULSION SYSTEMS

April 2025 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility is sampled semiannually for transfers to the Saltstone Production Facility. Salt solution is treated at the Saltstone Production Facility and disposed of in the Saltstone Disposal Facility. Per request of customer, X-TTR-Z-00027, Revision 0, one Saltstone Disposal Facility waste form was prepared at Savannah River National Laboratory using the Salt Waste Processing Facility Decontaminated Salt Solution and Z-area premix material for the April 2025 semiannual Toxicity Characteristic Leaching Procedure sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request prepared by Savannah River Mission Completion. At 43 days cured, the Saltstone sample was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure. The April 2025 semiannual Cement-Free grout sample met the South Carolina Code of Regulations for Hazardous Waste Management Regulations 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act metals and Underlying Hazardous Constituents, and met the Saltstone Production Facility Waste Acceptance Criteria that was in effect at the time of the sample collection at the Salt Waste Processing Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

October 2025 Semiannual Composite Salt Waste Processing Facility Decontaminated Salt Solution Toxicity Characteristic Leaching Procedure Results

The aqueous waste from the Salt Waste Processing Facility is sampled semiannually for transfers to the Saltstone Disposal Facility. Salt solution is treated at the Saltstone Production Facility and disposed of in the Saltstone Disposal Facility. Per request of customer, X-TTR-Z-00027, Revision 0, one Saltstone Processing Facility Decontaminated Salt Solution and Z area premix material for the October 2025 semiannual Toxicity Characteristic Leaching Procedure sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request prepared by Savannah River Mission Completion. At 51 days cured, the Saltstone sample was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure. The October 2025 Semiannual Cement-Free grout sample met 61 79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act metals and Underlying Hazardous Constituents and met the Saltstone Production Facility Waste Acceptance Criteria that was in effect at the time of the sample collection at the Salt Waste Processing Facility.

Hsieh, Madison [Savannah River National Laboratory