Comparing Physics Scheme Performance for a Lake Effect Snowfall Event in Northern Lower Michigan

High resolution forecast models, such as those used to predict severe convective storms, can also be applied to predictions of lake effect snowfall. A high resolution WRF model forecast model is provided to support operations at NWS WFO Gaylord, Michigan, using a 12 ]km and 4 ]km nested configuration. This is comparable to the simulations performed by other NWS WFOs adjacent to the Great Lakes, including offices in the NWS Eastern Region who participate in regional ensemble efforts. Ensemble efforts require diversity in initial conditions and physics configurations to emulate the plausible range of events in order to ascertain the likelihood of different forecast scenarios. In addition to providing probabilistic guidance, individual members can be evaluated to determine whether they appear to be biased in some way, or to better understand how certain physics configurations may impact the resulting forecast. On January 20 ]21, 2011, a lake effect snow event occurred in Northern Lower Michigan, with cooperative observing and CoCoRaHS stations reporting new snow accumulations between 2 and 8 inches and liquid equivalents of 0.1 ]0.25 h. The event of January 21, 2011 was particularly well observed, with numerous surface reports available. It was also well represented by the WRF configuration operated at NWS Gaylord. Given that the default configuration produced a reasonable prediction, it is used here to evaluate the impacts of other physics configurations on the resulting prediction of the primary lake effect band and resulting QPF. Emphasis here is on differences in planetary boundary layer and cloud microphysics parameterizations, given their likely role in determining the evolution of shallow convection and precipitation processes. Results from an ensemble of seven microphysics schemes and three planetary boundary layer schemes are presented to demonstrate variability in forecast evolution, with results used in an attempt to improve the forecasts in the 2011 ]2012 lake effect season.

Molthan, Andrew↗

Validation methods for flight crucial systems

Research to develop techniques that can aid in determining the reliability and performance of digital electronic fault-tolerant systems, that have probability of catastrophic system failure on the order of 10 to the -9th at 10 hours, is reviewed. The computer-aided reliability estimation program (CARE III) provides general-purpose reliability analysis and a design tool for fault-tolerant systems; large reduction of state size; and a fault-handling model based on probabilistic description of detection, isolation, and recovery mechanisms. The application of design proof techniques as part of the design and development of the software implemented fault-tolerance computer is mentioned. Emulation techniques and experimental procedures are verified using specimens of fault-tolerant computers and the capabilities of the validation research laboratory, AIRLAB.

Holt, H. M.↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗