Application of Ocean Thermal Energy Conversion (OTEC) Systems for Powering Safety Monitoring Systems of Offshore Oil and Gas Operations. OESI 2.0 M-1 T-1-P1.1 – Objective 1 Interim Report: Summary of Offshore Oil and Gas Well Monitoring Systems and Process Power Requirements

This report is part of a comprehensive research initiative aimed at evaluating the technoeconomic feasibility of deploying greenhouse gas (GHG) emissions monitoring systems powered by small-scale renewable energy sources on the U.S. Outer Continental Shelf (OCS). The study has three primary objectives: summarizing available GHG monitoring systems for the OCS, modeling a renewable marine energy source (specifically ocean thermal energy conversion, or OTEC), and modeling the collocation of OTEC power sources with offshore oil and gas activities to offset power demand.

02 PETROLEUM↗

Cyber‐physical system testbed for power system monitoring and wide‐area control verification

The electric power system is intrinsically a cyber‐physical system (CPS) with power flowing inthe physical system and information flowing in the cyber‐network. Testbeds arecrucial for understanding the cyber‐physical interactions and provideenvironments for prototyping novel applications. This study proposes afour‐layer architecture for CPS testbeds with emphases on communication networkemulation and networked physical components. A configurable software‐definednetwork is employed to bridge physical components with wide‐area applicationsfor closed‐loop control. In order to distribute physically coupled devices intomultiple software simulations, this study proposes a data broker setup based ona distributed messaging environment to achieve low‐latency data streaming. Thedecoupled design with data streaming allows for building testbed components asmodules and running them in a distributed manner. Case studies verify the databroker setup for low‐latency sensing and actuation, as well as the communicationemulation setup for the desired network latency. Also illustrated is a replayattack scenario using synchrophasors in the Western Electricity CoordinatingCouncil (WECC) 181‐bus system for demonstrating the closed‐loop cyber‐physicalsimulation capability of the testbed.

Cui, Hantao↗

Data Mining and Machine Learning for Power System Monitoring, Understanding, and Impact Evaluation

This chapter presents results from the Big Data analysis framework to improve power system situational awareness and system reliability. For this purpose, a dataset with real-world phasor measurement unit data and historical transmission system outage data has been created and used to carry out the analysis. Several statistical analysis and machine learning methods have been developed and implemented for event and anomaly detection and modeling. Detection and analysis results for actual examples of power system events are presented. Finally, data-driven characterization and risk assessment methods for weather-related extremes in power systems are developed and demonstrated on the Bonneville Power Administration system. These applications demonstrate the capability of Machine Learning (ML) methods to monitor system abnormalities, to predict system events, and to characterize the impact of extreme events on power grid

data mining, power grid, machine learning, anomaly↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗

Roles of Dynamic State Estimation in Power System Modeling, Monitoring and Operation

—Power system dynamic state estimation (DSE) remains an active research area. This is driven by the absence of accurate models, the increasing availability of fast-sampled, time synchronized measurements, and the advances in the capability, scalability, and affordability of computing and communications. This paper discusses the advantages of DSE as compared to static state estimation, and the implementation differences between the two, including the measurement configuration, modeling framework and support software features. The important roles of DSE are discussed from modeling, monitoring and operation aspects for today’s synchronous machine dominated systems and the future power electronics-interfaced generation systems. Several examples are presented to demonstrate the benefits of DSE on enhancing the operational robustness and resilience of 21st century power system through time critical applications. Future research directions are identified and discussed, paving the way for developing the next generation of energy management systems.

Zhao, Junbo↗

Application of Ocean Thermal Energy Conversion (OTEC) Systems for Powering Safety Monitoring Systems of Offshore Oil and Gas Operations, OESI 2.0 M-1 T-1-P1.1 – Objective 3 Report: Collocation of OTEC with Offshore Oil and Gas Activities

This report is a component of a comprehensive research initiative aimed at evaluating the technoeconomic feasibility of deploying Ocean Thermal Energy Conversion (OTEC) systems to power safety monitoring systems for offshore oil and gas operations in the Gulf of America (GOA). The overarching study has three primary objectives: summarizing existing oil and gas equipment monitoring systems, modeling OTEC as a renewable marine energy source, and exploring the collocation of OTEC power sources with offshore oil and gas activities to offset power demand. This report specifically addresses Objective 3, focusing on the integration of OTEC systems with floating oil and gas facilities.

02 PETROLEUM↗

Protection Against Graph-Based False Data Injection Attacks on Power Systems

Graph signal processing (GSP) has emerged as a powerful tool for practical network applications, including power system monitoring. By representing power system voltages as smooth graph signals, recent research has focused on developing GSP-based methods for state estimation, attack detection, and topology identification. Included, efficient methods have been developed for detecting false data injection (FDI) attacks, which until now were perceived as non-smooth with respect to the graph Laplacian matrix. Consequently, these methods may not be effective against smooth FDI attacks. In this paper, we propose a graph FDI (GFDI) attack that minimizes the Laplacian-based graph total variation (TV) under practical constraints. In addition, we develop a low-complexity algorithm that solves the non-convex GDFI attack optimization problem using ell_1-norm relaxation, the projected gradient descent (PGD) algorithm, and the alternating direction method of multipliers (ADMM). We then propose a protection scheme that identifies the minimal set of measurements necessary to constrain the GFDI output to high graph TV, thereby enabling its detection by existing GSP-based detectors. Our numerical simulations on the IEEE-57 bus test case reveal the potential threat posed by well-designed GSP-based FDI attacks. Moreover, we demonstrate that integrating the proposed protection design with GSP-based detection can lead to significant hardware cost savings compared to previous designs of protection methods against FDI attacks.

Morgenstern, Gal↗

Synchronized Waveforms – A Frontier of Data-Based Power System and Apparatus Monitoring, Protection, and Control

Voltage and current waveforms contain the most authentic and granular information on the behaviors of power systems. In recent years, it has become possible to synchronize waveform data measured from different locations. Thus large-scale coordinated analyses of multiple waveforms over a wide area are within our reach. This development could unleash a set of new concepts, strategies, and tools for monitoring, protecting, and controlling power systems and apparatuses. This paper presents an in-depth review and analysis of the advancements in synchronized waveform data, including measurement devices, data characteristics, use cases, and comparisons with synchrophasor data. Based on the findings, five strategies are proposed to discover and develop synchronized waveform based applications over multiple application areas. The paper also presents three complementary measurement platforms and two data screening algorithms for application implementation. It further discusses committee activities and standard developments useful to explore the full potential of the data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Robust Yule-Walker Method for Online Monitoring of Power System Electromechanical Modes of Oscillation

Reliable power system operation requires that system operators maintain a satisfactory small-signal stability margin at all times. Mode meters allow system operators to continuously monitor the stability margin by analyzing synchrophasor measurements. Experience with mode meters at the Bonneville Power Administration (BPA) has revealed that mode meters sometimes suffer severe bias following transient disturbances. In this paper, a robust version of the Yule-Walker mode meter algorithm is proposed to mitigate this bias. The robust capability is introduced by modifying the estimator of the autocovariance sequence (ACS) on which the algorithm depends. Tests with field-measured data demonstrate that the robust Yule-Walker (RYW) algorithm significantly outperforms its conventional counterpart and is better able to provide system operators with accurate information about the system's stability margin.

Follum, James D.↗

PMU Data Quality and Sensor Health Monitoring

Phasor Measurement Units (PMUs) play a critical role in the evolution of the electric power industry by providing high-precision, real-time monitoring of essential power system metrics. However, effectively detecting abnormalities and critical events from PMU data is a complex task, complicated by intricate temporal patterns, a scarcity of labeled data for training algo- rithms, and constraints on online computational power. In this study, we apply TranAD, an innovative algorithm that combines transformer architectures with the refinement of adversarial learning, to both synthetic and real-world PMU datasets for developing a data quality and sensor online health monitoring platform for utilities. Our findings reveal that TranAD not only provides efficient detection and localization but also enhances the detail with which abnormalities are detected, marking a a significant step forward in the field of clean data acquisition processes for power system monitoring

deep neural network, machine learning (ML)↗

System and method for monitoring power consumption to detect malware

A system and method (referred to as the system) detects malware, viruses, and/or malicious activity by generating a direct current source power consumption profile by causing a monitored device to execute a fully automated recurrent software operation. The system receives by an automated detection system, the direct current source power consumption profile generated by an intelligent power sensor and generates by a detection engine, a power security profile that identifies suspicious code by profiling direct current consumed by monitored type devices. The system executes a detection engine remote from the monitored device that identifies an infected device.

97 MATHEMATICS AND COMPUTING↗

A Review of Edge Computing Technology and Its Applications in Power Systems

Recent advancements in network-connected devices have led to a rapid increase in the deployment of smart devices and enhanced grid connectivity, resulting in a surge in data generation and expanded deployment to the edge of systems. Classic cloud computing infrastructures are increasingly challenged by the demands for large bandwidth, low latency, fast response speed, and strong security. Therefore, edge computing has emerged as a critical technology to address these challenges, gaining widespread adoption across various sectors. This paper introduces the advent and capabilities of edge computing, reviews its state-of-the-art architectural advancements, and explores its communication techniques. A comprehensive analysis of edge computing technologies is also presented. Furthermore, this paper highlights the transformative role of edge computing in various areas, particularly emphasizing its role in power systems. It summarizes edge computing applications in power systems that are oriented from the architectures, such as power system monitoring, smart meter management, data collection and analysis, resource management, etc. Additionally, the paper discusses the future opportunities of edge computing in enhancing power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discovery of Signatures, Anomalies, and Precursors in Synchrophasor Data with Matrix Profile and Deep Recurrent Neural Networks (Final Project Report)

The widespread deployment of phasor measurement unit (PMU) across the U.S. together with the burgeoning machine learning technology made it possible to develop data-driven PMU data analytics to improve grid security and reliability in a more insightful and effective manner. Although PMU applications have been explored for over a decade, the representative PMU usage is limited to the bulk power system monitoring mainly due to the data integrity issues associated with PMUs (typically missing, fragmented, and wrongly amplified data). To forge a breakthrough on this stalemate and embrace PMUs for power system control and protection as well, we applied various advanced machine learning and big data analysis technology to the power system event detection and classification as the first step toward the power system control and protection pertaining to grid security enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian High-Rank Hankel Matrix Completion for Nonlinear Synchrophasor Data Recovery

Phasor measurement units (PMUs) provide high temporal-resolution synchrophasor measurements for power system monitoring and control. The frequent data quality issues, such as missing and bad data, prevent the incorporation of synchrophasor data in real-time operations. Most existing data-driven data recovery methods assume the power system dynamics can be approximated by a linear dynamical system, and the recovery performance degrades significantly when the power system is experiencing nonlinear dynamics during significant events. Here, this paper proposes a data-driven Bayesian nonlinear synchrophasor data recovery method (Ba-NSDR) that can recover a consecutive time period of simultaneous data losses or errors across all channels, even when the underlying system is highly nonlinear. The idea is to lift the Hankel matrix of the spatial-temporal synchrophasor data to a higher dimension such that the lifted Hankel matrix is low-rank in that space and can be processed with the kernel trick. Our proposed Bayesian method then infers the probabilistic distributions of synchrophasor from the partial observations. Some distinctive features of Ba-NSDR include an uncertainty index to measure the accuracy of the recovery result and the robustness to parameter selections. Our method is verified on both synthetic and recorded event datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real Time Applications Using Linear State Estimation Technology (RTA/LSE)

Electric Power Group, LLC (EPG) was awarded DOE OE0000849 to design, develop, and demonstrate three real-time applications for monitoring power system stability. The applications use phasor measurements and processing by a linear state estimator (LSE) to improve system visibility and accuracy. These applications leverage the large and expanding phasor measurement systems being deployed by utilities throughout the world, and specifically in the United States. Phasor measurements provide a much more detailed view of the power systems than traditional SCADA systems, so can provide better visibility of events and an early warning of developing problems. These three applications are real-time contingency analysis (RTCA), area angle monitoring (AAM), and a voltage stability index (VSI). The project was fully completed as proposed. All three applications were successfully implemented and demonstrated. There were challenges the caused project delays, however. While the RTCA is based on well-known concepts and readily available tools, its deployment using phasor measurements meant it needed to be adapted to sometimes sparse measurements and limited coverage areas. EPG met these challenges with extensive modeling and testing. The AAM is based on unproven research, so EPG had to deal with a lot of unknowns and develop additional methods for practical implementation. These activities took more time than anticipated, so required extra time for development. In addition, there was difficulty getting adequate measurement locations for successful deployment and utility installation delays. Consequently, the project required a time extension to complete. These three real-time applications, RTCA, AAM, and VSI, use only phasor measurement input. Since they do not require the EMS or other measurement systems, they can serve as a backup and security check for the EMS. Phasor measurements are validated and extended by an LSE. The LSE will always produce an output even when some inputs are impaired, so the RT applications will operate even when the EMS state estimator does not converge and the applications it supports cannot function. Consequently, these RT applications can provide valuable additional reliability for control center operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uncertainty Quantification of Capacitor Switching Transient Location using Machine Learning

Identification of capacitor switching transient location provides valuable insight into the state of the associated equipment. Machine learning (ML) models, and convolutional neural networks (CNNs) in particular, have demonstrated remarkable performance in signal location. However, ML models are data driven whose predictions are affected by noise in data and may also suffer from large extrapolation errors when applied to new conditions. Uncertainty quantification (UQ) is necessary to ensure model trustworthiness and avoid overconfident predictions in extrapolation. Here, in this work, we propose a novel UQ method, called PI3NN, to quantify prediction uncertainty of ML models and integrate the method with CNNs for transient source location. PI3NN calculates Prediction Intervals by training 3 Neural Networks and uses root-finding methods to determine the interval precisely. Additionally, PI3NN can identify out-of-distribution (OOD) data in a nonstationary condition to avoid overconfident prediction. Results indicate that with PI3NN, transient signals are not only correctly identified, but when said signals are subject to corruptions characteristic of an actual power monitoring system (e.g. non-ideal sensors), the model recognizes when it is uncertain about its predictions, effectively letting the user know when to accept or discard the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Realistic Testbed Synthesis for Power System Communication Networks based on Graph Metrics

Communication networks are integral to modern power grid operations and are becoming increasingly critical as grid dynamics speed up and as more controls become closed-loop in form. Focusing on the interdependence between the physical grid and the communication system, we identify several key characteristics and typical graph properties based on analysis of a real communication system for a power grid. Moreover, an automated process was provided for synthetic testbed in the NS-3 simulator for the power system test case, and its network characteristics have been further derived for power system monitoring and control applications

Graph Analysis, Synthetic Testbed, communication n↗

A High-Fidelity Electromagnetic Transient Model of Inverter-based Resources Integrated to an IEEE-9 Bus System for Benchmarking Studies

An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter. These power sources lack the intrinsic behaviors of the standard power plants, presenting specific challenges to system stability. These power sources lack the intrinsic behaviors of the standards power plants and their features are almost entirely defined by the control strategy used on them, presenting specific challenges to system stability as their penetration increases into the already fragile Bulk Power System (BPS). Utilizing renewable energy has a great upside but the electrical industry needs to understand the requirements like performing electromagnetic transient (EMT) simulation studies in planning and/or in interconnection studies. This paper presents the development of a high-fidelity EMT model based on commercial equipment and field parameters, which at the same time aims to study the increasing penetration of IBRs and their impact on the actual BPS. The open-source EMT model developed will be a benchmarking example that can be used to evaluate algorithms in the power grid (including evaluating grid-forming controls, power system monitoring and operation, etc.).

Martinez Montejano, Misael↗