The Ames Power Monitoring System

The Ames Power Monitoring System (APMS) is a centralized system of power meters, computer hardware, and specialpurpose software that collects and stores electrical power data by various facilities at Ames Research Center (ARC). This system is needed because of the large and varying nature of the overall ARC power demand, which has been observed to range from 20 to 200 MW. Large portions of peak demand can be attributed to only three wind tunnels (60, 180, and 100 MW, respectively). The APMS helps ARC avoid or minimize costly demand charges by enabling wind-tunnel operators, test engineers, and the power manager to monitor total demand for center in real time. These persons receive the information they need to manage and schedule energy-intensive research in advance and to adjust loads in real time to ensure that the overall maximum allowable demand is not exceeded. The APMS (see figure) includes a server computer running the Windows NT operating system and can, in principle, include an unlimited number of power meters and client computers. As configured at the time of reporting the information for this article, the APMS includes more than 40 power meters monitoring all the major research facilities, plus 15 Windows-based client personal computers that display real-time and historical data to users via graphical user interfaces (GUIs). The power meters and client computers communicate with the server using Transmission Control Protocol/Internet Protocol (TCP/IP) on Ethernet networks, variously, through dedicated fiber-optic cables or through the pre-existing ARC local-area network (ARCLAN). The APMS has enabled ARC to achieve significant savings ($1.2 million in 2001) in the cost of power and electric energy by helping personnel to maintain total demand below monthly allowable levels, to manage the overall power factor to avoid low power factor penalties, and to use historical system data to identify opportunities for additional energy savings. The APMS also provides power engineers and electricians with the information they need to plan modifications in advance and perform day-to-day maintenance of the ARC electric-power distribution system.

Osetinsky, Leonid↗

Power system monitoring and source control of the Space Station Freedom DC power system testbed

Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the DC Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

Kimnach, Greg L.↗

Power system monitoring and source control of the Space Station Freedom dc-power system testbed

Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the dc Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

Kimnach, Greg L.↗

Description of real-time Ada software implementation of a power system monitor for the Space Station Freedom PMAD DC testbed

The authors describe the Ada language software developed to perform the electrical power system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electric power system to be used in Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 386/20e computers connected through an 802.4 local area network. The power system monitor algorithm comprises several functions, including periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data are collected from the switchgear sensors every 100 ms, then passed through a 2-Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The system monitor required a hardware timer interrupt to activate the data acquisition function. The execution time of the code was optimized by using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities.

Ludwig, Kimberly↗

Description of real-time Ada software implementation of a power system monitor for the Space Station Freedom PMAD DC testbed

The Ada language software development to perform the electrical system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed is described. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electrical power system to be used in the Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 382/20e computers connected through an 802.4 local area network. One of these computers is designated as the control node with the other four acting as subsidiary controllers. The subsidiary controllers are connected to the power control components with a Mil-Std-1553 network. An operator interface is supplied by adding a sixth computer. The power system monitor algorithm is comprised of several functions including: periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data is collected from the switchgear sensors every 100 milliseconds, then passed through a 2 Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The reporting mechanism notifies an operator of any abnormalities in the system. Once per second, the system monitor provides data to the control node for further processing, such as state estimation. The system monitor required a hardware time interrupt to activate the data acquisition function. The execution time of the code was optimized using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities. A summary of the advantages and side effects of this technique are discussed.

Ludwig, Kimberly↗

Alarm- And Power-Monitoring System

Electronic central monitoring system, called Remote Monitor Alarm System, RMAS, used to monitor malfunction alarms and power supplies of remotely located equipment modules of transmitting and receiving equipment in fiber-optic communication network at Kennedy Space Center. Includes central monitoring unit at location convenient for technicians, plus remote terminal unit at each remote site containing equipment to be monitored.

Stute, Rob↗

Automatic calorimetry system monitors RF power

Calorimetry system monitors the average power dissipated in a high power RF transmitter. Sensors measure the change in temperature and the flow rate of the coolant, while a multiplier computes the power dissipated in the RF load.

Harness, B. W.↗

Computer program analyzes and monitors electrical power systems (POSIMO)

Requirements to monitor and/or simulate electric power distribution, power balance, and charge budget are discussed. Computer program to analyze power system and generate set of characteristic power system data is described. Application to status indicators to denote different exclusive conditions is presented.

Jaeger, K.↗

A knowledge-based system for monitoring the electrical power system of the Hubble Space Telescope

The design and the prototype for the expert system for the Hubble Space Telescope's electrical power system are discussed. This prototype demonstrated the capability to use real time data from a 32k telemetry stream and to perform operational health and safety status monitoring, detect trends such as battery degradation, and detect anomalies such as solar array failures. This prototype, along with the pointing control system and data management system expert systems, forms the initial Telemetry Analysis for Lockheed Operated Spacecraft (TALOS) capability.

Eddy, Pat↗

Report of the Power Sub systems Panel

Problems in spacecraft power system design, testing, integration, and operation are identified and solutions are defined. The specific technology development problems discussed include substorm and plasma design data, modeling of the power subsystem and components, power system monitoring and degraded system management, rotary joints for transmission of power and signals, nickel cadmium battery manufacturing and application, on-array power management, high voltage technology, and solar arrays.

Source record↗

Automated management of power systems

APSM (Automated Power System Management) is a technology readiness program underway to develop, evaluate, and demonstrate various techniques involved in power system monitoring, as well as computational and control functions. The demonstration breadboard consists of the Viking Orbiter '75 power subassembly breadboard modified to incorporate dedicated microprocessors and digital interface circuits, as well as test support equipment for both spacecraft and ground computer simulation, fault simulation, and data acquisition.

Imamura, M. S.↗

Anomaly Detection in Power Quality at Data Centers

The goal during my internship at the National Center for Critical Information Processing and Storage (NCCIPS) is to implement an anomaly detection method through the StruxureWare SCADA Power Monitoring system. The benefit of the anomaly detection mechanism is to provide the capability to detect and anticipate equipment degradation by monitoring power quality prior to equipment failure. First, a study is conducted that examines the existing techniques of power quality management. Based on these findings, and the capabilities of the existing SCADA resources, recommendations are presented for implementing effective anomaly detection. Since voltage, current, and total harmonic distortion demonstrate Gaussian distributions, effective set-points are computed using this model, while maintaining a low false positive count.

Grichine, Art↗

Real-time space system control with expert systems

Many aspects of space system operations involve continuous control of real time processes. These processes include electrical power system monitoring, prelaunch and ongoing propulsion system health and maintenance, environmental and life support systems, space suit checkout, onboard manufacturing, and vehicle servicing including satellites, shuttles, orbital maneuvering vehicles, orbital transfer vehicles and remote teleoperators. Traditionally, monitoring of these critical real time processes has been done by trained human experts monitoring telemetry data. However, the long duration of future space missions and the high cost of crew time in space creates a powerful economic incentive for the development of highly autonomous knowledge based expert control procedures for these space systems.

Leinweber, David↗

NASA Tech Briefs, June 2003

Topics covered include: Nulling Infrared Radiometer for Measuring Temperature; The Ames Power Monitoring System; Hot Films on Ceramic Substrates for Measuring Skin Friction; Probe Without Moving Parts Measures Flow Angle; Detecting Conductive Liquid Leaking from Nonconductive Pipe; Adaptive Suppression of Noise in Voice Communications; High-Performance Solid-State W-Band Power Amplifiers; Microbatteries for Combinatorial Studies of Conventional Lithium-Ion Batteries; Correcting for Beam Aberrations in a Beam-Waveguide Antenna; Advanced Rainbow Solar Photovoltaic Arrays; Metal Side Reflectors for Trapping Light in QWIPs; Software for Collaborative Engineering of Launch Rockets; Software Assists in Extensive Environmental Auditing; Software Supports Distributed Operations via the Internet; Software Estimates Costs of Testing Rocket Engines; yourSky: Custom Sky-Image Mosaics via the Internet; Software for Managing Inventory of Flight Hardware; Lower-Conductivity Thermal-Barrier Coatings; Process for Smoothing an Si Substrate after Etching of SiO2; Flexible Composite-Material Pressure Vessel; Treatment to Destroy Chlorohydrocarbon Liquids in the Ground; Noncircular Cross Sections Could Enhance Mixing in Sprays; Small, Untethered, Mobile Roots for Inspecting Gas Pipes; Paint-Overspray Catcher; Preparation of Regular Specimens for Atom Probes; Inverse Tomo-Lithography for Making Microscopic 3D Parts; Predicting and Preventing Incipient Flameout in Combustors; MEMS-Based Piezoelectric/Electrostatic Inchworm Actuator; Metallized Capillaries as Probes for Raman Spectroscopy; Adaptation of Mesoscale Weather Models to Local Forecasting; Aerodynamic Design using Neural Networks; Combining Multiple Gyroscope Outputs for Increased Accuracy; and Improved Collision-Detection Method for Robotic Manipulator.

Source record↗

The effect of on/off indicator design on state confusion, preference, and response time performance, executive summary

Investigated are five designs of software-based ON/OFF indicators in a hypothetical Space Station Power System monitoring task. The hardware equivalent of the indicators used in the present study is the traditional indicator light that illuminates an ON label or an OFF label. Coding methods used to represent the active state were reverse video, color, frame, check, or reverse video with check. Display background color was also varied. Subjects made judgments concerning the state of indicators that resulted in very low error rates and high percentages of agreement across indicator designs. Response time measures for each of the five indicator designs did not differ significantly, although subjects reported that color was the best communicator. The impact of these results on indicator design is discussed.

Donner, Kimberly A.↗

Intelligent data reduction for autonomous power systems

Since 1984 Marshall Space Flight Center was actively engaged in research and development concerning autonomous power systems. Much of the work in this domain has dealt with the development and application of knowledge-based or expert systems to perform tasks previously accomplished only through intensive human involvement. One such task is the health status monitoring of electrical power systems. Such monitoring is a manpower intensive task which is vital to mission success. The Hubble Space Telescope testbed and its associated Nickel Cadmium Battery Expert System (NICBES) were designated as the system on which the initial proof of concept for intelligent power system monitoing will be established. The key function performed by an engineer engaged in system monitoring is to analyze the raw telemetry data and identify from the whole only those elements which can be considered significant. This function requires engineering expertise on the functionality of the system, the mode of operation and the efficient and effective reading of the telemetry data. Application of this expertise to extract the significant components of the data is referred to as data reduction. Such a function possesses characteristics which make it a prime candidate for the application of knowledge-based systems' technologies. Such applications are investigated and recommendations are offered for the development of intelligent data reduction systems.

Floyd, Stephen A.↗

Development of a component centered fault monitoring and diagnosis knowledge based system for space power system

The overall approach currently being taken in the development of AMPERES (Autonomously Managed Power System Extendable Real-time Expert System), a knowledge-based expert system for fault monitoring and diagnosis of space power systems, is discussed. The system architecture, knowledge representation, and fault monitoring and diagnosis strategy are examined. A 'component-centered' approach developed in this project is described. Critical issues requiring further study are identified.

Lee, S. C.↗