Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Future Standard for Reactive Power Measurement

Reactive power is defined for sinusoidal voltage and current. Several different ways to measure the quantity have been developed, and while they all give the same result for sinusoidal voltages and currents, the results are not the same when the inputs are distorted. Work was done with distorted test signals to explore these—sometimes large— differences, and a report summarizing the findings was published by the US National Institute of Standards and Technology (NIST) in 2011. We show in this paper that the differences are smaller, but not negligible, when the waveforms are less distorted. The differences between the results of the various existing methods are discussed from the viewpoint of measurement theory. The paper argues that it is time to select one method. The relevance to the ongoing revision to IEEE standard 1459 (which defines reactive power for the purposes of measurement) is explored.

reactive power, measurement standard, definitions,↗

Fine-Grained Application Energy and Power Measurements on the Frontier Exascale System

The increasing complexity and power/energy demands of heterogeneous exascale systems, such as the Frontier supercomputer, present significant challenges for measuring and optimizing power consumption in applications. Current tools either lack the resolution to capture fine-grained power and energy measurements, fail to validate in-band measurements against out-of-band power sensors, or cannot integrate this information with application performance events in a scalable manner. This paper introduces a novel open-source performance toolkit that integrates extended PAPI components with Score-P plugins to enable in-band, fine-grained power and energy measurements, while also supporting validation using power meter measurements for both CPUs and GPUs. One key contribution is the ability to perform millisecond-level power and energy measurements for AMD MI250X GPUs, mapping them to application performance events within a single trace and measurement system that scales. Our toolkit combines coarse-grained measurements from cray_pm counters with high-resolution metrics from rocm_smi and RAPL, converting GPU instantaneous accumulated energy into power to capture both transient and steady-state power behavior, a capability often missed by out-of-band and monitoring tools. By mapping these metrics to specific application regions, developers can identify energy hotspots, address inefficiencies in GPU kernel execution, and validate in-band measurements against external measurements. We demonstrate the effectiveness of this approach through case studies using benchmarks such as GPU rocblas_sgemm, BLIS c_blas_dgemm, and rocHPL, highlighting the variability of the measurements and the impact of transient power spikes on kernel-level efficiency.

Hernandez Mendoza, Oscar [ORNL] (ORCID:00000002538↗

From IEC 61853 power measurements to PV system simulations.

The IEC 61853 PV module energy rating standard requires measuring module power (and hence efficiency) over a matrix of irradiance and temperature conditions. These matrix points represent nearly the full range of operating conditions encountered in the field in all but the most extreme locations, and create an opportunity to develop alternative approaches to existing modelssuch as the single-diode models and the Sandia Array Performance Modelfor calculating system performance. This report begins by discussing the bilinear interpolation and extrapolation method from IEC 61853-3, and then describes four existing model-based methods that could be used with matrix measurements. Then a new model is developed and all options are compared according to seven objective criteria using the matrix measurements of four PV modules of different technologies. The results show that the new model is an excellent candidate for launching power matrix-based PV system simulations.

14 SOLAR ENERGY↗

Enabling power measurement and control on Astra: The first petascale Arm supercomputer

Astra, deployed in 2018, was the first petascale supercomputer to utilize processors based on the ARM instruction set. The system was also the first under Sandia's Vanguard program which seeks to provide an evaluation vehicle for novel technologies that with refinement could be utilized in demanding, large-scale HPC environments. In addition to ARM, several other important first-of-a-kind developments were used in the machine, including new approaches to cooling the datacenter and machine. Here we document our experiences building a power measurement and control infrastructure for Astra. While this is often beyond the control of users today, the accurate measurement, cataloging, and evaluation of power, as our experiences show, is critical to the successful deployment of a large-scale platform. While such systems exist in part for other architectures, Astra required new development to support the novel Marvell ThunderX2 processor used in compute nodes. In addition to documenting the measurement of power during system bring up and for subsequent on-going routine use, we present results associated with controlling the power usage of the processor, an area which is becoming of progressively greater interest as data centers and supercomputing sites look to improve compute/energy efficiency and find additional sources for full system optimization.

97 MATHEMATICS AND COMPUTING↗

Correction for Neutral Pressure-Driven Signal in Radiated Power Measurements on Proto-MPEX

A pinhole camera using four-channel resistive bolometers was designed and implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to measure the plasma radiated power. Quantification of the radiated power is required for comprehensive power balance assessments but faces unique challenges on linear plasma devices due to weak absolute signal, compared to typical use in toroidal fusion plasmas, and high neutral pressure changes. Around 1 mTorr, the pressure-driven signal contribution was shown to overwhelm the radiated power signal in Proto-MPEX, found to be ~3 μW . Since the pressure-driven signals could not be predicted from first principle arguments, the signals were corrected using empirical models that take two experimental pressure measurements and the raw bolometer signal to reveal the radiated power signals. Four “gas-only” Proto-MPEX shots were taken, without the radio frequency (rf) plasma discharge, to train, optimize, and validate empirical models. The data included two pressure measurements at different locations along with the bolometer signal. Multiple models were tested; partial least-squares regression with a cross correlation method to account for the time offset in the pressure measurements provided the best combination of accuracy and stability. The model was validated to have a modeling error of 0.0036 V, which was lower than 10% of the expected radiated power signal. The model was tested on a different “gas-only” shot with a complete time-series data. For plasma operation shots, the corrected bolometer measurements were compared with an absolute extreme ultraviolet photodiode measurement and similarities and differences are discussed.

Lee, Seungsup↗

Plasma stopping-power measurements reveal transition from non-degenerate to degenerate plasmas

Physically realized electron gas systems usually reside in either the quantum non-degenerate or fully degenerate limit, where the average de Broglie wavelength of the thermal electrons becomes comparable with the interparticle distance between electrons. A few systems, such as young brown dwarfs and the cold dense fuels created in imploded cryogenic capsules at the National Ignition Facility, lie between these two limits and are partially degenerate. The National Ignition Facility has the unique capability of varying the electron quantum degeneracy by adjusting the laser drive used to implode the capsules. This allows experimental studies of the effects of the degeneracy level on plasma transport properties. By measuring rare nuclear reactions in these cold dense fuels, we show that the electron stopping power, which is the rate of energy loss per unit distance travelled by a charged particle, changes with increasing electron density. We observe a quantum-induced shift in the peak of the stopping power using diagnostics that measure above and below this peak. The observed changes in the stopping power are shown to be unique to the transition region between non-degenerate and degenerate plasmas. Furthermore, our results support the screening models applied to partially degenerate astrophysical systems such as young brown dwarfs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of Power Measurements Using Adaptive Filters

With the advent of smart grid concept, Internet of Things (IoT) and the deployment of smart meters, the cyberattack threats on power networks have increased due to the use of communication systems that can be accessed by adversaries. Attackers will have the ability to manipulate the outcomes of smart meters which in turn influence the core application of Energy Management System 9EMS): State Estimation (SE). Bad data analytic tools may fail to detect some attacks into measurements. Meanwhile, Machine Learning (ML) solutions have been proposed for detecting False Data Injection (FDI) attacks. However, there is a lack of ML time-series solutions presented in the state-of-the-art that is yet to be complex. In signal processing, time-series solutions do not only consider the signal, but also the statistics of the signal over time. Therefore, in this paper, a machine learning for time-series solutions is presented as an application to model the measurements of the power grid that are used in SE. The presented model takes into account adaptive linear and non-linear filters: Finite Impulse Response (FIR), and Infinite Impulse Response (IIR). The presented models are implemented and performed on the IEEE-118 bus system. The results indicate the advantage of applying those filters over the state-of-the-art machine learning solutions.

Hamad, Khaled↗

The first high-redshift cavity power measurements of cool-core galaxy clusters with the International LOFAR Telescope

Radio-mode feedback associated with the active galactic nuclei (AGNs) at the cores of galaxy clusters injects a large amount of energy into the intracluster medium (ICM), offsetting radiative losses through X-ray emission. This mechanism prevents the ICM from rapidly cooling down and fueling extreme starburst activity as it accretes onto the central galaxies, and it is therefore a key ingredient in the evolution of galaxy clusters. However, the influence and mode of feedback at high redshifts (z ∼ 1) remains largely unknown. Low-frequency sub-arcsecond-resolution radio observations taken with the International LOFAR Telescope have demonstrated their ability to assist X-ray observations with constraining the energy output from the AGNs (or “cavity power”) in galaxy clusters, thereby enabling research at higher redshifts than before. In this pilot project, we tested this hybrid method on a high-redshift (0.6 < z < 1.3) sample of 13 galaxy clusters for the first time with the aim of verifying the performance of this method at these redshifts and providing the first estimates of the cavity power associated with the central AGN for a sample of distant clusters. We were able to detect clear radio lobes in three out of 13 galaxy clusters at redshifts of 0.7 < z < 0.9, and we used these detections in combination with ICM pressures surrounding the radio lobes obtained from standard profiles to calculate the corresponding cavity powers of the AGNs. Combining our results with the literature, the current data appear to suggest that the average cavity power peaked at a redshift ofz ∼ 0.4 and slowly decreases toward higher redshifts. However, we require more and tighter constraints on the cavity volume and a better understanding of our observational systematics to confirm any deviation of the cavity power trend from a constant level.

Astronomy & Astrophysics↗

Testing Low-Loss Microstrip Materials with MKIDs for Microwave Applications

Future measurements of the millimeter-wavelength sky require a low-loss superconducting microstrip, typically made from niobium and silicon-nitride, coupling the antenna to detectors. Here, we propose a simple device for characterizing these low-loss microstrips at 150 GHz. In our device we illuminate an antenna with a thermal source and compare the measured power at 150 GHz transmitted down microstrips of different lengths. The power measurement is made using Microwave Kinetic Inductance Detectors (MKIDs) fabricated directly onto the microstrip dielectric, and comparing the measured response provides a direct measurement of the microstrip loss. Our proposed structure provides a simple device (4 layers and a DRIE etch) for characterizing the dielectric loss of various microstrip materials and substrates. We present initial results using these devices. We demonstrate that the millimeter wavelength loss of microstrip lines, a few tens of millimeters long, can be measured using a practical aluminum MKID with a black body source at a few tens of Kelvin.

47 OTHER INSTRUMENTATION↗

Efficiency, Power Loss, and Power Factor Measurement of Quadrupole Magnet Power Supplies at the Spallation Neutron Source

The linear accelerator (LINAC) quadrupole magnets are powered by 42 silicon-controlled rectifier (SCR) based power supplies at the Spallation Neutron Source (SNS) facility of Oak Ridge National Laboratory. These 35V, 525A power supplies are bulky, inefficient and require both air and water cooling. The reliability of the SNS facility is impacted due to water leaks internal to power supplies and current readback issues associated with their unique control system interface, resulting in multiple downtime events. Hence, an alternate solution is necessary for the continued reliable operation of the SNS. To mitigate the above-mentioned problems, this paper proposes the use of off-the-shelf Switch Mode Power Supplies (SMPS) rated for 20V, 500A with serial control interface. These SMPS are air-cooled, more efficient and more compact owing to their switching speeds of approximately 160 kHz. The performance enhancements of the SMPS in comparison with the existing SCR power supply are discussed in detail in this paper. The features of the SMPS, along with experimental results for both power supplies, like efficiency, power losses and stability, are presented. Ongoing work is also discussed.

Harave, Sudarshan↗

Measuring stopping power in warm dense matter plasmas at OMEGA

A platform has been developed for accurately measuring the stopping power of high energy protons through warm dense matter (WDM) plasmas characterized by x-ray Thomson scattering. Here, in this work, stopping power measurements were successfully made through both WDM Beryllium and Boron plasmas. In the Boron experiments, an increase in stopping was observed over their cold target counter-parts. This increase in stopping was shown to agree well with models that account for the partial ionization of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Roadmap for Advanced Power System Measurements

Conditions in the electric power grid are changing rapidly. Changes are driven, in particular, by the increased penetration of renewable resources in the generation mix. Part of the solution to dealing with the changing conditions is the better use of measurement systems, taking advantage of the better understanding of measurements that was heralded by digital technology. Another part of the solution is the communication of samples of the directly observable voltages and currents by means of continuous point-on-wave values. The increased bandwidth capability of such a system allows more complicated measurement models to be built at the point of use. Additional measurements and analyses can then be performed. This Roadmap hinges on these two aspects of measuring: improved measurements supported by high-bandwidth (raw data) communications. Following an introduction to the overall subject, the report explores the impact of what can be thought of as the digital revolution in measurement. In essence, that revolution has served to clarify ideas about measurement and is continuing to lead to improved processes. An extensive survey of the relevant literature was performed . Webinars were held to learn from the wider community of practitioners. Based on this information, a number of gaps were identified whose continued existence would hamper the solution of the challenges now facing measurement and communication in the power grid. The underlying value propositions are interoperability (presently not very satisfactory in many measurements); greater (and less challenging) adoption of distributed energy resources; and improved international competitiveness. Underlying all that, of course, is progress toward a more reliable and resilient power system. The identified gaps were addressed in four major thrusts: technology deployment and demonstration, education, instrumentation testing and standards, and analytical methods. For each of the thrusts, multiple goals are defined to guide the implementation. The thrusts were designed to close gaps and unlock high-value use cases. After discussing the literature review, gap analysis, high-value use cases, and research thrusts in chapters 2-5, the report culminates in chapter 6 with a roadmap that links each aspect together to form a unified plan. Developing a research portfolio aligned with this plan will ensure that advanced measurement systems are in place to support reliable operation of the power system as it modernizes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Platform development for dE/dx measurements on short-pulse laser facilities

We illustrate generating benchmark data on charged-particle stopping power in dense plasma is a challenge, motivating new experimental platforms for facilities such as short-pulse lasers. We report on several experiments that aimed to develop a platform for high-precision stopping power measurements at OMEGA EP, specifically developing target-normal sheath acceleration (TNSA) sources, proton isochoric heating, and radiatively heated foams. Integrated experiments were performed to measure stopping power, but several phenomena have been identified that would need to be mitigated for a stopping-power measurement, including irreproducibility of the TNSA sources, spurious electromagnetic fields around proton-heated targets, and cross-talk between the source and subject targets. This work provides a basis for potential future work towards mitigating these problems and performing stopping-power measurements, and is also valuable data for general understanding of TNSA and proton isochoric heating experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noncontact Monitoring of Overhead Transmission Lines Using Space Potential Phasor Measurements

Power system reliability requirements necessitate the development of measurement systems to monitor the operational state of critical transmission lines. Here in this article, a novel noncontact method for monitoring overhead transmission lines is proposed. The method is based on measuring the amplitude and relative phase of the transmission line's space potential at two or more strategically located points in space along with the use of passive phase shifters to enhance the sensitivity of the measurements. Applications of voltage unbalance and conductor sag measurements are demonstrated along with the results of conductor sag measurements on an operating 230-kV transmission line. It is shown that using enhanced relative phase measurements can significantly improve the sensitivity of the measurements.

47 OTHER INSTRUMENTATION↗

Advanced Power Systems Measurements: A Literature Review

In 2020, a literature survey was performed as part of a project aimed at producing guidance for the Department of Energy in the form of a Roadmap. The topic of the Roadmap was measurement. That was viewed as being generally underrepresented in consideration of sensing and measurement or instrumentation and measurement. Sensing is just the beginning of a process, and the instrument is just the container for the process. Measurement, the experimental process, has acquired a considerable body of theory over the last few decades, theory that is not widely taught and disseminated. The results of the survey can be said broadly to reflect that lack of appreciation. Specifically, the review found that there is support for the development of a more “capable” PMU. New algorithms and new documentary standards will be needed. Some of the findings are: (1) Point-on-wave technology adds new capability to the existing suite of measurements, and could allow for improved operation and protection (2) Power quality analysis has historically been concerned with assessment of how non-sinusoidal the delivered voltage shows promise in signature recognition, a departure from the modeling that has historically characterized power system measurements. (3) The PMU is assed as being a remarkable measurement system, but its performance is held back by the lack of understanding of the measurement theory underpinning its operation. (4) The PMU is being considered for application in the distribution system. There is a danger that it will be seen only in the light of the successful PMU implementation in transmission, and the two have different requirements. These various expansions of measurements will no doubt benefit from a better appreciation of the theoretical aspects of measurement. In this, and other, regards, our survey of the literature has identified gaps as well as possibilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗