Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power distribution lines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Voltages induced on a power distribution line by overhead cloud lightning

Voltages induced by overhead cloud lightning on a 448 m open circuited power distribution line and the corresponding north-south component of the lightning magnetic field were simultaneously measured at the NASA Kennedy Space Center during the summer of 1986. The incident electric field was calculated from the measured magnetic field. The electric field was then used as an input to the computer program, EMPLIN, that calculated the voltages at the two ends of the power line. EMPLIN models the frequency domain field/power coupling theory found, for example, in Ianoz et al. The direction of the source, which is also one of the inputs to EMPLIN, was crudely determined from a three station time delay technique. The authors found reasonably good agreement between calculated and measured waveforms.

Yacoub, Ziad↗

Measurements of induced voltages and currents in a distribution power line and associated atmospheric parameters

The frequency and intensity of thunderstorms around the Kennedy Space Center (KSC) has affected scheduled launch, landing, and other ground operations for many years. In order to protect against and provide safe working facilities, KSC has performed and hosted several studies on lightning phenomena. For the reasons mentioned above, KSC has established the Atmospheric Science Field Laboratory (ASFL). At these facilities KSC launches wire-towing rockets into thunderstorms to trigger natural lightning to the launch site. A program named Rocket Triggered Lightning Program (RTLP) is being conducted at the ASFL. This report calls for two of the experiments conducted in the summer 1988 Rocket Triggered Lightning Program. One experiment suspended an electric field mill over the launching areas from a balloon about 500 meters high to measure the space charges over the launching area. The other was to connect a waveform recorder to a nearby distribution power line to record currents and voltages wave forms induced by natural and triggered lightning.

Santiago-Perez, Julio↗

Local and utility-wide cost allocations for a more equitable wildfire-resilient distribution grid

Climate-induced extreme weather conditions make electricity infrastructure more vulnerable. They increase the risk of power-line-ignited wildfires which can, in turn, jeopardize electric power delivery. Here, leveraging machine learning, we show that lower-income communities in California not only have lower fractions of power distribution lines undergrounded, but overhead lines and poles in their neighbourhoods are also more vulnerable to wildfires. Should they bear the cost of undergrounding fire-prone lines themselves, they would have to pay a disproportionately higher cost per household. We propose a cost allocation scheme with an income threshold below which the cost is borne by utility-wide ratepayers and above which the cost is borne locally. This scheme can not only minimize the average of undergrounding costs per household as a share of income, but also homogenize such cost–income ratios across communities. Furthermore, our research demonstrates the opportunity to appropriately integrate existing policies to make electricity infrastructure affordable, equitable and reliable amidst climate change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Circuit for Communication Over Power Lines

Many distributed systems share common sensors and instruments along with a common power line supplying current to the system. A communication technique and circuit has been developed that allows for the simple inclusion of an instrument, sensor, or actuator node within any system containing a common power bus. Wherever power is available, a node can be added, which can then draw power for itself, its associated sensors, and actuators from the power bus all while communicating with other nodes on the power bus. The technique modulates a DC power bus through capacitive coupling using on-off keying (OOK), and receives and demodulates the signal from the DC power bus through the same capacitive coupling. The circuit acts as serial modem for the physical power line communication. The circuit and technique can be made of commercially available components or included in an application specific integrated circuit (ASIC) design, which allows for the circuit to be included in current designs with additional circuitry or embedded into new designs. This device and technique moves computational, sensing, and actuation abilities closer to the source, and allows for the networking of multiple similar nodes to each other and to a central processor. This technique also allows for reconfigurable systems by adding or removing nodes at any time. It can do so using nothing more than the in situ power wiring of the system.

Krasowski, Michael J.↗

Modular Hybrid Solid State Transformer (H-SST) for Next Generation Flexible and Adaptable Large Power Transformer (LPT) (Final Technical Report)

A 500 kVA HSST, the world first of such system, has been successfully developed. The HSST has the capability to regulate the power flow of the transmission or distribution power lines, or provide voltage regulation. The HSST design is modular therefore it has the ability to be connected in series of parallel to form a large power transformer with smart controllability. The project has enabled a high TRL level prototype be demonstrated at University of Texas at Austin which can lead to additional commercialization and demonstration opportunities. A large number of students were trained under this program that will benefit the power grid industry. A number of publications are published at well known international conferences and journals, further accomplish the mission of knowledge development and dissemination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase-to-phase-ground and phase-to-ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase-to-ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and nonfaulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

42 ENGINEERING↗

Olympus System Backplane Definition

The purpose of this document is to define the backplane of the Olympus firing system, a modular system based on SpaceWire communication between modules. The backplane provides the connection between the modules, controller (embedded in the front module), the SpaceWire router, and an alternative switch. Those connections include SpaceWire links, interlocks, a key, a dead-man switch (DMS)/charge, timing lines, power distribution, geographical addresses, and communication to the human-machine interface (HMI). This backplane is based on the VMEBus International Trade Association (VITA) 46 Specification (VPX) and OpenVPX standards for a 3U backplane. Unless otherwise specified, those standards apply for signal definitions and mechanical specifications.

42 ENGINEERING↗

Innovation in Building Design

Thomas & Betts Corporation's Flat Conductor Cables, or FCC, were developed of necessity as aircraft and spacecraft became increasingly complex. In order to reduce size and weight of components, the use of thin flat wire instead of relatively thick and protrusive round cable, provided a dramatic reduction of the space occupied by the many miles of power distribution lines in an aerospace vehicle. Commercially, FCC offers cost savings in simplified building construction, reduced installation time and ease of alteration.

Source record↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

Transmission line design for a power distribution system at 20 kHz for aircraft

A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.

Zelby, L. W.↗

Longitudinal variations of very-low-frequency chorus activity in the magnetosphere - Evidence of excitation by electrical power transmission lines

The distribution of VLF chorus in the high-altitude magnetosphere as detected by the Ogo 3 satellite was investigated. Chorus occurrence frequency over 4,668 samples of 5 min of broadband data was computed for Northern Hemisphere bins of 10 deg by 10 deg in dipole invariant latitude and longitude. Peaks in activity were noted over Alaska, the eastern U.S. and Canada, western Europe, and western Siberia, and were shown not to be the result of biased sampling. It is suggested that power line radiation of only about 1 W or less at a given harmonic frequency may be sufficient to stimulate the observed chorus activity and that such power levels can be expected in industrial areas or from large distribution networks. Preliminary results show that chorus starting frequencies are highly correlated with 60 Hz harmonics in the American sector and with 50 Hz harmonics in the European sector.

Luette, J. P.↗

Supply voltage decoupling circuits for voltage droop mitigation

Circuits and methods are provided for utilizing decoupling capacitors to mitigate voltage droop on power supply lines of a power distribution network. A power supply line is capacitively decoupled using a first decoupling capacitor connected to the power supply line and charged to a first voltage level of the power supply line. A second decoupling capacitor is pre-charged to a second voltage level greater than the first voltage level and held in standby. A control circuit determines or predicts an occurrence of a droop event in which the first voltage decreases to a level which is at or below a droop threshold voltage level, and selectively connects the pre-charged second decoupling capacitor to the power supply line to source additional boosting current through discharging of the second decoupling capacitor and thereby capacitively decouple the power supply line using the higher second voltage and additional boosting current.

Zhang, Xin↗

Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

Jeffries, K. S.↗

Distributed Outage Detection in Power Distribution Networks

Real time topology knowledge is essential for situational awareness of power distribution networks. Line outages change the topology of a distribution network. Hence, outage detection is an important task. Most of the existing outage detection algorithms are centralized, in which sensors communicate their data to a control center which performs outage detection using the received data. However, with the increasing size of the distribution network and with different areas of the network being monitored by different operators, communication is a bottleneck and scalability is a major concern. To address these issues, we propose a novel outage detection algorithm using a divide and conquer approach. First, we divide a distribution network into sub-networks, such that outage detection can be run in parallel in each sub-network independently ensuring scalability to large networks. Further, to reduce the latency, bandwidth and attenuation challenges associated with communications in a large network, we divide each sub-network into multiple control areas which communicate only with their neighbors. We employ a distributed iterative load estimation across the control areas of each sub-network and then use the load estimate for local outage detection in each control area. Here, the performance of our algorithm is evaluated for multiple feeder models and compared against traditional centralized outage detection algorithms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Considerations for AMI-Based Operations for Distribution Feeders

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automatic Monitoring Of Complicated Systems

Collection of computer programs developed for expert computer system performing complicated, tedious, and repetitive portions of analysis of telemetry data from spacecraft. Provides nonstop, accurate surveillance of incoming data, also frees operators to concentrate their expertise on unexpected abnormal operating conditions. When unable to explain discrepancies with certainty resulting from data out of synchronization or other falso-alarm conditions, triggers alarm devices to request assistance from designated individuals. Concept useful in such terrestrial systems as production lines, power-distribution networks, chemical processes, large airplanes, and other assemblies of interdependent equipment.

Schwuttke, Ursula M.↗

The Effectiveness of Power Distribution Systems for Deployment on the Lunar Surface

Lunar habitation missions are currently being planned to have astronauts return to the moon by the mid 2020’s with a sustained lunar presence by the end of the decade. The various landed modules needed to support the missions are expected to be distributed around Shackleton Crater at distances ranging from 1 to 15 km and with power needs ranging from 10 kW to 50kW. Current plans call for a solar array to be installed on the rim of the crater that receives near-constant sunlight year around with a power distribution system that transfers power from the source to consumers. This paper details several power distribution systems: DC transmission lines, radio frequency power beaming, and optical power beaming. Sizing algorithms for each of these distributions systems along with their necessary subsystems were developed from literature and subject matter expertise input. Several experiments were then conducted to determine the performance of the systems along with their sensitivities to changes in assumptions for various sub-components. The defined Figures of Merit enable mission designers to select the best power distribution system for each possible power consumer mission scenario. The experimental results were analyzed and compiled into a set of figures that highlight the conditions for which a certain system outperforms the other.

Bradford Robertson↗

The Effectiveness of Power Distribution Systems for Deployment on the Lunar Surface

Lunar habitation missions are currently being planned to have astronauts return to the moon by the mid 2020’s with a sustained lunar presence by the end of the decade. The various landed modules needed to support the missions are expected to be distributed around Shackleton Crater at distances ranging from 1 to 15 km and with power needs ranging from 10 kW to 50kW. Current plans call for a solar array to be installed on the rim of the crater that receives near-constant sunlight year around with a power distribution system that transfers power from the source to consumers. This paper details several power distribution systems: DC transmission lines, radio frequency power beaming, and optical power beaming. Sizing algorithms for each of these distributions systems along with their necessary subsystems were developed from literature and subject matter expertise input. Several experiments were then conducted to determine the performance of the systems along with their sensitivities to changes in assumptions for various sub-components. The defined Figures of Merit enable mission designers to select the best power distribution system for each possible power consumer mission scenario. The experimental results were analyzed and compiled into a set of figures that highlight the conditions for which a certain system outperforms the other.

Bradford Robertson↗