Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using Demanded Power and RDE Aggressiveness Metrics to Analyze the Impact of CACC Aggressiveness on Heavy Duty Platooning Power Consumption

Presently, a main mobility sector objective is to reduce its impact on the global greenhouse gas emissions. While there are many techniques being explored, a promising approach to improve fuel economy is to reduce the required energy by using slipstream effects. This study analyzes the demanded engine power and mechanical energy used by heavy-duty trucks during platooning and non-platooning operation to determine the aerodynamic benefits of the slipstream. A series of platooning tests utilizing class 8 semi-trucks platooning via Cooperative Adaptive Cruise Control (CACC) are performed. Comparing the demanded engine power and mechanical energy used reveals the benefits of platooning on the aerodynamic drag while disregarding any potential negative side effects on the engine. However, energy savings were lower than expected in some cases. It was hypothesized that the CACC may have amplified transient platooning events relative to the individual truck baseline results, hampering the potential energy savings. Therefore, the impact of the controller on the observed driving style was analyzed in detail. In order to quantify the transient operational characteristics of the experimental trials, metrics from the European Real Driving Emissions (RDE) legislation were modified to serve as metrics of aggressiveness during platooning. The metrics (v · apos)95 and Relative Positive Acceleration (RPA) were calculated for platooning and non-platooning runs. These results indicate that the CACC induces small acceleration events during platooning to retain the commanded longitudinal separation between vehicles. These small acceleration events increase following vehicle aggressiveness during platooning and prevent the following vehicles from obtaining maximum energy savings. Moreover, a correlation between the RDE metric (v · apos)95 and energy savings is developed. Hence, this work establishes the ability of RDE metrics to assess CACC impacts on platoon energy savings.

European Real Driving Emissions, RDE, greenhouse g↗

The Challenge of Disproportionate Importance of Temporal Features in Predicting HPC Power Consumption

In this work, we demonstrate the challenges in predicting HPC cluster power consumption in the face of significant temporal skew in power consumption behavioral patterns. Predicting large power swings that extend several megawatts has significant operational value for HPC centers, however, prediction is challenging due to the relative rarity of such events and also due to the abrupt or disjoint deviation from the average power consumption levels. To study the impact of this challenge, we have trained a recurrent neural network (RNN) as a reasonably sophisticated model to predict power consumption of the one-year worth of node power consumption data from the Summit supercomputer located in the Oak Ridge Leadership Computing Facility. By studying the prediction results, we have found that although simple usage of RNN models can provide good results on average power consumption levels, it would fail at predicting the power swings that have more operational value. With such results, we discuss potential next steps in addressing such issues aiming towards a robust usage of power prediction techniques in HPC operations.

Li, Chengcheng↗

System and method for monitoring power consumption to detect malware

A system and method (referred to as the system) detects malware, viruses, and/or malicious activity by generating a direct current source power consumption profile by causing a monitored device to execute a fully automated recurrent software operation. The system receives by an automated detection system, the direct current source power consumption profile generated by an intelligent power sensor and generates by a detection engine, a power security profile that identifies suspicious code by profiling direct current consumed by monitored type devices. The system executes a detection engine remote from the monitored device that identifies an infected device.

97 MATHEMATICS AND COMPUTING↗

Gated ring oscillator with constant dynamic power consumption

A pure digital ring oscillator with constant power consumption as oscillation frequency is adjusted. Circuit topology includes a multiplexer implemented in NAND gates and a delay element positioned after a path selection NAND gate of that multiplexer such that delay element transistors may not toggle if the non-delaying signal path is selected. Assuming a delay element oscillation frequency f and a total capacitance C, and also assuming a plurality N of delay gates each characterized by a propagation delay t1 and a capacitance C1 such that C=C1*N, the ring oscillator of the present invention is characterized by a C value that is proportional to N and an f value that is inversely proportional to N. Furthermore, each of the N delay gates as well as the input and output gates of the multiplexer are characterized by a common capacitance-to-propagation delay ratio=C1/t1.

Wu, Jinyuan↗

Gated ring oscillator with constant dynamic power consumption

A pure digital ring oscillator with constant power consumption as oscillation frequency is adjusted. Circuit topology includes a multiplexer implemented in NAND gates and a delay element positioned after a path selection NAND gate of that multiplexer such that delay element transistors may not toggle if the non-delaying signal path is selected. Assuming a delay element oscillation frequency f and a total capacitance C, and also assuming a plurality N of delay gates each characterized by a propagation delay t1 and a capacitance C1 such that C=C1*N, the ring oscillator of the present invention is characterized by a C value that is proportional to N and an f value that is inversely proportional to N. Furthermore, each of the N delay gates as well as the input and output gates of the multiplexer are characterized by a common capacitance-to-propagation delay ratio=C1/t1.

Wu, Jinyuan↗

The MURAVES muon telescope: a low power consumption muon tracker for muon radiography applications

Muon Radiography or muography is based on the measurement of the absorption or scattering of cosmic muons, as they pass through the interior of large scale bodies, In particular, absorption muography has been applied to investigate the presence of hidden cavities inside the pyramids or underground, as well as the interior of volcanoes’ edifices. The MURAVES project has the challenging aim of investigating the density distribution inside the summit of Mt. Vesuvius. The information, together with that coming from gravimetric measurements, is useful as input to models, to predict how an eruption may develop. The MURAVES apparatus is a robust and low power consumption muon telescope consisting of an array of three identical and independent muon trackers, which provide in a modular way a total sensitive area of three square meters. Each tracker consists of four doublets of planes of plastic scintillator bars with orthogonal orientation, optically coupled to Silicon photomultipliers for the readout of the signal. The muon telescope has been installed on the slope of the volcano and has collected a first set of data, which are being analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probabilistic Power Consumption Modeling for Commercial Buildings Using Logistic Regression Markov Chain

The total energy consumed by buildings takes up to 40% of U.S. energy use, in which a large portion is contributed by commercial buildings. Building performance optimization is desirable but requires accurate building models with uncertainties taken into account. This paper proposes a novel probabilistic modeling method using Logistic Regression Markov Chain (LRMC). The LRMC model enhances the performance of traditional Markov Chain (MC) models by adopting time-variant transition matrices calibrated using logistic regression with exogenous inputs. Compared with existing building models, the proposed model produces accurate multi-step modeling results with full probability distribution. The proposed probabilistic building model is tested using actual commercial building measurements and modeling performance is evaluated with two probabilisitc metrics. The results show that the LRMC model has higher accuracy than traditional MC model and Logistic Regression (LR) model in that it yields lower error scores under both evaluation metrics.

Building modeling↗

Recent Developments in the General Atomic and Molecular Electronic Structure System

A discussion of many of the recently implemented features of GAMESS (General Atomic and Molecular Electronic Structure System) and LibCChem (the C++ CPU/GPU library associated with GAMESS) is presented. These features include fragmentation methods like the fragment molecular orbital, effective fragment potential and effective fragment molecular orbital methods, hybrid MPI/OpenMP approaches to Hartree-Fock and resolution of the identity second order perturbation theory. Many new coupled cluster theory methods have been implemented in GAMESS, as have multiple levels of density functional/tight binding theory. The role of accelerators, especially graphical processing units, is discussed in the context of the new features of LibCChem, as is the associated problem of power consumption as the power of computers increases dramatically. The process by which a complex program suite like GAMESS is maintained and developed is considered. Future developments are briefly summarized.

74 ATOMIC AND MOLECULAR PHYSICS↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self‐Assembled NiO Nanocrystal Arrays as Memristive Elements

Abstract Memristive switching, a nonlinear current–voltage ( I – V ) characteristic, has seen a tremendous surge in interest as an approach to achieve implementation of synaptic functions. The memristive switching behavior of self‐assembled NiO nanocrystals is investigated via scanning probe microscopy, based on first‐order reversal curve current–voltage spectroscopy. Synaptic switching is clearly observed as a direct consequence of filament growth (i.e., gradually increased conductance) in the nanocrystals. A spatial dependency of the conduction in the nanocrystals suggests that there is a localization of the switching filament. The current understanding of this localization ignores features related to local lateral variation current, which can generate an excessive local heat and temperature such as electrical dissipation. The observation of low electrical dissipation at the edge of the nanocrystals shows that less energy is wasted as heat such that the bias applied can be utilized more efficiently to assist the nucleation of the filament and thus reduces the power consumption. Electrical power dissipation is also found to scale with nanocrystal height and has spatial dependence within the nanocrystals. The combination of synaptic switching and high density of the nanocrystals demonstrate that it is feasible to exploit them to create a basic architecture for neuromorphic memory devices.

Kurnia, Fran↗

An automated and portable method for selecting an optimal GPU frequency

Power consumption poses a significant challenge in current and emerging graphics processing unit (GPU) enabled high-performance computing systems. In modern GPUs, dynamic voltage frequency scaling (DVFS) appears to be a reliable control to regulate power consumption and performance. However, the DVFS design space is large - hence, brute-force approaches are infeasible to select the optimal frequency. Furthermore, no single frequency can be universally optimal for applications with varying computational intensities. Thus, the application's complexity and the availability of a wide range of frequency settings are a challenge in selecting the optimal frequency configuration for a given GPU workload. To that end, this paper proposes a systematic approach that consists of three steps. The feature characterization study identifies the fine-grain GPU utilization metrics that influence the power consumption and execution time of a given workload. To understand the performance, power, and energy consumption behaviors of a workload across GPU's DVFS design space, we derived analytical power and performance models using the identified fine-grain features. Here, it is shown that the same set of GPU utilization metrics can estimate both the power consumption and execution time while being agnostic of changes to frequency and input sizes. Applying a power control with the single objective of reducing power may cause performance degradation, leading to more energy consumption. A multi-objective approach is proposed to select the optimal GPU DVFS configuration for a workload that reduces power consumption with negligible degradation in performance. The evaluation was conducted using SPEC ACCEL benchmarks and three real applications - NAMD LAMMPS, and LSTM on NVIDIA GV100, GA100, and AMD MI210 GPUs. On average, real applications showed 29.6% energy savings with a performance loss of 5.2% on GA100 and 22.6% energy savings with a performance loss of 4.7% on GV100. Moreover, the proposed models are portable to real applications, GPU architectures, and vendors, and require metric collection at only the default frequency rather than all supported DVFS configurations. Additionally, we conducted a comparison between our models and the GPU assembly instructions (PTX)-based static models. The results revealed a significant reduction in the average error rates, with a decrease from 19.7% to 3.1% for power models and from 29.4% to 5.2% for performance models.

97 MATHEMATICS AND COMPUTING↗

PowerMappeR: Power-Optimized Mapping of SNNs onto ReRAM Crossbars coupled via Packet-Switched NoCs

Many recent efforts in developing hardware-accelerated spiking neural networks (SNNs) are characterized by deep co-design between algorithms, architectures, and devices. Architectural advances overcome device constraints by coupling together many small resistive-RAM (ReRAM) crossbars via a network-on-chip (NoC) for neuromorphic component operation. Concurrently, improved SNN training methods increase accuracy and structural sparsity in networks despite growing problem sizes. Finally, compilers leverage these attributes to minimize area and inter-crossbar communication while mapping large SNNs to sophisticated architectures. However, for compiler-driven co-design to realize increasingly complex and profitable optimizations, a compile-time view of power consumption is critical. We present PowerMappeR to express and optimize over mapping-, architecture-, and device-specific power consumption information. By modeling the dynamic power of well-established components, we develop an integer linear programming (ILP)-based, encoding-agnostic, parametric power estimation model. Using this model, we demonstrate practical improvements in area and inter-crossbar communication by 0%–9.5% and 1.4%–5.1%, respectively. We also limit hotspot formation during optimization, achieving comparable or better results in targeted metrics with up to 96.4%–97.1% restriction of hotspot magnitude. Finally, we introduce profile-guided formulations to reduce worst-case and expected-case hotspot magnitude by 40.7%–69.5% and 40.6%–56.3%, respectively. Optimizing worst-case hotspot magnitude incidentally improves expected-case magnitude by 10.85%–33.45%. Reciprocally, optimizing expected-case magnitude incidentally improves worst-case magnitude by 4.33%–39.87%. Validation against hardware simulators confirms that PowerMappeR can decrease dynamic power consumption by 12.6%–27.3%.

Pohl, Devin [ORNL] (ORCID:0009000040149027)↗

Zeolite Membrane Reactor for Pre-Combustion Carbon Dioxide Capture (Final Scientific/Technical Report)

Water-gas shift (WGS) reaction followed by carbon dioxide (CO 2 ) separation is a critical step in the integrated gasification combined cycle (IGCC) process for fossil-fuel-fired electrical power generation with CO 2 capture. To intensify the IGCC process hydrogen-permselective zeolite membrane reactor offers promise to replace the conventional energy-intensive fixed-bed reactors and solvent-based CO 2 capture units. The objectives of this project were to develop a bench-scale zeolite membrane reactor (total membrane area: 932 cm 2 for a 21-tube membrane bundle) for the water-gas-shift reaction of raw syngas from an oxygen-blown coal-gasifier for H 2 production with simultaneous CO 2 separation at the capability of about 2 kilograms H 2 per day (equivalent to 2 kW IGCC power plant) and to demonstrate significant progress toward achieving overall performance goal of 90% CO 2 capture rate with 95% CO 2 purity at the cost of electricity 30% less than the baseline carbon capture approaches. This report summarizes results obtained in this project on scaling up the zeolite membrane reactor by a factor of 200 in membrane area, tests of the bench-scale zeolite membrane reactor for the water-gas-shift reaction at high temperature and high-pressure, and techno-economic analysis of the integration of the zeolite membrane reactor in IGCC power plant for the electrical generation with CO 2 capture. With effective pore modification by catalytic cracking deposition of MDES (methyldiethoxysilane), fabrication of MFI-type zeolite membranes was successfully scaled-up from a lab-scale disk type to bench-scale multiple-tube bundles on low-cost alumina supports. A Co-Mo based sour shift catalyst was evaluated and used in the zeolite membrane reactors for water-gas-shift reaction. The reaction kinetic and gas-permeation equations were developed and employed in mathematic models to guide/predict experiments/performance of zeolite membrane reactors for water-gas shift reaction. Multiple-tube zeolite membrane bundles and reactors were designed, fabricated and tested for gas separation and water-gas-shift reactions with real raw syngas from a coal-fired gasifier operated at high temperature and pressure. The zeolite membrane reactors demonstrated good long-term thermal and chemical stability and constant H 2 permeance (>300 GPU) together with a Knudsen selectivity (~4.7) for H 2 over CO 2 in the field test (cumulative time >28 hours) with high-sulfur coal-derived syngas. The zeolite-membrane-reactor integrated IGCC process was designed using the performance experimentally measured by the University of Cincinnati team with a single-tube zeolite membrane reactor that offers a CO conversion >98% with more than 90% of CO 2 and H 2 captured. With the above integrative approaches, a techno-economic analysis for a cost-benefit comparison was performed to uncover features that determine the power output, capital expenditure, operating expenditure, cost of electricity and cost of CO 2 capture in a 550-MW zeolite-membrane-reactor integrated IGCC process. The integration of the zeolite membrane reactor in IGCC could provide a significant reduction of 80% and 27% in the power consumption for Selexol™ Acid Gas Removal and CO 2 compression, respectively, which lowers the total auxiliary power consumption by 12.5%. However, the low pressure required at permeate stream for maintaining the driving force of hydrogen permeation through the zeolite membrane costs a huge power in permeate compressor, compensating the power consumption reduction achieved with the membrane reactor. Thus, for coal-fired IGCC for electricity generation with 90% CO 2 captured, the integration of the membrane reactor could provide a CO conversion ~99% and a significant drop in cost-of-electricity using zeolite membrane with H 2 permeance >600 GPU and the H 2 /CO 2 selectivity over 70.

01 COAL, LIGNITE, AND PEAT↗