Case Study: Integrate Nuclear Water Desalination - Regional Potable Water in Arizona

The present study analyzes the economic viability of an Integrated Energy System (IES) that couples a Reverse Osmosis (RO) water desalination facility with a Nuclear Power Plant (NPP). The case study is conducted in collaboration with Arizona Public Service (APS), the operating owner of the Palo Verde Generating Station (PVGS) NPP. Cooling water for the reactor steam cycle is derived from treated effluent from municipal wastewater treatment plants. APS has established a long-term water resources program to effect a substantial reduction in plant cooling costs through advanced treatment and cooling technologies, and through the use of alternative water sources to replace the increasingly expensive effluent. One possible option is to replace some amount of the annual volume of effluent with brackish groundwater from a local regional aquifer. Although much less expensive than the municipal effluent, the quantity of brackish groundwater that could be used for plant cooling is limited as a result of the salinity and its impact on plant operation. Consequently, supplemental treatment could be required such that a greater amount of brackish groundwater could be used to reduce the demand on effluent. A study was conducted in 2018 by Idaho National Laboratory (INL) to investigate the economics of a PVGS onsite RO desalination plant that would reduce the salinity of a municipal effluent and brackish water blend to an acceptable level. One of the main findings of that study was that the overall economics of water desalination can be greatly improved if, in addition to cooling water for PVGS, potable water could also be produced and sold for profit. In fact, the study concluded that only producing cooling water for PVGS via RO desalination is not economically viable. The present report investigates the economic impact of a large, regional RO desalination plant that could provide potable water for the region, considering the conclusions from the 2018 scoping study. The study looks in particular at the water-market situation for the developing municipalities in the west valley of Phoenix. In addition to providing potable water for the municipalities, the existing infrastructure that conveys effluent to the Palo Verde plant and onsite water treatment facilities could be used to manage the RO concentrate. The processed concentrate could lead to a cost reduction in plant cooling by replacing some amount of effluent. The analysis reported here considers two cases (for various scenarios). First, the Base Case considers that neither the regional nor the onsite RO is built. The 2018 INL study showed that some brackish water can be blended with the municipal effluent water without having to build the onsite RO. That correspond to the maximum economically profitable option. The Base Case is where APS pumps the maximum volume of less-expensive brackish water (limited by water chemistry in the circulating water system), i.e. the case for which cooling water acquisition and treatment cost are lowest (without RO). Second, the proposed RO Case includes two RO plants, one onsite at PVGS and another larger, regional RO plant close to the brackish water wells. The regional RO produces potable water that is sold to the regional municipalities, while the PVGS onsite RO treats (part of) the regional ROs' concentrate and brackish water blend. The desalinated water from the PVGS RO is used in the circulating water system at PVGS. The analysis evaluates the difference in economics, using the Net Present Value (NPV) and Internal Rate of Return (IRR), between the cases. By comparing the two cases, in addition to evaluating the economics of the regional RO, we can also assess the impact of the regional RO on PVGS operational costs and, consequently, APS economics. The study shows that there exist combinations of regional RO and PVGS RO sizes for which the total blowdown and water chemistry limits at PVGS (including regional RO concentrate treatment at PVGS) are satisfied. However, such combinations only exist if no additional brackish water is directly mixed in the tertiary water system at PVGS. This leads to higher Levelized Costs of Potable Water (LCOPW) compared to cases where additional brackish water is injected (but violate the physical constraints). Additional studies are suggested to investigate the benefit of additional brackish water injection (lowers cooling water cost) versus the cost of lifting the physical constraints, e.g. building additional evaporation ponds. Staying in the case of no additional brackish water and satisfying the existing PVGS constraints, the lowest LCOPW (~0.5 $/m 3 ) can be achieved with a size of the regional RO of ~1.4e7 m 3 /yr (11000 AF/yr) capacity, which leads to ~8.63e6 m 3 /yr (7000 AF/yr) of potable water while no onsite RO at PVGS is built. Considering the vii residential water demand model developed for the Phoenix west valley, the NPV for this regional RO would be ~$100 million if all municipalities in the vicinity participate from the beginning of the project.

97 MATHEMATICS AND COMPUTING↗

Bounding the marginal cost of producing potable water including the use of seawater desalinization as a backstop potable water production technology

The analysis presented in this technical report should allow for the creation of high, medium, and low cost potable water prices for GCAM. Seawater reverse osmosis (SWRO) based desalinization should act as a backstop for the cost of producing potable water (i.e., the literature seems clear that SWRO should establish an upper bound for the plant gate cost of producing potable water). Transporting water over significant distances and having to lift water to higher elevations to reach end-users can also have a significant impact on the cost of producing water. The three potable fresh water scenarios describe in this technical report are: low cost water scenario ($0.10/m 3 ); medium water cost scenario ($1.00/m 3 ); and high water cost scenario ($2.50/m 3 ).

costs↗

Comparative life cycle assessment of remote potable water supply for the Department of Defense

The Department of Defense (DOD) and other agencies, including relief organizations, require potable water for remote missions around the globe. As part of recent initiative by the U.S. Federal government through Executive Order 14057, the DOD has been instructed to investigate the sustainability of operations and practices within the context of climate change. One such practice that needs to be addressed is the procurement of potable water, an essential requirement of any remote mission or location. Currently, there are three primary means of procuring potable water at remote locations: bottled water, on-site purification, or tie-in to existing, local infrastructure. The first two operations are often considered the most secure options, but have sustainability concerns. The purpose of this study is to compare the environmental impacts of bottled water procurement versus on-site treatment via a mobile Reverse Osmosis Water Purification Unit (ROWPU), which uses multiple levels of filtration to make potable water from a local source. A cradle-to-gate assessment was developed for both systems to compare different options for potable water supply. An in person inventory was paired with data taken from the Ecoinvent 3.8 database to directly compare the two systems. The two systems are compared on a 5-year timeline to analyze the environmental impact of repeated bottled water transport versus diesel generator-fueled on-site treatment. Across all impact categories, the results indicate that high energy costs of the reverse osmosis process have significantly less impact on the environment than the repetitive transport and procurement of bottled water. The results of the study have important implications for advancing sustainable operations for remote communities or temporary settlements.

54 ENVIRONMENTAL SCIENCES↗

Operation and Maintenance Manual for the Remote-Handled Low-Level Waste Facility Potable Water System (PWS #6120030)

The document is an Operations and Maintenance Manual for the Remote Handled Low Level Waste Disposal Facility (RHLLW) potable water system. This document is required by the State of Idaho Department of Environmental Quality. The document defines the system, components, interfaces with ATR, operations of the system, contains operating procedures and log sheets, component manufacturer sheets showing compliance with regulations and also contains signed Preventive Maintenance Justification forms for applicable components of the potable water system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative PLC Design for Optimized Potable Water Managment

My project here at Idaho National Laboratory (INL) was to work on Potable Water PLC Design (Programmable Logic Controllers). I was tasked in making a new panel design for the PLC system that will be moved from TRA BLDG 696 to TRA BLDG 608. This design needed to be updated since the old PLC system being about 20 years old. The manufacturer of the MicroLogix 1200 life expectancy showed it to be 10-20 years, and the system was discontinued in 2017. The new system we implemented was called CompactLogix Controller 5380, along with a new 24 VDC/10 Amp Power Supply. I made a design using Microsoft Visio, with the new material. But we needed to add it onto an Aluminum Panel that the system will be mounted onto, we need Unistrut’s for the aluminum panel to be mounted to. Some of the material we will still be using, like the R1 Alarm Relay, will be moving with the PLC system. The rest of the material will be new supplies that need to be updated systems, which the site is waiting for to complete the PLC system.

47 - OTHER INSTRUMENTATION↗

Sensing of contaminants in potable water using TiO{sub 2} functional film

The piezoelectric based quartz crystal microbalance is employed for sensing contaminants in potable water. A spin coated thin layer of TiO{sub 2} nanoparticles was formed at the sensing area of a 5 MHz AT-cut quartz wafer. The thin film of TiO{sub 2} nanoparticles forms a mesoporous functional layer for the trapping of water borne contaminants. The morphology of the thin film of TiO{sub 2} nanoparticles was studied using field emission scanning electron microscope (FESEM). The surface morphology of the TiO{sub 2} nanoparticles reveals the mesoporous structures indicating large number of defects and porous sites. Such film was employed for the detection of water borne contaminants by detecting the piezoelectric response from a quartz crystal microbalance. We found the film to be very sensitive to the contaminants. The minimum detection limit was found to be 330 ppb. The effect of surface recharging was also studied by altering the physical conditions so that the film can be used for repetitive usage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Centralized AI Lakehouse Framework for Brain Tumor MRI Classification and Segmentation, University KPI Forecasting, and Water Potability Prediction

In many university and healthcare projects, models are built for very different data types such as tables, institutional time series, and medical images, but they are deployed as separate applications. In this work, that separation made testing and maintenance difficult because each module had its own pipeline and runtime requirements. This paper presents an integrated AI lakehouse-style implementation that runs three model pipelines inside one containerized backend. For medical imaging, we used MRI datasets from IEEE DataPort: a four-class classification set with 7012 images (5708 train/1304 test) and a segmentation set with 3063 image–mask pairs. The classification model (ResNet50 transfer learning) is evaluated using a proper train–validation–test protocol across multiple splits (80/10/10, 70/10/20, 60/10/30, and 10/30/60), achieving a test accuracy of 99.00% under the standard 80/10/10 split. Additionally, a patient-level evaluation is conducted using an external glioma dataset to provide a more realistic assessment without data leakage. The segmentation model (DeepLabV3-ResNet50) achieved 83.09% validation mIoU and 88.79% Dice score. For university KPI forecasting, we used annual IPEDS and NSF HERD data from 2010 to 2023 for three universities (BSU, EOU, and UAB). To examine the effect of preprocessing on forecasting performance, two case studies are conducted. In the first case, linear interpolation is applied to generate semester-level data. In the second case, the original annual data is used directly without interpolation. Random Forest regression and ARIMA models are evaluated using MAE, RMSE, MAPE, and R 2 . The results showed that interpolation improved apparent forecasting performance due to smoothing, while evaluation on the original annual data provided a more realistic assessment of model behavior. To further validate the framework on a larger dataset, an additional case study is conducted using a student dropout dataset. For water potability, we trained and compared multiple tabular classifiers on a large dataset (1,048,575 samples). A Random Forest model (100 trees, max depth 10) achieved 85.86% test accuracy and high recall for unsafe samples (0.8447). All modules are served via FastAPI and deployed together using Docker, with workflow automation routing requests to the correct endpoint. System-level benchmarking indicates that the backend maintains stable throughput and latency under concurrent requests.

97 MATHEMATICS AND COMPUTING↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

U.S. Indirect and Direct Potable Water Reuse Systems (2020)

Collection of proposed, operating, demonstration, and pilot study potable reuse systems across the U.S. as of 2020. Information includes project name, location, augmentation type, capacity, year operational, treatment train, and source water type. References are included in this submission. As potable reuse facilities undergo expansions or upgrades, treatment trains and capacities are subject to change. Operational status may also change. Treatment trains listed are reported to the detail that the source provides. Type and doses of chemical post-treatment or chlorination is often not specified. Please see README section in spreadsheet for definitions of acronyms used.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

US Potable Water Reuse System Costs

This submission contains a set of U.S.-specific potable reuse capital and operations and maintenance (O&M) cost data ($2020) found in published presentations and reports from engineering consulting firms, utility and water agency press releases or websites, and literature. For any unbuilt facilities, the reported costs found in technical documents are mostly engineer estimates and may be subject to change as construction proceeds. This data set contains a mix of both facility specific and total capital costs, which include conveyance infrastructure. Note that this dataset does not include detailed cost breakdowns for each of the facilities. This submission also contains the sources used to build this dataset in pdf format.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Polyhedral Relaxations for Optimal Pump Scheduling of Potable Water Distribution Networks

The classic pump scheduling or optimal water flow (OWF) problem for water distribution networks (WDNs) minimizes the cost of power consumption for a given WDN over a fixed time horizon. In its exact form, the OWF is a computationally challenging mixed-integer nonlinear program (MINLP). It is complicated by nonlinear equality constraints that model network physics, discrete variables that model operational controls, and intertemporal constraints that model changes to storage devices. To address the computational challenges of the OWF, this paper develops tight polyhedral relaxations of the original MINLP, derives novel valid inequalities (or cuts) using duality theory, and implements novel optimization-based bound tightening and cut generation procedures. The efficacy of each new method is rigorously evaluated by measuring empirical improvements in OWF primal and dual bounds over 45 literature instances. The evaluation suggests that our relaxation improvements, model strengthening techniques, and a thoughtfully selected polyhedral relaxation partitioning scheme can substantially improve OWF primal and dual bounds, especially when compared with similar relaxation-based techniques that do not leverage these new methods.

bound tightening↗

Comparison of two culture methods for the enumeration of Legionella pneumophila from potable water samples

Legionella infections have steadily increased in the United States over the last 20 years, and most of these infections have been attributed to contaminated water. The gold standard for confirmation of Legionella presence in water is culturing with Buffered Charcoal Yeast Extract (BCYE) agar. Following many modifications, this method is still time-consuming, expensive, and can take longer than 10 days for full confirmation. The Legiolert is a newer and simpler culture product that is claimed to be able to quantify Legionella pneumophila in 7 days with high sensitivity and specificity and does not need further confirmation for the presence of L. pneumophila. This study compared the culturability of L. pneumophila occurring in a simulated home plumbing system using both Legiolert and BCYE agar methods. Out of 185 water samples, Legiolert and BCYE method detected L. pneumophila in 83 and 85% of the samples, respectively. The two methods were determined to be statistically equivalent for culturability of L. pneumophila, though the detected levels by Legiolert were slightly higher than the BCYE method. The molecular confirmation of positive (n = 254) and negative wells (n = 82) with Legiolert also showed a high specificity of 96.5% (i.e., 3.5% false positives (9/254) and 0% false negatives (0/82)).

Boczek, Laura A.↗

Metering Plan: Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings [Slides]

This Plan presents progress toward the metering goals shared by all national laboratories and discusses PNNL's contemporary approach to the installation of new meters. In addition, the Plan discusses the data analysis techniques with which PNNL is working to mature using endless data streams made available as a result of increased meter deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Potable Water System Operations Plan

The existing Lawrence Livermore National Laboratory (LLNL) Site 300 drinking water system operation schematic is shown in Figures 1 and 2 below. The sources of water are from two Site 300 wells (Well #18 and Well #20) and San Francisco Public Utilities Commission (SFPUC) Hetch-Hetchy water through the Thomas shaft pumping station. Currently, Well #20 with 300 gallons per minute (gpm) pump capacity is the primary source of well water used during the months of September through July, while Well #18 with 225 gpm pump capacity is the source of well water for the month of August. The well water is chlorinated using sodium hypochlorite to provide required residual chlorine throughout Site 300. Well water chlorination is covered in the Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Chlorination Plan (“the Chlorination Plan”; LLNL-TR-642903; current version dated August 2013). The third source of water is the SFPUC Hetch-Hetchy Water System through the Thomas shaft facility with a 150 gpm pump capacity. At the Thomas shaft station the pumped water is treated through SFPUC-owned and operated ultraviolet (UV) reactor disinfection units on its way to Site 300. The Thomas Shaft Hetch- Hetchy water line is connected to the Site 300 water system through the line common to Well pumps #18 and #20 at valve box #1.

54 ENVIRONMENTAL SCIENCES↗