Studies Of Positive-Position-Feedback Control

Report discusses theoretical and experimental studies of positive-position-feedback control for suppressing vibrations in large flexible structures. Positive-position-feedback control involves placement of actuators and sensors on structure; control voltages applied to actuators in response to outputs of sensors processed via compensator algorithm. Experiments demonstrate feasibility of suppressing vibrations by positive position feedback, and spillover of vibrational energy into uncontrolled modes has stabilizing effect if control gain sufficiently small.

Fanson, James L.↗

Active control of a flexible structure using a modal positive position feedback controller

The feasibility of a new Modal Positive Position Feedback (MPPF) strategy in controlling the vibration of a complex flexible structure using a single piezo-electric active structural member is demonstrated. The control strategy generates its control forces by manipulating only the modal position signals of the structure to provide a damping action to undamped modes. This is in contrast to conventional modal controllers that rely in their operation on negative feedback of both the modal position and velocity. The proposed strategy is very simple to design and implement as it designs the controller at the uncoupled modal level and utilizes simple first order filters to achieve the Positive Position Feedback effect. The performance of the new strategy is enhanced by augmenting it with a time sharing strategy to share a small number of actuators between larger number of modes. The effectiveness of the new strategy is validated experimentally on a flexible box-type structure that has four bays and its first two bending modes are 2.015 and 6.535 Hz respectively. A single piezo-electric actuator is utilized as an active structural member to control several transverse bending modes of the structure. The performance of the active control system is determined in the time and the frequency domains. The results are compared with those obtained when using the Independent Modal Space Control (IMSC) of Meirovitch. The experimental results suggest the potential of the proposed strategy as a viable means for controlling the vibration of large flexible structures in real time.

Poh, S.↗

Active control of a flexible structure using a modal positive position feedback controller

The feasibility of a new Modal Positive Position Feedback (MPPF) strategy in controlling the vibration of a complex flexible structure using a single piezo-electric active structural member is demonstrated. The control strategy generates its control forces by manipulating only the modal position signals of the structure to provide a damping action to undamped modes. This is in contrast to conventional modal controllers that rely in their operation on negative feedback of both the modal position and velocity. The proposed strategy is very simple to design and implement as it designs the controller at the uncoupled modal level and utilizes simple first order filters to achieve the Positive Position Feedback effect. The performance of the new strategy is enhanced by augmenting it with a time sharing strategy to share a small number of actuators between larger number of modes. The effectiveness of the new strategy is validated experimentally on a flexible box-type structure that has four bays and its first two bending modes are 2.015 and 6.535 Hz, respectively. A single piezo-electric actuator is utilized as an active structural member to control several transverse bending modes of the structure. The performance of the active control system is determined in the time and the frequency domains. The results are compared with those obtained when using the Independent Modal Space Control (IMSC) of Meirovitch. The experimental results suggest the potential of the proposed strategy as a viable means for controlling the vibration of large flexible structures in real time.

Poh, S.↗

Anoxia begets anoxia: A positive feedback to the deoxygenation of temperate lakes

Abstract Declining oxygen concentrations in the deep waters of lakes worldwide pose a pressing environmental and societal challenge. Existing theory suggests that low deep‐water dissolved oxygen (DO) concentrations could trigger a positive feedback through which anoxia (i.e., very low DO) during a given summer begets increasingly severe occurrences of anoxia in following summers. Specifically, anoxic conditions can promote nutrient release from sediments, thereby stimulating phytoplankton growth, and subsequent phytoplankton decomposition can fuel heterotrophic respiration, resulting in increased spatial extent and duration of anoxia. However, while the individual relationships in this feedback are well established, to our knowledge, there has not been a systematic analysis within or across lakes that simultaneously demonstrates all of the mechanisms necessary to produce a positive feedback that reinforces anoxia. Here, we compiled data from 656 widespread temperate lakes and reservoirs to analyze the proposed anoxia begets anoxia feedback. Lakes in the dataset span a broad range of surface area (1–126,909 ha), maximum depth (6–370 m), and morphometry, with a median time‐series duration of 30 years at each lake. Using linear mixed models, we found support for each of the positive feedback relationships between anoxia, phosphorus concentrations, chlorophyll a concentrations, and oxygen demand across the 656‐lake dataset. Likewise, we found further support for these relationships by analyzing time‐series data from individual lakes. Our results indicate that the strength of these feedback relationships may vary with lake‐specific characteristics: For example, we found that surface phosphorus concentrations were more positively associated with chlorophyll a in high‐phosphorus lakes, and oxygen demand had a stronger influence on the extent of anoxia in deep lakes. Taken together, these results support the existence of a positive feedback that could magnify the effects of climate change and other anthropogenic pressures driving the development of anoxia in lakes around the world.

54 ENVIRONMENTAL SCIENCES↗

Positive position feedback control for large space structures

A new technique for vibration suppression in large space structures is investigated in laboratory experiments on a thin cantilever beam. This technique, called Positive Position Feedback, makes use of generalized displacement measurements to accomplish vibration suppression. Several features of Positive Position Feedback make it attractive for the large space structure control environment: The realization of the controller is simple and straightforward. Global stability conditions can be derived which are independent of the dynamical characteristics of the structure being controlled, i.e., all spillover is stabilizing. The method cannot be destabilized by finite actuator dynamics, and the technique is amenable to a strain-based sensing approach. The experiments control the first six bending modes of a cantilever beam, and make use of piezoelectric materials for actuators and sensors, simulating a piezoelectric active-member. The modal damping ratios are increased by factors ranging from 2 to 130.

Fanson, J. L.↗

Independent modal space control with positive position feedback

An independent modal space control (IMSC) algorithm is presented, whose modal control forces are generated from a positive position feedback (PPF) strategy. The proposed algorithm combines the attributes of both the IMSC and the PPF, and maintains the simplicity of the IMSC as it designs the controller of a complex structure at the uncoupled modal level. The effectiveness of the algorithm in damping out the vibration of flexible structures is validated experimentally. A simple cantilevered beam is employed as an example of a flexible structure whose multimodes of vibration are controlled by a single actuator. Performance of the active control system is determined in the frequency and the time domains. The experimental results indicate the potential of the proposed methodology as a viable method for controlling the vibration of large flexible structures.

Baz, A.↗

Pore-Scale Study on the Positive Feedback Between Stress and Porosity Caused by Pressure Solution in Porous Media

Pressure solution is an important process in the evolution of sedimentary rocks, which provide storage space for most of our petroleum resources. It directly influences the generation, migration, and storage of petroleum fluids in subsurface sedimentary rocks. Here, in this paper, we develop a pore-scale, mechanochemical model to demonstrate a possible positive feedback between the local porosity and pore surface stress, in which a higher local porosity causes a higher local pore surface stress, thus enhancing pressure solution and consequently further increasing the local porosity. Pore surface stress represents stress on a solid grain adjacent to a pore. Specifically, the pore-scale, mechanochemical model directly simulates the stress distribution over solid and pore surfaces using a finite element model. The dissolution of solids at the solid-pore interfaces under a far-from-equilibrium condition is simulated using a first-order kinetics model that accounts for the local stress distribution. The updated pore geometry, caused by pore surface dissolution, is then used in the stress simulation in the next numerical iteration. Two types of porous media, the Oriskany sandstone and an artificial porous medium with spherical pores, were tested in the mechanochemical simulation. The positive stress-porosity feedback during pressure solution was observed in both samples. In addition, the model quantitatively illustrated the distribution of local mineral dissolution rates on all pore surfaces, as well as its relation to the effective mineral dissolution rate of the entire sample. Based on the comparison between the two porous media, the local mineral dissolution was regulated by pore space distribution, geometry, and coalescence during pressure solution. This work is the first that uses direct, pore-scale numerical simulation to demonstrate the positive stress-porosity feedback during pressure solution, which has the potential to advance the understanding of the mechanical-chemical (MC) coupling in many geological processes that are relevant to subsurface energy systems, such as the recovery of petroleum hydrocarbons and geothermal energy.

CT scanning↗

Vacuum ultraviolet light source utilizing rare gas scintillation amplification sustained by photon positive feedback

A source of light in the vacuum ultraviolet (VUV) spectral region includes a reflective UV-sensitive photocathode supported in spaced parallel relationship with a mesh electrode within a rare gas at low pressure. A high positive potential applied to the mesh electrode creates an electric field which causes drifting of free electrons occurring between the electrodes and producing continuous VUV light output by electric field-driven scintillation amplification sustained by positive photon feedback mediated by photoemission from the photocathode. In one embodiment the lamp emits a narrow-band continuum peaked at 175 nm.

Aprile, Elena↗

Positive-feedback photometric drift in the PDS

Digitizing flatfield images produces conditions in the Photometric Data System PDS which cause the measured density to drift by as much as .1 DN during a 10 minute interval. The drift occurs when the PDS, set up in equilibrium at fog level, subsequently scans a reasonably dense region for periods of longer than a few minutes. The drift is manifested primarily as a positive shift in density that is approximately the same for all densities. If the fog level is assumed to be in fact constant and is monitored during scans of flat fields, the PDS drift may be removed by subtracting the difference between the observed fog level and its assumed constant value for each pixel. This function is then smoothed and subtracted, as a function of scan line, from the measured density. The fog level is then adjusted to a standard value by adding a constant. The result is a flattened scan with PDS drift removed to the accuracy within which the fog level drift matches the drift at other levels.

Cornett, R. H.↗

Response to "The Iris Hypothesis: A Negative or Positive Cloud Feedback?"

Based on radiance measurements of Japan's Geostationary Meteorological Satellite, Lindzen et al. found that the high-level cloud cover averaged over the tropical western Pacific decreases with increasing sea surface temperature. They further found that the response of high-level clouds to the sea surface temperature had an effect of reducing the magnitude of climate change, which is referred as a negative climate feedback. Lin et al. reassessed the results found by Lindzen et al. by analyzing the radiation and clouds derived from the Tropical Rainfall Measuring Mission Clouds and the Earth's Radiant Energy System measurements. They found a weak positive feedback between high-level clouds and the surface temperature. We have found that the approach taken by Lin et al. to estimating the albedo and the outgoing longwave radiation is incorrect and that the inferred climate sensitivity is unreliable.

Chou, Ming-Dah↗

Linear analysis of a force reflective teleoperator

Complex force reflective teleoperation systems are often very difficult to analyze due to the large number of components and control loops involved. One mode of a force reflective teleoperator is described. An analysis of the performance of the system based on a linear analysis of the general full order model is presented. Reduced order models are derived and correlated with the full order models. Basic effects of force feedback and position feedback are examined and the effects of time delays between the master and slave are studied. The results show that with symmetrical position-position control of teleoperators, a basic trade off must be made between the intersystem stiffness of the teleoperator, and the impedance felt by the operator in free space.

Biggers, Klaus B.↗

Unstable Air-Sea Interaction in the Extratropical North Atlantic

The possibility of coupled modes in the extratropical North Atlantic has fascinated the climate community since 1960's. A significant aspect of such modes is an unstable air-sea interaction, also called positive feedback, where disturbances between the atmosphere and ocean grow unbound. If a delayed response exists before the negative feedback takes effect, an oscillatory behaviour will develop. Here we explore the relationship between heat flux (positive upward) and sea surface temperature (SST). Positive feedback is characterized by a cross-correlation between the two where correlation maintains a negative sign whether SST or heat flux leads. We use model results and observations to argue that in the North Atlantic there exist regions with positive feedback. The two main locations coincide with the well-known north-south SST dipole where anomalies of opposite sign occupy areas east of Florida and north-east of Newfoundland. We show that oceanic dynamics, wave propagation and advection, give rise to oceanic anomalies in these regions. Subsequently these anomalies are amplified by atmosphere- ocean interaction: thus a positive feedback.

Hakkinen, Sirpa↗

Fail-fixed servovalve with positive fluid feedback

The servovalve includes a primary jet of fluid. A variable control signal is adapted to vary the angular position of the primary jet from its maximum recovery position. A first fluid path is adapted to supply fluid to a servopiston at a variable pressure determined at least in part by the control signal. A second fluid path is adapted to receive a predetermined portion of the primary jet fluid when the control signal reaches a predetermined value. The second fluid path terminates in the vicinity of the primary jet and is adapted to direct a secondary jet of fluid at the primary jet to deflect the primary jet toward the input orifice of the second fluid path. The resultant positive fluid feedback in the second fluid path causes the primary jet to latch in a first angular position relative to the maximum recovery position when the control signal reaches a predetermined value. The servovalve may further include a means to discharge the fluid and a means to block the first fluid path to the servopiston when the control signal falls below a second predetermined value. A method of operating a fail-fixed servovalve is also described.

Kast, Howard B.↗

Improved Electrohydraulic Linear Actuators

A product line of improved electrohydraulic linear actuators has been developed. These actuators are designed especially for use in actuating valves in rocket-engine test facilities. They are also adaptable to many industrial uses, such as steam turbines, process control valves, dampers, motion control, etc. The advantageous features of the improved electrohydraulic linear actuators are best described with respect to shortcomings of prior electrohydraulic linear actuators that the improved ones are intended to supplant. The flow of hydraulic fluid to the two ports of the actuator cylinder is controlled by a servo valve that is controlled by a signal from a servo amplifier that, in turn, receives an analog position-command signal (a current having a value between 4 and 20 mA) from a supervisory control system of the facility. As the position command changes, the servo valve shifts, causing a greater flow of hydraulic fluid to one side of the cylinder and thereby causing the actuator piston to move to extend or retract a piston rod from the actuator body. A linear variable differential transformer (LVDT) directly linked to the piston provides a position-feedback signal, which is compared with the position-command signal in the servo amplifier. When the position-feedback and position-command signals match, the servo valve moves to its null position, in which it holds the actuator piston at a steady position.

Hamtil, James↗

Fabrication and test of digital output interface devices for gas turbine electronic controls

A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.

Newirth, D. M.↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials

The use of aerodynamic pressure differentials to position a control surface is evaluated. The system is a differential pressure command loop, analogous to a position command loop, where the surface is commanded to move until a desired differential pressure across the surface is achieved. This type of control is more direct and accurate because it is the differential pressure which causes the control forces and moments. A frequency response test was performed in a low speed wind tunnel to measure the performance of the system. Both pressure and position feedback were tested. The pressure feedback performed as well as position feedback implying that the actuator, with a break frequency on the order of 10 Rad/sec, was the limiting component. Theoretical considerations indicate that aerodynamic lags will not appear below frequencies of 50 Rad/sec, or higher.

Levy, D. W.↗