At least 19 records

Towards deep computer vision for in-line defect detection in polymer electrolyte membrane fuel cell materials

Polymer Electrolyte Membrane (PEM) fuel cells are a promising source of alternative energy. However, their production is limited by a lack of well-established methods for quality control of their constituent materials like the membrane-electrode assembly during roll-to-roll manufacturing. One potential solution is the implementation of deep learning methods to detect unwanted defects through their detection in scanned images. Here we explore the detection of defects like scratches, pinholes, and scuffs in a sample dataset of PEM optical images using two deep learning algorithms: Patch Distribution Modeling (PaDiM) for unsupervised anomaly detection and Faster-RCNN for supervised object detection. Both methods achieve scores on performance metrics (ROC-AUC and PRO-AUC for PaDiM and AP for Faster-RCNN) that are comparable to their scores on benchmark datasets. These methods also have the potential to detect a wider range of defects compared to IR thermography and previous optical inspection methods. Overall, deep learning shows promise at detecting relevant defects of interest and has the potential to achieve real-time defect detection.

30 DIRECT ENERGY CONVERSION↗

The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

Mitigation and Diagnosis of Pin-Hole Formation in Polymer Electrolyte Membrane Fuel Cells

In this work, we implement a calendering technique to flatten stray fibers within the gas diffusion media, thereby mitigating pin-hole formation in the hot-pressed MEAs. We have investigated the influence of calendering on the long-term durability for several types of gas diffusion electrodes (GDEs) using a combined chemical and mechanical accelerated stress test (AST). The calendered MEAs demonstrate an average AST lifetime improvement of 77% relative to the as-fabricated MEAs.

AMR↗

Durability of PGM catalyst MEAs of polymer electrolyte membrane fuel cells for heavy-duty vehicles

Polymer electrolyte membrane fuel cells (PEMFCs) are promising power sources for heavy-duty vehicles (HDVs) owing to cleanliness and efficiency. However, the degradation of membrane electrode assemblies (MEAs) under HDV conditions remains a huge challenge. Here, this work investigated MEA durability under HDV conditions using a US Department of Energy standard accelerated stress test for 180,000 cycles (equivalent to 1 million miles of HDV operation). Effects of catalyst Pt content on MEA durability were examined using homemade 30% Pt/C (H-Pt/C) and commercial 46% Pt/C (C-Pt/C) catalysts. Both MEAs experienced H 2 /air and H 2 /O 2 performance loss over cycles. Analysis with scanning transmission electron microscopy, X-ray diffraction, inductively coupled plasma mass spectrometry, and mercury intrusion porosimetry revealed severe degradation of Pt nanoparticles (NPs), support structures, and the catalyst layer. Two degradation stages for NPs were proposed: Ostwald ripening dominated the initial 60,000 cycles, followed by combined Ostwald ripening and particle migration. Measurements with ion chromatography, high-frequency resistance, and oxygen-diffusion resistance revealed degradation of membrane and ionomer, respectively.

25 ENERGY STORAGE↗

Optimizing liquid free ionomer binders for high-temperature polymer electrolyte membrane fuel cells for heavy duty vehicles

This report documents tech transfer from Penn State to Ionomer Solutions LLC for high-temperature polymer electrolyte membrane fuel cells. High-temperature polymer electrolyte membrane (HT-PEM) fuel cells are enticing power plants for heavy-duty vehicle (HDV) transportation because their elevated temperature operation fosters greater heat rejection through larger temperature differentials. In 2021, over 6 million battery electric light duty vehicles (LDVs) were sold. Conversely, only 19,000 LDVs using fuel cell power trains were sold in 2021. Given the meteoric rise of battery-based powertrains for LDVs and its projected growth, stakeholders for fuel cell technology for transportation have shifted their focus towards HDVs rather than LDVs given fuel cells specific and volumetric energy density advantage over batteries when the vehicle is large, heavy, and/or needs to move large distances before refueling.

30 DIRECT ENERGY CONVERSION↗

High Temperature Polymer Electrolyte Membrane Fuel Cells with High Phosphoric Acid Retention

Phosphoric acid loss poses immense hurdles for the durability of high-temperature polymer electrolyte membrane fuel cells (HT-PEMFCs). Here we report quaternary ammonium-biphosphate ion-pair HT-PEMFCs that do not lose phosphoric acids under normal and accelerated stress conditions. Additionally, our energetics study explains the acid loss behavior of the conventional phosphoric acid-polybenzimidazole (PA-PBI) system by two mechanisms. If PA loss occurs via acid evaporation, the acid loss is constant over time. On the other hand, when water activity in the PA-PBI system is high, exponential decay of PA loss occurs via the water replacement mechanism. Combined 31 P NMR and computational studies show that the proposed ion-pair system has six times higher interaction energy, which allows for containing all PAs in the membrane electrode assemblies under a broad range of operating conditions. In addition, polar interactions between the phosphonic acid ionomer and phosphoric acid explain acid retention in the electrodes of the ion-pair HT-PEMFCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The impact of hot-press conditions on the durability of polymer electrolyte membrane fuel cells

The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.

08 HYDROGEN↗

Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes

Polymer electrolyte membranes that conduct hydroxide ions have potential use in fuel cells. A variety of polystyrene-based quaternary ammonium hydroxides have been reported as anion exchange fuel cell membranes. However, the hydrolytic stability and conductivity of the commercially available membranes are not adequate to meet the requirements of fuel cell applications. When compared with commercially available membranes, polystyrene-imidazolium alkaline membrane electrolytes are more stable and more highly conducting. At the time of this reporting, this has been the first such usage for imidazolium-based polymeric materials for fuel cells. Imidazolium salts are known to be electrochemically stable over wide potential ranges. By controlling the relative ratio of imidazolium groups in polystyrene-imidazolium salts, their physiochemical properties could be modulated. Alkaline anion exchange membranes based on polystyrene-imidazolium hydroxide materials have been developed. The first step was to synthesize the poly(styrene-co-(1-((4-vinyl)methyl)-3- methylimidazolium) chloride through a free-radical polymerization. Casting of this material followed by in situ treatment of the membranes with sodium hydroxide solutions provided the corresponding hydroxide salts. Various ratios of the monomers 4-chloromoethylvinylbenzine (CMVB) and vinylbenzine (VB) provided various compositions of the polymer. The preferred material, due to the relative ease of casting the film, and its relatively low hygroscopic nature, was a 2:1 ratio of CMVB to VB. Testing confirmed that at room temperature, the new membranes outperformed commercially available membranes by a large margin. With fuel cells now in use at NASA and in transportation, and with defense potential, any improvement to fuel cell efficiency is a significant development.

Narayan, Sri R.↗

Coaxial Nanowire Electrodes Enable Exceptional Fuel Cell Durability

Polymer-electrolyte-membrane fuel cells (PEMFCs) hold great promise for applications in clean energy conversion, but cost and durability continue to limit commercialization. This work presents a new class of catalyst/electrode architecture that does not rely on Pt particles or carbon supports, eliminating the primary degradation mechanisms in conventional electrodes, and thereby enabling transformative durability improvements. The coaxial nanowire electrode (CANE) architecture consists of an array of vertically aligned nanowires, each comprising an ionomer core encapsulated by a nanoscale Pt film. This unique design eliminates the triple-phase boundary and replaces it with two double-phase boundaries, increasing Pt utilization. It also eliminates the need for carbon support and ionomer binder, enabling improved durability and faster mass transport. Fuel cell membrane electrode assemblies based on CANEs demonstrate extraordinary durability in accelerated stress tests (ASTs), with only 2% and 5% loss in performance after 5000 support AST cycles and 30000 catalysts AST cycles, respectively. The high-power density and extremely high durability provided by CANEs can enable a paradigm shift from random electrodes based on unstable platinum nanoparticles dispersed on carbon to ordered electrodes based on durable Pt nanofilms, facilitating rapid deployment of fuel cells in transportation and other clean energy applications.

25 ENERGY STORAGE↗

Aqueous liquid feed organic fuel cell using solid polymer electrolyte membrane

A liquid organic fuel cell is provided which employs a solid electrolyte membrane. An organic fuel, such as a methanol/water mixture, is circulated past an anode of a cell while oxygen or air is circulated past a cathode of the cell. The cell solid electrolyte membrane is preferably fabricated from Nafion.TM.. Additionally, a method for improving the performance of carbon electrode structures for use in organic fuel cells is provided wherein a high surface-area carbon particle/Teflon.TM.-binder structure is immersed within a Nafion.TM./methanol bath to impregnate the electrode with Nafion.TM.. A method for fabricating an anode for use in a organic fuel cell is described wherein metal alloys are deposited onto the electrode in an electro-deposition solution containing perfluorooctanesulfonic acid. A fuel additive containing perfluorooctanesulfonic acid for use with fuel cells employing a sulfuric acid electrolyte is also disclosed. New organic fuels, namely, trimethoxymethane, dimethoxymethane, and trioxane are also described for use with either conventional or improved fuel cells.

Surampudi, Subbarao↗

Near-ambient solid polymer fuel cell

Fuel cells are extremely attractive for extraterrestrial and terrestrial applications because of their high energy conversion efficiency without noise or environmental pollution. Among the various fuel cell systems the advanced polymer electrolyte membrane fuel cells based on sulfonated fluoropolymers (e.g., Nafion) are particularly attractive because they are fairly rugged, solid state, quite conductive, of good chemical and thermal stability and show good oxygen reduction kinetics due to the low specific adsorption of the electrolyte on the platinum catalyst. The objective of this program is to develop a solid polymer fuel cell which can efficiently operate at near ambient temperatures without ancillary components for humidification and/or pressurization of the fuel or oxidant gases. During the Phase 1 effort we fabricated novel integral electrode-membrane structures where the dispersed platinum catalyst is precipitated within the Nafion ionomer. This resulted in electrode-membrane units without interfacial barriers permitting unhindered water diffusion from cathode to anode. The integral electrode-membrane structures were tested as fuel cells operating on H2 and O2 or air at 1 to 2 atm and 10 to 50 C without gas humidification. We demonstrated that cells with completely dry membranes could be self started at room temperature and subsequently operated on dry gas for extended time. Typical room temperature low pressure operation with unoptimized electrodes yielded 100 mA/cm(exp 2) at 0.5V and maximum currents over 300 mA/cm(exp 2) with low platinum loadings. Our results clearly demonstrate that operation of proton exchange membrane fuel cells at ambient conditions is feasible. Optimization of the electrode-membrane structure is necessary to assess the full performance potential but we expect significant gains in weight and volume power density for the system. The reduced complexity will make fuel cells also attractive for smaller and portable power supplies and as replacement for batteries.

Holleck, G. L.↗

Electrode ink deposition system for high-throughput polymer electrolyte fuel cell

Systems for creating electrodes for polymer electrolyte membrane fuel cells include an XY stage having a heated vacuum table physically coupled to the XY stage. The vacuum table has a working face with a plurality of channels formed therein to communicate vacuum pressure from a port coupled to a vacuum source to the channels. A sheet of perforated heat-conductive material has staggered holes configured to evenly distribute the vacuum pressure from the channels through the perforated sheet. A heat-conductive wire mesh is placed over the perforated sheet, and has openings smaller than the staggered holes such that a membrane material placed on the wire mesh is not deformed by the vacuum pressure. A nanopipette or micropipette coupled to a pump is configured to deposit electrode ink onto an exposed surface of the membrane material as the controller device causes the XY stage to move the vacuum table to control deposition of the electrode ink onto the surface of the membrane material.

Park, Jae Hyung↗

Machine learning for optimizing the manufacture and operation of intermediate temperature fuel cells

The project developed machine learning and artificial intelligence (ML/AI) methodologies for guiding and accelerating the materials design and processing of new high temperature proton conducing electrode ionomer binders and reinforced membranes for high-temperature proton exchange membrane fuel cell (HT-PEMFC; aka intermediate-temperature polymer electrolyte membrane fuel cells).

08 HYDROGEN↗

Synergistic effect of polyaniline on stabilizing Pt nanoparticles in PEMFCs†

The stability of Pt nanoparticles on a carbon support is crucial for the lifespan of polymer electrolyte membrane fuel cells as well as other electrocatalysis systems such as electrolyzers. Here we took the approach of utilizing the covalently grafted polyaniline on carbon to stabilize Pt nanoparticles by simultaneously alleviating the particle migration and mitigating the Ostwald ripening, which are two major mechanisms for loss of the catalyst stability. A comprehensive investigation of the stability and performance of Pt catalyst nanoparticles on these supports reveals that the polyaniline can shift the Pt L edge binding energy and the Pt 4f peak energy, leading to the increased redox potential of the Pt nanoparticles and making them more resistant to oxidation. Interestingly, the highest polyaniline density (50 wt%) does not show the best catalyst stability, rather, the second (33 wt%) demonstrates the best catalyst stability among these catalysts. Combining the XPS, XAS and fuel cell stability studies, we concluded that the locations of the Pt nanoparticles over the polyaniline layer on the carbon surface depend on the surface density of the polyaniline over the carbon surface. The Pt nanoparticles in the 50 wt% polyaniline catalyst are wrapped by the polyaniline polymer but do not sit directly on the carbon surface, while Pt nanoparticles in the 33 wt% polyaniline catalyst sit on the carbon surface and are densely surrounded by the polyaniline polymer. The results show that the mass activity loss is 12.5% while the ECSA (electrochemically active surface area) loss is 37.1% after 30k cycles of accelerating stress test for the 33 wt% polyaniline catalyst, far exceeding the DOE 2020 target for MEA (i.e., mass activity loss < 50%, and ECSA loss < 40%). Overall, the polyaniline has a synergistic effect on mitigating the surface migration and slowing down the Ostwald ripening to stabilize the Pt nanoparticles in fuel cells. The novel strategy to stabilize Pt nanoparticles using polyaniline opens a new pathway in the development of highly stable catalysts: relying on the functionalization group on the carbon support, instead of just focusing on the catalyst itself.

Li, Chenzhao↗

Low Crossover Polymer Electrolyte Membranes for Direct Methanol Fuel Cells

Direct Methanol Fuel Cells (DMFC's) using polymer electrolyte membranes are promising power sources for portable and vehicular applications. State of the art technology using Nafion(R) 117 membranes (Dupont) are limited by high methanol permeability and cost, resulting in reduced fuel cell efficiencies and impractical commercialization. Therefore, much research in the fuel cell field is focused on the preparation and testing of low crossover and cost efficient polymer electrolyte membranes. The University of Southern California in cooperation with the Jet Propulsion Laboratory is focused on development of such materials. Interpenetrating polymer networks are an effective method used to blend polymer systems without forming chemical links. They provide the ability to modify physical and chemical properties of polymers by optimizing blend compositions. We have developed a novel interpenetrating polymer network based on poly (vinyl - difluoride)/cross-linked polystyrenesulfonic acid polymer composites (PVDF PSSA). Sulfonation of polystyrene accounts for protonic conductivity while the non-polar, PVDF backbone provides structural integrity in addition to methanol rejection. Precursor materials were prepared and analyzed to characterize membrane crystallinity, stability and degree of interpenetration. USC JPL PVDF-PSSA membranes were also characterized to determine methanol permeability, protonic conductivity and sulfur distribution. Membranes were fabricated into membrane electrode assemblies (MEA) and tested for single cell performance. Tests include cell performance over a wide range of temperatures (20 C - 90 C) and cathode conditions (ambient Air/O2). Methanol crossover values are measured in situ using an in-line CO2 analyzer.

Prakash, G. K. Surya↗