Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polar Fourier transform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Systematic Error Cancellation for the PIXIE Four-Port Interferometric Polarimeter

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the gravitational-wavesignature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwavebackground. Its optical system couples a polarizing Fourier transform spectrometer to the sky to measure thedifferential signal between orthogonal linear polarization states from two co-pointed beams on the sky. Thedouble differential nature of the four-port measurement mitigates beam-related systematic errors common to thetwo-port systems used in most CMB measurements. We describe the polarized beam patterns for PIXIE andassess the systematic error for measurements of CMB polarization.

Kogut, Alan↗

Systematic Error Cancellation for a Four-Port Interferometric Polarimeter

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the gravitational-wave signature of primordial inflation through its distinctive imprint on the linear polarization of thecosmic microwave background (CMB). Its optical system couples a polarizing Fourier transform spectrometerto the sky to measure the differential signal between orthogonal linear polarization states from two co-pointedbeams on the sky. The double differential nature of the four-port measurement mitigates beam-related systematic errors common to the two-port systems used in most CMB measurements. Systematic errors coupling unpolarized temperature gradients to a false polarized signal cancel to first order for any individual detector. Thiscommon-mode cancellation is performed optically, prior to detection, and does not depend on the instrumentcalibration. Systematic errors coupling temperature to polarization cancel to second order when comparing signals from independent detectors. We describe the polarized beam patterns for PIXIE and assess the systematicerror for measurements of CMB polarization.

Kogut, Alan J.↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. The differential design and multiple signal modulations spanning 11 orders of magnitude in time combine to reduce the instrumental signature and confusion from unpolarized sources to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 deg and sensitivity 0.2 uK per 1 deg square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r <10(exp -3) at 5 standard deviations. In addition, the rich PIXIE data will constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

Kogut, Alan J.↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. Multiple levels of symmetry and signal modulation combine to reduce the instrumental signature and confusion from unpolarized sources to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 deg and sensitivity 0.2 μK per 1 deg square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r less than 10(exp −3) at 5 standard deviations. In addition, PIXIE will measure the absolute frequency spectrum to constrain physical processes ranging from inflation to the nature of the first stars to the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture with an emphasis on the expected level of systematic error suppression.

Primordial Inflation Explorer is an Explorer-class↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to open new windows on the early universe through measurements of the polarization and absolute frequency spectrum of the cosmic microwave background. PIXIE will measure the gravitational-wave signature of primordial inflation through its distinctive imprint in linear polarization, and characterize the thermal history of the universe through precision measurements of distortions in the blackbody spectrum. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning over 7 octaves in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. Multiple levels of symmetry and signal modulation combine to reduce systematic errors to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 degrees and sensitivity 70 nK per 1degree square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10(exp. -3) at 5 standard deviations. The PIXIE mission complements anticipated ground-based polarization measurements such as CMBS4, providing a cosmic-variance-limited determination of the large-scale E-mode signal to measure the optical depth, constrain models of reionization, and provide a firm detection of the neutrino mass (the last unknown parameter in the Standard Model of particle physics). In addition, PIXIE will measure the absolute frequency spectrum to characterize deviations from a blackbody with sensitivity 3 orders of magnitude beyond the seminal COBE/FIRAS limits. The sky cannot be black at this level; the expected results will constrain physical processes ranging from inflation to the nature of the first stars and the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture required to measure the CMB to the limits imposed by astrophysical foregrounds.

Kogut, Alan↗

Vapor transport growth of organic solids in microgravity and unit gravity: some comparisons and results to date

Thin films of an organic nonlinear optical (NLO) material, N, N-dimethyl-p-(2,2-dicyanovinyl) aniline (DCVA), have been grown in space and on the ground by physical vapor transport in an effusive ampoule arrangement. The thin film growth technique developed on the ground is a direct result of information gleaned from experiments in microgravity. This paper covers the results of our experimental investigations for establishing "ideal" terrestrial conditions for deposition of a DCVA film. The active control during the deposition process was exercised by three deposition variables: the material source temperature, the background pressure external to the growth ampoule and the substrate temperature. Successful growth occurred when the difference in temperature between the source material and the copper substrate was 14 degrees C and the background nitrogen pressure was such that the transport was either diffusive or convective. A qualitative diffusion limited boundary was estimated to occur at a pressure of approximately 20 torr. We have probed the DCVA thin films with visible-near infrared reflection absorption spectroscopy, polarized Fourier transform infrared spectrometry, differential interference contrast optical microscopy, and stylus profilometry.

short duration↗

Fourier transform infrared studies of model polar stratospheric cloud surfaces - Growth and evaporation of ice and nitric acid/ice

Fourier-transform infrared surface studies are used to probe the microphysical properties of nitric acid trihydrate (NAT) and ice films representative of type I and II polar stratospheric clouds (PSC). Experiments indicate that, on initial exposure to 1.8 microtorr of HNO3, a layer of ice is quantitatively converted to NAT. However, conversion of ice to NAT does not proceed indefinitely, but rather the system reaches saturation. For longer exposures or higher HNO3 pressures, NAM becomes the dominant nitric acid containing species on the surface. Evaporation studies were performed to test the feasibility of a recent denitrification mechanism. The results indicate that ice coated with 0.20 micron of NAT evaporates at a temperature of about 4 C higher than uncoated ice.

Tolbert, Margaret A.↗

GPU-accelerated multitiered iterative phasing algorithm for fluctuation X-ray scattering

The multitiered iterative phasing (MTIP) algorithm is used to determine the biological structures of macromolecules from fluctuation scattering data. It is an iterative algorithm that reconstructs the electron density of the sample by matching the computed fluctuation X-ray scattering data to the external observations, and by simultaneously enforcing constraints in real and Fourier space. This paper presents the first ever MTIP algorithm acceleration efforts on contemporary graphics processing units (GPUs). The Compute Unified Device Architecture (CUDA) programming model is used to accelerate the MTIP algorithm on NVIDIA GPUs. The computational performance of the CUDA-based MTIP algorithm implementation outperforms the CPU-based version by an order of magnitude. Furthermore, the Heterogeneous-Compute Interface for Portability (HIP) runtime APIs are used to demonstrate portability by accelerating the MTIP algorithm across NVIDIA and AMD GPUs.

97 MATHEMATICS AND COMPUTING↗

Real-Time Alignment and Reorientation of Polymer Chains in Liquid Crystal Elastomers

Liquid crystal elastomers (LCEs) exhibit soft elasticity due to the alignment and reorientation of mesogens upon mechanical loading, which provides additional mechanisms to absorb and dissipate energy. This enhanced response makes LCEs potentially transformative materials for biomedical devices, tissue replacements, and protective equipment. However, there is a critical knowledge gap in understanding the highly rate-dependent dissipative behaviors of LCEs due to the lack of real-time characterization techniques that probe the microscale network structure and link it to the mechanical deformation of LCEs. In this work, we employ in situ optical measurements to evaluate the alignment and reorientation degree of mesogens in LCEs. The data are correlated to the quantitative physical analysis using polarized Fourier-transform infrared spectroscopy. The time scale of mesogen alignment is determined at different strain levels and loading rates. The mesogen reorientation kinetics is characterized to establish its relationship with the macroscale tensile strain, and compared to theoretical predictions. Overall, this work provides the first detailed study on the time-dependent evolution of mesogen alignment and reorientation in deformed LCEs. It also provides an effective and more accessible approach for other researchers to investigate the structural-property relationships of different types of polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of model polar stratospheric cloud films

Fourier transform infrared spectroscopy was used to examine the competitive growth of films representative of polar stratospheric clouds. These experiments show that either crystalline nitric acid trihydrate (beta-NAT) or amorphous films with H2O:HNO3 ratios close to 3:1 formed at temperatures 3-7 K warmer than the ice frost point under stratospheric pressure conditions. In addition, with higher HNO3 pressure, we observed nitric acid dihydrate (NAD) formation at temperatures warmer than ice formation. However, our experiments also show that NAD surfaces converted to beta-NAT upon exposure to stratospheric water pressures. Finally, we determined that the net uptake coefficient for HNO3 on beta-NAT is close to unity, whereas the net uptake coefficient for H2O is much less.

Middlebrook, Ann M.↗

High-resolution spectropolarimetry - A new atmospheric remote sensor

Polarimetry within a spectral line or band is proposed as a new atmospheric remote sensor, particularly for clouds and hazes. The limitations of conventional absorption/emission spectroscopy and photopolarimetry are discussed. The selective formation and behavior of intensity and polarization lines is analyzed under a variety of atmospheric and scattering conditions. The technique, limitations and advantages of Fourier Transform Spectroscopy are reviewed as a prelude to the proposed approach. Experimental results obtained at the telescope for the planet Venus are presented as evidence for the existence, behavior and effects of line polarization. Fourier Transform Spectropolarimetry provides means for separating the effects of scattering from those of absorption, probing the internal properties of clouds and hazes, and studying the detailed wavelength dependence of polarization with variable spectral resolutions from low to high.

Fymat, A. L.↗

Spectroscopic studies of model polar stratospheric cloud films

Fourier transform infrared (FTIR) spectroscopy has been used to study nitric-acid/ice films representative of type I polar stratospheric clouds (PSCs). These studies reveal that in addition to amorphous nitric acid/ice mixtures, there are three stable stoichiometric hydrates of nitric acid: nitric-acid monohydrate (NAM), dihydrate (NAD), and trihydrate (NAT). We also observe two distinct crystalline forms of the trihydrate, which we denote alpha- and beta-NAT. These two forms appear to differ in their concentration of crystalline defects, but not in their chemical composition. In addition to probing the composition of type I PSCs, we have also used FTIR spectroscopy to study the interaction of HCl with model PSC films. In this work we find that for HCl pressures in the range 10 exp -5 to 10 exp -7 Torr, HCl is taken up by ice at 155 K to form a thin layer of HCl.6H2O. At 193 K, the uptake of HCl by ice was consistent with less than or equal to monolayer coverage. Uptake of HCl by alpha and beta-NAT at 175 K was also consistent with less than or equal to monolayer coverage.

Tolbert, Margaret A.↗

Grid polarizers for infrared Fourier spectrometers

Infrared grid polarizers consisting of copper lines with a 3.6-micron grid constant on a 4-micron-thick Mylar polyester substrate have been prepared by the techniques of photolithography and sputter-etching. Their polarization properties have been measured and found to be suitable for use at infrared frequencies below 700/cm. The polarizers have been used to extend the useful frequency range of a Martin-Puplett polarizing interferometer designed for Fourier transform spectroscopy. The efficiency of the interferometer has been measured over a frequency range from 50 to 700/cm and compared to that of a conventional Michelson interferometer. The results are shown to be consistent with the measured properties of the polarizers. Methods are suggested for improving the efficiency of a Martin-Puplett interferometer which employs these polarizers.

Challener, W. A.↗

Infrared Optical Anisotropy in Quasi‐1D Hexagonal Chalcogenide BaTiSe 3

Polarimetric infrared (IR) detection bolsters IR thermography by leveraging the polarization of light. Optical anisotropy, i.e., birefringence and dichroism, can be leveraged to achieve polarimetric detection. Recently, giant optical anisotropy is discovered in quasi-1D narrow-bandgap hexagonal perovskite sulfides, A 1+x TiS 3 , specifically BaTiS 3 and Sr 9/8 TiS 3 . In these materials, the critical role of atomic-scale structure modulations in the unconventional electrical, optical, and thermal properties raises the broader question of the nature of other materials that belong to this family. To address this issue, for the first time, high-quality single crystals of a largely unexplored member of the A 1+x TiX 3 (X = S, Se) family, BaTiSe 3 are synthesized. Single-crystal X-ray diffraction determined the room-temperature structure with the P31c space group, which is a superstructure of the earlier reported P6 3 /mmc structure. The crystal structure of BaTiSe 3 features antiparallel c-axis displacements similar to but of lower symmetry than BaTiS 3 , verified by the polarization dependent Raman spectroscopy. Fourier transform infrared (FTIR) spectroscopy is used to characterize the optical anisotropy of BaTiSe 3 , whose refractive index along the ordinary (E ⊥ c) and extraordinary (E ‖ c) optical axes is quantitatively determined by combining ellipsometry studies with FTIR. With a giant birefringence Δn ∼ 0.9, BaTiSe 3 emerges as a new candidate for miniaturized birefringent optics for mid-wave infrared to long-wave infrared imaging.

optical anisotropy↗

Exploration of fibers produced from petroleum based-mesophase pitch and pet blends for carbon fiber production

Petroleum-derived mesophase pitch and polyethylene terephthalate (PET) were blended and melt-extruded to create precursor fibers. The raw blends, heat treated bulk materials, and fibers were all examined to determine compatibility between petroleum-derived mesophase pitch and PET. Thermal investigation of the raw blends showed the presence of both the pitch and PET in separate phases suggesting no interactions had occurred during mixing. Here, the heat-treated bulk material also showed multiple phases under polarized light while Fourier-transform infrared spectroscopy indicated that the two materials did not fully separate during extrusion. Elemental scans of the precursor fibers showed areas of high oxygen concentrations averaging 11.7% as compared to a 2% oxygen concentration across the majority of the cross-section. Tensile tests of the precursor fibers showed a decrease in average modulus as compared to pure pitch fibers; however, the depressed modulus of the blended fibers was found to be independent of the PET weight percentage. Fibers created from 5 wt.% PET had a strength value within 10% of pure pitch and a 200% increase in modulus and were therefore found to be the most promising for carbon fiber production. Pure pitch and the 5 wt.% PET fibers were stabilized and carbonized to 1000 °C. Both types of fibers were tensile tested to determine their strength and stiffness. Pure pitch carbon fibers maintained a higher strength while the carbon fibers produced from 5 wt.% PET possessed a stiffer modulus which can be attributed to their radial microstructure.

36 MATERIALS SCIENCE↗

Fourier transform infrared studies of the interaction of HCl with model polar stratospheric cloud films

Heterogeneous reactions involving hydrochloric acid adsorbed on the surfaces of polar stratospheric clouds (PSCs) are postulated to contribute to polar ozone loss. Using FTIR spectroscopy to probe the condensed phase, we have examined the interaction of HCl with ice and nitric acid trihydrate (NAT) films representative of types II and I PSCs, respectively. For HCl pressures in the range of 10 exp -7 to 10 exp -5 Torr, our FTIR studies show that a small amount of crystalline HCl-6H2O formed on or in ice at 155 K. However, for higher HCl pressures, we observed that the entire film of ice rapidly converted into an amorphous 4:1 H2O:HCl mixture. From HCl-uptake experiments with P(HCl) = 8 x 10 exp -7 Torr, we estimate roughly that the diffusion coefficient of HCl in ice is around 2 x 10 exp -12 sq cm/s at 158 K. For higher temperatures more closely approximating those found in the stratosphere, we were unable to detect bulk HCl uptake by ice. Indirect evidence suggests that HCl adsorption onto the surface of model PSC films inhibited the evaporation of both ice and NAT by 3-5 K.

Koehler, Birgit G.↗

A plane-polar approach for far-field construction from near-field measurements

The planar configuration with a probe scanning a polar geometry is discussed with reference to its usefulness in the determination of a far field from near-field measurements. The accuracy of the method is verified numerically, using the concept of probe compensation as a vector deconvolution. Advantages of the Jacobi-Bessel series over the fast Fourier transforms for the plane-polar geometry are demonstrated. Finally, the far-field pattern of the Viking high gain antenna is constructed from the plane-polar near-field measured data and compared with the previously measured far-field pattern.

Rahmat-Samii, Y.↗