Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel intensity noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A probability density function model describing height estimation uncertainty due to image pixel intensity noise in digital fringe projection measurements

Digital fringe projection is a surface-profiling technique used for highly accurate non-contact measurements. As with any measurement technique, a variety of sources degrade to the measurement accuracy of the method. Here, this paper presents an analytically-derived probability density function that explicitly models the surface height measurement error due to inevitable phase measurement error, and it includes the specific case of pixel noise inducing the phase measurement error that ultimately leads to the height estimation error. The accuracy of the model was validated through Monte-Carlo simulations of resultant height distributions subject to arbitrarily correlated pixel intensity noise and experimental digital fringe projection measurements where the pixel-by-pixel height uncertainty estimations were compared to the predictions of the derived model.

42 ENGINEERING↗

Effects of digital fringe projection operational parameters on detecting powder bed defects in additive manufacturing

Additive manufacturing is a technology transforming traditional production timelines. Specifically, metal additive manufacturing (MAM) has been increasingly adopted by a variety of industries, not only to prototype, but also to fulfill full production scale applications with much lower lead times. Like any maturing manufacturing technology, developments in verifying and validating processes are necessary to support continuous growth. Due to the complex nature of MAM, part quality and repeatability remain integral challenges that inhibit further adoption of MAM for critical component production. In this study, we present data taken from a developing in-process monitoring system designed to measure and detect powder bed defects (PBDs) in powder bed fusion MAM systems using surface height maps created with structured light illumination. We showcase the feasibility of the monitoring technique for in-process implementation by detecting streak PBDs with varying severities (height, width) created in a lab environment. We present results of powder bed measurements for varying experimental parameters of the structured light system such as illumination angle, illumination pattern, and number of illuminations. We also present an expression used to determine experimental height noise based on input parameters for PBD detection based on the instrument transfer function of the structured light monitoring system for arbitrary pixel intensity noise contributions. In conclusion, with the results of PBD detection across multiple experimental measurement parameters, we provide a best practices approach to in-process implementation of the monitoring system in powder bed fusion manufacturing.

36 MATERIALS SCIENCE↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

Sequence2Self: Self-supervised image sequence denoising of pixel-level spray breakup morphology

Optical imaging of fast and transient phenomena such as the turbulent breakup of liquid sprays exhibit low signal-to-noise ratios due to the limited illumination intensity relative to the short exposure time. Image denoising is required to facilitate physical studies over these data but is challenging due to the absence of clean ground-truths and the stringency of the denoising task (e.g., strong and complex noise, limited resolution, preserving physical fidelity), preventing supervised and existing un-/self-supervised deep learning methods. To this end, Sequence2Self (Seq2S) is proposed, an extension of Self2Self (S2S) to image sequences that leverages both the signal’s spatial and temporal correlation. Seq2S is demonstrated on time-resolved x-ray phase contrast imaging of liquid jet fuel sprays in a gas turbine combustor, which possesses all of challenges detailed above. Experiments are conducted across four fuels with different breakup morphology using various state-of-the-art methods. Overall, many of the methods failed and Seq2S was most successful: (1) Accurate spray structures were reconstructed with consistent evolution across frames void of artifacts. (2) The performance was robust, invariant to the hyperparameter choice. (3) Computational time is short and can be made eligible for real-time denoising. In particular, the images denoised by Seq2S showed spray droplet diameter distributions with near-zero Kullback–Leibler divergence (0.01 ± 0.01) to a cleaner reference, whereas the second best method yielded 0.06 ± 0.03. In conclusion, this suggests that Seq2S can be reliably used prior to subsequent quantitative spray analyses as it retains (if not, improves) the statistical physical properties of the data.

97 MATHEMATICS AND COMPUTING↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD- 2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2 x 2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. Here, the increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2 x 2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of 10 7 x-rays/s, and performs comparably with un-binned mode up to a photon flux of 10 8 x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.

47 OTHER INSTRUMENTATION↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, Laney [UC, Berkeley (main)] (ORCID:000900078↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, L. K. [UC, Berkeley (main)] (ORCID:000900078↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

FAST Drift Scan Survey for Ηι Intensity Mapping: I. Preliminary Data Analysis

This work presents the initial results of the drift-scan observation for the neutral hydrogen (Hi) intensity mapping survey with the Five-hundred-meter Aperture Spherical radio Telescope (FAST). The data analyzed in this work were collected in night observations from 2019 through 2021. The primary findings are based on 28 hr of drift-scan observation carried out over 7 nights in 2021, which covers 60 deg 2 sky area. Our main findings are, first, our calibration strategy can successfully correct both the temporal and bandpass gain variation over the 4 hr drift-scan observation. Second, the continuum maps of the surveyed region are made with frequency resolution of 28 kHz and pixel area of $_{2.95\,{\mathrm{arcmin}}^{2}}$. The pixel noise levels of the continuum maps are slightly higher than the forecast assuming $T$ sys = 20 K, which are 36.0 mK (for 10.0 s integration time) at the 1050–1150 MHz band, and 25.9 mK (for 16.7 s integration time) at the 1323–1450 MHz band, respectively. Third, the flux-weighted differential number count is consistent with the NRAO-VLA Sky Survey (NVSS) catalog down to the confusion limit ~7 mJy beam –1 . Finally, the continuum flux measurements of the sources are consistent with those found in the literature. The difference in the flux measurement of 81 isolated NVSS sources is about 6.3%. Our research offers a systematic analysis for the FAST Hi intensity mapping drift-scan survey and serves as a helpful resource for further cosmology and associated galaxies sciences with the FAST drift-scan survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Removal of correlated background in a high-order harmonic transient absorption spectra with principal component regression

We demonstrate a 40x mean noise power reduction (NPR) in core-to-valence extreme ultraviolet (XUV) femtosecond transient absorption spectroscopy with a high harmonic generation (HHG) light source. An adaptive iteratively reweighted principal component regression (airPCR) is used to analyze and suppress spectrally correlated HHG intensity fluctuations. The technique requires significantly less user input and leads to a higher mean NPR than a previously introduced edge-pixel PCR method that relies on the manual identification of signal-free spectral regions. Both techniques are applied in a time-resolved XUV absorption study of the 2 snp 1 P o ( n ≥ 2) autoionizing Rydberg states of helium, demonstrating sub-10 −3 optical density sensitivity.

Faccialà, Davide (ORCID:0000000250720394)↗

Combined thermographic phosphor and digital image correlation (TP + DIC) for simultaneous temperature and strain measurements

We report thermographic phosphors (TP) are combined with stereo digital image correlation (DIC) in a novel diagnostic, TP + DIC, to measure full-field surface strains and temperatures simultaneously. The TP + DIC method is presented, including corrections for nonlinear CMOS camera detectors and generation of pixel-wise calibration curves to relate the known temperature to the ratio of pixel intensities between two distinct wavelength bands. Additionally, DIC is employed not only for strain measurements but also for accurate image registration between the two cameras for the two-colour ratio method approach of phosphoric thermography. TP + DIC is applied to characterize the thermo-mechanical response of 304L stainless steel dog bones during tensile testing at different strain rates. The dog bones are patterned for DIC with Mg 3 F 2 GeO 4 :Mn (MFG) via aerosol deposition through a shadow mask. Temperatures up to 425°K (150°C) and strains up to 1.0 mm/mm are measured in the localized necking region, with conservative noise levels of 10°K and 0.01 mm/mm or less. Finally, TP + DIC is compared to the more established method of combining infrared (IR) thermography with DIC (IR + DIC), with results agreeing favourably. Three topics of continued research are identified, including cracking of the aerosol-deposited phosphor DIC features, incomplete illumination for pixels on the border of the phosphor features, and phosphor emission evolution as a function of applied substrate strain. This work demonstrates the combination of phosphor thermography and DIC and lays the foundation for further development of TP + DIC for testing in combined thermo-mechancial environments.

304L stainless steel↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗

CMB-PAInT: An inpainting tool for the cosmic microwave background

Abstract The presence of astrophysical emissions in microwave observations forces us to perform component separation to extract the Cosmic Microwave Background (CMB) signal. However, even in the most optimistic cases, there are still strongly contaminated regions, such as the Galactic plane or those with emission from extragalactic point sources, which require the use of a mask. Since many CMB analyses, especially the ones working in harmonic space, need the whole sky map, it is crucial to develop a reliable inpainting algorithm that replaces the values of the excluded pixels by others statistically compatible with the rest of the sky. This is especially important when working withQandUsky maps in order to obtainE- andB-mode maps which are free fromE-to-Bleakage. In this work we study a method based on Gaussian Constrained Realizations (GCR), that can deal with both intensity and polarization. Several tests have been performed to asses the validation of the method, including the study of the one-dimensional probability distribution function (1-PDF),E- andB-mode map reconstruction, and power spectra estimation. We have considered two scenarios for the input simulation: one case with only CMB signal and a second one including also Planck PR4 semi-realistic noise. Even if we are limited to low resolution maps, N side = 64 ifT,QandUare considered, we believe that this is a useful approach to be applied to future missions such as LiteBIRD, where the target are the largest scales.

Astronomy & Astrophysics↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Astrophysics & cosmology from line intensity mapping vs galaxy surveys

Line intensity mapping (LIM) proposes to efficiently observe distant faint galaxies and map the matter density field at high redshift. Building upon the formalism in a companion paper, we first highlight the degeneracies between cosmology and astrophysics in LIM. We discuss what can be constrained from measurements of the mean intensity and redshift-space power spectra. With a sufficient spectral resolution, the large-scale redshift-space distortions of the 2-halo term can be measured, helping to break the degeneracy between bias and mean intensity. With a higher spectral resolution, measuring the small-scale redshift-space distortions disentangles the 1-halo and shot noise terms. Additionally, cross-correlations with external galaxy catalogs or lensing surveys further break degeneracies. We derive requirements for experiments similar to SPHEREx, HETDEX, CDIM, COMAP and CONCERTO. We then revisit the question of the optimality of the LIM observables, compared to galaxy detection, for astrophysics and cosmology. We use a matched filter to compute the luminosity detection threshold for individual sources. We show that LIM contains information about galaxies too faint to detect, in the high-noise or high-confusion regimes. We quantify the sparsity and clustering bias of the detected sources and compare them to LIM, showing in which cases LIM is a better tracer of the matter density. We extend previous work by answering these questions as a function of Fourier scale, including for the first time the effect of cosmic variance, pixel-to-pixel correlations, luminosity-dependent clustering bias and redshift-space distortions.

79 ASTRONOMY AND ASTROPHYSICS↗