Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pile-up”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using pile-up collisions as an abundant source of low-energy hadronic physics processes in ATLAS and an extraction of the jet energy resolution

During the 2015–2018 data-taking period, the Large Hadron Collider delivered proton-proton bunch crossings at a centre-of-mass energy of 13 TeV to the ATLAS experiment at a rate of roughly 30 MHz, where each bunch crossing contained an average of 34 independent inelastic proton-proton collisions. The ATLAS trigger system selected roughly 1 kHz of these bunch crossings to be recorded to disk. Offline algorithms then identify one of the recorded collisions as the collision of interest for subsequent data analysis, and the remaining collisions are referred to as pile-up. Pile-up collisions represent a trigger-unbiased dataset, which is evaluated to have an integrated luminosity of 1.33 pb -1 in 2015–2018. This is small compared with the normal trigger-based ATLAS dataset, but when combined with vertex-by-vertex jet reconstruction it provides up to 50 times more dijet events than the conventional single-jet-trigger-based approach, and does so without adding any additional cost or requirements on the trigger system, readout, or storage. The pile-up dataset is validated through comparisons with a special trigger-unbiased dataset recorded by ATLAS, and its utility is demonstrated by means of a measurement of the jet energy resolution in dijet events, where the statistical uncertainty is significantly reduced for jet transverse momenta below 65 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of W±-boson differential cross-sections in proton–proton collisions with low pile-up data at s=5.02 TeV and 13TeV with the ATLAS detector

High precision single-differential W±$$W^\pm $$-boson production cross-sections as a function of electron or muon transverse momentum pT$$p_\textrm{T}$$ or their pseudorapity η$$\eta $$, as well as double-differential cross-sections as functions of these variables, are measured in proton–proton collisions at centre-of-mass energies s=5.02$$\sqrt{s}=5.02$$ TeV and 13 TeV. The W-boson charge asymmetry as a function of lepton η$$\eta $$ is also measured. The data, collected in dedicated runs at reduced instantaneous luminosity with the ATLAS detector at the Large Hadron Collider, correspond to integrated luminosities of 255 pb-1$$^{-1}$$ at 5.02 TeV and 338 pb-1$$^{-1}$$ at 13 TeV. The measurements are in agreement with Standard-Model predictions calculated at next-to-next-to-leading-order in the strong coupling constant αs$$\alpha _s$$ including transverse-momentum resummation at next-to-next-to-leading logarithmic accuracy using several parton distribution functions. The impact of the measured differential cross-sections as a function of lepton η$$\eta $$ on the determination of these functions is studied using a profiling technique.

Aad, G↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The performance of missing transverse momentum reconstruction and its significance with the ATLAS detector using 140 $\hbox {fb}^{-1}$ of $\sqrt{s}=13$ TeV pp collisions

This paper presents the reconstruction of missing transverse momentum ($p_{\text {T}}^{\text {miss}}$ ) in proton–proton collisions, at a center-of-mass energy of 13 TeV. This is a challenging task involving many detector inputs, combining fully calibrated electrons, muons, photons, hadronically decaying $\tau$ -leptons, hadronic jets, and soft activity from remaining tracks. Possible double counting of momentum is avoided by applying a signal ambiguity resolution procedure which rejects detector inputs that have already been used. Several $p_{\text {T}}^{\text {miss}}$ ‘working points’ are defined with varying stringency of selections, the tightest improving the resolution at high pile-up by up to 39% compared to the loosest. The $p_{\text {T}}^{\text {miss}}$ performance is evaluated using data and Monte Carlo simulation, with an emphasis on understanding the impact of pile-up, primarily using events consistent with leptonic Z decays. The studies use $140~\text {fb}^{-1}$ of data, collected by the ATLAS experiment at the Large Hadron Collider between 2015 and 2018. The results demonstrate that $p_{\text {T}}^{\text {miss}}$ reconstruction, and its associated significance, are well understood and reliably modelled by simulation. Finally, the systematic uncertainties on the soft $p_{\text {T}}^{\text {miss}}$ component are calculated. After various improvements the scale and resolution uncertainties are reduced by up to 76% and 51%, respectively, compared to the previous calculation at a lower luminosity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the W-boson angular coefficients and transverse momentum in pp collisions at s=13 TeV with the ATLAS detector

The angular distributions of Drell–Yan lepton pairs provide sensitive probes of the underlying dynamics of quantum chromodynamics (QCD) effects in vector-boson production. This paper presents for the first time the measurement of the full set of angular coefficients together with the differential cross-section as a function of the transverse momentum of the W boson, in the full phase space of the decay leptons. The measurements are performed separately for the W-$$W^-$$ and W+$$W^+$$ channels. The analysis uses proton–proton collision data recorded by the ATLAS experiment at the Large Hadron Collider in 2017 and 2018, during special low-luminosity runs with a reduced number of interactions per bunch crossings (pile-up). The data correspond to an integrated luminosity of 338 pb-1$$^{-1}$$ at a centre-of-mass energy of s=13$$\sqrt{s} = 13$$ TeV. The low pile-up environment provides excellent experimental conditions for high-precision measurements of W-boson production. All results agree with theoretical predictions incorporating finite-order QCD corrections up to order αS2$$\alpha _S^2$$.

Aad, G↗

Trigger-System Development for the HGCAL Cassette Testing (Final Report, Summer Internship 2023)

The Large Hadron Collider (LHC) will be upgraded to increase the instantaneous luminosity, which will result in an increase in the number of collisions from the 15 pile-up events of the first run of phase 1 to the 150-200 pile-up events of phase 2. Increasing the number of collisions means increasing the amount of radiation that the experiments will absorb. To meet these challenging conditions, the CMS calorimeters need to be upgraded. The new version of the hadronic HGCAL (High Granularity CALorimeters) in the endcaps will be assembled and tested in Fermilab’s laboratory. This report describes the new trigger system for testing the HGCAL’s cassettes.

42 ENGINEERING↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Light dark matter constraints from SuperCDMS HVeV detectors operated underground with an anticoincidence event selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g−days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/𝑐 2 , as well as upper limits on dark photon kinetic mixing and axionlike particle axioelectric coupling for masses between 1.2 and 23.3 eV/𝑐 2 . Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross section sensitivity was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Estimation of backgrounds from jets misidentified as τ-leptons using the Universal Fake Factor method with the ATLAS detector

Processes with τ$$\tau $$-leptons in the final state are important for Standard Model measurements and searches for physics beyond the Standard Model. The ATLAS experiment at the Large Hadron Collider observes τ$$\tau $$-leptons produced in proton–proton collisions only through their decay products. Data analyses involving hadronically decaying τ$$\tau $$-leptons face challenges due to backgrounds from jets misidentified as τ$$\tau $$-leptons that are not modelled reliably by Monte Carlo simulations. Data-driven methods such as the fake-factor method allow such misidentified backgrounds to be predicted by measuring transfer factors, known as fake factors, in data from dedicated regions. This paper describes a refined technique for determining the fake factors, the Universal Fake Factor method. It evaluates the fake factors for a signal region by using fake factors from samples enriched in different sources of jets misidentified as τ$$\tau $$-leptons (light-quark, gluon, b-quark, and pile-up jets). Each fake factor is calculated as a linear combination of fake factors measured in these different enriched samples. For the full Run 2 data set, the systematic uncertainty of the calculated fake factors, evaluated using W(μν)$$W(\mu u )$$ enriched event sample, ranges from 15 to 35% depending on the τ$$\tau $$-lepton’s transverse momentum and charged-particle decay multiplicity.

Aad, G↗

Multichannel analyzers at high rates of input

Multichannel analyzer, used with a gating system incorporating pole-zero compensation, pile-up rejection, and baseline-restoration, achieves good resolution at high rates of input. It improves resolution, reduces tailing and rate-contributed continuum, and eliminates spectral shift.

Rudnick, S. J.↗

Fast-neutron spectrometer developments

Li6 sandwich-type neutron spectrometer is equipped with proportional counter for particle identification. System uses current-sensitive preamplifiers to minimize pile-up of gamma-ray and particle pulses.

Moler, R. B.↗

Quantitative simultaneous multi-element microprobe analysis using combined wavelength and energy dispersive systems

A combined WDS-EDS system obviates the severe X-ray peak overlap problems encountered with Na, Mg, Al and Si common to pure EDS systems. By application of easily measured empirical correction factors for pulse pile-up and peak overlaps which are normally observed in the analysis of silicate minerals, the accuracy of analysis is comparable with that expected for WDS electron microprobe analyses. The continuum backgrounds are subtracted for the spectra by a spline fitting technique based on integrated intensities between the peaks. The preprocessed data are then reduced to chemical analyses by existing data reduction programs.

Walter, L. S.↗

Calorimeter Pileup Deconvolution for Online Trigger Primitives

In high energy physics experiment, as the luminosity increases, pile-up issues on detectors such as calorimeters become non-negligible. Deconvolution approaches with mathematic pre-assumptions such as Sparse Representation are developed for data analysis stage. For online computation tasks such as for trigger primitive creation, signal availability is significantly different as in offline data analysis stage, and therefore, different (yet simpler) algorithms should be explored. In this document, several approaches of deconvolution suitable for FPGA implementation are discussed.

Wu, Jin-yuan [Fermilab] (ORCID:0000000344329521)↗