Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photovoltaic system degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of clear-sky and satellite-derived irradiance data for determining the degradation of photovoltaic system performance

Knowing the degradation in performance of a photovoltaic (PV) system over time is important for estimating the lifetime energy produced and the financial return. A key parameter for normalizing performance and determining degradation is the plane-of-array (POA) irradiance. Because accurate long-term POA measurements are not always readily available, three methods of providing irradiance data for determining the degradation rate of PV systems were evaluated—a method using irradiance data modeled with the Ineichen clear-sky model and monthly Linke turbidity coefficients, a method using the supplemental clear-sky irradiance data from the National Solar Radiation Data Base (NSRDB), and a method using the NSRDB solar irradiance data for both cloudy and clear-sky conditions (all-sky). The irradiance data from the three methods were evaluated using measured irradiance data from 1998 through 2018 for the seven-station SURFRAD network and for 3-, 5-, and 10-year periods that might be used for evaluating PV system performance. Only the two clear-sky methods for the 10-year periods had less uncertainty with respect to determining PV system degradation than the expected median degradation rate for PV systems of -0.5%/year to -0.6%/year. Shorter periods and the all-sky method had larger uncertainties, making their use questionable for determining the degradation rates of PV systems.

14 SOLAR ENERGY↗

Assessing Machine Learning as a Tool to Explain Variance in Deployed Photovoltaic (PV) System Degradation

Degradation remains a large uncertainty in forecasting production for PV plants, creating significant risk for developers and financiers. This study aims to quantify the distribution and drivers of degradation across 10,000 PV systems deployed for distributed or utility generation by training a machine learning model to predict year-over-year degradation rates from metadata characteristics. A combination of K-Means clustering and random forest regressor were found to associate multiple metadata features as potential drivers of degradation, including module characteristics, system design, and climate features. From this, it is inferred that if machine learning is able to find complex patterns between metadata features and system performance loss, such methods can be employed to help developers and financiers make data-informed decisions when estimating long-term energy production forecasts in financial models.

Dunn, Jimmy C.↗

Numerical Validation of an Algorithm for Combined Soiling and Degradation Analysis of Photovoltaic Systems

We describe and demonstrate an open-source algorithm for simultaneously quantifying degradation and soiling of photovoltaic (PV) systems from energy-production time series data. The new analysis is based on year-on-year degradation rate analysis combined with stochastic rate and recovery soiling analysis. The algorithm is designed to fit into the workflow provided by RdTools, a Python module maintained by NREL and collaboratively developed with the community, which provides a framework and functions for degradation and loss-factor analysis of PV field data. We demonstrate the method on numerically simulated PV data sets and show that it reduces the root-mean-square error of the P50 degradation rate estimate when soiling is present.

14 SOLAR ENERGY↗

Impact of duration and missing data on the long-term photovoltaic degradation rate estimation

Accurate quantification of photovoltaic (PV) system degradation rate (R D ) is essential for lifetime yield predictions. Although R D is a critical parameter, its estimation lacks a standardized methodology that can be applied on outdoor field data. The purpose of this paper is to investigate the impact of time period duration and missing data on R D by analyzing the performance of different techniques applied to synthetic PV system data at different linear R D patterns and known noise conditions. The analysis includes the application of different techniques to a 10-year synthetic dataset of a crystalline Silicon PV system, with emulated degradation levels and imputed missing data. Here, the analysis demonstrated that the accuracy of ordinary least squares (OLS), year-on-year (YOY), autoregressive integrated moving average (ARIMA) and robust principal component analysis (RPCA) techniques is affected by the evaluation duration with all techniques converging to lower R D deviations over the 10-year evaluation, apart from RPCA at high degradation levels. Moreover, the estimated R D is strongly affected by the amount of missing data. Filtering out the corrupted data yielded more accurate R D results for all techniques. It is proven that the application of a change-point detection stage is necessary and guidelines for accurate R D estimation are provided.

14 SOLAR ENERGY↗

Light and Elevated Temperature Induced Degradation (LeTID) in a Utility-Scale Photovoltaic System

Here, we present a detailed case study of degradation in monocrystalline silicon photovoltaic modules operating in a utility-scale power plant over the course of approximately three years. We present the results of degradation analysis on arrays within the site, and find that five of the six arrays degraded faster than the best performing array, even though the arrays consist of modules of the same manufacturer and model. We also describe the results of extensive laboratory characterization of modules returned from the field, including module- and cell-level current–voltage characterization, luminescence imaging, and accelerated testing. The laboratory test results and the field performance are consistent with light and elevated temperature induced degradation (LeTID). Notably, we observe differences in back contact technology between affected and unaffected modules. This article also demonstrates a method to identify possible LeTID degradation in the field and confirm the result with laboratory testing of a small number of modules.

14 SOLAR ENERGY↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Monitoring of Photovoltaic (PV) Performance and Degradation: Integrated Renewable Energy Systems (IRES) - PV Monitoring Task

The Integrated Renewable Energy System (IRES) testbed demonstration at the Pacific Northwest National Laboratory (PNNL) Sequim campus includes development of a suite of capabilities for tracking the performance of photovoltaic (PV) renewable energy components located on a floating platform (floating PV) and on a shoreline building rooftop. The marine environment represents potentially harsh and corrosive conditions for PV modules. Compared to terrestrial PV, potential concerns for offshore PV arising from high humidity and occasional contact with saltwater, marine wildlife, and aquaculture. These environmental factors can reduce electricity generation efficiency and increase the risk of electrical faults, polymer insulation or jacketing degradation and hydrolysis of the PV cell encapsulant materials. Offshore PV modules may also be exposed to lower temperatures and buoyant and vibrating motions with a floating platform. It is not clear how the long-term performance of floating PV will be affected by these factors. To understand expected energy generation through solar cells on a floating platform, monitoring of the performance of PV modules in the marine environment is needed. This report outlines a plan for long-term testing of IRES PV components utilizing resources of the PNNL Material Aging and Detection (MAaD) Science team and the Marine and Coastal Research Laboratory (MCRL). Equipment applicable for onsite testing and real-time monitoring of the PV performance associated with environmental conditions including temperature, solar irradiance, shading and soiling is included. In case of performance loss, equipment for fault detection, failure analysis, material testing, and further troubleshooting are also available. Through establishment of this capabilities, the enabling IRES project sets the stage for future research to advance off-shore and near-shore energy options for businesses and communities.

14 SOLAR ENERGY↗

Light- and Elevated-Temperature-Induced Degradation-Affected Silicon Cells From a Utility-Scale Photovoltaic System Characterized by Deep-Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated-temperature-induced degradation (LeTID). Samples from the affected monocrystalline silicon cells are cored and extracted from the module packaging and then laser-scribed to form 2-mm diameter isolated areas. Using deep-level transient spectroscopy, a majority-carrier, hole-trap defect with an activation energy of 0.42 eV is detected on degraded and regenerated samples. The LeTID-degraded sample, however, has a larger signal corresponding to a trap density of 1.1 x 10 13 cm -3 , which is about five times larger than the 2.1 x 10 12 cm -3 trap density of the regenerated sample. An increase in filling pulse time from 50 u s to 20 ms shows a slight decrease in activation energy from 0.42 to 0.36 eV suggesting that the defect level may consist of a band of energy states where shallower states continue to fill with long filling times. The capture rate of the defect is directly measured using an increasing series of filling pulsewidths in 15 to 125 ns range. This leads to a measured capture cross section of 5.1 x 10 -17 cm 2 , and using an approximate defect density of 10 13 cm -3 , the majority-carrier-hole lifetime related to this defect is approximately 100 u s when in the LeTID-degraded state.

charge carrier lifetime↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Degradation of Monocrystalline Silicon Photovoltaic Modules From a 10-Year-Old Rooftop System in Florida

A system of 180 monocrystalline aluminum back-surface field modules were installed in Cocoa, Florida, for 10 years. In total, 156 modules are characterized and compared to 3 controls. Power degradation rates vary between – 0.14% to – 3.22% per year, with median and average rates of –0.92% and –1.05% per year, respectively. The losses are primarily resistive with minor optical and recombination loss contributions. Electroluminescence imaging shows a characteristic pattern, which is shown to be resistive in nature when compared to photoluminescence. Resistive losses are due to corrosion of the rear contact Ag/solder interface and, to a much lesser degree, gridline Ag oxidation. Moisture ingress through the backsheet is likely responsible for mediating corrosion. Optical losses are due mostly to a combination of antireflection coating degradation, minor encapsulant browning, and delamination. Minor front contact corrosion may contribute to recombination. Furthermore, this study expands upon previous work on this vintage of the module by examining a large sample set, comprehensive characterization including techniques not previously used on these modules, and a comparison between two other systems of different climates.

14 SOLAR ENERGY↗

PV Degradation Modeling: Applying Geospatial Workflows with "PVDeg"

Accurate degradation modeling is essential for predicting photovoltaic (PV) module performance, estimating longevity and informing design decisions. With degradation rates varying significantly by location, geospatial analysis is critical for PV and broader applications, such as agrivoltaics, weathering and environmental data analysis. This work presents PVDeg, an open-source tool designed for geospatial degradation analysis. PVDeg integrates meteorological data from global sources, including the National Solar Radiation Database (NSRDB) and Photovoltaic Geographical Information System (PVGIS), with degradation models. The toolkit enables users to customize geospatial workflows by integrating weather data, material parameters, and user-defined Python functions. It facilitates accelerated downloads of NSRDB and PVGIS datasets and optimizes geospatial point selection to preserve data density in regions of interest. Additionally, PVDeg provides a local database for storage and spatial queries, supporting large-scale analyses without the need for high-performance computing (HPC) resources. PVDeg provides a foundational workflow that extends its utility beyond PV applications, enabling researchers to analyze geospatial processes across discipline.

14 SOLAR ENERGY↗

Multiscale Characterization of Photovoltaic Modules—Case Studies of Contact and Interconnect Degradation

The current popularity of photovoltaic (PV) systems is due in large part to their exceptional reliability and significantly lower cost than other energy sources. Studying cell and module degradation is key to promote further development in the state of the art. Fielded or accelerated aged modules exhibit different failure modes, of which metallization degradation (contacts and interconnections) is prevalent. In this work, we discuss how multiscale characterization methods can be applied to a variety of module technologies that have been field exposed and have undergone accelerated age testing. These methods include performing characterization on the module level, cell level, and finally the materials level. The observed performance losses from the module- and cell-level characterization can be correlated with materials properties to find out the root cause of degradation. We recommend an initial nondestructive characterization suite, including module- and cell-level current-voltage ( I--V ), Suns-V OC , photoluminescence and electroluminescence imaging, quantum efficiency, ultraviolet fluorescence imaging, and thermal infrared imaging. Samples are then extracted from particularly degraded regions of the module and prepared for materials characterization techniques, such as top-down and cross-sectional scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, Raman spectroscopy, and transmission electron microscopy, allowing a deeper look into the mechanism behind the metallization degradation. This article serves as an instructional review to introduce the different multiscale characterization methods and how they can be effectively applied to perform PV degradation studies. Furthermore, we also share some of our examples and discuss the strengths, limitations, and best practices for each of the characterization techniques.

14 SOLAR ENERGY↗

Correspondence: Bill of Materials Variation and Module Degradation in Utility-Scale PV Systems

We report photovoltaic (PV) modules of the same make and model are often assembled with different bills of materials (BOMs). In this correspondence, we revisit two case studies of utility-scale silicon PV systems in which these differing BOMs were associated with faster-than-expected degradation. In one of the sites, we found that different metallization paste had been used for grid lines in some cells leading to loss of contact to the cell and severe series resistance degradation. We provide details on the observation of this mechanism at two additional sites not described in the original article. In a second case study, we found that two different types of cell had been used, and that they could be distinguished by their back contact. Cells with uniform back contacts suffered from light and elevated temperature induced degradation (LeTID), while those with local back contacts did not. We also briefly describe BOM variations observed at other sites to illustrate the extent of the challenge. Our results from both sites underscore that variations in BOM, even among modules of the same make and model can lead to reliability challenges.

14 SOLAR ENERGY↗