Engineering PapersSearch

SEARCH · Engineering Papers

Results for “photonic integrated circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer

Integrated Inverter And Battery Charger

Circuit combines functions of dc-to-ac inversion (for driving ac motor in battery-powered vehicle) and ac-to-dc conversion (for charging battery from ac line when vehicle not in use). Automatically adapts to either mode. Design of integrated inverter/charger eliminates need for duplicate components, saves space, reduces weight and cost of vehicle. Advantages in other applications : load-leveling systems, standby ac power systems, and uninterruptible power supplies.

Rippel, Wally E.

Remote Sensing-Driven Hydrodynamic Modeling in Data-Scarce Regions: Integrating ICESat-2, Sentinel-2, SWOT and Re-analysis Models for Coastal Monitoring

Hydrodynamic models in coastal and estuarine systems are typically constrained by sparse bathymetry, boundary, and validation data, especially in regions where field campaigns are costly or impractical. Here we develop and test a fully satellite-driven framework for hydrodynamic modeling in South Africa’s Langebaan Lagoon without using any local in situ measurements. Bathymetry is derived by training multispectral Sentinel-2 reflectance against ICESat-2 ATL24 photon-derived depths using an XGBoost model optimized with Bayesian search. The final satellite-derived bathymetry reproduces independent ATL24 points with RMSE = 0.45 m and R 2 = 0.97. This bathymetry was used in a depth-averaged Delft3D Flexible Mesh model driven at the open boundary by TPXO tidal harmonics and by ERA5 winds. We validate modeled water surface elevation against 16 SWOT low-rate (250 m, unsmoothed) passes in 2023. SWOT–model comparisons yield an overall RMSE of 0.11 m and R 2 = 0.61, with typical point differences <0.10 m (∼7% of the 1.5 m tidal range), and showed consistent spatial gradients in water level from the offshore boundary, through Saldanha Bay, and into the lagoon. At the offshore boundary, TPXO and SWOT sea surface heights agree closely (R 2 = 0.86). A simple phase adjustment of ∼26,min between TPXO and SWOT lowers the RMSE from 0.18,m to 0.11,m, showing that phase offset accounts for some of the discrepancy, with additional errors likely linked to non-tidal signals. Our results demonstrate that combining passive optical, photon-counting LiDAR, radar interferometry, and global tidal/atmospheric models enables robust, transferrable hydrodynamic modeling in data-scarce coastal systems, offering a cost-effective pathway for monitoring.

ICESat-2

Circuit with a Switch for Charging a Battery in a Battery Capacitor Circuit

A circuit for charging a battery combined with a capacitor includes a power supply adapted to be connected to the capacitor, and the battery. The circuit includes an electronic switch connected to the power supply. The electronic switch is responsive to switch between a conducting state to allow current and a non-conducting state to prevent current flow. The circuit includes a control device connected to the switch and is operable to generate a control signal to continuously switch the electronic switch between the conducting and non-conducting states to charge the battery.

Stuart, Thomas A.

Resistor Extends Life Of Battery In Clocked CMOS Circuit

Addition of fixed resistor between battery and clocked complementary metal oxide/semiconductor (CMOS) circuit reduces current drawn from battery. Basic idea to minimize current drawn from battery by operating CMOS circuit at lowest possible current consistent with use of simple, fixed off-the-shelf components. Prolongs lives of batteries in such low-power CMOS circuits as watches and calculators.

Wells, George H., Jr.

A nickel-cadmium battery reconditioning circuit

The circuit presented is simple and small enough to be included in a typical battery charge/power control assembly, yet provides the advantage of a complete ground-type battery reconditioning discharge. Test results on the circuit when used to recondition two 24 cell, 20 A-h nickel-cadmium batteries are given. These results show that a battery reconditioned with this circuit returns to greater than 90 percent of its original capacity (greater than nameplate capacity) and follows a typical new battery degradation curve even after over 20,000 simulated orbital cycles for a 4 year period. Applications of the circuit are considered along with recommendations relative to its use. Its application in low voltage (22 to 36 Vdc) power systems and in high voltage (100 to 150 Vdc) power systems is discussed. The implications are that the high voltage systems have a greater need for battery reconditioning than their low voltage counterparts, and that using these circuit techniques, the expected life of a battery in low Earth orbit can be up to 5 years.

Lanier, R.

Battery Charge Equalizer with Transformer Array

High-power batteries generally consist of a series connection of many cells or cell banks. In order to maintain high performance over battery life, it is desirable to keep the state of charge of all the cell banks equal. A method provides individual charging for battery cells in a large, high-voltage battery array with a minimum number of transformers while maintaining reasonable efficiency. This is designed to augment a simple highcurrent charger that supplies the main charge energy. The innovation will form part of a larger battery charge system. It consists of a transformer array connected to the battery array through rectification and filtering circuits. The transformer array is connected to a drive circuit and a timing and control circuit that allow individual battery cells or cell banks to be charged. The timing circuit and control circuit connect to a charge controller that uses battery instrumentation to determine which battery bank to charge. It is important to note that the innovation can charge an individual cell bank at the same time that the main battery charger is charging the high-voltage battery. The fact that the battery cell banks are at a non-zero voltage, and that they are all at similar voltages, can be used to allow charging of individual cell banks. A set of transformers can be connected with secondary windings in series to make weighted sums of the voltages on the primaries.

Davies, Francis

Calibration of the Receiver Channel for the GOPEX Precursor Experiments

Calibration measurements for the cooled (253 K) photomultiplier tube (PMT) detector, used on the receiver channel of the transmit/receive (T/R) switch for GOPEX, were conducted in the laboratory. A pulsed frequency-doubled neodymium:yttrium-aluminum-garnet (Nd:YAG) laser was used to direct 532-mn light on the PMT. By monitoring the energy per pulse of the light incident on the PMT, the minimum number of photons detected could be determined. These results agreed with the photon flux back-calculated from the PMT output waveform. Approximately 700 incident photons arriving during a temporal pulse width of approximately 65 nsec were detected with a signal-to-noise ratio (SNR) of approximately 1. Other receiver channel characteristics, such as PMT dark currents, optical transmission, and interference filter sensitivity to angle of light incidence, were also measured.

A Biswas

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume

Mathematical Characterization of Battery Models

The purpose of this document is to demonstrate the use of the Extended Kalman Filter as a tool for battery state estimation and the estimation of battery state of charge. The mathematical details based on the equivalent circuit model are presented followed by an electrochemical engineering model. A simplified first-order model is used to demonstrate the procedure followed by second and third-order models. Next a simplified electrochemistry model is presented along with observer development. State observability is calculated for the simpler equivalent circuit models and the simplified electrochemistry model. An outline of the battery model parameter identification method is presented, and model performance based on experimental and flight data is demonstrated.

Battery

A Battery Charger and State of Charge Indicator

A battery charger which has a full wave rectifier in series with a transformer isolated 20 kHz dc-dc converter with high frequency switches, which are programmed to actively shape the input dc line current to be a mirror image of the ac line voltage is discussed. The power circuit operates at 2 kW peak and 1 kW average power. The BC/SCI has two major subsystems: (1) the battery charger power electronics with its controls; and (2) a microcomputer subsystem which is used to acquire battery terminal data and exercise the state of charge software programs. The state of charge definition employed is the energy remaining in the battery when extracted at a 10 kW rate divided by the energy capacity of a fully charged new battery. The battery charger circuit is an isolated boost converter operating at an internal frequency of 20 kHz. The switches selected for the battery charger are the single most important item in determining its efficiency. The combination of voltage and current requirements dictate the use of high power NPN Darlington switching transistors. The power circuit topology is a three switch design which utilizes a power FET on the center tap of the isolation transformer and the power Darlingtons on each of the two ends. An analog control system is employed to accomplish active input current waveshaping as well as the necessary regulation.

Latos, T. S.

Self Discharge of Nickel-Hydrogen Cells

Values for the capacity loss with time, naturally on open circuit stand, and information regarding the minimum amount of circuit charge needed to keep the cell charged can be determined from the self-discharge behavior of nickel hydrogen cells. Furthermore, the rate of reaction between hydrogen and a charged nickel electrode is also open for nickel cadmium batteries. In a nickel hydrogen cell, the hydrogen is stored as pressurized gas and the cell stack with the charge that is oxidized nickel-hydroxide electrode is in direct contact with the hydrogen. Therefore, the rate of reaction can be measured easily and precisely by monitoring the charge, the change in hydrogen pressure with time. Measures made on twelve 15 ampere hour nickel hydrogen cells of different stack configurations built for COMSAT are discussed.

G Holleck

Pocket nickel cadmium cell and battery evaluation

The Nickel Cadmium 129-ampere hour cell was tested in order to characterize the cell under controlled conditions. Results of charge characterization and discharge characterization are reported. Ampere hour efficiency, open circuit stand, and cycle life operation results are included. The battery is briefly described.

Lear, J. W.

The 2004 NASA Aerospace Battery Workshop

Topics covered include: Super NiCd(TradeMark) Energy Storage for Gravity Probe-B Relativity Mission; Hubble Space Telescope 2004 Battery Update; The Development of Hermetically Sealed Aerospace Nickel-Metal Hydride Cell; Serial Charging Test on High Capacity Li-Ion Cells for the Orbiter Advanced Hydraulic Power System; Cell Equalization of Lithium-Ion Cells; The Long-Term Performance of Small-Cell Batteries Without Cell-Balancing Electronics; Identification and Treatment of Lithium Battery Cell Imbalance under Flight Conditions; Battery Control Boards for Li-Ion Batteries on Mars Exploration Rovers; Cell Over Voltage Protection and Balancing Circuit of the Lithium-Ion Battery; Lithium-Ion Battery Electronics for Aerospace Applications; Lithium-Ion Cell Charge Control Unit; Lithium Ion Battery Cell Bypass Circuit Test Results at the U.S. Naval Research Laboratory; High Capacity Battery Cell By-Pass Switches: High Current Pulse Testing of Lithium-Ion; Battery By-Pass Switches to Verify Their Ability to Withstand Short-Circuits; Incorporation of Physics-Based, Spatially-Resolved Battery Models into System Simulations; A Monte Carlo Model for Li-Ion Battery Life Projections; Thermal Behavior of Large Lithium-Ion Cells; Thermal Imaging of Aerospace Battery Cells; High Rate Designed 50 Ah Li-Ion Cell for LEO Applications; Evaluation of Corrosion Behavior in Aerospace Lithium-Ion Cells; Performance of AEA 80 Ah Battery Under GEO Profile; LEO Li-Ion Battery Testing; A Review of the Feasibility Investigation of Commercial Laminated Lithium-Ion Polymer Cells for Space Applications; Lithium-Ion Verification Test Program; Panasonic Small Cell Testing for AHPS; Lithium-Ion Small Cell Battery Shorting Study; Low-Earth-Orbit and Geosynchronous-Earth-Orbit Testing of 80 Ah Batteries under Real-Time Profiles; Update on Development of Lithium-Ion Cells for Space Applications at JAXA; Foreign Comparative Technology: Launch Vehicle Battery Cell Testing; 20V, 40 Ah Lithium Ion Polymer Battery for the Spacesuit; Low Temperature Life-Cycle Testing of a Lithium-Ion Battery for Low-Earth-Orbiting Spacecraft; and Evaluation of the Effects of DoD and Charge Rate on a LEO Optimized 50 Ah Li-Ion Aerospace Cell.

Source record

A high reliability battery management system

Over a period of some 5 years Canadian Astronautics Limited (CAL) has developed a system to autonomously manage, and thus prolong the life of, secondary storage batteries. During the development, the system was aimed at the space vehicle application using nickel cadmium batteries, but is expected to be able to enhance the life and performance of any rechargeable electrochemical couple. The system handles the cells of a battery individually and thus avoids the problems of over, and under, drive that inevitably occur in a battery of cells managed by an averaging system. This individual handling also allow cells to be totally bypassed in the event of failure, thus avoiding the losses associated with low capacity, partial short circuit, and the catastrophe of open circuit. The system has an optional capability of managing redundant batteries simultaneously, adding the advantage of on line reconditioning of one battery, while the other maintains the energy storage capability of the overall system. As developed, the system contains a dedicated, redundant, microprocessor, but the capability exists to have this computing capability time shared, or remote, and operating through a data link. As adjuncts to the basic management system CAL has developed high efficiency, polyphase, power regulators for charge and discharge power conditioning.

Moody, M. H.

Pressure Switch Is a Low Cost Battery Indicator

Conventional pressure switch, fabricated by printed-circuit manufacturing techniques, can indicate when charge on battery departs from preset level. Membrane on switch is exposed to internal pressure of battery, which varies according to stored charge. When pressure varies from preset level, switch can turn on a light-emitting diode or similar indicator to warn user that battery is low.

Abita, J. L.

Ampere-Hour Meter For Rechargeable Battery

Low-power analog/digital electronic circuit meters discharge of storage battery in ampere-hours. By metering discharge, one obtains indication of state of charge of battery and avoids unnecessary recharging, maintaining capacity of battery and prolonging life. Because of its small size and low power consumption, useful in such applications as portable video cameras, communication equipment on boats, portable audio equipment, and portable medical equipment.

Tripp, John S.