Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon-counting detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Two-dimensional photon-counting detector arrays based on microchannel array plates

The production of simple and rugged photon-counting detector arrays has been made possible by recent improvements in the performance of the microchannel array plate (MCP) and by the parallel development of compatible electronic readout systems. The construction of proximity-focused MCP arrays of novel design in which photometric information from (n x m) picture elements is read out with a total of (n + m) amplifier and discriminator circuits is described. Results obtained with a breadboard (32 x 32)-element array employing 64 charge-sensitive amplifiers are presented, and the application of systems of this type in spectrometers and cameras for use with ground-based telescopes and on orbiting spacecraft discussed.

Timothy, J. G.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Photon-counting array detectors for space and ground-based studies at ultraviolet and vacuum ultraviolet /VUV/ wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric photon-counting array detectors, with formats as large as (256 x 1024)-pixels that can be operated in a windowless configuration at vacuum ultraviolet (VUV) and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. This paper describes the construction and modes of operation of (1 x 1024)-pixel and (24 x 1024)-pixel MAMA detector systems that are being built and qualified for use in sounding-rocket spectrometers for solar and stellar observations at wavelengths below 1300 A. The performance characteristics of the MAMA detectors at ultraviolet and VUV wavelengths are also described.

Timothy, J. G.↗

A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

Hartig, G. F.↗

Multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are described.

Timothy, J. G.↗

A progress report on multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are briefly described.

Timothy, J. G.↗

Development and test of photon-counting microchannel plate detector arrays for use on space telescopes

The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.

Timothy, J. G.↗

Recent progress with multi-anode microchannel array detector systems

The construction and modes of operation of Multi-Anode Microchannel Arrays (MAMA's) are briefly reviewed. The MAMA detectors, which are a family of photoelectric, photon-counting array detectors being developed specifically for use in instruments on ground-based and space-borne telescopes, combine the high sensitivity and photometric stability of a conventional channel electron multiplier with a high-resolution imaging capability. The MAMA detectors feature low applied potential (less than 3 kV), high gain (greater than 10 to the 6th electrons/pulse), an absolute event timing accuracy of 100 ns or better, a very long count lifetime (greater than 2.5 x 10 to the 11th counts/sq mm), and a power consumption of less than 30 W for a complete system

Timothy, J. G.↗

An evaluation of an ICCD imager of dynamic range expansion technique and application of insitu procedures for life-time extension

Research toward practical implementation of the Intensified Charge Coupled Device (ICCD) as a photon-counting array detector for astronomy is reported. The first area of concentration was to determine the rate and extent of the lifetime limiting damage to the CCD caused by the impact of high energy electrons, and to find whether various methods of annealing the damage were productive. The second effort was to determine the performance of the ICCD in a photon-counting mode to produce extended dynamic range measurements. There are two main effects that appear as the practical results of the electron damage to the CCD. One is an increase in the leakage current, i.e., the normal thermal generation of charge carriers in the silicon that provides a background dark signal that adds to the light produced image. In an undamaged CCD, the leakage current is usually fairly uniform across the photosensitive area of the silicon chip, with the exception of various bright pixels which have an anomalous leakage current well above the overall level.

Currie, D. G.↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

The Johns Hopkins Ultraviolet Telescope for Shuttle astronomy

The Hopkins Ultraviolet Telescope (HUT) is a 90-cm f/2 prime focus telescope and spectrometer with a photon-counting microchannel plate detector designed to obtain moderate resolution (wavelength interval, approximately 4 A) spectrophotometry of faint (visual magnitude, less than approximately 17) objects in the far-ultraviolet spectral region (approximately 900-1700 A). The HUT will be mounted on the Spacelab Instrument Pointing System and will be operated by a Payload Specialist using a field acquisition TV system to assist in locating targets. The initial flight of the HUT, expected in 1984 or 1985, will be devoted primarily to the study of quasars and active galactic nuclei, emphasizing the 900-1200 A spectral region which is inaccessible with other existing or currently planned orbiting instruments.

Davidson, A. F.↗

Detection and Estimation of an Optical Image by Photon-Counting Techniques

Statistical description of a photoelectric detector is given. The photosensitive surface of the detector is divided into many small areas, and the moment generating function of the photo-counting statistic is derived for large time-bandwidth product. The detection of a specified optical image in the presence of the background light by using the hypothesis test is discussed. The ideal detector based on the likelihood ratio from a set of numbers of photoelectrons ejected from many small areas of the photosensitive surface is studied and compared with the threshold detector and a simple detector which is based on the likelihood ratio by counting the total number of photoelectrons from a finite area of the surface. The intensity of the image is assumed to be Gaussian distributed spatially against the uniformly distributed background light. The numerical approximation by the method of steepest descent is used, and the calculations of the reliabilities for the detectors are carried out by a digital computer.

Wang, Lily Lee↗

Rocket instrument for far-UV spectrophotometry of faint astronomical objects

A sensitive sounding rocket instrument for moderate (about 10-A) resolution far-UV (1160-1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employes a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.

Hartig, G. F.↗

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.↗

Development, applications, and future of infrared upconversion

Infrared upconversion is a technique that converts linearly polarized infrared photons to photons of higher frequency. The technique can be applied advantageously to the detection of IR radiation because the upconverted signal can be detected by photon-counting devices available for the visible spectral region. In addition, unlike presently available IR detectors, an upconversion device can provide sensitivity to IR radiation without the need for cryogenic cooling. Infrared upconversion was first demonstrated in 1961. By 1974, approximately 100% quantum conversion efficiency and a bandwidth of 1.81 microns had been attained. Photometric detection of IR radiation from various astronomical objects had also been demonstrated. Research is presently under way on the application of upconversion to astronomical spectroscopy and to imaging. The major drawback to the upconversion technique is the sheer bulk of the apparatus involved. It is anticipated that this problem can be overcome by applying the developing technology of integrated optics.

Gurski, T. R.↗

Infrared upconversion as a means of seeing in the dark

A new approach to seeing in the dark is described which is based on the principles of nonlinear optics employing a crystal such as lithium iodate. A nonlinear optical device capable of producing photons at higher frequencies from lower-frequency incident light is shown to upconvert infrared light directly into visible light. The major advantages of the infrared upconversion process is that it permits the infrared signal to be detected by photon-counting devices presently available for the visible spectral region, and that it can provide sensitivity to infrared radiation without the need for cryogenic cooling of the detector used. Early works on infrared upconversion are reviewed. The development of applications is discussed as to astronomical spectroscopy and infrared image upconversion involving either angular or positional resolution elements. The demonstration of infrared upconversion in rectangular waveguides of single-crystal GaAs by Anderson et al. (1971) indicates future possibilities in upconversion by the use of integrated optics devices.

Gurski, T. R.↗