Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photoinjector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

43 PARTICLE ACCELERATORS↗

Demonstration of Transverse-to-Longitudinal Emittance Exchange at the Fermilab Photoinjector

Phase space manipulation techniques with two degrees of freedom could be essential to the enhancement of the performance of next generation accelerators such as high energy colliders and accelerator-based light sources. At the Fermilab A0 Photoinjector, a proof-of-principle experiment to demonstrate the exchange of the transverse and longitudinal emittance is ongoing. The emittance exchange (EEX) beamline consists of a 3.9 GHz normal conducting deflecting mode cavity positioned between two doglegs as proposed by Kim and Sessler. The experiment is performed using electron bunches with charge of 250 pC and energy of 14.3 MeV. The incoming electron beam has transverse emittance of 2-4 mm mrad and longitudinal emittance of 10-14 mm mrad. After the EEX the measured horizonal emittance is blown up to 13-15 mm mrad while the measured vertical emittance (Non EEX plane) stays the same. At the same time the longitudinal emittance is reduced to 7-9 mm mrad as measued by the current longitudinal diagnostic tools. A linear optics model is established using the beam matrix calculated and measured. A first order simulation based on this model is performed to compare to our experiment results for both EEX measurement and the phase space manipulation experiment.

43 PARTICLE ACCELERATORS↗

First Horizontal Test Results of the HZB SRF Photoinjector for BERLinPro

The BERLinPro project, a small superconducting RF (SRF) c.w. energy recovery linac (ERL) is being built at Helmholtz-Zentrum Berlin in order to develop the technology required for operation of a high current, 100 mA, 50 MeV ERL. The electron source for the accelerator is a 1.4 cell SRF photoinjector fitted with a multi-alkali photocathode. As part of the HZB photoinjector development program three different SRF photoinjectors will be fabricated and tested. The photoinjector described herein is the second cavity that has been fabricated, and the first photoinjector designed for use with a multi-alkali photocathode. The photoinjector has been built and tested at JLab and subsequently shipped to HZB for testing in the horizontal test cryostat HoBiCaT prior to installation in the photoinjector cryomodule. This cryomodule will be used to measure the photocathode operation in a dedicated experiment called GunLab, the precursor to installation in the BERLinPro hall. This paper will report on the final results of the cavity installed in the helium vessel in the vertical testing dewar at Jefferson Lab as well as the first horizontal test in HoBiCaT

Burrill, A.↗

Overview of Photoinjectors

High-brightness electron beam sources play a crucial role in many advanced acceleration schemes as well as linac-based light sources such as Energy Recovery Linac (ERL) based light sources and FELs. Three varieties electron sources (photo, thermionic, and field emission) the photoinjector is especially attractive due to its innate ability to control the time structure of intense electron bunches with low transverse and longitudinal emittance. In all cases, the quality of the bunch begins with the intrinsic emittance and time response of the photocathode, and we discuss the trade-offs involved between the various material choices. A variety of longitudinal laser pulse-shaping techniques are currently being developed to linearize space charge forces or create trains of ultra-short bunches. The emittance compensation technique mitigates the growth of the projected emittance due to the linear space charge force while the bunch is accelerated and compressed in an injector. While the normal conducting rf photoinjector is the workhorse of this field, the dc photoinjector is being pushed to its high-voltage limits, and the year 2010 promises to be a critical year for the superconducting rf photoinjector. Parallel to the development of the hardware, rapid progress has also been made with modeling codes, theory, and bench marking of diagnostics. We attempt to give both a tutorial of photoinjectors and a review of the current state of the art in this rapidly developing field.

43 PARTICLE ACCELERATORS↗

Final Report: Development of a CW NCRF Photoinjector using Solid Freeform Fabrication

The development of very high duty cycle, high gradient photoinjectors is critical for the next generation of accelerator systems, such as X-ray free-electron lasers (FELs), inverse Compton scattering (ICS) sources, energy recovery linacs (ERLs), injectors for linear colliders, as well as a variety of industrial systems for homeland security applications. NCRF photoinjectors have a proven track record at generating the high-quality beams necessary for these applications, however they are limited in large part to relatively low duty cycles due to ohmic wall looses. Thus a key issue for high average power, normal conducting, photoinjectors is effective structure cooling [9]. The fabrication of current high average-power photoinjectors relies on conventional design and fabrication techniques with many limitations. Advances in Solid Freeform Fabrication (SFF) technology may make it possible to design and produce near net-shape copper structures for the next generation of very high rep rate, high gradient radio frequency (RF) photoinjectors. RF and thermal-management optimized geometries could be fully realized without the usual constraints and compromises of conventional machining techniques*. Further advances in SFF and powder metallurgy (P/M) techniques, with the ability to fine tune material properties, may soon make it possible to produce monolithic, thermally robust RF structures faster and cheaper than ever before.

Frigola, Pedro↗

Modeling Multi-Bunch X-band Photoinjector Challenges

An X-band test station is being developed at LLNL to investigate accelerator optimization for future upgrades to mono-energetic gamma-ray technology at LLNL. The test station will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. Of critical import to the functioning of the LLNL X-band system with multiple electron bunches is the performance of the photoinjector. In depth modeling of the Mark 1 LLNL/SLAC X-band rf photoinjector performance will be presented addressing important challenges that must be addressed in order to fabricate a multi-bunch Mark 2 photoinjector. Emittance performance is evaluated under different nominal electron bunch parameters using electrostatic codes such as PARMELA. Wake potential is analyzed using electromagnetic time domain simulations using the ACE3P code T3P. Plans for multi-bunch experiments and implementation of photoinjector advances for the Mark 2 design will also be discussed.

42 ENGINEERING↗

Photocathode Preparation System for the ALICE Photoinjector

ALICE--Accelerators and Lasers in Combined Experiments--is a relatively new accelerator built at Daresbury Laboratory that will demonstrate the process of energy recovery by the end of 2008. The project is a research facility to develop the technology required to build a New Light Source (NLS) in the UK. This paper details the current ALICE photoinjector design and highlights the limitations before focusing on a photoinjector upgrade. The key component of the upgrade is a three-stage extreme high vacuum load-lock system that will be incorporated into the ALICE photoinjector in 2010. The load-lock system has de facto become a standard component of a type III-V semiconductor photocathode injector and comprises: 1) loading chamber to allow new photocathodes to be introduced, 2) cleaning chamber for atomic hydrogen cleaning of the photocathodes and, 3) a preparation and activation chamber where the photocathodes will be activated to the NEA state ready for use on the ALICE accelerator. Once commissioned the load-lock system will allow rapid transfer of photocathodes between the load-lock system and the ALICE photoinjector whilst maintaining the integrity of the vacuum system and providing many other benefits. The new load-lock system will not only remove the problems with the existing set-up, it will also permit a new vacuum chamber to be designed for the gun itself. This new design will also aim to improve vacuum performance by addressing some of the major vacuum associated problems ALICE has encountered in the past 2 years.

43 PARTICLE ACCELERATORS↗

50 MW X-BAND RF SYSTEM FOR A PHOTOINJECTOR TEST STATION AT LLNL

In support of X-band photoinjector development efforts at LLNL, a 50 MW test station is being constructed to investigate structure and photocathode optimization for future upgrades. A SLAC XL-4 klystron capable of generating 50 MW, 1.5 microsecond pulses will be the high power RF source for the system. Timing of the laser pulse on the photocathode with the applied RF field places very stringent requirements on phase jitter and drift. To achieve these requirements, the klystron will be powered by a state of the art, solid-state, high voltage modulator. The 50 MW will be divided between the photoinjector and a traveling wave accelerator section. A high power phase shifter is located between the photoinjector and accelerator section to adjust the phasing of the electron bunches with respect to the accelerating field. A variable attenuator is included on the input of the photoinjector. The distribution system including the various x-band components is being designed and constructed. In this paper, we will present the design, layout, and status of the RF system.

42 ENGINEERING↗

Processing and Testing of the SRF Photoinjector Cavity for BERLinPro

The BERLinPro project is a compact, c.w. SRF energy recovery linac (ERL) that is being built to develop the accelerator physics and technology required to operate the next generation of high current ERLs. The machine is designed to produce a 50 MeV 100 mA beam, with better than 1 mm-mrad emittance. The electron source for the ERL will be a SRF photoinjector equipped with a multi-alkali photocathode. In order to produce a SRF photoinjector to operate reliably at this beam current HZB has undertaken a 3 stage photoinjector development program to study the operation of SRF photoinjectors in detail. The 1.4 cell cavity being reported on here is the second stage of this development, and represents the first cavity designed by HZB for use with a high quantum efficiency multi-alkali photocathode. This paper will describe the work done to prepare the cavity for RF testing in the vertical testing dewar at Jefferson Laboratory as well as the results of these RF tests.

Burrill, Andrew↗

An ultrafast laser pulse picker technique for high-average-current high-brightness photoinjectors

Beam diagnostics in high brightness photoinjectors requires that optical pulses from a high-power drive laser be picked up with an ultrahigh pulse contrast ratio and without temporal profile distortion. In high-average-current high-brightness photoinjectors, high-power drive lasers are routinely operated at GHz-level pulse repetition rate and it is challenging to achieve pulse picking without any pulse distortion. Here, we report on a new ultrafast pulse picker technique for beam diagnostics in high-average-current high-brightness photoinjectors. By efficiently combining an ultrafast low-power electro-optic modulator, high-power fiber laser amplifiers, a high-power Pockels Cell, and a frequency doubling module, we have successfully demonstrated optical bunch (30 pulses per bunch) pickup from a 704 MHz high-power drive laser and achieved a 10 6 :1 pulse contrast ratio and nearly zero pulse distortion. The performance of this pulse picking technique has been verified through beam characterization and electron cooling in the low energy RHIC electron cooling accelerator at Brookhaven National Laboratory.

43 PARTICLE ACCELERATORS↗

Improved Space Charge Modeling for Simulation and Design of Photoinjectors

Photoinjectors in advanced high-energy accelerators reduce beam energy spreads and enhance undulator photon fluxes. Photoinjector design is difficult because of the substantial differences in time and spatial scales. This Phase I program explored an innovative technique, the local Taylor polynomial (LTP) formulation, for improving finite difference analysis of photoinjectors. This included improved weighting techniques, systematic formula for high order interpolation and electric field computation, and improved handling of space charge. The Phase I program demonstrated that the approach was powerful, accurate, and efficient. It handles space charge gradients better than currently available technology.

43 PARTICLE ACCELERATORS↗

Development of a CW NCRF Photoinjector using Solid Freeform Fabrication (SFF)

A key issue for high average power, normal conducting radio frequency (NCRF), photoinjectors is efficient structure cooling. To that end, RadiaBeam has been developing the use of Solid Freeform Fabrication (SFF) for the production of NCRF photoinjectors. In this paper we describe the preliminary design, developed in collaboration with JLab, of a high gradient, very high duty cycle, photoinjector combining the cooling efficiency only possible through the use of SFF, and the RF efficiency of a re-entrant gun design. Simulations of the RF and thermal-stress performance are presented, as well as material testing of SFF components.

43 PARTICLE ACCELERATORS↗

Maximizing Brightness in Photoinjectors

If the laser pulse driving photoinjectors could be arbitrarily shaped, the emittance growth induced by space charge effects could be totally compensated for. In particular, for RF guns the photo-electron distribution leaving the cathode should have a 3D-ellipsoidal shape. The emittance at the end of the injector could be as small as the cathode emittance. We explore how the emittance and the brightness can be optimized for photoinjector based on RF gun depending on the peak current requirements. Techniques available to produce those ideal laser pulse shapes are also discussed. If the laser pulse driving photoinjectors could be arbitrarily shaped, the emittance growth induced by space charge effects could be totally compensated for. In particular, for RF guns, the photo-electron distribution leaving the cathode should be close to a uniform distribution contained in a 3D-ellipsoid contour. For photo-cathodes which have very fast emission times, and assuming a perfectly uniform emitting surface, this could be achieved by shaping the laser in a pulse of constant fluence and limited in space by a 3D-ellipsoid contour. Simulations show that in such conditions, with the standard linear emittance compensation, the emittance at the end of the photo-injector beamline approaches the minimum value imposed by the cathode emittance. Brightness, which is expressed as the ratio of peak current over the product of the two transverse emittance, seems to be maximized for small charges. Numerical simulations also show that for very high charge per bunch (10nC), emittances as small as 2 mm-mrad could be reached by using 3D-ellipsoidal laser pulses in an S-Band gun. The production of 3D-ellipsoidal pulses is very challenging, but seems worthwhile the effort. We briefly discuss some of the present ideas and difficulties of achieving such pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam dynamics simulations of the NML photoinjector at Fermilab

Fermilab is currently constructing a superconducting RF (SRF) test linear accelerator at the New Muon Lab (NML). Besides testing SRF accelerating modules for ILC and Project-X, NML will also eventually support a variety of advanced accelerator R&D experiments. The NML incorporates a 40 MeV photoinjector capable of providing electron bunches with variable parameters. The photoinjector is based on the 1+1/2 cell DESY-type gun followed by two superconducting cavities. It also includes a magnetic bunch compressor, a round-to-flat beam transformer and a low-energy experimental area for beam physics experiments and beam diagnostics R&D. In this paper, we explore, via beam dynamics simulations, the performance of the photoinjector for different operating scenarios.

43 PARTICLE ACCELERATORS↗

Comparison of multiobjective optimization methods for the $\mathrm{LCLS-II}$ photoinjector

Particle accelerators are among some of the largest science experiments in the world and can consist of thousands of components with a wide variety of input ranges. These systems can easily become unwieldy optimization problems during design and operations studies. Starting in the early 2000s, searching for better beam dynamics configurations became synonymous with heuristic optimization methods in the accelerator physics community. Genetic algorithms and particle swarm optimization are currently the most widely used. These algorithms can take thousands of simulation evaluations to find optimal solutions for one machine prototype. For large facilities such as the Linac Coherent Light Source (LCLS) and others, this equates to a limited exploration of many possible design configurations. In this paper, the LCLS-II photoinjector is optimized with three optimization algorithms. All optimizations were started from both a uniform random and Latin hypercube sample. In all cases, the optimizations started from Latin hypercube samples outperformed optimizations started from uniform samples. All three algorithms were able to optimize the photoinjector, with the model-based methods approximating the Pareto front in fewer simulation evaluations. This work, in combination with previous optimization observations, indicates objective penalties have a strong impact on the efficiency of such methods. In general, we recommend heuristic methods for initial optimizations and model-based methods when information about the objective space is available.

43 PARTICLE ACCELERATORS↗

Simulation study on the emittance compensation of off-axis emitted beam in RF photoinjector

To make full use of the photocathode material and improve its quantum efficiency lifetime, it can be necessary to operate the laser away from the cathode center in photoinjectors. In RF guns, the off-axis emitted beam will see a time-dependent RF effect, which would generate a significant growth in transverse emittance. It has been demonstrated that such an emittance growth can be almost completely compensated by orienting the beam on a proper orbit in the downstream RF cavities along the injector [1]. In this paper we analyze in detail the simulation techniques used in reference [1] and the issues associated with them. The optimization of photoinjector systems involving off-axis beams is a challenging problem. To solve this problem, one needs advanced simulation tools including both genetic algorithms and an efficient algorithm for 3D space charge. In this paper, we report on simulation studies where the two codes ASTRA and IMPACT-T are used jointly to overcome these challenges, in order to optimize a system designed to compensate for the emittance growth in a beam emitted off axis.

36 MATERIALS SCIENCE↗