Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phasor based control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and distributed components. In this report, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and ditributed components. In this paper, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

Baudette, Maxime↗

Phasor Based Control with the Distributed, Extensible Grid Control Platform

This paper describes how to implement Phasor Based Control (PBC) using the Distributed, Extensible Grid Control (DEGC) Platform. PBC is a novel method for controlling distributed energy resources (DER) that coordinates a centralized optimization with distributed feedback controllers to enforce voltage phasor targets. DEGC is an open source software and communication platform designed for general DER control. We deployed PBC at Lawrence Berkeley Lab's FLEXLAB test site, conducting multiple hardware-in-the-loop test runs. Here, we describe how DEGC was used to implement PBC on hardware, and results demonstrating successful deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗

Phasor-Based Control for Scalable Integration of Variable Energy Resources

We propose an innovative framework termed phasor-based control (PBC) to facilitate the integration of heterogeneous and intermittent distributed energy resources (DER) on the electric grid. PBC presents a unified approach that is agnostic to optimization criteria and to the particular characteristics of participating resources. It is enabled by synchronized, high-precision voltage phasor measurements that allow stating control objectives in grid-specific, rather than resource-specific, terms. We present qualitative justification and examine the general feasibility of this control approach, including the behavior of candidate control algorithms in simulation. Initial results suggest that PBC has significant potential to support stable and resilient grid operations in the presence of arbitrarily high penetrations of DER.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phasor-Based Control for Scalable Solar PV Integration (Final Technical Report)

This project demonstrated that solar PV can be recruited to stabilize the grid, smooth out disturbances, manage power flows, and assist circuit switching operations. It developed a radically new, layered control framework for Distributed Energy Resources (DER) to act in response to real-time, measured conditions on their local distribution circuit, rather than waiting for a price signal to indicate preferred behavior. By enabling resources to act as good citizens on the electric grid, Phasor-Based Control (PBC) facilitates arbitrarily high solar penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phasor-Based Control for Scalable Solar PV Integration

This project demonstrated that solar PV can be recruited to stabilize the grid, smooth out disturbances, manage power flows, and assist circuit switching operations. It developed a radically new, layered control framework for Distributed Energy Resources (DER) to act in response to real-time, measured conditions on their local distribution circuit, rather than waiting for a price signal to indicate preferred behavior. By enabling resources to act as good citizens on the electric grid, Phasor-Based Control (PBC) facilitates arbitrarily high solar penetration levels.

14 SOLAR ENERGY↗

An Extensible Software and Communication Platform for Distributed Energy Resource Management

This paper introduces a novel Distributed Extensible Grid Control (DEGC) software and communication platform to facilitate the control of distributed energy resources on electric grids. The DEGC software platform leverages state-of-the-art advances in secure, distributed communication and decentralized authorization and authentication. We discuss how these advances enable the kind of robust and secure communication required for a distributed grid control platform, and show how DEGC applies these technologies to the agile development and deployment of grid software through an extensible and flexible API. Here, we describe how DEGC can implement both Volt-VAR voltage magnitude control and Phasor-Based Control as sample applications and demonstrate the DEGC platform in hardware with the demanding Phasor-Based Control test case, and provide performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phasor-Based Adaptive Control of a Test-Feeder Distribution Network

Control in the power distribution system is needed to match the generation of electricity (that is, supply) with the demand for power (that is, load) at all times while maintaining a high level of power quality [1] (see "Summary"). The complexity of controlling the electric distribution system increases when distributed intermittent energy sources, such as solar photovoltaics (PVs), displace large-scale dispatchable generation [2]-[10]. Furthermore, if the supply from distributed resources exceeds the time-varying demand across a feeder, then the feeder-level voltage will increase. In extreme cases, large voltage increases will trigger the disconnection of distributed generation to protect electrical equipment and ensure customer safety. Consequently, coordinating renewable energy sources that are distributed throughout the distribution system-to match real-time demand across an entire power network-brings the additional challenge of maintaining a high level of supply reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Iterative Linearization for Phasor-Defined Optimal Power Dispatch

Optimal power flow (OPF) problems, which dispatch power targets to controllable generating units across a network, must generally account for non-convex constraints on power flow. Furthermore, adapting those problems so as to make them solvable with convex optimization techniques is an area of much academic and operational interest. In this paper, we present a method for solving OPF as a quadratic program by iteratively refining and re-initializing a linearized model of power flow based on the outputs of an associated nonlinear solver. The linear model on which we demonstrate this method is an adapted version of an approximation designed for use with unbalanced distribution networks. As an important benefit, the model allows for the explicit inclusion of nodal voltage phasor values in both the OPF problem's objective and its constraints, which opens the door to the idea of phasor-based control (PBC) design. We show in simulations on the IEEE 13-node test feeder that our method quickly converges to a set of phasor targets that are sufficiently precise for use in operations at the distribution level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronized Phasor Measurement Unit-based Central Controller for Normal and Contingent Operation of a High-Capacity HVDC Macrogrid for the Continental US

This paper presents a Synchronized Phasor Measurement Unit (PMU) based controller to support the coordination and operation of a high-capacity high-voltage direct current (HVDC) macrogrid transmission for the continental US. The proposed controller allows for optimal scheduling of each segment of the multi-terminal HVDC network under normal and contingent conditions, while considering minimum levels of frequency response requirements. The performance of the proposed controller is tested on a 100,222-bus representation of the US Eastern and Western interconnections. Results show that a centralized PMU-based controller improves the frequency nadir of the HVDC macrogrid under contingency conditions by 25.9%. Furthermore, the primary frequency response (PFR) of the HVDC macrogrid is increased by 33.4%. The performance of each interconnection under the largest credible contingency conditions is also discussed.

Mohan, Nihal↗

Universal Wide-area Damping Control for Mitigating Inter-area Oscillations in Power Systems

The active damping of inter-area oscillations of low frequencies has been successfully demonstrated to improve the dynamic response of the power grid in a satisfactory manner. It also enhances the system stability and reliability as well. The existence of inter-area oscillations has already become one of the key challenges in large-scale interconnected power grids because they are detrimental to the achievement of maximum power transfer and optimal power flow. This project focuses on the development of a universal damping control based on phasor measurements so that it can be easily implemented by a mix of various fast-acting resources to effectively mitigate inter-area oscillations. With the proposed advanced damping control strategies, the power grid stability and reliability can be managed in a much more flexible manner by utilizing different resources that are geographically dispersed in both the transmission and distribution systems. Moreover, higher power transfer capacity can be also achieved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fast Load Control System Based on Mobile Distribution-Level Phasor Measurement Unit

The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of our work is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel Mobile Distribution-level Phasor Measurement Unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the Rate Of Change Of Frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also examined. Finally, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Electromagnetic Transient and Phasor-based Simulation for the Stability of Grid-Forming-Inverter-based Microgrids

The increasing interest in studying feeder-level, inverter-based microgrids requires appropriate simulation methods that can effectively simulate the dynamics of distribution feeders that typically have thousands of nodes. To examine the accuracy of phasor-based simulation for the stability of feeder-level, inverter-based microgrids, a comparative study between electromagnetic transient (EMT) and phasor-based simulation was conducted. Case studies of a two-inverter small microgrid and a modified version of the IEEE 34-Node Test System that has seven grid-forming inverters show that phasor-based simulation agrees well with EMT simulation when the P-f droop gains of grid-forming inverter controllers are within normal ranges. However, under extremely high P-f droop gains, phasor-based simulation can result in over-optimistic stability results. This study provides insight into the applicability of phasor-based simulation for the stability of feeder-level, inverter-based microgrids.

Du, Wei↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗