Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase-contrast tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dynamic in situ imaging of methane hydrate formation in coal media

Fast 3D X-ray imaging has proved to provide crucial insights into multi-phase dynamic processes in various geomaterials. In particular, many in situ imaging experiments have been made to study gas-hydrate formation in porous sandy samples. Such imaging is challenging for the methane gas-hydrate formation in coal samples because of the coal micro-porosity structure and lower X-ray contrast. Here we present results of the first dynamic in situ micro-computed tomography experiment of methane-hydrate formation in coal samples. Synchrotron phase-contrast tomography techniques allowed to achieve necessary contrast levels to separate all the materials of interest (gas, water, coal, and gas hydrate) in reconstructed images with high spatial and temporal resolution. The imaging results are compared to the ones from a similar tomographic experiment with sand samples. Methane-hydrate formation is accompanied by the water movements caused by cryogenic water suction that happens in sequences of short fast movements with longer equilibrium states in between. Only one type of the hydrate formation was observed in coal (growth as shells on grain boundaries) as opposed to three types in sand (shells, growth into gas pockets, and inside water volumes). In particular, this leads to a slower hydrateformation speed in coal. For the coal sample, we also observed water extraction from grains, and interpreted it as competitive sorption of methane. Lastly, we visualized the dynamic behavior of this water extraction via microchannels inside the coal grains, and performed nano-tomography imaging of these channels for a better understanding of this phenomenon.

58 GEOSCIENCES↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE↗

High-resolution multicontrast tomography with an X-ray microarray anode–structured target source

Multicontrast X-ray imaging with high resolution and sensitivity using Talbot–Lau interferometry (TLI) offers unique imaging capabilities that are important to a wide range of applications, including the study of morphological features with different physical properties in biological specimens. The conventional X-ray TLI approach relies on an absorption grating to create an array of micrometer-sized X-ray sources, posing numerous limitations, including technical challenges associated with grating fabrication for high-energy operations. We overcome these limitations by developing a TLI system with a microarray anode–structured target (MAAST) source. The MAAST features an array of precisely controlled microstructured metal inserts embedded in a diamond substrate. Using this TLI system, tomography of a Drum fish tooth with high resolution and tri-contrast (absorption, phase, and scattering) reveals useful complementary structural information that is inaccessible otherwise. The results highlight the exceptional capability of high-resolution multicontrast X-ray tomography empowered by the MAAST-based TLI method in biomedical applications.

47 OTHER INSTRUMENTATION↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Synchrotron micro-computed tomography analysis of neutron-irradiated U-Mo fuel

The three-dimensional (3D) microstructure of neutron-irradiated uranium-10 wt.% molybdenum (U-10Mo) fuel with a burn-up of 9.8 × 10 21 fissions/cm 3 was characterized using a novel, multi-modal synchrotron micro-computed tomography approach combining propagation-based phase-contrast enhanced and absorption contrast techniques. The porosity development, porosity interconnectedness, swelling, composition, local thickness of the zirconium (Zr) diffusion barrier, and the influence of the fuel–cladding interaction on the local composition and pore morphology, were uniquely determined in 3D. Two cuboids were produced using a focused ion beam-scanning electron microscope at the Zr diffusion barrier–fuel interface and in the bulk fuel. The bulk fuel sample swelled by 53.3 [+9.7/−3.1]%, while the fuel near the Zr–fuel interface swelled by 63.3 [+14.7/−7.2]%. The average local thickness of the Zr diffusion barrier decreased by 53 %, compared to the expected pre-irradiated thickness. Four pore morphology regions were identified initiating parallel to the fuel–Zr interaction region: (1) an interaction layer of suppressed porosity, (2) a layer of elongated and interconnected porosity, (3) a transition zone of low porosity, and (4) a layer of unoriented porosity representative of the bulk fuel behavior. The increase in porosity near the diffusion barrier corresponded to a higher U concentration compared to that in the bulk fuel. The interconnected porosity in the fuel near the diffusion barrier was extensive and oriented parallel to the diffusion barrier, while the bulk fuel had more compact and isolated pore networks. The interaction layer, despite having suppressed porosity, was nearly 100 wt.% U. Porosity suppression at the diffusion barrier corresponds to the expected reduction in radiation-driven diffusion of Xe at the interface despite the anticipated increase in fission product nucleation originating from a higher U concentration. In conclusion, the novel 3D insights of the porosity, swelling, and compositional variations characterized herein can improve the fidelity of fuel performance codes for proliferation-resistant fuels for research and test reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Biomechanical drivers of the evolution of butterflies and moths with a coilable proboscis

Current biomechanical models suggest that butterflies and moths use their proboscis as a drinking straw pulling nectar as a continuous liquid column. Our analyses revealed an alternative mode for fluid uptake: drinking bubble trains that help defeat drag. We combined X-ray phase-contrast imaging, optical video microscopy, micro-computed tomography, phylogenetic models of evolution and fluid mechanics models of bubble-train formation to understand the biomechanics of butterfly and moth feeding. Our models suggest that the bubble-train mechanism appeared in the early evolution of butterflies and moths with a proboscis long enough to coil. We propose that, in addition to the ability to drink a continuous column of fluid from pools, the ability to exploit fluid films by capitalizing on bubble trains would have expanded the range of available food sources, facilitating diversification of Lepidoptera.

Palaoro, Alexandre V.↗

Solving complex nanostructures with ptychographic atomic electron tomography

Abstract Transmission electron microscopy (TEM) is essential for determining atomic scale structures in structural biology and materials science. In structural biology, three-dimensional structures of proteins are routinely determined from thousands of identical particles using phase-contrast TEM. In materials science, three-dimensional atomic structures of complex nanomaterials have been determined using atomic electron tomography (AET). However, neither of these methods can determine the three-dimensional atomic structure of heterogeneous nanomaterials containing light elements. Here, we perform ptychographic electron tomography from 34.5 million diffraction patterns to reconstruct an atomic resolution tilt series of a double wall-carbon nanotube (DW-CNT) encapsulating a complex ZrTe sandwich structure. Class averaging the resulting tilt series images and subpixel localization of the atomic peaks reveals a Zr 11 Te 50 structure containing a previously unobserved ZrTe 2 phase in the core. The experimental realization of atomic resolution ptychographic electron tomography will allow for the structural determination of a wide range of beam-sensitive nanomaterials containing light elements.

36 MATERIALS SCIENCE↗

TomoTwin: A simple digital twin for synchrotron tomography

A digital twin for synchrotron-based tomography for generating synthetic datasets from ground-truth phantoms. The code outputs greyscale projection images / tomographic volumes with realistic artifacts such as noise and phase-contrast and emulates their dependence on the acquisition parameters defining the beam and detector configuration. Some ground-truth phantoms are included with the code.

TEKAWADE, ANIKET↗

Quantifying particle-scale 3D granular dynamics during rapid compaction from time-resolved in situ 2D x-ray images

Understanding the particle-scale dynamics of granular materials during rapid compaction and flow is of fundamental importance for manufacturing, planetary science, geology, and defense applications. Time-resolved 2D radiography and static 3D x-ray tomography are powerful in situ tools for studying particle-scale dynamics but provide detail only in 2D or with significant time-scale limitations, respectively. Here, we introduce a new method that uses 2D in situ x-ray imaging for determining time-resolved 3D particle-scale dynamics in rapidly compressed granular materials. The method employs initial particle packing structures obtained from x-ray tomography, a 2D x-ray image generation algorithm, and an optimization algorithm. We first describe and validate the method using finite element simulations. Furthermore, we then apply the technique to x-ray phase-contrast images obtained during rapid compaction of granular materials with varying particle morphology and sample thickness. The depth-resolved particle-scale dynamics reveal complex velocity and porosity fields evolving heterogeneously along and perpendicular to the compaction direction. We characterize these features, their fluctuations near the compaction front, and the compaction front thickness. Our technique can be applied to understanding granular dynamics during rapid compaction events, and rearrangements during slower, but non-quasi-static, flows.

36 MATERIALS SCIENCE↗

High-speed synchrotron X-ray phase-contrast imaging for evaluating microscale damage mechanisms and tracking cracking behaviors inside cross-ply GFRCs

In this study, we integrated the high-speed synchrotron X-ray phase-contrast imaging (PCI) with a modified Kolsky compression bar loading platform to visualize the dynamic failure processes of cross-ply glass fiber reinforced composites (GFRCs). Four S-2 glass/SC-15 composite specimens were prepared, having similar thicknesses but different stacking sequences, namely as [0 12 /90 12 ], [90 12 /0 12 ], [0 8 /90 8 /0 8 ], and [90 8 /0 8 /90 8 ]. Three-dimensional synchrotron X-ray computed tomography and scanning electron microscopy (SEM) were employed to examine the microstructures and quantify the fiber volume fractions. Each specimen was notched and subjected to a dynamic three-point flexural loading. The onset of cracking close to the notch tip, crack propagation in 0° or 90° plies and their interface, crack opening, and ultimately failure of the specimen were captured by high-speed synchrotron X-ray PCI. Additional dynamic experiments were performed to determine the average time when the stress wave propagated through the specimen and correlate the X-ray images with the specimen's force-deflection response. Finally, the surface morphology of each specimen after the dynamic loading was imaged by SEM. Comparison between real-time X-ray images and post-fracture SEM images demonstrated the capability of the X-ray method to record damage evolution inside composites. Furthermore, the high spatial and temporal resolutions of the X-ray setup and edge enhancement by PCI enabled the identification of microscale damage features within 1 μs. Two damaging processes were identified, crack growth was quantified, and fracture toughness of the composites was evaluated. The method is deemed useful to reveal microscale damage mechanisms and track cracking behaviors inside cross-ply GFRCs under dynamic loading in real time.

42 ENGINEERING↗

Single-distance nano-holotomography with coded apertures

High-resolution phase-contrast 3D imaging using nano-holotomography typically requires collecting multiple tomograms at varying sample-to-detector distances, usually 3 to 4. This multi-distance approach limits temporal resolution, making it impractical for operando studies. Moreover, shifting the sample complicates reconstruction, requiring precise alignment, registration, and interpolation to correct for shift-dependent magnification on the detector. In response, we propose and validate through simulations a novel, to the best of our knowledge, single-distance approach that leverages coded apertures to structure beam illumination while the sample rotates. Finally, this approach relies on a joint reconstruction scheme, which integrates phase retrieval with 3D tomography, ensuring data consistency and achieving artifact-free reconstructions from a single distance, unlocking dynamic experiments.

Nikitin, Viktor [Argonne National Laboratory (ANL)↗

Nondestructive Evaluation of Advanced Materials with X-ray Phase Mapping

X-ray radiation has been widely used for imaging applications since Rontgen first discovered X-rays over a century ago. Its large penetration depth makes it ideal for the nondestructive visualization of the internal structure and/or defects of materials unobtainable otherwise. Currently used nondestructive evaluation (NDE) tools, X-ray radiography and tomography, are absorption-based, and work well in heavy-element materials where density or composition variations due to internal structure or defects are high enough to produce appreciable absorption contrast. However, in many cases where materials are light-weight and/or composites that have similar mass absorption coefficients, the conventional absorption-based X-ray methods for NDE become less useful. Indeed, the light-weight and ultra-high-strength requirements for the most advanced materials used or developed for current flight mission and future space exploration pose a great challenge to the standard NDE tools in that the absorption contrast arising from the internal structure of these materials is often too weak to be resolved. In this presentation, a solution to the problem, the use of phase information of X-rays for phase contrast X-ray imaging, will be discussed, along with a comparison between the absorption-based and phase-contrast imaging methods. Latest results on phase contrast X-ray imaging of lightweight Space Shuttle foam in 2D and 3D will be presented, demonstrating new opportunities to solve the challenging issues encountered in advanced materials development and processing.

Hu, Zhengwei↗