Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “personal protective equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation and optimization for the decontamination/sterilization of personal protective equipment using a novel ozone chamber (CRADA Final Report)

Personal protective equipment slows the spread of the SARS-Cov-2 virus and protects first responders and the general population. However, there is a significant and well-publicized shortage of personal protective equipment for healthcare workers. Treatment with ozone may be a compelling, affordable, and scalable method to rapidly decontaminate personal protective equipment but more work is needed to verify these claims. Together with colleagues at the University of Nevada Reno and FATHHOME we helped design the experiments that evaluated the virucidal efficacy of FATHHOME’s device on N95 face masks and face shields. The results of our study were published in the journal Pathogens.

60 APPLIED LIFE SCIENCES↗

Opinion to address the personal protective equipment shortage in the global community during the COVID-19 outbreak

The current COVID-19 pandemic is stretching both the global supply for face masks and personal protective equipment (PPE). Production capacity is severely limited in many countries. This is a call for the R&D community, particularly to those in the polymer degradation and stability field. We have not only an opportunity but an obligation to engage and collaborate with virology and bio-medical experts. We require comparative R&D for extended, reuse and recyclability options. Additionally, there is urgent need for large scale institutional approaches and methods that can be quickly applied locally by non-experts with limited resources.

36 MATERIALS SCIENCE↗

Observations Regarding Commonly Available Materials for Face Shield Emulated-Personal Protective Equipment

The Center for Disease Control has recommended that to reduce potential exposure to COVID-19 the public should wear cloth face coverings in public settings where other social distancing measures are difficult to maintain. These face coverings and other Emulated-Personal Protective Equipment (E-PPE) can be made by using Commonly Available Materials (CAMs). As E-PPE recommendations continue to flood the media, a Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated E-PPE design options considering their effectiveness, durability, build difficulty, build cost, and comfort. Using qualitative and semi-quantitative evaluation tools, results of the investigation are presented here to provide guidelines for home and office construction of E-PPE.

36 MATERIALS SCIENCE↗

Observations Regarding Commonly Available Materials for Face Covering Emulated-Personal Protective Equipment

The Center for Disease Control has recommended that to reduce potential exposure to COVID-19 the public should wear cloth face coverings in public settings where other social distancing measures are difficult to maintain. These face coverings and other Emulated-Personal Protective Equipment (E-PPE) can be made by using Commonly Available Materials (CAMs). As E-PPE recommendations continue to flood the media, a Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated E-PPE design options considering their effectiveness, durability, build difficulty, build cost, and comfort. Using qualitative and semi-quantitative evaluation tools, results of the investigation are presented here to provide guidelines for home and office construction of E-PPE.

36 MATERIALS SCIENCE↗

Durable Super-Repellant Materials for Stretchable and Flexible Personal Protective Equipment

The goal of this report is to summarize findings from development of new flexible protective coatings with superhydrophobic properties. For many practical applications, the durability of such coatings must far exceed what it currently possible. We aimed to develop coatings that can be integrated into personal protective equipment to provide an additional barrier that can shed and reduce the spread of infectious liquids. The COVID-19 pandemic has revealed the importance of PPE for frontline healthcare workers. Developing durable protective coatings could have both immediate impacts during the pandemic and long-term benefits in multiple industries.

36 MATERIALS SCIENCE↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Sandia's Research in Support of COVID-19 Pandemic Response: Materials Science

Sandia Materials Science Investment Area contributed to the SARS-CoV-2 virus and COVID-19 disease which represent the most significant pandemic threat in over 100 years. We completed a series of 7, short duration projects to provide innovative materials science research and development in analytical techniques to aid the neutralization of COVID-19 on multiple surfaces, approaches to rapidly decontaminate personal protective equipment, and pareto assessment of construction materials for manufacturing personal protective equipment. The developed capabilities and processes through this research can help US medical personnel, government installations and assets, first responders, state and local governments, and multiple federal agencies address the COVID-19 Pandemic.

36 MATERIALS SCIENCE↗

Lessons Learned—Fluoride Exposure and Response

Laboratory research can expose workers to a wide variety of chemical hazards. Researchers must not only take personal responsibility for their safety but also inevitably rely on coworkers to also work safely. The foundations for protocols, requirements, and behaviors come from our history and lessons learned from others. For that reason, here, a recent incident is examined in which a researcher suffered hydrofluoric acid (HF) burns while working with an inorganic digestion mixture of aqueous HF (8%) and nitric acid (HNO 3 , 58%). HF education is critical for workers because delays in treatment, improper treatment, and delay of symptoms are all factors in unfavorable outcomes in case reports. Furthermore, while the potential severity of the incident was elevated due to bypassed engineered controls and lack of proper personal protective equipment, only minor injuries were sustained. We discuss the results of a causal analysis of the incident that revealed areas of improvement in protocols, personal protective equipment, and emergency response that could help prevent similar accidents from occurring. We also present simple improvements that anyone can implement to reduce the potential consequences of an accident, based upon our lessons learned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Datasets and U-Net Model for "A Deep Learning Based Framework to Identify Undocumented Orphaned Oil and Gas Wells from Historical Maps: a Case Study for California and Oklahoma"

This dataset has results and the model associated with the publication Ciulla et al., (2024). It contains a U-Net semantic segmentation model (unet_model.h5) and associated code implemented in tensorflow 2.0 for the model training and identification of oil and gas well symbols in USGS historical topographic maps (HTMC). Given a quadrangle map (7.5 minutes), downloadable at this url: https://ngmdb.usgs.gov/topoview/, and a list of coordinates of the documented wells present in the area, the model returns the coordinates of oil and gas symbols in the HTMC maps. For reproducibility of our workflow, we provide a sample map in California and the documented well locations for the entire State of California (CalGEM_AllWells_20231128.csv) downloaded from https://www.conservation.ca.gov/calgem/maps/Pages/GISMapping2.aspx. Additionally, the locations of 1,301 potential undocumented orphaned wells identified using our deep learning framework or the counties of Los Angeles and Kern in California, and Osage and Oklahoma in Oklahoma are provided in the file found_potential_UOWs.zip. The results of the visual inspection of satellite imagery in Osage County is in the file visible_potential_UOWs.zip. The dataset also includes a custom tool to validate the detected symbols in the HTMC maps (vetting_tool.py). More details about the methodology can be found in the associated paper: Ciulla, F., Santos, A., Jordan, P., Kneafsey, T., Biraud, S.C., and Varadharajan, C. (2024) A Deep Learning Based Framework to Identify Undocumented Orphaned Oil and Gas Wells from Historical Maps: a Case Study for California and Oklahoma. Accepted for publication in Environmental Science and Technology. The geographical coordinates provided correspond to the locations of potential undocumented orphaned oil and gas wells (UOWs) extracted from historical maps. The actual presence of wells need to be confirmed with on-the-ground investigations. For your safety, do not attempt to visit or investigate these sites without appropriate safety training, proper equipment, and authorization from local authorities. Approaching these well sites without proper personal protective equipment (PPE) may pose significant health and safety risks. Oil and gas wells can emit hazardous gasses including methane, which is flammable, odorless and colorless, as well as hydrogen sulfide, which can be fatal even at low concentrations. Additionally, there may be unstable ground near the wellhead that may collapse around the wellbore. This dataset was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor the Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by its trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or the Regents of the University of California. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof or the Regents of the University of California.

Artificial Intelligence↗

Extended use of face masks during the COVID-19 pandemic - Thermal conditioning and spray-on surface disinfection

The current COVID-19 pandemic has resulted in globally constrained supplies for face masks and personal protective equipment (PPE). Production capacity is limited in many countries and the future course of the pandemic will likely continue with shortages for high quality masks and PPE in the foreseeable future. Therefore, expectations are that mask reuse, extended wear and similar approaches will enhance the availability of personal protective measures. Repeated thermal disinfection could be an important option and likely easier implemented in some situations, at least on the small scale, than UV illumination, irradiation or hydrogen peroxide vapor exposure. In this paper, an overview on thermal responses and ongoing filtration performance of multiple face mask types is provided. Most masks have adequate material properties to survive a few cycles (i.e. 30 min disinfection steps) of thermal exposure in the 75°C regime. Some are more easily affected, as seen by the fusing of plastic liner or warping, given that preferred conditioning temperatures are near the softening point for some of the plastics and fibers used in these masks. Hence adequate temperature control is equally important. As guidance, disinfectants sprayed via dilute solutions maintain a surface presence over extended time at 25 and 37°C. Some spray-on alcohol-based solutions containing disinfectants were gently applied to the top surface of masks. Neither moderate thermal aging (less than 24 h at 80 and 95°C) nor gentle application of surface disinfectant sprays resulted in measurable loss of mask filter performance. Subject to bio-medical concurrence (additional checks for virus kill efficiency) and the use of low risk non-toxic disinfectants, such strategies, either individually or combined, by offering additional anti-viral properties or short term refreshing, may complement reuse options of professional masks or the now ubiquitous custom-made face masks with their often unknown filtration effectiveness.

36 MATERIALS SCIENCE↗

Face mask integrated with flexible and wearable manganite oxide respiration sensor

Face masks are key personal protective equipment for reducing exposure to viruses and other environmental hazards such as air pollution. Integrating flexible and wearable sensors into face masks can provide valuable insights into personal and public health. The advantages that a breath-monitoring face mask requires, including multi-functional sensing ability and continuous, long-term dynamic breathing process monitoring, have been underdeveloped to date. Here, we design an effective human breath monitoring face mask based on a flexible La 0.7 Sr 0.3 MnO 3 (LSMO)/Mica respiration sensor. The sensor’s capabilities and systematic measurements are investigated under two application scenes, namely clinical monitoring mode and daily monitoring mode, to monitor, recognise, and analyse different human breath status, i.e., cough, normal breath, and deep breath. This sensing system exhibits super-stability and multi-modal capabilities in continuous and long-time monitoring of the human breath. We determine that during monitoring human breath, thermal diffusion in LSMO is responsible for the change of resistance in flexible LSMO/Mica sensor. Both simulated and experimental results demonstrate good discernibility of the flexible LSMO/Mica sensor operating at different breath status. Our work opens a route for the design of novel flexible and wearable electronic devices.

36 MATERIALS SCIENCE↗

Inactivation of Human Coronavirus by FATHHOME’s Dry Sanitizer Device: Rapid and Eco-Friendly Ozone-Based Disinfection of SARS-CoV-2

The pandemic of SARS-CoV-2/COVID-19 was reported in December 2019 in Wuhan, China. Pertaining to its high transmissibility and wide host adaptability, this unique human coronavirus spread across the planet inflicting 115 million people and causing 2.5 million deaths (as of March 3rd, 2021). Limited or negligible pre-existing immunity to multiple SARS-CoV-2 variants has resulted in severe morbidity and mortality worldwide, as well as a record-breaking surge in the use of medical-surgical supplies and personal protective equipment. In response to the global need for effective sterilization techniques, this study evaluated the virucidal efficacy of FATHHOME’s self-contained, ozone-based dry-sanitizing device, by dose and time response assessment. We tested inactivation of human coronavirus, HCoV-OC43, a close genetic model of SARS-CoV-2, on porous (N95 filtering facepiece respirator/FFR) and nonporous (glass) surfaces. We started our assays with 20 ppm-10 min ozone exposure, and effectively reduced 99.8% and 99.9% of virus from glass and N95 FFR surfaces, respectively. Importantly, the virus was completely inactivated, below the detection limit (over 6-log10 reduction) with 25 ppm-15 min ozone exposure on both tested surfaces. As expected, a higher ozone exposure (50 ppm-10 min) resulted in faster inactivation of HCoV-OC43 with 100% inactivation from both the surfaces, with no residual ozone present after completion of the 5-min post exposure recapture cycle and no measurable increase in ambient ozone levels. These results confirmed that FATHHOME’s device is suitable for rapid decontamination of SARS-CoV-2- from worn items, frequently touched items, and PPE including N95 FFRs, face shields, and other personal items. View Full-Text

59 BASIC BIOLOGICAL SCIENCES↗

Nonlinear viscoelastic response of silicone additively manufactured direct ink write (DIW) foams under repetitive compression

To investigate dynamic fatigue behavior of foam in military protective applications, such as helmets, additively manufactured (AM) foams were compressively strained into the plateau region using a reduced design of experiments. A simple power law was found to govern the decline in dynamic stiffness (complex modulus) as the foams underwent the purchase order requirement of 10,000 cycles of small deformation in the plateau region. This rate of decline was newly found to correlate with the degree of nonlinearity in the material’s deformation, quantified using total harmonic distortion. Materials with low nonlinearity exhibited relatively stable stiffness across cycles, while those with high nonlinearity experienced greater losses. The observed nonlinearity depended on both applied stress and strain rate. A strong linear correlation (R 2 = 0.78) was identified between second-order nonlinearity and the time-dependent stiffness response. Two lattice structures were examined: face-centered tetragonal (FCT) and simple cubic (SC). The SC material exhibited higher total harmonic distortion (5%) and lower stiffness retention than the FCT (2%). In conclusion, these results suggest that for cyclic compression applications in a wide variety of industries such as packaging, personal protective equipment, or aerospace, selecting materials with lower stress and greater structural uniformity can enhance the stability of dynamic performance.

42 ENGINEERING↗

Benchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks

The onset of the 2019 novel coronavirus disease (COVID-19) led to a shortage of personal protective equipment (PPE), medical devices, and other medical supplies causing many stakeholders and the general public alike to turn to additive manufacturing (AM) as a stopgap when normally accessible devices were not available. However, without a method to test these AM constructs, there continued to be a disconnect between AM suppliers and the community’s needs. The objective of this study was to characterize the pressure drop and leakage of four different publicly available AM face mask models with two filter material combinations, as well as to investigate the impact of frame modification techniques including the use of foam strips and hot-water face forming to improve fit when the masks are donned on manikin head forms. AM face mask frame designs were downloaded from public repositories during the early stages of the COVID-19 pandemic. AM face masks were fabricated and tested on manikin head forms within a custom chamber containing dry aerosolized NaCl. Pressure drops, particle penetration, and leakage were evaluated for various flow rates and NaCl concentrations. Results indicated that filter material combination and frame modification played a major role in the overall performance of the AM face masks studied. Filter material combinations showed improved performance when high filtration fabric was used, and the cross-sectional area of the fabric was increased. AM frame modifications appeared to improve AM face mask leakage performance by as much as 69.6%.

36 MATERIALS SCIENCE↗

Inactivation of multiple human pathogens by Fathhome's dry sanitizer device: Rapid and eco-friendly ozone-based disinfection

SARS-CoV-2 spread rapidly, causing millions of deaths across the globe. As a result, demand for medical supplies and personal protective equipment (PPE) surged and supplies dwindled. Separate entirely, hospital-acquired infections have become commonplace and challenging to treat. To explore the potential of novel sterilization techniques, this study evaluated the disinfection efficacy of Fathhome's ozone-based, dry-sanitizing device by dose and time response. Inactivation of human pathogens was tested on non-porous (plastic) surfaces. 95.42-100% inactivation was observed across all types of vegetative microorganisms and 27.36% inactivation of bacterial endospores tested, with no residual ozone detectable after completion. These results strongly support the hypothesis that Fathhome's commercial implementation of gas-based disinfection is suitable for rapid decontamination of a wide variety of pathogens on PPE and other industrially relevant materials.

59 BASIC BIOLOGICAL SCIENCES↗

Household Materials Selection for Homemade Cloth Face Coverings and Their Filtration Efficiency Enhancement with Triboelectric Charging

The COVID-19 pandemic is currently causing a severe disruption and shortage in the global supply chain of necessary personal protective equipment (e.g., N95 respirators). The U.S. CDC has recommended use of household cloth by the general public to make cloth face coverings as a method of source control. We evaluated the filtration properties of natural and synthetic materials using a modified procedure for N95 respirator approval. Common fabrics of cotton, polyester, nylon, and silk had filtration efficiency of 5–25%, polypropylene spunbond had filtration efficiency 6–10%, and paper-based products had filtration efficiency of 10–20%. An advantage of polypropylene spunbond is that it can be simply triboelectrically charged to enhance the filtration efficiency (from 6 to >10%) without any increase in pressure (stable overnight and in humid environments). Using the filtration quality factor, fabric microstructure, and charging ability, we are able to provide an assessment of suggested fabric materials for homemade facial coverings.

36 MATERIALS SCIENCE↗

Three-Dimensional Analysis of Particle Distribution on Filter Layers inside N95 Respirators by Deep Learning

The global COVID-19 pandemic has changed many aspects of daily lives. Wearing personal protective equipment, especially respirators (face masks), has become common for both the public and medical professionals, proving to be effective in preventing spread of the virus. Nevertheless, a detailed understanding of respirator filtration-layer internal structures and their physical configurations is lacking. Here, we report three-dimensional (3D) internal analysis of N95 filtration layers via X-ray tomography. Using deep learning methods, we uncover how the distribution and diameters of fibers within these layers directly affect contaminant particle filtration. The average porosity of the filter layers is found to be 89.1%. Contaminants are more efficiently captured by denser fiber regions, with fibers <1.8 μm in diameter being particularly effective, presumably because of the stronger electric field gradient on smaller diameter fibers. This study provides critical information for further development of N95-type respirators that combine high efficiency with good breathability.

42 ENGINEERING↗