Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance time-multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Characterization and optimization of an eight-channel time-multiplexed pulse-shaping system

High-performance optical pulse shaping is paramount to photonics and lasers applications for which high-resolution optical waveforms must be generated. We investigate the design and performance of a time-multiplexed pulse shaping (TMPS) system in which optical waveforms from a single pulse-shaping unit are demultiplexed and retimed before being sent to different optical systems. This architecture has the advantages of low cost and low relative jitter between optical waveforms because a single pulse-shaping system, e.g., a high-performance arbitrary waveform generator driving a Mach-Zehnder modulator, generates all the waveforms. We demonstrate an eight-channel TMPS system based on a 1 × 8 LiNbO 3 demultiplexer composed of four stages of 1 × 2 Δβ phase-reversal switches that allow for demultiplexing and extinction enhancement via application of a control voltage modifying the propagation constant difference between adjacent waveguides. It is shown that optimal demultiplexing, i.e. low insertion loss and high extinction ratio between channels, requires optimization in dynamic operation because of the slow component of the switches’ response. Lastly, we demonstrate losses lower than 5 dB, extinction ratios of the order of 70 dB for a four-channel system and 50 dB for an eight-channel system, and jitter added by the demultiplexer smaller than 0.1 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially uniform resistance switching of low current, high endurance titanium–niobium-oxide memristors

Here we analyzed micrometer-scale titanium-niobium-oxide prototype memristors, which exhibited low write-power (< 3 μW) and energy (< 200 fJ per bit per μm 2 ), low read-power (~nW), and high endurance ( > millions of cycles). To understand their physico-chemical operating mechanisms, we performed in operando synchrotron X-ray transmission nanoscale spectromicroscopy using an ultra-sensitive time-multiplexed technique. We observed only spatially uniform material changes during cell operation, in sharp contrast to the frequently detected formation of a localized conduction channel in transition-metal-oxide memristors. We also associated the response of assigned spectral features distinctly to non-volatile storage (resistance change) and writing of information (application of voltage and Joule heating). Lastly, these results provide critical insights into high-performance memristors that will aid in device design, scaling and predictive circuit-modeling, all of which are essential for the widespread deployment of successful memristor applications.

36 MATERIALS SCIENCE↗

A Full Mesh ATCA-based General Purpose Data Processing Board (Pulsar II)

The Pulsar II is a custom ATCA full mesh enabled FPGA-based processor board which has been designed with the goal of creating a scalable architecture abundant in flexible, non-blocking, high bandwidth interconnections. The design has been motivated by silicon-based tracking trigger needs for LHC experiments. In this technical memo we describe the Pulsar II hardware and its performance, such as the performance test results with full mesh backplanes from different vendors, how the backplane is used for the development of low-latency time-multiplexed data transfer schemes and how the inter-shelf and intra-shelf synchronization works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-operando synchronous time-multiplexed O K-edge x-ray absorption spectromicroscopy of functioning tantalum oxide memristors

Memristors are receiving keen interest because of their potential varied applications and promising large-scale information storage capabilities. Tantalum oxide is a memristive material that has shown promise for high-performance nonvolatile computer memory. The microphysics has been elusive because of the small scale and subtle physical changes that accompany conductance switching. In this study, we probed the atomic composition, local chemistry, and electronic structure of functioning tantalum oxide memristors through spatially mapped O K-edge x-ray absorption. We developed a time-multiplexed spectromicroscopy technique to enhance the weak and possibly localized oxide modifications with spatial and spectral resolutions of <30 nm and 70 meV, respectively. During the initial stages of conductance switching of a micrometer sized crosspoint device, the spectral changes were uniform within the spatial resolution of our technique. When the device was further driven with millions of high voltage-pulse cycles, we observed lateral motion and separation of ∼100 nm-scale agglomerates of both oxygen interstitials and vacancies. We also demonstrate a unique capability of this technique by identifying the relaxation behavior in the material during electrical stimuli by identifying electric field driven changes with varying pulse widths. In addition, we show that changes to the material can be localized to a spatial region by modifying its topography or uniformity, as against spatially uniform changes observed here during memristive switching. The goal of this report is to introduce the capability of time-multiplexed x-ray spectromicroscopy in studying weak-signal transitions in inhomogeneous media through the example of the operation and temporal evolution of a memristor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters: Preprint

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗