Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance map”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗

TEAMER: Performance mapping of Re Vision's Persistance PTO

Contains datasets from experimental measurements that were used to validate Re Vision's Persistence PTO's efficiency and performance. These measurements were obtained using a dynamometer test bench setup. The data includes open-circuit voltage and loss measurements to validate machine characteristics, efficiency mapping tests to determine the generator's performance mapping, and efficiency mapping tests to determine the converter's efficiency over the feasible operating range. This data was collected between June 2023 and September 2023. The data was collected at the National Renewable Energy Laboratory's Flatirons Campus, Colorado, United States. The data was collected using NREL's 5-kW dynamometer test bench, equipped with a torque sensor and various voltage and current sensors fed to a dedicated data acquisition system. Units for the data are included in the data file headers for each data series. A text editor or spreadsheet software such as Excel is required to view the *.csv data. The data are also provided in *.mat files. To view data plots, a Matlab script with *.mat files are provided.

16 TIDAL AND WAVE POWER↗

Process–Property–Performance Mapping of Additively Manufactured 316H Stainless Steel Components

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development of advanced materials and components fabricated via additive manufacturing, and is using laser powder bed fusion (LPBF) of 316H stainless steel as an initial case study. In the previous fiscal year, miniature high-throughput specimens were printed on multiple LPBF systems to provide initial processing windows to minimize porosity and limit epitaxial grain growth during prints. This fiscal year, scaled builds were completed on three different LPBF systems at ORNL: a GE Concept Laser M2, a Renishaw AM400, and an EOS M290. Builds on the Concept Laser were conducted on multiple powder lots and processing parameter ranges to provide microstructure effects on time-independent and time-dependent mechanical properties. Builds on the Renishaw were produced using Oak Ridge National Laboratory (ORNL)-optimized printing parameters and Argonne National Laboratory (ANL)-optimized printing parameters to compare outcomes of parallel process optimization efforts at different national laboratories on the same LPBF system. Similarly, the build completed on the EOS M290 replicated the processing parameters of builds completed at Los Alamos National Laboratory (LANL). Optical microscopy and electron backscatter diffraction characterization was completed on all builds. In addition to the general round robin characterization, this work-package generated time-independent data, including tensile and fracture toughness test data on scaled Concept Laser builds as a function of processing parameters and post-build heat treatment. This analysis is complimentary to work in parallel work packages aiming to establish heat treatment and processing effects on time-dependent properties. It was found that although the stress-relief heat treatment provides the highest strength at lower-temperatures, tensile strength begins to converge at higher temperatures regardless of heat treatment condition. In addition, the more rigorous solution annealing and hot-isostatic pressing post-build heat treatments result in higher fracture toughness than the stress-relieved condition. The root-causes of the lower fracture toughness of the stress-relieved LPBF 316H material was informed via a stress-relief optimization study on a scaled concept laser print, where it was found that although dislocation recovery was largely complete after only a couple hours at 650°C, the extended hold of the current 24h heat treatment employed on scaled builds likely caused increased carbide volume fractions along the LPBF 316H grain boundaries, thereby deteriorating crack propagation resistance. This trend was seen to become more deleterious with additional increases of stress-relief temperature to 750°C or 850°C. These results have helped inform a new optimal stress-relief annealing condition for LPBF 316H for future campaign testing (650°C for 2h).

36 MATERIALS SCIENCE↗

Process–Property–Performance Mapping of Additively Manufactured 316H Stainless Steel Components

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development of advanced materials and components fabricated via additive manufacturing, and is using laser powder bed fusion (LPBF) of 316H stainless steel as an initial case study. In the previous fiscal year, miniature high-throughput specimens were printed on multiple LPBF systems to provide initial processing windows to minimize porosity and limit epitaxial grain growth during prints. This fiscal year, scaled builds were completed on three different LPBF systems at ORNL: a GE Concept Laser M2, a Renishaw AM400, and an EOS M290. Builds on the Concept Laser were conducted on multiple powder lots and processing parameter ranges to provide microstructure effects on time-independent and time-dependent mechanical properties. Builds on the Renishaw were produced using Oak Ridge National Laboratory (ORNL)-optimized printing parameters and Argonne National Laboratory (ANL)-optimized printing parameters to compare outcomes of parallel process optimization efforts at different national laboratories on the same LPBF system. Similarly, the build completed on the EOS M290 replicated the processing parameters of builds completed at Los Alamos National Laboratory (LANL). Optical microscopy and electron backscatter diffraction characterization was completed on all builds. In addition to the general round robin characterization, this work-package generated time-independent data, including tensile and fracture toughness test data on scaled Concept Laser builds as a function of processing parameters and post-build heat treatment. This analysis is complimentary to work in parallel work packages aiming to establish heat treatment and processing effects on time-dependent properties. It was found that although the stress-relief heat treatment provides the highest strength at lower-temperatures, tensile strength begins to converge at higher temperatures regardless of heat treatment condition. In addition, the more rigorous solution annealing and hot-isostatic pressing post-build heat treatments result in higher fracture toughness than the stress-relieved condition. The root-causes of the lower fracture toughness of the stress-relieved LPBF 316H material was informed via a stress-relief optimization study on a scaled concept laser print, where it was found that although dislocation recovery was largely complete after only a couple hours at 650°C, the extended hold of the current 24h heat treatment employed on scaled builds likely caused increased carbide volume fractions along the LPBF 316H grain boundaries, thereby deteriorating crack propagation resistance. This trend was seen to become more deleterious with additional increases of stress-relief temperature to 750°C or 850°C. These results have helped inform a new optimal stress-relief annealing condition for LPBF 316H for future campaign testing (650°C for 2h).

36 MATERIALS SCIENCE↗

Preliminary Safety Analysis for a 400-kW Molten Salt Nuclear Battery

The Molten Salt Nuclear battery (MsNB) is a microreactor based on technology developed and operated at Oak Ridge National Laboratory in the 1960s [1]. But the MsNB has been simplified by removing pumps and valves for improved reliability and safety. The MsNB can safely provide up to 10 MWe of power for up to 10 years and potentially it can be transported by air, truck, and rail thanks due to to its small footprint. A computer model has been developed to represent a prototypical 400-kW MsNB using the ANL system code SAM [2]. The model has been used to produce a reactor thermal-hydraulic performance map and perform analysis of unprotected loss of heat sink accident scenario.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine Learning of Performance Space Mapping for the DPD Simulation of Drug Delivery to Endothelial Cells

Despite huge effort over the years, the design of functionalised nanocarriers (NCs) for targeted drug delivery to endothelial cells is still to be completely unveiled. Dissipative particle dynamics (DPD) simulation is used to study the adhesion of NCs to endothelial cells under the influence of series of parameters such as shape, size, and ligand density of the NCs. However, preparing a performance space mapping that illustrates the penetration depths of NCs as a function of variations in their properties requires simulations of all possible NCs with the above-mentioned properties, which is not feasible. This challenge was addressed by leveraging a Gaussian process regression (GPR)-informed active learning strategy and an extensive exploration of numerous samples, each representing different properties of NCs. The performance space mapping reveals that NCs with rod and disc shapes exhibit superior penetration capabilities compared to those with a spherical shape. Furthermore, it demonstrates that smaller-sized rod-shaped NCs and larger-sized disc-shaped NCs tend to achieve better penetration. When considering smaller NCs, the influence of ligand density appears to be limited. On the contrary, for larger NCs, an increase in ligand density correlates with greater penetration depth, underscoring its substantial role in shaping their penetration capabilities.

36 MATERIALS SCIENCE↗

Radial Compressor Design and Off-Design for Trans-critical CO2 Operating Conditions

Presentation for the The 7th International Supercritical CO2 Power Cycles Symposium, February 21 – 24, 2022, San Antonio, Texas. A multi-staged intercooled centrifugal compressor design is performed for an indirect-fired sCO2 cycle and the design point data are used to generate the performance maps using a 2D mean-line analysis code. Fluid and turbomachinery similarity laws are applied to find an appropriate surrogate ideal gas fluid to be used in the design and performance map generation codes. The performance maps are then scaled back for the sCO2 fluid case using the affinity laws.

Uysal, Selcuk Can↗

Radial Compressor Design and Off-Design for Trans-critical CO2 Operating Conditions

A multi-staged intercooled centrifugal compressor design is performed for an indirect-fired sCO2 cycle and the design point data are used to generate the performance maps using a 2D mean-line analysis code. Fluid and turbomachinery similarity laws are applied to find an appropriate surrogate ideal gas fluid to be used in the design and performance map generation codes. The performance maps are then scaled back for the sCO2 fluid case using the affinity laws. The developed methodology is validated using the experimental data for a compressor operating at similar inflow conditions.

Uysal, Selcuk Can↗

Mapping the performance of a versatile water-based condensation particle counter (vWCPC) with numerical simulation and experimental study

Accurate airborne aerosol instrumentation is required to determine the spatial distribution of ambient aerosol particles, particularly when dealing with the complex vertical profiles and horizontal variations of atmospheric aerosols. A versatile water-based condensation particle counter (vWCPC) has been developed to provide aerosol concentration measurements under various environments with the advantage of reducing the health and safety concerns associated with using butanol or other chemicals as the working fluid. However, the airborne deployment of vWCPCs is relatively limited due to the lack of characterization of vWCPC performance at reduced pressures. Given the complex combinations of operating parameters in vWCPCs, modeling studies have advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flow vWCPC using COMSOL Multiphysics® simulation coupled with MATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI, Shoreview, MN, USA). Our simulation determined the performance of particle activation and droplet growth in the vWCPC growth tube, including the supersaturation, $D$ p,kel,0 (smallest size of particle that can be activated), $D$ p,kel,50 (particle size activated with 50 % efficiency) profile, and final growth particle size D d under wide operating temperatures, inlet pressures $P$ (30–101 kPa), and growth tube geometry (diameter $D$ and initiator length $L$ ini ). The effect of inlet pressure and conditioner temperature on vWCPC 3789 performance was also examined and compared with laboratory experiments. The COMSOL simulation result showed that increasing the temperature difference (Δ$T$) between conditioner temperature $T$ con and initiator $T$ ini will reduce $D$ p,kel,0 and the cut-off size $D$ p,kel,50 of the vWCPC. In addition, lowering the temperature midpoint ($T$ mid = $\frac{T_{con}+T_{ini}}{2}$ increases the supersaturation and slightly decreases the $D$ p,kel . The droplet size at the end of the growth tube is not significantly dependent on raising or lowering the temperature midpoint but significantly decreases at reduced inlet pressure, which indirectly alters the vWCPC empirical cut-off size. Our study shows that the current simulated growth tube geometry ($D$=6.3 mm and $L$ ini =30 mm) is an optimized choice for current vWCPC flow and temperature settings. The current simulation can more realistically represent the $D$ p,kel for 7 nm vWCPC and also achieved good agreement with the 2 nm setting. Using the new simulation approach, we provide an optimized operation setting for the 7 nm setting. This study will guide further vWCPC performance optimization for applications requiring precise particle detection and atmospheric aerosol monitoring.

47 OTHER INSTRUMENTATION↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Computationally efficient evaluation of optimum homogeneous charge compression ignition operating range with accelerated multizone engine cycle simulation

The very intensive calculations necessary to define a performance map requiring evaluation of over a hundred individual operating points can be efficiently conducted with accelerated multizone for engine cycle simulation, leading to a definition of regions of acceptable and optimum homogeneous charge compression ignition operation. Accelerated multizone for engine cycle simulation has the virtue of enabling accurate evaluation of many operating conditions based on thermal stratification data from a single fluid mechanics run at motored conditions. This is possible because thermal stratification is more sensitive to engine geometry than to operating conditions. In this article, accuracy of accelerated multizone for engine cycle simulation is demonstrated by comparison with experimental data for iso-octane homogeneous charge compression ignition operation over a broad range of lean equivalence ratios (0.14–0.28). The validated accelerated multizone for engine cycle simulation model is then applied to generating a performance map for an engine controlled by appropriately adjusting equivalence ratio and internal exhaust gas recirculation. Regions of acceptable and optimum combustion are identified. It is finally demonstrated that while indicated mean effective pressure remains low for optimum homogeneous charge compression ignition operation (1–4 bar), this is sufficient for a large fraction of typical driving in light-duty vehicles. Much driving including idle can therefore be done in homogeneous charge compression ignition mode at high efficiency and low (essentially zero) NOx and particulate matter emissions.

30 DIRECT ENERGY CONVERSION↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control↗

Compressor is A Sensor: A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The primary goal of this report is to develop a universal charge fault detection method that requires only a few experimental data with high prediction accuracy. Currently, pump-down operations is typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repair. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The new charge fault detection and diagnostics method innovatively utilizes the typical pump down operation, the compressor’s low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.

42 ENGINEERING↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ecological Insights from Transferable Plant Biomass Mapping across the Arctic using High-resolution Structure-from-Motion and LiDAR Data

Warmer temperatures, permafrost thaw, and increased wildfire activity are driving rapid ecological change across the Arctic, significantly altering plant productivity and aboveground biomass (AGB). These rapid changes highlight the urgent need to improve monitoring of vegetation dynamics in the Earth’s northern ecosystems, where high spatiotemporal heterogeneity occurs at scales finer than those captured by traditional satellite observations. The growing use of Unoccupied Aerial Systems (UASs) presents an opportunity to overcome this limitation. Yet, the diversity of UAS platforms, sensors, and data collection and processing workflows presents challenges for developing standardized, generalizable approaches. To address this challenge, we compiled 672 AGB plots co-located with 183 UAS-based Structure-from-Motion (SfM) or Light Detection and Ranging (LiDAR) surveys collected across the Arctic. Here, we: (1) evaluated the generalizability of UAS-derived canopy structure derived from high-resolution SfM and LiDAR for estimating AGB, (2) assessed scaling errors and their sources in two recent satellite-based AGB products derived from Landsat and MODIS, and (3) demonstrated the use of high-resolution AGB maps to quantify biomass variation across tundra plant functional types (PFTs) and to monitor post-fire recovery. Our results show that both SfM and LiDAR accurately captured AGB and its variability across tundra PFTs using a Random Forest (RF) model (overall RMSE: 0.336 kg/m2), with mapping performance varying slightly by region and data source. Using UAS-derived AGB maps as a benchmark, we identified systematic biases in satellite-derived AGB products, largely attributable to the magnitude of AGB and structural heterogeneity within coarse-resolution pixels. Applying our model to repeat UAS surveys following a tundra fire on Seward Peninsula, we observed rapid AGB recovery in non-shrub patches, with biomass recovering to pre-fire levels within 2 years. In contrast, shrub patches recovered more slowly, with AGB gains continuing over 2–4 years through both in-patch growth and lateral expansion (via dispersal) into remaining burned areas. Overall, these findings demonstrate the generalizability of UAS-based SfM and LiDAR data for estimating tundra AGB and highlight the potential of our approach to be broadly applied to generate high-quality AGB data for ecological monitoring and model benchmarking across the Arctic.

Yang, Daryl [ORNL] (ORCID:0000000317057823)↗