Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance map”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Computer controlled performance mapping of thermionic converters: effect of collector, guard-ring potential imbalances on the observed collector current-density, voltage characteristics and limited range performance map of an etched-rhenium, niobium planar converter

The effect of collector, guard-ring potential imbalance on the observed collector-current-density J, collector-to-emitter voltage V characteristic was evaluated in a planar, fixed-space, guard-ringed thermionic converter. The J,V characteristic was swept in a period of 15 msec by a variable load. A computerized data acquisition system recorded test parameters. The results indicate minimal distortion of the J,V curve in the power output quadrant for the nominal guard-ring circuit configuration. Considerable distortion, along with a lowering of the ignited-mode striking voltage, was observed for the configuration with the emitter shorted to the guard ring. A limited-range performance map of an etched-rhenium, niobium, planar converter was obtained by using an improved computer program for the data acquisition system.

Manista, E. J.↗

H2 arcjet performance mapping program

Work performed during the period of Mar. 1991 to Jan. 1992 is reviewed. High power H2 arcjets are being considered for electric powered orbit transfer vehicles (EOTV). Mission analyses indicate that the overall arcjet thrust efficiency is very important since increasing the efficiency increases the thrust, and thereby reduces the total trip time for the same power. For example, increasing the thrust efficiency at the same specific impulse from 30 to 40 percent will reduce the trip time by 25 percent. For a 200 day mission, this equates to 50 days, which results in lower ground costs and less time during which the payload is dormant. Arcjet performance levels of 1200 seconds specific impulse (lsp) at 35 to 40 percent efficiency with lifetimes over 1000 hours are needed to support EOTV missions. Because of the potential very high efficiency levels, the objective of this program was to evaluate the ability of a scaled Giannini-style thruster to achieve the performance levels while operating at a reduced nominal power of 10 kW. To meet this objective, a review of past literature was conducted; scaling relationships were developed and applied to establish critical dimensions; a development thruster was designed with the aid of the plasma analysis model KARNAC and finite element thermal modeling; test hardware was fabricated; and a series of performance tests were conducted in RRC's Cell 11 vacuum chamber with its null-balance thrust stand.

Source record↗

A Preliminary Foil Gas Bearing Performance Map

Recent breakthrough improvements in foil gas bearing load capacity, high temperature tribological coatings and computer based modeling have enabled the development of increasingly larger and more advanced Oil-Free Turbomachinery systems. Successful integration of foil gas bearings into turbomachinery requires a step wise approach that includes conceptual design and feasibility studies, bearing testing, and rotor testing prior to full scale system level demonstrations. Unfortunately, the current level of understanding of foil gas bearings and especially their tribological behavior is often insufficient to avoid developmental problems thereby hampering commercialization of new applications. In this paper, a new approach loosely based upon accepted hydrodynamic theory, is developed which results in a "Foil Gas Bearing Performance Map" to guide the integration process. This performance map, which resembles a Stribeck curve for bearing friction, is useful in describing bearing operating regimes, performance safety margins, the effects of load on performance and limiting factors for foil gas bearings.

DellaCorte, Christopher↗

Validation of ICESat-2 ATLAS Bathymetry and Analysis of ATLAS’s Bathymetric Mapping Performance

NASA’s Ice, Cloud, and Land Elevation Satellite-2 (ICESat-2) was launched in September, 2018. The satellite carries a single instrument, ATLAS (Advanced Topographic Laser Altimeter System), a green wavelength, photon-counting lidar, enabling global measurement and monitoring of elevation with a primary focus on the cryosphere. Although bathymetric mapping was not one of the design goals for ATLAS, pre-launch work by our research team showed the potential to map bathymetry with ICESat-2, using data from MABEL (Multiple Altimeter Beam Experimental Lidar), NASA’s high-altitude airborne ATLAS emulator, and adapting the laser-radar equation for ATLAS specific parameters. However, many of the sensor variables were only approximations, which limited a full assessment of the bathymetric mapping capabilities of ICESat-2 during pre-launch studies. Following the successful launch, preliminary analyses of the geolocated photon returns have been conducted for a number of coastal sites, revealing several salient examples of seafloor detection in water depths of up to ~40 m. The geolocated seafloor photon returns cannot be taken as bathymetric measurements, however, since the algorithm used to generate them is not designed to account for the refraction that occurs at the air–water interface or the corresponding change in the speed of light in the water column. This paper presents the first early on-orbit validation of ICESat-2 bathymetry and quantification of the bathymetric mapping performance of ATLAS using data acquired over St. Thomas, U.S. Virgin Islands. A refraction correction, developed and tested in this work, is applied, after which the ICESat-2 bathymetry is compared against high-accuracy airborne topo-bathymetric lidar reference data collected by the U.S. Geological Survey (USGS) and the National Oceanic and Atmospheric Administration (NOAA). The results show agreement to within 0.43—0.60 m root mean square error (RMSE) over 1 m grid resolution for these early on-orbit data. Refraction-corrected bottom return photons are then inspected for four coastal locations around the globe in relation to Visible Infrared Imaging Radiometer Suite (VIIRS) K(d)(490) data to empirically determine the maximum depth mapping capability of ATLAS as a function of water clarity. It is demonstrated that ATLAS has a maximum depth mapping capability of nearly 1 Secchi in depth for water depths up to 38 m and K(d)(490) in the range of 0.05–0.12 per m. Collectively, these results indicate the great potential for bathymetric mapping with ICESat-2, offering a promising new tool to assist in filling the global void in nearshore bathymetry.

ICESat-2↗

A Performance Map for Ideal Air Breathing Pulse Detonation Engines

The performance of an ideal, air breathing Pulse Detonation Engine is described in a manner that is useful for application studies (e.g., as a stand-alone, propulsion system, in combined cycles, or in hybrid turbomachinery cycles). It is shown that the Pulse Detonation Engine may be characterized by an averaged total pressure ratio, which is a unique function of the inlet temperature, the fraction of the inlet flow containing a reacting mixture, and the stoichiometry of the mixture. The inlet temperature and stoichiometry (equivalence ratio) may in turn be combined to form a nondimensional heat addition parameter. For each value of this parameter, the average total enthalpy ratio and total pressure ratio across the device are functions of only the reactant fill fraction. Performance over the entire operating envelope can thus be presented on a single plot of total pressure ratio versus total enthalpy ratio for families of the heat addition parameter. Total pressure ratios are derived from thrust calculations obtained from an experimentally validated, reactive Euler code capable of computing complete Pulse Detonation Engine limit cycles. Results are presented which demonstrate the utility of the described method for assessing performance of the Pulse Detonation Engine in several potential applications. Limitations and assumptions of the analysis are discussed. Details of the particular detonative cycle used for the computations are described.

Paxson, Daniel E.↗

Calculated performance map of a 4 1/2-stage 15.0 centimeter (5.9 inch) mean diameter turbine designed for a turbofan simulator

The overall performance of an existing high-ratio turbine is calculated analytically over a range of speed and pressure ratio in order to determine its capability for other applications. The analytical performance covers a speed range from 50 to 120 percent of design and a pressure-ratio range from 5.0 to 35.0. The turbine was designed for a 50.8 centimeter (20.0 in.) tip diameter turbofan simulator. Computed results are compared with the experimental turbine data obtained from testing three fan configurations with the turbofan simulator in air. The comparison indicates good agreement over the range of speeds and pressure ratios covered by the experimental data.

Wasserbauer, C. A.↗

Performance mapping of a 30 cm engineering model thruster

A 30 cm thruster representative of the engineering model design has been tested over a wide range of operating parameters to document performance characteristics such as electrical and propellant efficiencies, double ion and beam divergence thrust loss, component equilibrium temperatures, operational stability, etc. Data obtained show that optimum power throttling, in terms of maximum thruster efficiency, is not highly sensitive to parameter selection. Consequently, considerations of stability, discharge chamber erosion, thrust losses, etc. can be made the determining factors for parameter selection in power throttling operations. Options in parameter selection based on these considerations are discussed.

Poeschel, R. L.↗

Performance map of a heat pipe charged with ammonia

Test results are presented which describe dryout in type-304 stainless steel heat pipes when ammonia is the working fluid. Graph compares heat transfer capabilities of both ammonia and water. Heat pipe apparatus and performance are described.

Schwartz, J.↗

Performance Mapping Studies in Redox Flow Cells

Pumping power requirements in any flow battery system constitute a direct parasitic energy loss. It is therefore useful to determine the practical lower limit for reactant flow rates. Through the use of a theoretical framework based on electrochemical first principles, two different experimental flow mapping techniques were developed to evaluate and compare electrodes as a function of flow rate. For the carbon felt electrodes presently used in NASA-Lewis Redox cells, a flow rate 1.5 times greater than the stoichiometric rate seems to be the required minimum.

Hoberecht, M. A.↗

LiDAR-Based Map Relative Localization Performance Analysis for Landing on Europa

This paper presents preliminary simulations andanalyses done to assess the feasibility of performing Map RelativeLocalization (MRL) with the Europa Lander LiDAR beingdeveloped for the Europa Lander Pre-Phase A concept. MapRelative Localization is the process of determining the horizontalposition of a lander with respect to an onboard, a-priori map,by comparing the map to sensor observations of the terrain duringdeorbit, descent, and landing (DDL). Although kilometerscaleposition knowledge is commonly available during DDL,landing in hazard-rich environments requires position errors of100 m or less. Prior knowledge in the case of Europa Landerwill be visual and topographic maps collected by the upcomingEuropa Clipper mission. The Mars 2020 Lander Vision System(LVS) uses images from a camera to localize with respect tovisual maps. This technology, as well as a 3D imaging LiDAR indevelopment for hazard detection, is currently baselined for theEuropa Lander Pre-Phase A concept. This paper investigatesthe potential use of the hazard detection LiDAR to performMRL with respect to a 3D digital elevation model (DEM)provided by the Europa Clipper mission, as an alternative orbackup solution to passive optical MRL. Compared to passiveoptical MRL, one advantage of LiDAR-based localization isthat it is insensitive to lighting conditions, potentially relaxingrequirements on synchronizing map acquisition and landingtime of day. To analyze LiDAR based MRL performance,six representative terrains are synthetically up-sampled fromGalileo-derived maps of Europa to a resolution of 0.5 m/pxand covering an area of 4 km by 4 km. These maps are usedas ground-truth to generate simulated noisy a-priori onboardtopographic maps expected from Europa Clipper as well assimulated LiDAR DEMs generated at an altitude of 5 km duringEuropa Lander DDL. The simulated LiDAR DEM is matchedagainst the simulated map via 2D normalized cross-correlation,exploiting the accurately known spacecraft attitude to avoidthe need for more computationally intensive algorithms such asIterative Closest Point (ICP). Two sources of measurement errorare identified for analysis: 1) additive Gaussian noise in therange measurements from the Europa Lander LiDAR and theEuropa Clipper derived maps and 2) errors in the LiDAR DEMinduced by errors in the Europa Lander state estimate which isused to de-warp the LiDAR scan data into a DEM format. Weassess the effect of each of these types of errors independently onmatching performance as well as the overall performance whenall types of error are introduced. Additionally, we present theresult of a sensitivity study to terrain frequency content.

Trawny, Nikolas↗