Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance Assessment of the Overall Building Envelope Thermal Performance—Building Envelope Performance (BEP) Metric

Today, to describe the thermal performance of the building envelope and its components we use a variation of metrics; such as, R-value, ACH (air exchange rate per hour), SHGC (solar heat gain coefficient) of windows, U-factor etc. None of these performance indicators is meant to represent the overall thermal performance. In this paper, such a metric is introduced, the BEP (building envelope performance) value. Unlike the thermal resistance, typically expressed as an R-value, the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior (solar) thermal loads: conductive and radiant heat transfer, and air infiltration. To demonstrate BEP’s utility, validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus. Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics, the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope. The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner.

42 ENGINEERING↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Evaluating the Performance Envelope of Axial Flow HEPA Filter Designs - 17466

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the Department of Energy National Nuclear Security Administration (DOE/NNSA) complex. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels and conditions that fibrous glass HEPA filters can handle. Axial Flow filters can be purchased with physical separators or embossed medium to maintain proper pleat geometry. Separator-less designs use media embossed with a corrugation pattern to retain pleat geometry. At least some versions of the separator-less filter packs have demonstrated unexpected and rapid failure under slightly elevated temperature and humidity conditions. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. Mississippi State University is conducting studies to more clearly identify the operating envelope of separator and separator-less designs of ASME AG-1 Section FC axial flow HEPA filters under a set of generic design basis conditions. A parallel study is also being conducted to evaluate the effects of age on fibrous glass HEPA filters. Activities described in this paper have been conducted under Institute for Clean Energy Technology (ICET's) NQA-1 nuclear quality assurance program approved by DOE-EM. Testing meets the requirements of EM Quality Assurance Program (QAP) EM-QA-001, Rev. 1, June 11, 2012 that includes the applicable requirements of NQA-1-2008/2009a and DOE Order 414.1D. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Technology Assessments of High Performance Envelope with Optimized Lighting, Solar Control, and Daylighting

The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Building Performance: Field Results of Thin-Glass Triple-Pane Window Demonstrations

To meet California and the nation's ambitious energy targets, energy use in the building sector must drop dramatically. Windows continue to be the lowest thermally performing envelope system in the nation's buildings, resulting in poor overall envelope performance and potential impacts to human health and comfort. Current best practice new window performance is typically met by double-pane low-solar-gain glazing. Thin-glass triple-pane windows are a highly promising next step forward in performance and have been deployed in two California multi-family sites to quantify field performance and building energy savings. The technology assessed offers the performance benefits of traditional triple-pane but with little increase in weight or cost, enabling incremental costs competitive with alternative energy reduction solutions for the building envelope. This paper covers a detailed investigation into the demonstration project and measured performance benefits of the windows after a full year of data collection.

Hart, Robert↗

Online Learning for Commercial Buildings

There has been an increased interest in designing optimization based techniques for the control of building heating, ventilation, and air-conditioning (HVAC) systems for either improving the energy efficiency of buildings or providing ancillary services to the electric grid. The performance of such prediction-based control techniques heavily rely on the model of a building’s thermal dynamics. However, the development of high fidelity building thermal dynamic models is challenging given the presence of large uncertainties that affect thermal loads in buildings such as building envelope performance, thermal mass, internal heat gains as well as occupants' behavior. In this paper, we propose a method to identify both a resistive-capacitive parametric model, and non -parametric load uncertainties using measured input-output data. The parametric model is obtained using semi-parametric regression, whereas the non-parametric part is based on Random Forest, where regression trees are used to derive the dependency of non-parametric terms on both building operation parameters and ambient temperature. The effectiveness of the method is evaluated using experimental data collected from an office building at the Pacific Northwest National Laboratory (PNNL) campus. The proposed methodology was observed to provide improved accuracy over appropriate baseline strategies, when predicting indoor air temperatures.

Dong, Jin↗

Energy performance analysis of smart wall system with switchable insulation and thermal storage capacity

The ever-increasing global energy demand and the issues caused by population growth and unsustainable energy resource usages have several environmental and economic impacts. The on-demand capability of dynamic wall systems with switchable insulation systems can contribute toward energy efficiency and reduced electric cost using "building-as-a-battery." In this paper, the performance of an exterior envelope system that employs a switchable insulation system is investigated. A COMSOL simulation was used to study the envelope performance under three switchable insulation locations in the wall system. The on and off switching cycle included insulating or conducting the exterior, interior, or both sides of the mass wall system. To validate the simulation work, an experimental test was conducted in climate chamber on a 4 × 8 in. wall system with identical wall components used in the COMSOL simulation. Results show a good agreement between the experiment and simulation results. The wall system with switchable insulation placed on the exterior side provided the highest interior inward heat flux when compared with the interior or split insulation. Also, an exterior switchable insulation system in addition to a thermal mass maintained a positive heat flow for more hours when the outdoor temperature was lower than the interior temperature.

Iffa, Emishaw↗

A conceptual model for how to design for building envelope characteristics. Impact of thermal comfort intervals and thermal mass on commercial buildings in U.S. climates

The paper presents a simplified conceptual model for energy demand calculations based on building envelope characteristics, thermal mass and local climate. It is based on a network model and lumped analysis of the dynamic process. Characteristic parameters for the buildings are suggested; Driving temperature (DT), Driving temperature difference, (DTD), External Load Temperature (ELT), and Thermal Load Resistance (TLR). The Building Envelope Performance ( BEP 0 ), based on a controlled constant indoor temperature is introduced. Solution techniques using stable explicit forward differences based on analytical solutions are derived. The conceptual model has been used for mapping the Driving temperature difference and introduced two performance factors and . The first factor represents the effect of thermal comfort interval and thermal mass on the energy demand. The latter represents the ratio between cooling and heating energy demand. These three parameters and factors have been visualized on U.S. maps and enable a possibility to communicate the demand of energy, and cooling and the coupling to building characteristics, in a concise way.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of AG-1 FC Filters Under Upset Conditions and the Effects of Aging on Filters - 19501

High efficiency particulate air (HEPA) filters are routinely used in nearly every operating Department of Energy (DOE) and National Nuclear Safety Administration (NNSA) nuclear facility. These nuclear grade HEPA filters installed in DOE and NNSA confinement ventilation systems are credited as the final barrier to protect the environment, the public, and the worker from accidental release of virtually all airborne radioactive materials, and must meet the American Society of Mechanical Engineers' (ASME) Code on Nuclear Air and Gas Treatment (CONAGT) AG-1 standard. This testing activity evaluates ASME AG-1 Section FC axial flow HEPA filters, both separator and separator-less, under upset conditions. Additionally, testing efforts have analyzed the effects of filter degradation due to aging. In 1997, the Defense Nuclear Facilities Safety Board (DNFSB) raised concerns of the potential vulnerability of HEPA filters in vital safety systems, both from a design stand point and the potential for degradation of HEPA filter performance over time. The DOE Office of Environmental Management (DOE-EM) has a Cooperative Agreement with Mississippi State University (MSU) Institute for Clean Energy Technology (ICET) to conduct testing of HEPA filters. DOE-EM has established a Technical Working Group (TWG) of over thirty subject matter experts from the nuclear industry to provide input and oversight of ICET projects and activities. This has included establishment/approval of testing parameters for evaluating these filters under ASME NQA-1 compliant Test Plans. The current scope of work involves evaluation of the performance envelope for new and aged separator and separator-less designs of AG-1 Section FC axial flow HEPA filters. A range of elevated test conditions (T and RH) are used to determine the operating envelope within which DOE nuclear safety experts can credit installed HEPA filter performance, thereby establishing a risk-informed DOE service life. This paper will present preliminary test results of new and aged axial flow filters tested at ICET. Results in this paper include data collected from new separator and separator-less type FC HEPA filters and equivalent test data for a limited group of aged separator and separator-less type FC HEPA filters. Testing for both scopes of work evaluate initial filter performance under ambient conditions of temperature (60 deg. F - 80 deg. F (∼16 - ∼27 deg. C)) and relative humidity (40-60%), loading of each filter with Aluminum Trihydroxide, Al(OH)3, to a specified differential pressure, and then exposing the filter to specified elevated temperature and relative humidity conditions. In addition to the upset conditions of elevated temperature and relative humidity, the performance of HEPA filters under fire scenarios is not well characterized. ICET is currently designing a burn box and testing apparatus to study the effects of fire from burning liquids and a wide range of blends of combustible solids. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Double Wall Framing Technique An Example of High Performance, Sustainable Building Envelope Technology

Double wall technologies utilizing wood framing have been well-known and used in North American buildings for decades. Most of double wall designs use only natural materials such as wood products, gypsum, and cellulose fiber insulation, being one of few building envelope technologies achieving high thermal performance without use of plastic foams or fiberglass. Today, after several material and structural design modifications, these technologies are considered as highly thermally efficient, sustainable option for new constructions and sometimes, for retrofit projects. Following earlier analysis performed for U.S. Department of Energy by Fraunhofer CSE, this paper discusses different ways to build double walls and to optimize their thermal performance to minimize the space conditioning energy consumption. Description of structural configuration alternatives and thermal performance analysis are presented as well. Laboratory tests to evaluate thermal properties of used insulation and whole wall system thermal performance are also discussed in this paper. Finally, the thermal loads generated in field conditions by double walls are discussed utilizing results from a joined project performed by Zero Energy Building Research Alliance and Oak Ridge National Laboratory (ORNL), which made possible evaluation of the market viability of low-energy homes built in the Tennessee Valley. Experimental data recorded in two of the test houses built during this field study is presented in this work.

Building Envelope↗

Assessment of failure modes of monolithic fuel plates

Monolithic fuel is a fuel form that is considered for the conversion of high performance research reactors. In order to qualify this new fuel system, the fuel plates should meet the safety standards and perform well in reactor. The fuel system must maintain its mechanical integrity, sustain a geometric stability and should have stable and predictable irradiation behavior. The requirement to maintain mechanical integrity under normal operating conditions is primarily demonstrated by a successful testing of fuel plates up to the limiting conditions defined by the fuel performance envelope, including an adequate margin. Although large number of plates have been tested with satisfactory thermo-mechanical performance, post-irradiation examination of plates from previous RERTR-12 experiments have revealed that pillowing occurred in several plates, rendering performance of these plates unacceptable. To address such failures, efforts are underway to define the mechanisms responsible for the in-reactor pillowing, and suggest improvements to the fuel plate design and operational envelope. For this purpose, selected plates from previous experiments were simulated to understand the thermo-mechanical response of the plates to the fission density and thermally induced stresses. Simulation results were then comparatively evaluated with post-irradiation examinations of selected plates. The simulation results and experimental observations established a possible correlation between failure by plate pillowing, high porosity and a presence of tensile stress state. The study has implied that porosity leading to degradation of material properties, accompanied by a sufficiently large tensile stress state can lead to a pillowing-type failure at reactor shutdown. This paper presents these findings, discusses such failure modes, and the influence of fuel burn-up and power on the magnitude of the shutdown-induced tensile stresses.

42 ENGINEERING↗

Versatile Test Reactor Conceptual Core Design

The VTR is a 300-MW(thermal) sodium-cooled fast reactor (SFR) designed for the specific purpose of delivering unique testing capabilities to enable the advancement of all reactor technologies. With its flux level, irradiation volume, and operational flexibility, the VTR will enable accelerated testing of materials, fuels, and various components needing irradiation testing. Proven SFR technologies and design approaches have been leveraged in designing the VTR core, ensuring the highest possible readiness level. This resulted in the VTR using ternary metallic fuel and delivering fast flux levels in excess of 4 x 10 15 n/cm 2 ∙ s over large useful volumes, corresponding to about 60 dpa/year in steel. As part of the design efforts, the VTR core performance has been determined for a representative configuration, ensuring that the reactivity control systems offer sufficient shutdown margins, that the core can be safely cooled in all situations, and that reactivity feedback coefficients are conducive to a favorable safety behavior. Furthermore, the incorporation of features such as fuel assembly storage in the shield region supports the flexible and reliable operation of the VTR. Additional design work has been ongoing as well. This includes thorough shielding performance evaluations to ensure safe operation of the VTR, verification and validation of the design tools used to achieve compliance with Nuclear Quality Assurance (NQA-1) requirements, early assessment of the impact of irradiation experiments on the core performance envelope and associated margins, and in-depth uncertainty quantification efforts to quantify the anticipated range of performance characteristics. An experimental program supporting the VTR core design has been set up, with the current focus being on thermal-hydraulic experiments. The purpose of this experimental program is to obtain confirmatory measurements to serve directly as part of the core design basis or as part of the validation cases supporting the simulation tools used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advancing Replicable Solutions for High-Performance Homes in the Southeast

Southface Energy Institute (Southface) partnered with owners and/or builders with various market constraints and ultimate goals for three projects in different climate zones: Savannah, GA (CZ 2), Clemson, SC (CZ 3), and LaFayette, GA (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these high performance homes. The three bedroom/two bathroom test home in Savannah Gardens on an elevated slab foundation has a semi-conditioned, encapsulated attic. A neighboring home built to EarthCraft specifications was also monitored as a control for exterior foam insulation and a heat pump water heater (HPWH). For the JMC Patrick Square, a single-story project in Clemson, the small-scale production builder wanted to increase their level of energy efficiency beyond their current green building practices, including bringing ducts into conditioned space. Through a combination of upgrade measures the team met this goal and achieved many Zero Energy Ready Home requirements. LaFayette Housing Authority undertook a development of 30 affordable rental housing units in 15 duplexes in LaFayette, GA. Because they would be long-term owners, their priorities were low utility bills for the residents and durable, maintainable buildings. The team employed BEopt to optimize buildling envelope and systems choices, including 2x6 advanced framed walls, insulated slab, and heat pump water heater in a utility closet which was ducted to/from an encapsulated attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

It's All About the Envelope: Prioritizing Envelope Upgrades for Electrification of Cold Climate Homes

Building decarbonization via electrification on a clean grid is the most promising climate solution proposed to date for the building sector. In cold climate zones, building electrification will be driven in large part by moving from natural gas space heating to cold climate heat pumps (CCHPs). CCHPs are commercially available today, including economical cold climate air source heat pumps (ccASHPs). But there's one big problem - wide-scale adoption of ccASHPs will dramatically increase winter peak electricity demand, even with the highest efficiency ccASHP products. Furthermore, cold climate space heating loads will drive unprecedented electric system peaks during the lowest periods of renewable generation and are likely to overwhelm existing distribution systems. This scenario is avoidable by coupling electrification with building envelope upgrades to reduce peak heating loads. This paper presents a model, built from home energy audit and research data sets, that quantifies the above challenges. Results demonstrate how weatherization efforts coupled with additional high-performance envelope upgrade measures can prepare the building stock for electrification and show the benefit these measures can bring to future utility operations. Much of this envelope upgrade work is cost-effective, according to conservative cost-benefit testing and program successes to date, and is coupled with substantial non-energy benefits. However, persistent market barriers have made scaling of envelope retrofit work challenging for decades, suggesting additional policy support is required. Lessons learned from previous policy experience, combined with new technology and administrative support, create exciting potential for this decarbonization climate solution.

air sealing↗

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗