Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle beam irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nanostructure Patterning Under Energetic Particle Beam Irradiation

Energetic ion bombardment can lead to the development of complex and diverse nanostructures on or beneath the material surface through induced self-organization processes. These self-organized structures have received particular interest recently as promising candidates as simple, inexpensive, and large area patterns, whose optical, electronic and magnetic properties are different from those in the bulk materials. Compared to the low mass efficiency production rate of lithographic methods, these self-organized approaches display new routes for the fabrication of nanostructures over large areas in a short processing time at the nanoscale, beyond the limits of lithography. Although it is believed that surface nanostructure formation is based on the morphological instability of the sputtered surface, driven by a kinetic balance between roughening and smoothing actions, the fundamental mechanisms and experimental conditions for the formation of these nanostructures has still not been well established, the formation of the 3-D naopatterns beneath the irradiated surface especially needs more exploration.

42 ENGINEERING↗

Gated Irradiation With Scanned Particle Beams

Purpose: To demonstrate mitigation of the interplay effects of scanned particle beams and residual target motion within a gating window by increased overlap of pencil beams. Methods and Materials: Lateral overlap was increased by increasing the pencil beam widths or by decreasing the distance between the pencil beams (scan grid). Longitudinal overlap was increased by reducing the distance between iso-range slices. For scanned carbon ion beams, simulation studies were performed and validated experimentally to determine the required parameters for different residual motion characteristics. The dose distributions were characterized by the maximal local deviations representing local over- and underdosage. Results: For residual lateral motion, the local deviations were <5% for 2, 4, and 7 mm residual motion within the gating window for a 2-mm scan grid and pencil beams of 10, 14, and 18 mm full width at half maximum, respectively. Decreasing the iso-range slice distance from 3 mm to 1 mm effectively mitigated {<=}10 mm water-equivalent range changes. Experimental data reproduced the simulation results. Conclusion: In charged particle therapy with a scanned beam, interplay effects between gated beam delivery and residual target motion can be decreased effectively by increasing the overlap between pencil beams laterally, as well as longitudinally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

B.Gregory Lecture

Third series of "Gregory lectures" on the memory of B. Gregory (1919-1977), DG from 1965 to 1970. The first conference B. Gregory is presented by Professor V. Weisskopf, his predecessor. Chriss Greeg from Berkeley also speaks.

beam↗

Experimental characterisation of charged particle beams accelerated by irradiating thin targets of different materials with ultrashort laser pulses

We present the results of experimental investigation of ion and electron fluxes produced by irradiating thin foils with laser USPs. These experiments were carried out on the Sokol-P laser facility (pulse duration {approx}1 ps, power {approx}20 TW) using lavsan, aluminium, and copper targets of equal thickness ({approx}5 {mu}m). Ions were recorded employing Thomson spectrometers and a time-of-flight spectrometer with a silicon semiconductor detector. To record electrons, use was made of electron spectrometers involving the rotation of particle trajectories by 180{sup 0} in magnetic field. The ionic composition of the charged particle beam was determined and the beam shape was investigated in relation to the target material. (effects of laser radiation on matter)

36 MATERIALS SCIENCE↗

Delivery verification using 3D dose reconstruction based on fluorescence measurement in a carbon beam scanning irradiation system

The authors have developed a method to reconstruct the 3D dose distribution in a particle beam scanning irradiation system. In this scheme, 3D dose distribution is reconstructed by using the measured images of fluence distribution, which are taken for each iso-energy slice (i.e., the unit of the depth scanning). A fluorescent screen with a CCD camera is used to measure the fluence distribution. This system was installed at the HIMAC experimental port and tested by using carbon ion beams. Since a maximum difference between the reconstructed dose and the ionization chamber measurement was around 5% in the target volume, this system can be useful for quick verification of 3D dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defect production in strained p-type Si{sub 1-x}Ge{sub x} by Er implantation

Strained p-Si{sub 1-x}Ge{sub x} (x=5.3%, 10.2%, and 15.4%) was irradiated at room temperature with 160 keV {sup 166}Er{sup 2+} ions to a fluence of 1x10{sup 10} or 3x10{sup 13} Er/cm{sup 2}. The defects induced by ion implantation were investigated experimentally using high-resolution x-ray diffraction, Rutherford backscattering and channeling spectroscopy, and deep level transient spectroscopy. X-ray diffraction indicates that the damage induced by Er implantation produces a slight perpendicular expansion of the SiGe lattice. For all compositions, channeling measurements reveal that Er implantation in p-Si{sub 1-x}Ge{sub x} to a fluence of 3x10{sup 13} Er/cm{sup 2} induces an amorphous region below the Si{sub 1-x}Ge{sub x} surface. Annealing at 850 deg. C for 30 s, results in a reduction in damage density, a relaxation of the implantation-induced perpendicular expansion of the SiGe lattice in the implanted region, while a more pronounced relaxation of the compressive strain SiGe is observed for higher Ge content (x=0.10 and 0.15). On the other hand, for the annealed SiGe samples that were implanted with Er at the fluence of 10{sup 10} Er/cm{sup 2}, the compressive strain in the SiGe layer is nearly completely retained. Deep level transient spectroscopy studies indicate that two prominent defects with discrete energy levels above the valence band are introduced during Er implantation. Their activation energy was found to decrease with increasing Ge content. However, the relatively large local strain induced by high fluence Er implantation reduces the activation energy by 40 meV with respect to the low fluence Er implanted p-Si{sub 1-x}Ge{sub x}. This shift (40 meV) in the activation energy remains constant regardless of the Ge content, suggesting that the Si{sub 1-x}Ge{sub x} layers remained fully strained after Er implantation. The observed defects are further compared to those introduced by alpha particle irradiation and electron beam metal deposition. The results indicate that defects introduced by Er implantation have similar electronic properties as those of defects detected after electron beam deposition and alpha particle irradiation. Therefore, it is concluded that these defects are due to the Er implantation-induced damage and not to the Er species specifically.

36 MATERIALS SCIENCE↗

Structural Modification of Graphene on Copper Substrates Irradiated by Nanosecond High-Intensity Ion Beams

Interaction of a nanosecond high-intensity pulsed ion beam with thin graphene films on copper substrates is analyzed. Methods of Raman spectroscopy are used to investigate the degree of graphene degradation depending on the integral implanted dose. The role of the substrate in the structural degradation of graphene irradiated by charged particle beams is demonstrated using the software package SRIM, intended for modeling radiative defect cascades under irradiation by charged particle beams, and the data on radiation resistance of graphene available in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-EF-303-11: Activity Distributions of Positron-Emitting-Isotopes Activated by Modulated Spot-Scanning Particle Beams

Purpose: To present the characteristics of positron-emitting-isotope (PEI) activity distributions on homogeneous and CIRS thorax phantoms irradiated by modulated spot-scanning carbon-ions and protons in Siemens IONTRIS system. Methods and Materials: Cylindrical homogeneous wax was irradiated by carbon-ions and protons of 10cm uniform square field with single-energy-layer ranges of 7cm, 16cm and 29cm. Images of PEI distributions were acquired over a period of 30 minutes at 10 minutes after each irradiation. Optimized uniform biological-equivalent doses of carbon-ions over a 5.0cm spherical target was delivered to CIRS phantom. Doses with range shifts in depths from 1mm to 6mm were also calculated and delivered to evaluate the accuracy of measuring activated PEI distributions. Results: Activated PEI distribution on homogeneous phantoms showed sharper peak near distal edge with flatter distribution toward proximal depth by carbon-ions than by protons. For depths near at Bragg-peak, penetration-depth spreading for energies from 10MeV/u to 60 MeV/u are from 0.4mm to 10.3mm, and 1.2mm to 30.4mm for projectile-fragments by carbon-ions and target-fragments by protons, respectively. For depths proximal to Bragg-peak, target-fragments for both carbon-ions and protons had minimal energy dependence in depth. For complex dose distributions delivered to CIRS thorax phantom, similar PEI peak-like distributions were still observed for carbon-ions. And, the changes at locations and edges of measured PEI peak were correlated within 0.5mm of shifted ranges. Mean activities over 5.0cm spherical target were similar for CISR phantom irradiated by doses with various range shifts. Conclusions: Peak-like PEI distributions by carbon-ions with good correlation to distal edges in both homogeneous and CIRS thorax phantoms present the potential for the in-vivo range verification while additional efforts is needed for protons. Due to flat distributions for depths at 6mm proximal to distal edges, mean activity at target might be used for in-vivo dose verification of target.

60 APPLIED LIFE SCIENCES↗

Phase Transformations among TiO2 Polymorphs

Polymorphs widely exist in nature and synthetic systems and are well known to determine material properties. Understanding phase transformation mechanisms among polymorphs enables the design of structures and tuning of phases to tailor material properties. However, current understanding is limited due to the lack of direct observations that track the processes and the structural evolution is not known at atomic scale. Here, integrating (semi) in situ transmission electron microscopy and density functional theory, we report atomic structural evolutions of phase transformation from anatase (A) to rutile (R), brookite (B), R-phase, and TiO. Besides the consistent paths with previous reports, we discover several unreported paths, including a [001] direction and (020) plane of anatase to [100]A and (011)R of rutile, respectively, ( , ) and , . Density functional theory analysis elucidates atomic structural evolution during the processes and over 16% of Ti-O bonds break and reform during the processes with energy barriers of ~0.7-1.0 eV per TiO2 formula unit. Under electron-beam irradiation, anatase particles transform into TiO2-R phase or TiO at high or room temperature, respectively. We also reveal the anisotropic nature of electron-beam effect, which is seldom discussed: dependence of crystallographic orientation with respect to electron-beam irradiation direction. Understanding the atomic structural evolution sheds light on interpreting and controlling TiO2 polymorphs and interface structures for various applications. The revealed electron-beam effects in our work provide guidance for in situ transmission electron microscopy studies.

Song, Miao↗

Dose Modeling of Noninvasive Image-Guided Breast Brachytherapy in Comparison to Electron Beam Boost and Three-Dimensional Conformal Accelerated Partial Breast Irradiation

Purpose: To perform dose modeling of a noninvasive image-guided breast brachytherapy (NIIGBB) for comparison to electrons and 3DCRT. Methods and Materials: The novel technology used in this study is a mammography-based, noninvasive breast brachytherapy system whereby the treatment applicators are centered on the planning target volume (PTV) to direct {sup 192}Ir emissions along orthogonal axes. To date, three-dimensional dose modeling of NIIGBB has not been possible because of the limitations of conventional treatment planning systems (TPS) to model variable tissue deformation associated with breast compression. In this study, the TPS was adapted such that the NIIGBB dose distributions were modeled as a virtual point source. This dose calculation technique was applied to CT data from 8 patients imaged with the breast compressed between parallel plates in the cranial-caudal and medial-lateral axes. A dose-volume comparison was performed to simulated electron boost and 3DCRT APBI. Results: The NIIGBB PTV was significantly reduced as compared with both electrons and 3DCRT. Electron boost plans had a lower D{sub min} than the NIIGBB technique but higher V{sub 100}, D{sub 90}, and D{sub 50}. With regard to PTV coverage for APBI, the only significant differences were minimally higher D{sub 90}, D{sub 100}, V{sub 80}, and V{sub 90}, with 3DCRT and D{sub max} with NIIGBB. The NIIGBB technique, as compared with electrons and 3D-CRT, achieved a lower maximum dose to skin (60% and 10%, respectively) and chest wall/lung (70-90%). Conclusions: NIIGBB achieves a PTV that is smaller than electron beam and 3DCRT techniques. This results in significant normal tissue sparing while maintaining dosimetric benchmarks to the target tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Studying of Dust Particles Charging by Electron Beam

The studying of the dusty plasma properties under electron beam action are of great interest because it gives the unique opportunities for experimental investigation of strongly coupled systems as well as for developing the new dusty plasma technologies of creating the new composite materials. Highly charged dust particle generates electrostatic field that can accelerate positive ions to high power. It gives the unique possibilities of using these macroparticles (for deeply ions implantation, as catalysts for increasing rate of reactions with the high energy barrier, in the new ionic engines etc.). Presented work deals with the experimental investigation of dust particles charging under direct influence of electron beam. On the basis of experimental data the average velocities of dust particles were obtained and the charge of macroparticle was estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Test Beam and Irradiation Facilities

Progress in particle physics depends on a multitude of unique facilities and capabilities that enable to advance detector technologies. Among others, key facilities involve test beams and irradiation facilities, which allow users to test the performance and lifetime of their detectors under realistic conditions. Test beam facilities are particularly important for collider and neutrino detector applications, while irradiation facilities are crucial for collider as well as some space-based astro particle detectors. This contributed Snowmass paper aims to summarize existing test beam and irradiation facilities as well as develop the need and proposals for future facilities.

43 PARTICLE ACCELERATORS↗

Chromosome aberrations and cellular premature senescence as radiation-induced sub-lethal effects: Implications for laser-driven charged-particle radiotherapy

The use of charged particles significantly reduces the dose absorbed by normal cells due to the inverse dose-depth deposition profile. This is the physical pillar justifying hadrontherapy as the eligible treatment for deepseated tumours. However, a non-negligible amount of radiation is nevertheless absorbed in correspondence with the plateau region of the Bragg curve, which may result in the induction of sub-lethal effects. Very little experimental data exist on the induction of such effects. Moreover, reliable follow-up data on such adverse effects in hadrontherapy patients are limited since this type of treatment has been adopted relatively recently. A fortiori, the dependence of sub-lethal effects on unprecedented factors, such as the exceedingly high dose rates and/or the pulsed nature of beams originated by laser interaction with target materials, is unknown. This warrants investigation prior to a therapeutic use of such beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron Bunch Timing with Femtosecond Precision in a Superconducting Free-Electron Laser

High-gain free-electron lasers (FELs) are capable of generating femtosecond x-ray pulses with peak brilliances many orders of magnitude higher than at other existing x-ray sources. In order to fully exploit the opportunities offered by these femtosecond light pulses in time-resolved experiments, an unprecedented synchronization accuracy is required. In this Letter, we distributed the pulse train of a mode-locked fiber laser with femtosecond stability to different locations in the linear accelerator of the soft x-ray FEL FLASH. A novel electro-optic detection scheme was applied to measure the electron bunch arrival time with an as yet unrivaled precision of 6 fs (rms). With two beam-based feedback systems we succeeded in stabilizing both the arrival time and the electron bunch compression process within two magnetic chicanes, yielding a significant reduction of the FEL pulse energy jitter.

43 PARTICLE ACCELERATORS↗

Laser pulse shaping for additive manufacturing

The present disclosure relates to an apparatus for additively manufacturing a product in a layer-by-layer sequence, wherein the product is formed using powder particles deposited on an interface layer of a substrate. A laser generates first and second beam components. The second beam component has a higher power level and a shorter duration than the first beam component. A mask creates a 2D optical pattern in which only select portions of the second beam components can irradiate the powder particles. The first beam component heats the powder particles close to a melting point, where the particles experience surface tension forces relative to the interface layer. While the particles are heated, the second beam component further heats the particles and also melts the interface layer before the surface tension forces can act on and distort the particles, enabling the particles and the interface layer are able to bond together.

DeMuth, James A.↗

Laser pulse shaping for additive manufacturing

The present disclosure relates to an apparatus for additively manufacturing a product in a layer-by-layer sequence, wherein the product is formed using powder particles deposited on an interface layer of a substrate. A laser generates first and second beam components. The second beam component has a higher power level and a shorter duration than the first beam component. A mask creates a 2D optical pattern in which only select portions of the second beam components can irradiate the powder particles. The first beam component heats the powder particles close to a melting point, where the particles experience surface tension forces relative to the interface layer. While the particles are heated, the second beam component further heats the particles and also melts the interface layer before the surface tension forces can act on and distort the particles, enabling the particles and the interface layer are able to bond together.

DeMuth, James A.↗

Studying the characteristics of scintillation counters in a beam of relativistic particles

In this work, the results of the measurements of characteristics of 40-cm and 2-m scintillation counters irradiated by a particle beam with a momentum of 7 GeV/c from the accelerator of the Institute for High Energy Physics are presented. The scintillators used in counters are BC-404 and BC-408 scintillators. The counters are viewed from both ends by R1828-01 photomultiplier tubes. The PMT signal spectra are well described by a convolution of the Landau and Gaussian distributions. Their width is determined mainly by fluctuations of ionization energy losses. The time distributions of the signals obey the Gaussian law. For the 40-cm counter, the time resolution is σ(T) = 88 ps; for the 2-m counter, it varies from 120–160 ps in its center to ~100 ps near the end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗