Engineering PapersSearch

SEARCH · Engineering Papers

Results for “parametric amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fundamental limits to the generation of highly displaced bright squeezed light using linear optics and parametric amplifiers

High-quality squeezed light is an important resource for a variety of applications. Multiple methods for generating squeezed light are known, having been demonstrated theoretically and experimentally. However, the effectiveness of these methods—in particular, the inherent limitations to the signals that can be produced—has received little consideration. Here we present a comparative theoretical analysis for generating a highly displaced squeezed light from a linear optical method—a beamsplitter mixing a squeezed vacuum and a strong coherent state—and well-studied parametric amplification methods including an optical parametric oscillator, an optical parametric amplifier, and a dissipative optomechanical squeezer seeded with coherent states. We show that the quality of highly displaced squeezed states that can be generated using these methods is limited on a fundamental level by the physical mechanism utilized; across all methods there are significant trade-offs between displacement, squeezing, and overall uncertainty. We explore the nature and extent of these trade-offs specific to each mechanism and identify the optimal operation modes for each. Finally, we identify the conditions for minimum-uncertainty squeezing in arbitrary parametric amplifying systems and show that displacing the output signal will in general violate these conditions, adding noise and degrading squeezing. Published by the American Physical Society 2025

Young, Steve M. (ORCID:0000000173839366)

Generation of scalable genuine multipartite Gaussian entanglement with a parametric amplifier network

Genuine multipartite entanglement is a valuable resource in quantum information science, as it exhibits inseparability across all possible bipartitions of a multimode quantum state. The large degree of quantum correlations can be exploited in various quantum information protocols, such as teleportation, dense coding, and quantum interferometry. Here, in this study, we propose a scheme to generate scalable genuine multipartite continuous-variable entangled states of light using a parametric amplifier network. We verify the presence of genuine quadripartite, hexapartite, and octapartite entanglement through a violation of the positive partial transpose criteria. Additionally, we use 𝛼-entanglement of formation to demonstrate the scalability of our approach to an arbitrary number of 2⁢𝑁 genuinely entangled parties by taking advantage of the symmetries present in our scheme.

Kim, Saesun [Univ. of Oklahoma, Norman, OK (United

Parametrically amplified Josephson plasma waves in YBa 2 Cu 3 O 6+ x : Evidence for local superconducting fluctuations up to the pseudogap temperature T ∗

Experiments that subject underdoped YBa 2 Cu 3 O 6+x (YBCO) to intense terahertz pulses at temperatures between the transition temperature T c and the pseudogap scale T ∗ have revealed a reflectivity edge that resembles that of the superconducting state, together with second harmonic generation of a probe pulse modulated at a similar frequency. These have been interpreted in terms of parametric amplification of the lower Josephson plasmon mode. Since this mode is often associated with coherent oscillations between bilayers in the YBCO structure, these experiments have led to the suggestion that the intense pump has created (or revealed) in-plane pair coherence up to T ∗ ≈ 400 K. In this paper we propose an alternative explanation by assuming the existence of local pair amplitude and phase at equilibrium for T c < T < T ∗ . The phase correlation spans only a few lattice constants and we do not assume any pump-induced enhancement of this correlation, either in-plane or between bilayers. Instead, the coherent drive, via a parametric amplification process, induces coherence in the Josephson currents between members of bilayers. When combined with a Floquet framework, the reflectivity data can be explained. The key point is that in the lower Josephson plasmon, the coupling between bilayers is mainly capacitive; the Josephson current between bilayers can be set to zero without strongly affecting the parametric amplification process. Importantly, while superconducting coherence may not be created by the pump, the pseudogap phase must possess a local pairing amplitude at equilibrium. Consequently, these experiments have strong implications for the understanding of the pseudogap phase.

parametric amplification

Predicted third-order sweet spots for phi-junction Josephson parametric amplifiers

Hybrid superconductor-semiconductor nanowire Josephson junctions exhibit skewed and phi-shifted current phase relations when an in-plane magnetic field is applied along the weak link's spin-orbit effective field direction. These junctions can have an asymmetric Josephson potential with odd-order nonlinearities. A dominant third-order nonlinearity can be achieved by tuning the magnetic field to a sweet spot. Sweet spots persist when higher order Josephson harmonics are included. This makes it possible to have a single Josephson junction dipole element with three-wave mixing capability, which is favorable for pump-efficient amplification. Electrostatic gate tunability of the semiconductor weak link can make it operable within an extended range of working frequencies, and the inclusion of micromagnets can facilitate near-zero magnetic field operation.

Reza, Tasnum [Univ. of Pittsburgh, PA (United Stat

Femtosecond wavelength-tunable laser system using gain managed nonlinear amplifier

Optical parametric amplifiers require a seed energy at the spectral range of interest for amplification. In the case of pulsed laser systems, seed pulse characteristics such as spectral energy density and spectral uniformity influence laser system design and performance. In this letter, we present the design and modeling of a few micro-joules, wavelength-tunable, femtosecond parametric amplifier system. We employ a gain-managed nonlinear fiber amplifier output as the seed pulse. This seed pulse is relatively uniform across its bandwidth from 1010 to 1180 nm. Its spectral energy density averages 600 pJ/nm, 30 times higher than conventional counterparts. The overall amplification gain is 175, and the conversion efficiency is 17.5%. The inherent quasi-linear chirp of the seed pulse is utilized to alter the output wavelength. Our tunable femtosecond laser is an enabling technology for high-demand applications such as time-resolved spectroscopy, nonlinear and advanced material research, and biomedical imaging and microscopy modalities.

47 OTHER INSTRUMENTATION

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Axion detection via superfluid 3 He ferromagnetic phase and quantum measurement techniques

We propose to use the nuclear spin excitation in the ferromagnetic A 1 phase of the superfluid 3 He for the axion dark matter detection. This approach is striking in that it is sensitive to the axion-nucleon coupling, one of the most important features of the QCD axion introduced to solve the strong CP problem. We review a quantum mechanical description of the nuclear spin excitation and apply it to the estimation of the axion-induced spin excitation rate. We also describe a possible detection method of the spin excitation in detail and show that the combination of the squeezing of the final state with the Josephson parametric amplifier and the homodyne measurement can enhance the sensitivity. It turns out that this approach gives good sensitivity to the axion dark matter with the mass of $\mathcal{O}$(1) μeV depending on the size of the external magnetic field. We estimate the parameters of experimental setups, e.g., the detector volume and the amplitude of squeezing, required to reach the QCD axion parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Joint Experimental and Computational Characterization of Sum-Frequency Generation between a Continuous Wave Laser and an Ultrafast Frequency Comb Laser for Tunable Laser Development

Ultrafast optical frequency combs allow for both high spectral and temporal resolution in molecular spectroscopy and have become a powerful tool in many areas of chemistry and physics. Ultrafast lasers and frequency combs generated from ultrafast mode-locked lasers often need to be converted to other wavelengths. Commonly used wavelength conversions are optical parametric oscillators, which require an external optical cavity, and supercontinuum generation combined with optical parametric amplifiers. Whether commercial or home-built, these systems are complex and costly. Here, we investigate an alternative, simple, and easy-to-implement approach to tunable frequency comb ultrafast lasers enabled by new continuous-wave laser technology. Sum-frequency generation between an Nd:YAG continuous-wave laser and a Yb:fiber femtosecond frequency comb in a beta-barium borate (BBO) crystal is explored. The resulting sum-frequency beam is a pulsed frequency comb with the same repetition rate as the Yb:fiber source. SNLO simulation software is used to simulate the results and provide benchmarks for designing future systems to achieve wavelength conversion and tunability in otherwise difficult-to-reach spectral regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

ADMX Axion Dark Matter Bounds around 3.3 μ eV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine-Fischler-Srednicki-Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultralow noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 μ eV , assuming a standard halo model with a local energy density of 0.45 G e V / cm 3 made up 100% of axions. Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS

High-repetition rate, CEP-stable shortwave infrared source with two-cycle pulses for field-resolved spectroscopy

We report on a passively carrier-envelope phase (CEP)-stable optical parametric amplifier generating two-cycle pulses at 2060 nm with energies of up to 2.25 µJ operating at a repetition rate of 400 kHz, specifically designed for applications in field-resolved spectroscopy. The measured pulse duration is 13.6 fs, resulting in two cycles of the carrier wave. Due to the robust CEP-stable front-end design, we achieve an open-loop CEP stability of 250 mrad (rms) and the capability for fast CEP modulation.

47 OTHER INSTRUMENTATION

Quantum sensing for fundamental physics efforts at SQMS

One of the areas of research of the Superconducting Quantum Systems and Materials (SQMS) center is the application of quantum sensing to fundamental physics searches, demonstrating that quantum sensors can greatly improve the sensitivity of experiments searching for Beyond the Standard Model (BSM) physics, or performing high-precision measurements. Theorists have developed many ideas for BSM physics that would result in interactions that can in principle be detected, but with signals small enough that they haven t been observed yet. In this field, the capability to lower the detector s thermal noise to few or dozens of mK, and to use QIS technologies such as Josephson Parametric Amplifiers and photon counters (in-situ or itinerant) enable us to reach unprecedented sensitivities and faster scan rates. Here is presented an overview of the quantum sensing efforts at SQMS [1], focusing on theoretical advancements and experimental searches for Dark Sector particles (as dark matter candidates and not), gravitational waves, and precision measurements. The experiments conducted, or under preparation, include axion dark matter (DM) [2, 3], dark photon DM searches [4,5], light-shining-through-wall experiments [6], cavity-based searches for high frequency gravitational waves [7], and measurements of the electron magnetic moment [8]. [1] Berlin, A., et al. "Searches for new particles, dark matter, and gravitational waves with SRF cavities." arXiv preprint arXiv:2203.12714 (2022). [2] Giaccone, B., et al. "Design of axion and axion dark matter searches based on ultra high Q SRF cavities." arXiv preprint arXiv:2207.11346 (2022). [3] Braggio, C., et al. "Quantum-enhanced sensing of axion dark matter with a transmon-based single microwave photon counter." arXiv preprint arXiv:2403.02321 (2024). [4] Fan, X., et al. "One-electron quantum cyclotron as a milli-eV dark-photon detector." Physical review letters 129.26 (2022): 261801. [5] Cervantes, R., et al. "Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities." Physical Review D 110.4 (2024): 043022. [6] Romanenko, A., et al. "Search for dark photons with superconducting radio frequency cavities." Physical review letters 130.26 (2023): 261801. [7] Berlin, A., et al. "Electromagnetic cavities as mechanical bars for gravitational waves." Physical Review D 108.8 (2023): 084058. [8] Fan, X., et al. "Measurement of the electron magnetic moment." Physical review letters 130.7 (2023): 071801.

Giaccone, Bianca

Magnonic spontaneous oscillation induced by parametric pumping

Spontaneous dynamic systems have attracted significant attention for their rich underlying physics such as phase-locking and synchronization. In this work, we report a new mechanism of generating magnetic spontaneous oscillation via parametric pumping. By applying a pump tone to excite propagating spin waves in a yttrium iron garnet delay line, four-wave mixing converts the pump mode into two phase-autonomous propagating magnon modes, i.e. a spontaneous mode with nearly twice the wavenumber of the pump mode and an idler mode with nearly zero wavenumber. This allows us to reliably generate ultrasharp spin wave dynamics with broad frequency tunability from the pump and magnetic field. We show that the spontaneous mode can be phase-locked to a probe tone, similar to an auto-oscillator. Furthermore, the spontaneous dynamics can be used to implement a high-gain magnonic parametric amplifier with a gain up to 40 dB. Our results open a new avenue for studying nonlinear magnonics and synchronization physics in propagating magnon geometry and for developing new magnonic devices.

Li, Yi

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers

Atomistically resolved hot exciton relaxation dynamics in CdSe quantum dots: Experiment and theory

Semiconductor quantum dots (QDs) are well known to give rise to a quantum confined structure of excitons. Because of this quantum confinement, new physics of hot exciton relaxation dynamics arises. Decades of work using transient absorption (TA) spectroscopy have yielded initial simple observations, such as estimates of the cooling rate from single pump photon energy experiments. More detailed TA experiments employed variable pump photon energies to measure excitonic state-resolved transition rates. These TA measurements, usually the simplest form, have been employed to characterize QDs and their relaxation dynamics to this day. Yet, these TA measurements are fundamentally lacking in their ability to measure energy-resolved hot exciton cooling, which requires observation of the full cooling history through the real excitonic manifold. Here, we employ coherent multi-dimensional spectroscopy (CMDS) to perform an atomistically directed study of hot exciton cooling in CdSe QDs, revealing energy resolved relaxation dynamics. CMDS experiments are compared with simulations and prior TA measurements and simpler theories. Our findings reveal a hot exciton relaxation dynamics landscape. This relaxation dynamics landscape is a linear or sub-linear function of excess energy for different structures of QDs, with a strong size dependence. Our model simulations parameterized by the empirical pseudopotential model reproduces the experimental functional form and the dependence upon QD diameter and shell.

Atomistic simulations

Parametric amplification of spin-motion coupling in three-dimensional trapped-ion crystals

Three-dimensional (3D) crystals offer a route to scaling up trapped-ion systems for quantum sensing and quantum simulation applications; however, engineering coherent spin-motion couplings and effective spin-spin interactions in large crystals poses technical challenges associated with decoherence and prolonged timescales to generate appreciable entanglement. Here, we explore the possibility of speeding up these interactions in 3D crystals via parametric amplification. For this purpose, we derive a general Hamiltonian for the parametric amplification of spin-motion coupling that is broadly applicable to normal modes with motion transverse to or along the spatial extent of the crystal. Unlike in lower-dimensional crystals, we find that the ability to faithfully (uniformly) amplify the spin-spin interactions in 3D crystals depends on the physical implementation of the spin-motion coupling. We consider the light-shift gate, and the so-called phase-insensitive and phase-sensitive Mølmer-Sørensen (MS) gates, and we find that only the phase-sensitive MS gate can be faithfully amplified in general 3D crystals. We discuss a situation where nonuniform amplification can be advantageous. We also reconsider the effect of counter-rotating terms on parametric amplification and find that they are not as detrimental as previous studies suggest.

Optical parametric oscillators & amplifiers

Amplification of 10 μm picosecond pulses in a compact optically pumped multiatmosphere CO 2 laser

Picosecond pulses, generated by a commercial mid-IR optical parametric source (∼0.5 ps, 1-5 μJ), have been regeneratively amplified to an energy of ≤2 mJ in a palm-size high-pressure CO 2 amplifier optically pumped by a Q-switched 2.8 μm Cr:Er:YSGG laser. The characteristics of the amplified pulses have been studied as a function of seed wavelength centered around 10.3 or 10.6 μm, and the pressure in the gain medium. The measured amplified pulse length is ∼5 ps. Numerical modeling suggests that pulses as short as ∼0.5 ps with multi-GW peak power can be generated in a mixture of CO 2 isotopes. Robustness of the output of a compact CO 2 regenerative amplifier to the seed and pump fluctuations measured at 3 Hz and a perfect Gaussian beam profile indicates the potential of such laser technology for producing high-power ultrashort long-wave infrared pulses at high repetition rates.

43 PARTICLE ACCELERATORS

Untangling Sources of Error in the Density-Functional Many-Body Expansion

The many-body expansion provides a framework for data-driven applications of electronic structure theory, including parametrization of classical force fields and machine learning. In this article, we demonstrate that its use significantly amplifies quadrature grid errors when modern density-functional approximations are employed. Standard grids that work well in conventional density-functional calculations result in runaway error accumulation when used with the many-body expansion. At the same time, delocalization error is also exacerbated, leading to exaggerated estimates of nonadditive n-body interactions. This is illustrated for anion–water clusters using the SCAN, r2SCAN, ωB97X-V and ωB97M-V functionals. By employing dense quadrature grids, the inherent self-interaction error is exposed, which can then be mitigated using a variety of other strategies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH