Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wind-induced torsion of parabolic trough collectors in operation

Parabolic trough collector (PTC) systems, a type of concentrating solar power (CSP), use parabolic mirrors to reflect the sun's rays toward an absorber tube to heat the fluid inside. PTCs track the sun throughout the day and are sensitive to angular misalignment, which reduces optical performance. Torsion of the PTC, exacerbated by wind loading, contributes to angular misalignment, which has been quantified by previous studies using numerical simulations and experimental tests. However, angular misalignment due to torsion and wind loading has not yet been studied in an operational plant, which can experience more extreme and variable conditions. This study characterizes the angular misalignment due to torsion at three rows of the Nevada Solar One CSP plant and investigates the influence of wind loading. These findings reveal substantial torsion along the PTC support structure that depends on wind conditions and orientation. Strong winds perpendicular to the PTCs increase the median angular displacement of the outermost row by up to 18 mrad and increase the standard deviation by up to 8 mrad when compared to weak wind conditions. These findings can inform enhanced PTC design, controls and modeling that will improve the performance, reliability and bankability of future CSP plants.

14 SOLAR ENERGY

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY

Characterization of wind conditions and impact on wind loading at an operational parabolic trough concentrating solar power plant using LiDAR observations

Wind loading is a major factor influencing the structural design costs of Concentrating Solar Power (CSP) collector systems, including heliostats and parabolic troughs. Traditionally, these designs have been based on wind-tunnel data, which often fail to accurately represent the dynamic effects experienced at full scale. This study presents a first-of-its-kind experimental characterization of wind conditions within an operational parabolic-trough CSP power plant focusing specifically on using lidar observations. The lidar observations give a unique opportunity to provide insights into wind flow conditions deep within the trough arrays. Our results suggest that (1) after being blocked by the first few rows, the wind speed above the troughs recovers to 73% of its inflow magnitude as it flows further over the trough field due to enhanced turbulent mixing and (2) due to the wind speed recovery, troughs in the interior field will likely experience higher shear-induced turning moments compared those at the front. The conclusions from this work stress the importance of better understanding the wind patterns and interior wind loads when designing solar collectors and highlights the need for more interior load measurements in the future field campaigns.

17 WIND ENERGY

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY

Wind Loading on CSP Collectors

The project significantly enhanced the community's understanding of the fundamental physics drivers underlying the wind-loading experienced by concentrating solar power (CSP) collector structures (i.e., parabolic troughs and heliostats) as well as their support structures. This project had two overarching objectives: (1) detailed measurements to characterize the prevailing wind conditions and resulting operational loads on collector structures, and (2) development and validation of a computationally efficient, high-fidelity modeling tool capable of predicting wind-loading in deep-array installations. Over three years, we conducted comprehensive at-scale field measurements of the atmospheric turbulent wind conditions, and the resulting wind loads on parabolic troughs and heliostats. Two at-scale measurement campaigns yielded first-of-its-kind, high-resolution, long-term datasets that are used to characterize the complex flow field and wind loading on parabolic-troughs and heliostats in operational power plants. The high-resolution measurements collected during these campaigns were used to validate the high-fidelity computational models developed at NREL. These open-source computationally efficient models were shown to be accurate in predicting wind-driven loads on collectors without the need for a large supercomputer.

14 SOLAR ENERGY

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP

The effects of regional insolation differences upon advanced solar thermal electric power plant performance and energy costs

This paper presents the performance and cost of four 10-MWe advanced solar thermal electric power plants sited in various regions of the continental United States. Each region has different insolation characteristics which result in varying collector field areas, plant performance, capital costs, and energy costs. The paraboloidal dish, central receiver, cylindrical parabolic trough, and compound parabolic concentrator (CPC) comprise the advanced concepts studied. This paper contains a discussion of the regional insolation data base, a description of the solar systems' performances and costs, and a presentation of a range for the forecast cost of conventional electricity by region and nationally over the next several decades.

Latta, A. F.

Measurement of Wind Loading on Heliostats at the Crescent Dunes Power Plant: An Overview

The cost of solar collectors constitutes almost one third of the total cost of a CSP plant. One of the ongoing challenges in the design of these collectors is wind loading on mirrors, support structures, and drives. A particular challenge is dynamic wind loading, caused by the turbulent wind flow. To date, the design of solar collector structures has relied on wind tunnel experiments and numerical simulations that do not entirely capture the dynamic effects observed at scale. The CSP industry has shown increased interest in validating the idealized assumptions with measurements obtained in operational settings to improve wind load assumptions and increase reliability and cost-efficiency of the collector design. Further, performance models need realistic assumptions about wind loading and its impact on optical performance. In a parabolic trough field campaign, NREL successfully collected a wealth of long-term, high-resolution wind and loads data [2], that are publicly available and that can be used for the above-mentioned purposes. Heliostats are impacted differently by wind than parabolic troughs, due to their different shape, size, and field layout. To study the impact of wind and turbulence on heliostats, we initiated another field campaign in an operational power- tower plant, Crescent Dunes, in Nevada, USA. In this work, we present an overview of the measurements, first results, and potential implications of wind driven loads on Heliostats.

concentrated solar power

Operational Experience from Solar Thermal Energy Projects

Over the past few years, Sandia National Laboratories were involved in the design, construction, and operation of a number of DOE-sponsored solar thermal energy systems. Among the systems currently in operation are several industrial process heat projects and the Modular Industrial Solar Retrofit qualification test systems, all of which use parabolic troughs, and the Shenandoah Total Energy Project, which uses parabolic dishes. Operational experience has provided insight to both desirable and undesirable features of the designs of these systems. Features of these systems which are also relevant to the design of parabolic concentrator thermal electric systems are discussed. Other design features discussed are system control functions which were found to be especially convenient or effective, such as local concentrator controls, rainwash controls, and system response to changing isolation. Drive systems are also discussed with particular emphasis of the need for reliability and the usefulness of a manual drive capability.

Cameron, C. P.

Projection of distributed-collector solar-thermal electric power plant economics to years 1990-2000

A preliminary comparative evaluation of distributed-collector solar thermal power plants was undertaken by projecting power plant economics of selected systems to the 1990 to 2000 time frame. The selected systems include: (1) fixed orientation collectors with concentrating reflectors and vacuum tube absorbers, (2) one axis tracking linear concentrator including parabolic trough and variable slat designs, and (3) two axis tracking parabolic dish systems including concepts with small heat engine-electric generator assemblies at each focal point as well as approaches having steam generators at the focal point with pipeline collection to a central power conversion unit. Comparisons are presented primarily in terms of energy cost and capital cost over a wide range of operating load factors. Sensitvity of energy costs for a range of efficiency and cost of major subsystems/components is presented to delineate critical technological development needs.

Fujita, T.

Analysis and conceptual design of a lunar radiator parabolic shade

On the moon, the available heat sink temperature for a vertical unshaded radiator at the equator is 322 K. A method of reducing this heat sink temperature using a parabolic trough shading device was investigated. A steady state heat balance was performed to predict the available heat sink temperature. The effect of optical surface properties on system performance was investigated. Various geometric configurations were also evaluated. A flexible shade conceptual design is presented which greatly reduces the weight and stowed volume of the system. The concept makes use of the natural catenary shape assumed by a flexible material when supported at two points. The catenary shape is very near parabolic. The lunar radiator parabolic shade design presented integrates the energy collection and rejection of a solar dynamic power cycle with the moderate temperature waste heat rejection of a lunar habitat.

Ewert, Michael K.

Assessment of the polygeneration approach in wastewater treatment plants for enhanced energy efficiency and green hydrogen/ammonia production

Wastewater treatment plants (WWTPs) offer opportunities to optimize resource utilization and enhance energy efficiency. Here, this study provides a comprehensive analysis of using the polygeneration approach in WWTPs to reduce grid energy dependence, optimize energy distribution, and utilize surplus energy for hydrogen (H 2 ) and ammonia (NH 3 ) production. Several models were employed, including photovoltaic (PV) cells, parabolic trough collectors (PTCs), steam methane reforming, and polymer electrolyte membranes, to assess the feasibility of this approach. Three scenarios were evaluated and compared: Scenario 1 (Baseline) represents the current situation, Scenario 2 maximizes the Net Present Value (NPV), and Scenario 3 minimizes NH 3 production costs. Real data from As-Samra WWTP in Jordan was used to accurately assess the feasibility of each scenario. The results show that Scenario 2 offers the highest profitability and efficiency, with a NPV of 87.48 million USD and an annual NH 3 production of 15,417 tons, reducing both grid dependency and biogas fuel consumption. Both Scenarios 2 and 3 demonstrate the ability to meet thermal demands efficiently while generating significant revenue from NH 3 production. Scenario 3, in particular, achieves competitive H 2 and NH 3 production costs. Environmentally, Scenario 2 significantly reduces annual greenhouse gas emissions by 12.66 kilotons of CO 2eq , with near-zero carbon intensity for thermal energy due to solar reliance. In conclusion, the polygeneration approach offers a promising pathway for WWTPs to achieve greater sustainability, economic gains, and reduced environmental impact, providing valuable insights for decision-makers.

42 ENGINEERING

A polarimetry-based field-deployable non-interruptive mirror soiling detection method

The soiling level of heliostat mirrors in Concentrated Solar Power (CSP) fields is one of the key factors that significantly influences optical efficiency. State-of-the-art methods of monitoring heliostats soiling levels still face various challenges, including slow speed, labor-intensive operations, resolution and accuracy constraints or interruptions to solar field operations. Here, we present a rapid, cost-effective, and non-intrusive method for mirror soiling detection based on polarimetric imaging, referred to as Polarimetric Imaging-based Mirror Soiling (PIMS). The compact PIMS device is designed for integration with unmanned aerial vehicles (UAVs), enabling rapid, large-area assessments of heliostat mirrors for efficient soiling detection. Our method utilizes the correlation between the Degree of Linear Polarization (DoLP) and surface soiling level based on Mie scattering theory and Monte Carlo simulations. Field deployment of the PIMS method requires minimal device installation, and its UAV-based operation allows for soiling detection without interrupting plant activities. The PIMS method holds the potential for mirror soiling detection across various concentrated solar power (CSP) plants and can be further adapted for other types of solar fields, such as parabolic trough systems.

CSP Field

Wind Conditions for Solar Energy Facility Design Based on Field Measurements at Nevada Solar One

This study characterises near-surface wind conditions at the Nevada Solar One (NSO) concentrated solar power plant using two years of measurements from a 15-m mast located 30 m west of the solar arrays. The surrounding terrain is fairly flat within 3 km, but nearby solar photovoltaic (PV) and concentrated solar power (CSP) installations introduce strong directional wind inhomogeneity, which motivates a sector-based analysis that distinguishes undisturbed inflow from waked flow. The analysis uses data from three sonic anemometers to assess whether turbulence in the surface layer can be represented as Gaussian and whether standard surface-layer scaling remains valid below 10 m height. The roughness length and displacement height are estimated for twelve directional sectors under near-neutral wind conditions, and all three velocity components show departures from Gaussian behaviour. Spectral analysis indicates that the turbulence contains low-frequency fluctuations with amplitudes higher than those predicted by standard models such as the Kaimal model or the Simiu and Scanlan model. The study introduces a new turbulence spectral model based on the eddy-surface-layer framework to better represent near-surface wind turbulence. The analysis further quantifies the influence of the surrounding power plants on mean wind profiles, one-point spectra, and vertical coherence for all velocity components. The solar collector arrays located 30 m east of the mast significantly modify the turbulence structure, whereas PV installations situated a few hundred metres away have only a limited influence on the turbulence measured at the mast. These findings highlight the limitations of conventional turbulence models for near-surface wind over solar infrastructure and provide improved parameterisations to support the structural design. The implications for the structural response of parabolic troughs and PV modules to such turbulence remain uncertain and require further investigation.

14 SOLAR ENERGY

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE

First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis

The First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis (aka the STEP 1 Project or the Project) aimed to (1) developed a brand-new web tool that could provide decision support through free, rapid techno-economic analysis of behind-the-meter solar+storage systems for industrial process heat and (2) conduct high-level analyses of the cost-competitiveness of the same systems across the US in key sectors. The STEP 1 web tool collects key location, land availability, thermal load profile, proccess heat temperature and media, and other key parameters through an easy-to-use user interface (UI). The UI was designed to meet the user at their level of understanding by minimizing the number of required inputs as much as possible while including options for more nuanced inputs if the user desires. STEP 1 advises users on which solar thermal tehcnologies that could fit their needs based on the inputs provided (namely process media and temperature). The tool can model a wide range of solar thermal technologies including flat plate collectors, evacuated tubes, parabolic troughs, linear Fresnel, and molten salt towers all with corresponding thermal energy storage (TES) - solar PV with resistive heating and TES is also included. Once the parameters are collected, a nominal thermal energy production profile for the facility's location is generated using NREL's System Advisory Model (SAM) and then passed to a modified version of NREL's REopt platform to optimize the size (capacity) and dispatch of the solar+storage system to minimize lifecycle costs subject to energy balance, fuel and electricity rates, emission reductions goals, and other constraints. This entire process takes less than 20 minutes, is completely free, requires zero coding skills, and provides the user with a high-level assessment on the techno-economic feasability of deploying solar+storage systems for their energy needs. In addition to the development of the STEP 1 web tool, the project completed two complementary analyses focused on leveraging the backend code of STEP 1, public industrial facility locations and fuel consumption data, and key sector information to assess the economic opportunity of reducing fuel costs at various levels of capacity factor around the US. Both analyses found that there are key markets, locations, industrial sectors (namely food and beverage), and degrees of offset where solar thermal technologies could be cost-effectively deployed, highlighting a key market entry point for these technologies, and assessing deployment potential. In summary, the STEP 1 project improved the opportunities for solar+storage systems to expand into the industrial process heat market through breaking down barriers to assessing these technologies.

14 SOLAR ENERGY