Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outage survivability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage

The energy system infrastructure that delivers power to a building's loads needs to be resilient to withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

ReNew100: Reliable Power System Operation with 100% Renewable Generation

The ReNew100 project has developed and demonstrated an operator support system (OSS) to operate power systems with 100% renewable power generation from inverter-based resources (IBRs) like wind and solar that significantly reduces the risk of widespread power outages in a simulated operational environment at Technology Readiness Level (TRL) 6. The OSS achieves resilient operation for power systems under changing operation modes including varying combinations of conventional and renewable generation, including cases with 100% renewable generation from wind and solar IBRs. The OSS continuously monitors the N-1 security of the power system, which refers to the ability of the power systems to survive single outages of power system elements, like the loss of a generator or a power line, without causing widespread power outages beyond those expected and planned for. If the OSS identifies that the system is not N-1 secure, an automatic Controller Parameter Optimization (CoPO) developed within Renew100 is activated to optimize the N-1 security of the system by tuning controller parameters within different assets like batteries, wind, and solar plants. The core innovation of ReNew100 is the development of this CoPO as well as the demonstration of the OSS for a real-time simulation of the Hawai'i Island power system. Moreover, Renew100 has developed new model calibration techniques for dynamic power system models and demonstrated them for Hawai'i Island.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SEIN: Breaking Barriers Resilient Energy System Analysis [Slides]

The Solar Energy Innovation Network (SEIN) is a collaborative research program that supports multi-stakeholder teams in researching and sharing solutions to real-world challenges associated with solar energy adoption. The Breaking Barriers project was selected to participate in the Solar Energy Innovation Network, Round 2, and was led by Groundswell, a D.C.-based clean energy project developer. The Breaking Barriers team included Partnership for Southern Equity, Atlanta University Center campus facility managers and professors, the City of Atlanta's Neighborhood Planning Unit T, and Georgia Power Company. The project aimed to design and construct innovative urban energy resiliency hubs integrating microgrid technology, solar generation, and energy storage in Atlanta colleges and communities. The hubs will help these historically Black colleges and universities (HBCUs) and the energy-burdened broader community in West Atlanta be more resilient, in addition to informing new course curricula at Atlanta University Center campuses. With many possible options for the system's battery size, the Breaking Barriers team needed insight into the relationships between BESS size, economic performance, and resilience at Spelman College's Manley Center. These insights are crucial for entering procurement negotiations with project developers, establishing resilience capabilities that the HBCU campuses can plan around, and guiding the team's fundraising targets. This analysis includes estimates of PV and battery performance, costs, savings, and resilience for multiple battery sizes. In order to provide power during a grid outage, the resilient energy system also needs to be connected to the Manley Center in a safe and island-able manner (electrically isolated from the grid). Analysis of potential electrical configurations and estimated setup costs is key to successfully entering a required interconnection agreement with Georgia Power, as well as informing requests for engineering firms to construct the system. This analysis includes conceptual options and rough order of magnitude cost estimates for electrically interconnecting the resilient energy system to the Manley Center and the grid. The Breaking Barriers team used this analysis to select preferred system characteristics and design for the resilient energy system.

14 SOLAR ENERGY↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-tlie-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-the-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Evaluation of the Economic and Resilience Benefits of a Microgrid in Northampton, Massachusetts

Recent developments and advances in distributed energy resource (DER) technologies make them valuable assets in microgrids. This paper presents an innovative evaluation framework for microgrid assets to capture economic benefits from various grid and behind-the-meter services in grid-connecting mode and resilience benefits in islanding mode. In particular, a linear programming formulation is used to model different services and DER operational constraints to determine the optimal DER dispatch to maximize economic benefits. For the resiliency analysis, a stochastic evaluation procedure is proposed to explicitly quantify the microgrid survivability against a random outage, considering uncertainties associated with photovoltaic (PV) generation, system load, and distributed generator failures. Optimal coordination strategies are developed to minimize unserved energy and improve system survivability, considering different levels of system connectedness. The proposed framework has been applied to evaluate a proposed microgrid in Northampton, Massachusetts that would link the Northampton Department of Public Works, Cooley Dickenson Hospital, and Smith Vocational Area High School. The findings of this analysis indicate that over a 20-year economic life, a 441 kW/441 kWh battery energy storage system, and 386 kW PV solar array can generate $2.5 million in present value benefits, yielding a 1.16 return on investment ratio. Results of this study also show that forming a microgrid generally improves system survivability, but the resilience performance of individual facilities varies depending on power-sharing strategies.

25 ENERGY STORAGE↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Design of the Lanthanum hexaboride based plasma source for the large plasma device at UCLA

The Large Plasma Device (LAPD) at UCLA (University of California, Los Angeles) produces an 18 m long, magnetized, quiescent, and uniform plasma at a high repetition rate to enable studies of fundamental plasma physics. Here, we report on a major upgrade to the LAPD plasma source that allows for more robust operation and significant expansion of achievable plasma parameters. The original plasma source made use of a heated barium oxide (BaO) coated nickel sheet as an electron emitter. This source had a number of drawbacks, including a limited range of plasma density (≲4.0 × 10 12 cm −3 ), a limited discharge duration (∼10 ms), and susceptibility to poisoning following oxygen exposure. Further, the new plasma source utilizes a 38 cm diameter lanthanum hexaboride (LaB 6 ) cathode, which has a significantly higher emissivity, allowing for a much larger discharge power density, and is robust to exposure to air. Peak plasma density of up to 3.0 × 10 13 cm −33 in helium gas has been achieved. The typical operating pressure is ∼10 −5 Torr, while dynamic pressure can be achieved through the gas-puffing technique. Discharges as long as 70 ms have been produced, enabling a variety of long-time-scale studies of processes, such as turbulent particle transport. The new source has been in continuous operation for 14 months, having survived air leaks, power outages that led to rapid temperature changes on the cathode and heater, and planned machine openings. We describe the design, construction, and initial operation of this novel new large-area LaB6 plasma source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Individual and Collective Strategies to Limit the Impacts of Large Power Outages of Long Duration

As modern society becomes ever more dependent on the availability of electric power, the costs that could arise from individual and social vulnerability to large outages of long duration (LLD-outages) increases. During such an outage, even a small amount of power would be very valuable. Here, this article compares individual and collective strategies for providing limited amounts of electric power to residential customers in a hypothetical New England community during a large electric power outage of long duration. We develop estimates of the emergency load required for survival and assess the cost of strategies to address outages that last 5, 10, and 20 days in either winter or summer. We find that the cost of collective solutions could be as much as 10 to 40 times less than individual solutions (less than $2 per month per home). However, collective solutions would require community-wide coordination, and if local distribution system lines are destroyed, only individual back-up systems could provide contingency power until those lines are repaired. Costs might be reduced if more robust distributed generation were employed that could be operated continuously with the ability to sell power back to the grid. Our cost-effectiveness analysis only assesses what could be done, developing estimates of preparedness cost. A decision about what should be done would require additional input from a range of stakeholders as well as some form of analytical deliberative process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Water Network Tool for Resilience (WNTR)

The Water Network Tool for Resilience (WNTR) is an open source Python package designed to simulate and analyze resilience of water distribution networks. The United States Environmental Protection Agency, in partnership with Sandia National Laboratories, developed WNTR to integrate critical aspects of resilience modeling for water distribution networks into a single software framework. The software includes capability to: • Generate water network models • Modify network structure and operations • Assign fragility and survival curves to network components • Model disruptive events such as power outages, earthquakes, fires, pipe breaks, and contamination incidents • Model response and repair strategies • Simulate hydraulics and water quality • Evaluate resilience using a wide range of metrics • Integrate dependency with other critical infrastructure and supply chains • Analyze results and generate graphics SAND2019-450 M

Villa, Daniel↗

Feasibility Assessment of Using Electrical Impedance Tomography for Damage Localization in Graphite Microreactor Components

Microreactors have great potential to decrease capital costs and construction timelines, reducing the barriers to implementing advanced nuclear reactor technologies. However, the lower power output of these microreactors introduces economic challenges if the operation and maintenance costs cannot be reduced sufficiently. Many microreactor concepts use graphite materials for in-core moderator and structural purposes, which will require periodic inspection or, ideally, in situ structural health monitoring. This work describes an initial evaluation of the feasibility of leveraging graphite’s semiconducting properties to perform electrical impedance tomography (EIT) for defect localization. First, a study was performed to identify the best methods for bonding electrical contacts to minimize the effects of contact resistance that interfere with impedance measurements of the graphite. After determining the best bonding approach, electrodes were attached to multiple graphite components with varying geometries (e.g., simple block and more representative microreactor hexagonal block). In parallel, finite element analysis approaches were developed and implemented to analyze the impact of defects and contact resistances and to inform an iterative inverse model for reconstructing the conductivity distribution. The results of this study show that defect localization in graphite components is possible using EIT if a sufficient number of electrodes (to improve spatial resolution) can be bonded using a technique with very low contact resistance and those contact resistances remain stable during reactor operation. If the reactor core and vessel design do not allow electrodes to be bonded during reactor operation, then it may be possible to detach/reattach electrodes between reactor operation and outages if a suitable mechanical connection that offers repeatable contact resistance can be identified. Alternatively, future work could focus on identifying contacts that can survive the harsh reactor operating environment so that contacts do not need to be removed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Dynamic Transmission Line Switching Amid Wildfire-Prone Weather Under Decision-Dependent Uncertainty

During dry and windy seasons, environmental conditions significantly increase the risk of wildfires, exposing power grids to disruptions caused by transmission line failures. Wildfire propagation exacerbates grid vulnerability, potentially leading to prolonged power outages. To address this challenge, we propose a multistage optimization model that dynamically adjusts transmission grid topology in response to wildfire propagation, aiming to develop an optimal response policy. By accounting for decision-dependent uncertainty, where line survival probabilities depend on usage, we employ distributionally robust optimization to model uncertainty in line survival distributions. We adapt the stochastic nested decomposition algorithm and derive a deterministic upper bound for its finite convergence. To enhance computational efficiency, we exploit the Lagrangian dual problem structure for a faster generation of Lagrangian cuts. Using realistic data from the California transmission grid, we demonstrate the superior performance of dynamic response policies against two-stage alternatives through a comprehensive case study. In addition, after solving the multistage formulation, we construct easy-to-implement policies that significantly reduce computational burden while maintaining good performance in real-time deployment. History: Accepted by Russell Bent, Area Editor for Network Optimization: Algorithms and Applications. Funding: This work was supported by the U.S. Department of Energy, Office of Electricity [Grant DE-AC02-05CH11231]. The work of R. Jiang was supported in part by the U.S. National Science Foundation, Division of Electrical, Communications and Cyber Systems [Grant ECCS-1845980] and the U.S. Air Force Office of Scientific Research [Grant FA9550-23-1-0323]. Supplemental Material: The software that supports the findings of this study is available within the paper and its Supplemental Information ( https://pubsonline.informs.org/doi/suppl/10.1287/ijoc.2025.1210 ) as well as from the IJOC GitHub software repository ( https://github.com/INFORMSJoC/2025.1210 ). The complete IJOC Software and Data Repository is available at https://informsjoc.github.io/ .

Estrada-Garcia, Juan-Alberto↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗