Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimisation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimisation of dynamic reactive power sources using mesh adaptive direct search

Dynamic reactive power sources can be used to effectively mitigate the fault-induced delayed voltage recovery and transient voltage instability issues. When many var sources need to be installed at planned locations, optimisation of their sizes is a complicated non-linear optimisation problem due to its non-convexity and the dependence of the constraint on time-series trajectories of post-fault voltages. Solving this optimal sizing problem needs to utilise both a non-linear optimisation solver and a power system differential-algebraic equation solver. This study proposes a new approach for solving this problem under both a single contingency and multiple contingencies by using the mesh adaptive direct search algorithm interfaced with a power system simulator. The proposed approach is validated by case studies on a North American Eastern Interconnection model to optimise the sizes of planned STATCOMs against critical contingencies.

Huang, Weihong↗

Decentralised optimisation of cogeneration in virtual power plants

Within several projects we investigated grid structures and management strategies for active grids with high penetration of renewable energy resources and distributed generation (RES and DG). Those ''smart grids'' should be designed and managed by model based methods, which are elaborated within these projects. Cogeneration plants (CHP) can reduce the greenhouse gas emissions by locally producing heat and electricity. The integration of thermal storage devices is suitable to get more flexibility for the cogeneration operation. If several power plants are bound to centrally managed clusters, it is called ''virtual power plant''. To operate smart grids optimally, new optimisation and model reduction techniques are necessary to get rid with the complexity. There is a great potential for the optimised management of CHPs, which is not yet used. Due to the fact that electrical and thermal demands do not occur simultaneously, a thermally driven CHP cannot supply electrical peak loads when needed. With the usage of thermal storage systems it is possible to decouple electric and thermal production. We developed an optimisation method based on mixed integer linear programming (MILP) for the management of local heat supply systems with CHPs, heating boilers and thermal storages. The algorithm allows the production of thermal and electric energy with a maximal benefit. In addition to fuel and maintenance costs it is assumed that the produced electricity of the CHP is sold at dynamic prices. This developed optimisation algorithm was used for an existing local heat system with 5 CHP units of the same type. An analysis of the potential showed that about 10% increase in benefit is possible compared to a typical thermally driven CHP system under current German boundary conditions. The quality of the optimisation result depends on an accurate prognosis of the thermal load which is realised with an empiric formula fitted with measured data by a multiple regression method. The key functionality of a virtual power plant is to increase the value of the produced power by clustering different plants. The first step of the optimisation concerns the local operation of the individual power generator, the second step is to calculate the contribution to the virtual power plant. With small extensions the suggested MILP algorithm can be used for an overall EEX (European Energy Exchange) optimised management of clustered CHP systems in form of the virtual power plant. This algorithm has been used to control cogeneration plants within a distribution grid. (author)

20 FOSSIL-FUELED POWER PLANTS↗

Land surface model parameter optimisation using in situ flux data: comparison of gradient-based versus random search algorithms (a case study using ORCHIDEE v1.9.5.2)

Land surface models (LSMs), which form the land component of earth system models, rely on numerous processes for describing carbon, water and energy budgets, often associated with highly uncertain parameters. Data assimilation (DA) is a useful approach for optimising the most critical parameters in order to improve model accuracy and refine future climate predictions. In this study, we compare two different DA methods for optimising the parameters of seven plant functional types (PFTs) of the ORCHIDEE LSM using daily averaged eddy-covariance observations of net ecosystem exchange and latent heat flux at 78 sites across the globe. We perform a technical investigation of two classes of minimisation methods – local gradient-based (the L-BFGS-B algorithm, limited memory Broyden–Fletcher–Goldfarb–Shanno algorithm with bound constraints) and global random search (the genetic algorithm) – by evaluating their relative performance in terms of the model–data fit and the difference in retrieved parameter values. We examine the performance of each method for two cases: when optimising parameters at each site independently (“single-site” approach) and when simultaneously optimising the model at all sites for a given PFT using a common set of parameters (“multi-site” approach). We find that for the single site case the random search algorithm results in lower values of the cost function (i.e. lower model–data root mean square differences) than the gradient-based method; the difference between the two methods is smaller for the multi-site optimisation due to a smoothing of the cost function shape with a greater number of observations. The spread of the cost function, when performing the same tests with 16 random first-guess parameters, is much larger with the gradient-based method, due to the higher likelihood of being trapped in local minima. When using pseudo-observation tests, the genetic algorithm results in a closer approximation of the true posterior parameter value in the L-BFGS-B algorithm. We demonstrate the advantages and challenges of different DA techniques and provide some advice on using it for the LSM parameter optimisation.

58 GEOSCIENCES↗

Waste is our Product. Developing, Implementing and Optimising Waste Management at Dounreay - 19039

The UK's Fast Breeder Reactor Research programme was centred at Dounreay, in the very north of Scotland, from 1955. Since 1994, the site has been focused on decommissioning, and represents one of the most complex, technically challenging and hazardous nuclear clean-up projects in Europe. Since 2012, Dounreay Site Restoration Ltd (DSRL) has been contracted by the NDA as the Site License Company to deliver the defined scope of work, under a Target Cost contract, to decommission the site to achieve the Interim End State by 2030-2033, whilst managing the transition of its people. All parties, including DSRL's Parent Body Organisation Cavendish Dounreay Partnership Ltd (a consortium of Cavendish Nuclear, AECOM, and Jacobs), recognise that there are significant technical and regulatory challenges to achieve this, as well as safely managing the transition for our workforce on what is effectively a 'closure' contract. The product of decommissioning is waste; over the course of the programme, a full range of higher activity and lower level radioactive wastes will be generated, and must be safely managed. This paper will address: - The Policy issues relating to radioactive waste management at Dounreay, including particular issues relating to implementation of Scottish policy, including how Waste Management is Optimised. - An overview of the decommissioning programme and the delivery of an Interim End State; - The type, range and nature of radioactive wastes requiring safe management at Dounreay; - Higher Activity Wastes (HAW): - Setting higher activity waste strategy; defining products and interim storage requirements; - Technical, regulatory and stakeholder issues for HAW strategy; - Lower Activity Wastes: - Setting Low Level Waste (LLW) strategy; defining a disposal product and development and status for Dounreay's LLW Disposal Vaults; - Implementing LLW strategy; - Technical, regulatory and stakeholder issues for LLW strategy; - Optimising Waste Management -Optimising waste from generation (from decommissioning workfaces) through to disposal -why, and how; - The Waste Informed Decommissioning model as a methodology and approach; - Impact and importance of Waste Management on a target cost contract; - Establishment of a Waste Optimisation Programme to drive ownership, delivery and culture change; - Management responsibilities and informing organisational design; - Sharing and learning from Best Practice; - The Challenge - how to ensure workforce and teams are engaged in delivering optimisation requirements; - Conclusions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Supporting mobile WEEE collection on demand: A method for multi-criteria vehicle routing, loading and cost optimisation

Highlights: • Multi-criteria method of WEEE mobile collection on demand. • Vehicle routing and loading problem included in the model and algorithm. • Optimisation of collecting vehicles routes including genetic algorithms and fuzzy logic. • Case study for heterogeneous fleet of collection vehicles for medium size city in Poland. • Possible application in a software supporting waste collection on demand. - Abstract: The task of increasing collection rates of waste electrical and electronic equipment (WEEE) is an important challenge in the global economy, and especially in the European Union where stiffer collection targets set out in a new WEEE directive are to be effective by 2019. As the circular economy approach replaces the linear model, resource recycling activities become a priority in waste management policy. As new techniques and possibilities of waste collection systems emerge, opportunities are created for improving efficiency for collection companies and affording benefits for the environment. A model proposed for mobile WEEE collection in this study considers a multi-criteria approach in developing a cost efficient method for pick up on demand from residents or electrical and electronic equipment (EEE) stores. The algorithm used in this model optimises vehicle routes and helps in selecting a number of vehicles from a heterogeneous fleet, incorporating the WEEE loading problem. Using genetic algorithm and fuzzy logic, this model optimises costs and resources required to complete the WEEE collection assuring timely pick up of the waste equipment. The numerical model is verified in a case study in Opole, a city in the south of Poland. The results show that the proposed model can handle the multiple parameter optimisation problem including operational costs, efficient use of vehicles from a fleet, efficient waste loading in vehicles and residents' satisfaction with timely pick up of the waste equipment from a household. Such system can be successfully applied even for large cities. The algorithm provides an opportunity for writing software or mobile apps design to be used by WEEE collection companies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A data-driven network optimisation approach to coordinated control of distributed photovoltaic systems and smart buildings in distribution systems

The increasing integration of distributed energy resources, including demand-side resources and distributed photovoltaics (PVs), into distribution systems has resulted in more complicated power system operation. A data-driven network optimisation approach is proposed to coordinate the control of distributed PVs and smart buildings in distribution networks considering the uncertainties of solar power, outdoor temperature and heat gain associated with building thermal dynamics. These uncertain parameters have a significant impact on the operation and control of distributed PVs and smart buildings, bringing challenges to the distribution system operation. In the proposed data-driven distributionally robust optimisation (DRO) approach, the Wasserstein ball is used to construct an ambiguity set for the uncertain parameters, which does not require the probability distributions to be known. Furthermore, a conditional value-at-risk is incorporated into the Wasserstein-based DRO model and converted into a computationally tractable mixed-integer convex optimisation problem. Benchmarked with robust optimisation and chance-constrained programming, the proposed data-driven model can give a less conservative robust solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability-based hull geometry optimisation of a point-absorber wave energy converter with power take-off structural reliability objectives

Recent studies have focused on optimising wave energy converter (WEC) designs, maximising their power performance and techno-economic feasibility. Reliability has yet to be fully considered in these formulations, despite its impact on cost and performance. In this study, this gap is addressed by developing a reliability-based design optimisation framework for WEC hull geometries to explore the trade-off between power performance and power take-off (PTO) system damage equivalent loading (DEL). Optimised hull geometries for two sites are considered (from the centre of the North Sea and off the west coast of Norway), and two directions of motions (heave and surge). Results indicate that site characteristics affect the potential power production and DEL for an optimal WEC design. These are also affected by the direction of motion for power extraction, which also significantly changes optimal hull shape characteristics. Optimal surging WEC designs have edges facing oncoming wave directions, while heaving WECs have pointed bottoms, both to streamline movement. Larger, more convex WECs result in greater power production and DEL, while smaller, more concave WECs result in lesser power production and DEL. These findings underline the importance of considering WEC hull geometry in early design processes to optimise cost, power production, and reliability.

16 TIDAL AND WAVE POWER↗

Optimisation of the Kaplan hydropower system via PID 2 and digital twin

Here, this paper proposes a proportional–integral-double–derivative (PID 2 ) optimisation method for the Kaplan hydropower system by building a digital twin. The study first uses one multilayer perceptron (MLP) to model the hydroturbine dynamic and then adopts three connected MLPs to model the generator dynamic, both in an open-loop fashion. Inspired by stochastic distribution control (SDC) theory, we regard the training of the turbine's neural network model as a process control problem, and we propose minimising entropy loss to update the network parameters. The next step is to build the digital twin by connecting the neural network models with a PID 2 controller and a lead-lag exciter and run the whole model in a closed-loop fashion. After that, a binary search approach is applied to optimise the PID 2 parameters based on the obtained digital twin model. The simulation results show that the proposed method can reduce the mean square tracking error by more than 90%. Furthermore, the method is extended to jointly optimise the PID 2 controller and excitation system gains through multiobjective optimisation, leveraging Pareto frontier analysis to balance active power and voltage tracking performance. Simulation results confirm the effectiveness of the proposed method, achieving a 83.46% reduction in relative mean square error of active power, a 47.13% reduction in terminal voltage tracking error, and an 82.78% improvement in the overall scalarized objective.

Hydropower system↗

Multidisciplinary design analysis and optimisation of a reference offshore wind plant

Motivated by the need to develop reference wind energy systems for optimisation and technology assessment studies, the International Energy Agency Wind Task 37 on Wind Energy Systems Engineering is developing a reference offshore wind power plant at the Dutch offshore wind energy areas Borssele III and IV. This work presents a comparison between two approaches for developing the preliminary design of an offshore wind plant turbine layout, electrical collection system, and support structures. The first is a sequential approach, where components of the wind farm are optimised sequentially, each with its own objective function, thus neglecting potential interactions between them. The second approach uses Multidisciplinary Design Analysis and Optimisation (MDAO), where all components are jointly optimised with the overall system levelised cost of energy (LCOE) as a global objective function. Studying the cases of regular and irregular layouts, the integrated approach always shows a greater improvement in the LCOE of the final design compared to the design resulting from the traditional sequential approach. The most significant trade-off exploited by the MDAO approach used in this study is between losses in energy production due to turbine wake effects and the costs of electrical cable infrastructure.

17 WIND ENERGY↗

Optimisation of the Management of Higher Activity Waste in the UK - 13537

The Upstream Optioneering project was created in the Nuclear Decommissioning Authority (UK) to support the development and implementation of significant opportunities to optimise activities across all the phases of the Higher Activity Waste management life cycle (i.e. retrieval, characterisation, conditioning, packaging, storage, transport and disposal). The objective of the Upstream Optioneering project is to work in conjunction with other functions within NDA and the waste producers to identify and deliver solutions to optimise the management of higher activity waste. Historically, optimisation may have occurred on aspects of the waste life cycle (considered here to include retrieval, conditioning, treatment, packaging, interim storage, transport to final end state, which may be geological disposal). By considering the waste life cycle as a whole, critical analysis of assumed constraints may lead to cost savings for the UK Tax Payer. For example, it may be possible to challenge the requirements for packaging wastes for disposal to deliver an optimised waste life cycle. It is likely that the challenges faced in the UK are shared in other countries. It is therefore likely that the opportunities identified may also apply elsewhere, with the potential for sharing information to enable value to be shared. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimising the Performance of the Low Level Waste Repository - 12144

The Low Level Waste Repository (LLWR) is the United Kingdom's principal facility for the disposal of low-level waste (LLW). The LLWR made a major submission to its environmental regulator (the Environment Agency) on 1 May 2011, the LLWR's 2011 Environmental Safety Case (ESC). One of the key regulatory requirements is that all aspects of the construction, operation and closure of the disposal facility should be optimised. An optimised Site Development Plan for the repository was developed and produced as part of the ESC. The Site Development Plan covers all aspects of the construction, operation and closure of the disposal facility. This includes the management of past and future disposals, emplacement strategies, design of the disposal vaults, and the closure engineering for the site. The Site Development Plan also covers the period of active institutional control, when disposals at the site have ceased, but it is still under active management, and plans for the long-term sustainable use of the site. We have a practical approach to optimisation based on recorded judgements and realistic assessments of practicable options framed within the demands of UK policy for LLW management and the characteristics the LLWR site and existing elements of the facility. The final performance assessments undertaken for the ESC were based on the Site Development Plan. The ESC will be used as a tool to inform future decision-making concerning the repository design, operation and the acceptance of wastes, as set out in the evolving Site Development Plan. Maintaining the ESC is thus essential to ensure that the Site Development Plan takes account of an up-to-date understanding and analysis of environmental performance, and that the Plan continues to be optimised. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Parallel and interacting stochastic approximation annealing algorithms for global optimisation

We present the parallel and interacting stochastic approximation annealing (PISAA) algorithm, a stochastic simulation procedure for global optimisation, that extends and improves the stochastic approximation annealing (SAA) by using population Monte Carlo ideas. The efficiency of standard SAA algorithm crucially depends on its selfadjusting mechanism which presents stability issues in high dimensional or rugged optimisation problems. The proposed algorithm involves simulating a population of SAA chains that interact each other in a manner that significantly improves the stability of the self-adjusting mechanism and the search for the global optimum in the sampling space, as well as it inherits SAA desired convergence properties when a square-root cooling schedule is used. It can be implemented in parallel computing environments in order to mitigate the computational overhead. As a result, PISAA can address complex optimisation problems that it would be difficult for SAA to satisfactory address. We demonstrate the good performance of the proposed algorithm on challenging applications including Bayesian network learning and protein folding. Our numerical comparisons suggest that PISAA outperforms the simulated annealing, stochastic approximation annealing, and annealing evolutionary stochastic approximation Monte Carlo.

Local trap↗

Cooling load forecasting-based predictive optimisation for chiller plants

Extensive electric power is required to maintain indoor thermal comfort using heating, ventilation and air conditioning (HVAC) systems, of which, water-cooled chiller plants consume more than 50% of the total electric power. To improve energy efficiency, supervisory optimisation control can be adopted. The controlled variables are usually optimised according to instant building cooling load and ambient wet bulb air temperature at regular time intervals. In this way, the energy efficiency of chiller plants has been improved. However, with an inherent assumption that the instant building cooling load and ambient wet bulb temperature remain constant in the coming time interval, the energy efficiency potential has not been fully realised, especially when cooling loads vary suddenly and extremely. To solve this problem, a cooling load forecasting-based predictive optimisation method is proposed. Rather than minimising the instant system power according to the instant building cooling load and ambient wet bulb temperature, the controlled variables are derived to minimise the sum of the instant system power and one-time-step-ahead future system power according to both instant and forecasted future building cooling loads. With this method, the energy efficiency potential of a chiller plant can be further improved without shortening the operation time interval. 80% redundant energy consumption has been reduced for the sample chiller plant; energy can be saved for chiller plants that work for years. The evaluation on the effect of cooling load forecasting accuracy turns out that the more accurate the forecasts are, the more redundant energy consumption can be reduced.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic ( Allium ampeloprasum L.) by liquid chromatography tandem mass spectrometry

Abstract Introduction Giant garlic is a functional food that contains different kinds of bioactive molecules with beneficial effects on chronic noncommunicable diseases like diabetes and cardiovascular conditions. Considering biosynthesis pathways, abundance, and biological activity, alliin and S‐allyl‐cysteine were used as chemical markers of organosulphur compounds present in giant garlic. Objective To establish a chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic by liquid chromatography tandem mass spectrometry (LC–MS/MS). Methodology Samples were blanched (ca. 90°C for 10 min) to inactivate alliinase and γ‐glutamyl transpeptidase enzymes and then freeze‐dried. Chemometric optimisation was performed via response surface methodology based on central composite design (CCD). Organosulphur compound yields were determined applying a validated LC–MS/MS method in multiple reaction monitoring (MRM) mode using the following transitions: for alliin m/z 178 → 74 and for S‐allyl‐cysteine m/z 162 → 41. Results According to CCD results, under constant conditions of pressure (1500 psi) and time (20 min), the optimal conditions for pressurised liquid extraction of alliin and S‐allyl‐cysteine were 70.75 and 68.97% v/v of ethanol in extraction solvent and 76.45 and 98.88°C as extraction temperature, respectively. Multiple response optimisation for the simultaneous extraction of both organosulphur compounds was established via desirability function. Under these conditions, 2.70 ± 0.27 mg g −1 dry weight (DW) of alliin and 2.79 ± 0.22 mg g −1 DW of S‐allyl‐cysteine were extracted. Conclusions These results clearly demonstrated that pressurised liquid extraction is an efficient green technique to extract bioactive organosulphur compounds from giant garlic. Extraction yields were significantly ( p < 0.05) higher than those obtained with conventional ultra‐turrax extraction.

Peterssen‐Fonseca, Darlene↗

Optimisation of confinement in a fusion reactor using a nonlinear turbulence model

We report the confinement of heat in the core of a magnetic fusion reactor is optimised using a multidimensional optimisation algorithm. For the first time in such a study, the loss of heat due to turbulence is modelled at every stage using first-principles nonlinear simulations which accurately capture the turbulent cascade and large-scale zonal flows. The simulations utilise a novel approach, with gyrofluid treatment of the small-scale drift waves and gyrokinetic treatment of the large-scale zonal flows. A simple near-circular equilibrium with standard parameters is chosen as the initial condition. The figure of merit, fusion power per unit volume, is calculated, and then two control parameters, the elongation and triangularity of the outer flux surface, are varied, with the algorithm seeking to optimise the chosen figure of merit. A twofold increase in the plasma power per unit volume is achieved by moving to higher elongation and strongly negative triangularity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗