Engineering PapersSearch

SEARCH · Engineering Papers

Results for “optical performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optical Performance Prediction of the Thirty Meter Telescope after Initial Alignment Using Optical Modeling

We present an estimate of the optical performance of the Thirty Meter Telescope (TMT) after execution of the full telescope alignment plan. The TMT alignment is performed by the Global Metrology System (GMS) and the Alignment and Phasing System (APS). The GMS first measures the locations of the telescope optics and instruments as a function of elevation angle. These initial measurements will be used to adjust the optics positions and build initial elevation look-up tables. Then the telescope is aligned using starlight as the input for the APS at multiple elevation angles. APS measurements are used to refine the telescope alignment to build elevation and temperature dependent look-up tables. Due to the number of degrees of freedom in the telescope (over 10,000), the ability of the primary mirror to correct aberrations on other optics, the tight optical performance requirements and the multiple instrument locations, it is challenging to develop, test and validate these alignment procedures. In this paper, we consider several GMS and APS operational scenarios. We apply the alignment procedures to the model-generated TMT, which consists of various quasi-static errors such as polishing errors, passive supports errors, thermal and gravity deformations and installation position errors. Using an integrated optical model and Monte-Carlo framework, we evaluate the TMT’s aligned states using optical performance metrics at multiple instrument and field of view locations. The optical performance metrics include the Normalized Point Source Sensitivity (PSSN), RMS wavefront error before and after Adaptive Optics (AO) correction, pupil position change, and plate scale distortion.

Rogers, John

Fast Steering Mirror Disturbance Effects on Overall System Optical Performance for the Large Ultraviolet/optical/infrared Surveyor (LUVOIR) Concept Using a Non-Contact Vibration Isolation and Precision Pointing System

As the optical performance requirements of space telescopes get more stringent, the need to analyze all possible error sources early in the mission design becomes critical. One large telescope with tight performance requirements is the Large Ultraviolet / Optical / Infrared Surveyor (LUVOIR) concept. The LUVOIR concept includes a 15-meter-diameter segmented-aperture telescope with a suite of serviceable instruments operating over a range of wavelengths between 100nm to 2.5um. Using an isolation architecture that involves no mechanical contact between the telescope and the host spacecraft structure allows for tighter performance metrics than current space-based telescopes being flown. Because of this separation, the spacecraft disturbances can be greatly reduced and disturbances on the telescope payload contribute more to the optical performance error. A portion of the optical performance error comes from the disturbances generated from the motion of the Fast Steering Mirror (FSM) on the payload. Characterizing the effects of this disturbance gives insight into the specifications on the FSM needed to achieve the tight optical performance requirements of the overall system. Through analysis of the LUVOIR finite element model and linear optical model given a range of input disturbances at the FSM, the optical performance of the telescope and recommendations for FSM specifications can be determined. The LUVOIR observatory control strategy consists of a multi-loop control architecture including the spacecraft Attitude Control System (ACS), Vibration Isolation and Precision Pointing System (VIPPS), and FSM. This paper focuses on the control loop containing the FSM disturbances and their effects on the telescope optical performance.

Sacks, Lia W.

Structural, Thermal, and Optical Performance (STOP) Modeling and Results for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope includes the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. We performed extensive structural, thermal, and optical performance(STOP) modeling in support of all phases of ISIM development. In this paper, we focus on modeling and results associated with test and verification. ISIMs test program is bound by ground environments, mostly notably the 1g and test chamber thermal environments. This paper describes STOP modeling used to predict ISIM system performance in 0g and at various on-orbit temperature environments. The predictions are used to project results obtained during testing to on-orbit performance.

structural

Optical Performance Modeling for NASA's James Webb Space Telescope

Optical performance modeling for NASA's James Webb Space Telescope is discussed. Alignment drifts, line-of-sight image motion, wavefront sensing, and detector noise are considered in a single model environment for evaluating the predicted performance of the observatory. Parametric sensitivity analyses are performed, and examples presented.

Howard, Joseph M.

Development and Implementation of a Generic Analysis Template for Structural-Thermal-Optical-Performance Modeling

Performance-related effects of system level temperature changes can be a key consideration in the design of many types of optical instruments. This is especially true for space-based imagers, which may require complex thermal control systems to maintain alignment of the optical components. Structural-Thermal-Optical-Performance (STOP) analysis is a multi-disciplinary process that can be used to assess the performance of these optical systems when subjected to the expected design environment. This type of analysis can be very time consuming, which makes it difficult to use as a trade study tool early in the project life cycle. In many cases, only one or two iterations can be performed over the course of a project. This limits the design space to best practices since it may be too difficult, or take too long, to test new concepts analytically. In order to overcome this challenge, automation, and a standard procedure for performing these studies is essential. A methodology was developed within the framework of the Comet software tool that captures the basic inputs, outputs, and processes used in most STOP analyses. This resulted in a generic, reusable analysis template that can be used for design trades for a variety of optical systems. The template captures much of the upfront setup such as meshing, boundary conditions, data transfer, naming conventions, and post-processing, and therefore saves time for each subsequent project. A description of the methodology and the analysis template is presented, and results are described for a simple telescope optical system.

Scola, Salvatore

Magnetic bearings for a high-performance optical disk buffer, volume 2

The operating instructions for the magnetic bearings of a high-performance optical disk buffer are provided. Among the topics that are discussed are the following: front panel layout, turn-on procedure, shut-down procedure, and latch-up protection. Additionally, comprehensive engineering drawings are presented for the design.

Source record

Structural-Thermal-Optical-Performance (STOP) Model Development and Analysis of a Field-widened Michelson Interferometer

An integrated Structural-Thermal-Optical-Performance (STOP) model was developed for a field-widened Michelson interferometer which is being built and tested for the High Spectral Resolution Lidar (HSRL) project at NASA Langley Research Center (LaRC). The performance of the interferometer is highly sensitive to thermal expansion, changes in refractive index with temperature, temperature gradients, and deformation due to mounting stresses. Hand calculations can only predict system performance for uniform temperature changes, under the assumption that coefficient of thermal expansion (CTE) mismatch effects are negligible. An integrated STOP model was developed to investigate the effects of design modifications on the performance of the interferometer in detail, including CTE mismatch, and other three- dimensional effects. The model will be used to improve the design for a future spaceflight version of the interferometer. The STOP model was developed using the Comet SimApp'TM' Authoring Workspace which performs automated integration between Pro-Engineer®, Thermal Desktop®, MSC Nastran'TM', SigFit'TM', Code V'TM', and MATLAB®. This is the first flight project for which LaRC has utilized Comet, and it allows a larger trade space to be studied in a shorter time than would be possible in a traditional STOP analysis. This paper describes the development of the STOP model, presents a comparison of STOP results for simple cases with hand calculations, and presents results of the correlation effort to bench-top testing of the interferometer. A trade study conducted with the STOP model which demonstrates a few simple design changes that can improve the performance seen in the lab is also presented.

Scola, Salvatore J.

Cryogenic Optical Performance of the Cassini Composite InfraRed Spectrometer (CIRS) Flight Telescope

The CIRS half-meter diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out of house and then assembled, aligned and tested upon receipt at GSFC. A 24 inch aperture cryogenic test facility utilizing a 1024 x 1024 CCD array was developed at GSFC specifically for this test. The telescope,s image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the cold image performance requirement of 80% encircled energy within a 460 micron diameter circle.

Losch, Patricia

Cryogenic Optical Performance of the Cassini Composite Infrared Spectrometer (CIRS) Flight Telescope

The CIRS half-meter diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out of house and then assembled, aligned and tested upon receipt at GSFC. A 24 inch aperture cryogenic test facility utilizing a 1024 x 1024 CCD array was developed at GSFC specifically for this test. The telescope's image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the image performance requirement of 80% encircled energy within a 432 microns diameter circle.

Losch, Patricia

Optical performance of synthetic aperture telescope configurations

The diffraction-limited performances of synthetic aperture configuration arrays of four telescopes, used for coherent imaging or beam transmission, are calculated and compared. The optical performance of phased telescope arrays was found to be more sensitive to rms piston errors than to rms tilt errors. Image degradation due to pupil mapping errors imposes tight tolerances upon the structural integrity of the telescope. One part in 10,000 pupil mapping error limits the field-of-view to approximately 30 arcsec. Field curvature of the independent telescopes provides a fundamental limit to the field-of-view for phased arrays made up of two-mirror telescopes. These field-of-view limitations may profoundly affect target acquisition, tracking, or imaging applications.

Harvey, J. E.

Effects of low earth orbit on the optical performance of multi-layer enhanced high reflectance mirrors

Two mirror designs developed for space applications were flown along with a standard mid-infrared design on the leading and trailing edges of the Long Duration Exposure Facility (LDEF). Preliminary observations of induced changes in optical performance of ZnS-coated mirrors and impact-related microstructural and microchemical effects are described in the proceedings of the First LDEF Post-Retrieval Symposium. In this paper, effects of the induced environment and meteoroid/debris impacts on mirror performance are described in more detail. Also, an analysis of reflectance spectra using the results of Auger and secondary ion mass spectroscopy (SIMS) profiling measurements are used to identify an optical-degradation mechanism for the ZnS-coated mirrors. Structural damage associated with a high-velocity impact on a (Si/Al2O3)-coated mirror was imaged optically and with scanning electron and atomic force microscopy (SEM and AFM). Scanning Auger and SIMS analysis provided chemical mapping of selected impact sites. The impact data suggest design and fabrication modifications for obtaining improved mechanical performance using a design variation identified in preflight laboratory simulations. Auger surface profile and SIMS imaging data verified the conclusion that secondary impacts are the source of contamination associated with the dendrites grown on the leading-edge ZnS-coated test samples. It was also found that dendrites can be grown in the laboratory by irradiating contaminated sites on a trailing-edge ZnS-coated sample with a rastered electron beam. These results suggest a mechanism for dendrite growth.

Donovan, Terence

Structural-Thermal-Optical-Performance (STOP) Analysis

The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Spaceflight Center (GSFC) Thermal Engineering Branch (Code 545). A STOP analysis is a multidiscipline analysis, consisting of Structural, Thermal and Optical Performance Analyses, that is performed for all space flight instruments and satellites. This course will explain the different parts of performing this analysis. The student will learn how to effectively interact with each discipline in order to accurately obtain the system analysis results.

Optical

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.

The on-orbit optical performance of STIS

The Space Telescope Imaging Spectrograph (STIS) is a versatile, general purpose instrument installed aboard the Hubble Space Telescope in February, 1997. During the following Servicing Mission Orbital Verification (SMOV) period, STIS has been made operational and aligned, and initial checkout and calibration completed. The overall optical performance goals have largely been achieved and a summary of these results is presented.

Bowers, Charles W.

Measured optical performance of three Fabry-Perot interferometers for use in a tunable ultraviolet filter

A narrowband ultraviolet (UV) filter would allow the first monochromatic two-dimensional images of astrophysical plasmas to be obtained in UV emission lines. The high etendue and spectral resolving power of the Fabry-Perot (FP) interferometer make it an excellent candidate for use in a tunable UV filter, provided that adequate optical performance can be obtained. Laboratory measurements of three UV FP interferometers with progressively greater dielectric mirror reflectances are described. The measurements demonstrate the adequate reflectivity, absorption, and small-scale smoothness of currently available coatings and substrates for UV interferometry. The measurements are conducted at 228.8 nm utilizing a cadmium hollow cathode light source. The best performing interferometer has a finesse of 41 and maximum transmittance of 0.38 over a coating-performance-dominated 3-mm-diam subaperture and a finesse of 26 and maximum transmittance of 0.32 over a parabolic-defect-dominated 30-mm-diam aperture. This interferometer is well suited for use in a UV filter system.

Korendyke, Clarence M.

Video Guidance Sensor: Optical Performance Predictions and Results from STS-95 Experiment

The Video Guidance Sensor is a key component of NASA's Automated Rendezvous & Capture Program. The Video Guidance Sensor Uses laser illumination of a passive target in the field of view of an on-board camera and signal processor to determine the relative position and attitude between the target and sensor. The Video Guidance Sensor flew on space shuttle mission STS-95 in November of 1998 and was a marked success. Comparisons of experimental results from that mission and theoretical models predicting the optical performance will be discussed.

Jackson, John L.