Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

High Throughput Coefficient Thermal Expansion Testing Utilizing Digital Image Correlation

Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.

36 MATERIALS SCIENCE↗