Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved method of optical design

Optical system designed by third order aberration theory is significantly improved by placing it into a ray deviation design program composed of two distinct computer programs. Tests were conducted on telescope systems, an ultraviolet relay lens, and a four lens corrector system.

Howell, B. J.↗

Compressive sensing optical design and simulation tool

A system or method for designing optical systems includes generating a mathematical model of an imaging system; tracing a plurality of light rays from a source through the model of the imaging system in a forward direction and a backward direction incident upon an arbitrarily defined detector location; calculating the total light rays incident upon the arbitrarily defined detector location in response to the plurality of light rays; tracing a series of calibration images first through the computational or compressive imager mathematical model; measuring an output set of parameters based on a plurality of detected rays calibration images at the defined detector location; storing the output set of parameters in software, and determining an estimated system transfer function.

42 ENGINEERING↗

New Worlds Observer Telescope and Instrument Optical Design Concepts

Optical design concepts for the telescope and instrumentation for NASA's New Worlds Observer program are presented. First order parameters are derived from the science requirements, and estimated performance metrics are shown using optical models. A four meter multiple channel telescope is discussed, as well as a suite of science instrument concepts. Wide field instrumentation (imager and spectrograph) would be accommodated by a three-mirror anastigmat telescope design. Planet finding and characterization would use a separate channel which is picked off after the first two mirrors (primary and secondary). Guiding concepts are also discussed.

Howard, Joseph↗

New Worlds Observer Telescope and Instrument Optical Design Concepts

Optical design concepts for the telescope and instrumentation for NASA s New Worlds Observer program are presented. A four-meter multiple channel telescope is discussed, as well as a suite of science instrument concepts. Wide field instrumentation (imager and spectrograph) would be accommodated by a three-mirror-anastigmat telescope design. Planet finding and characterization, and a UV instrument would use a separate channel that is picked off after the first two mirrors (primary and secondary). Guiding concepts are also discussed.

Howard, Joseph M.↗

Proton and electron RLA optics design

We describe optics designs of the key components of proton and electron Recirculating Linear Accelerators (RLAs). They are presented in the context of a high-power hadron accelerator being considered at ORNL and a CEBAF electron energy doubling study, FFA@CEBAF, being developed at Jefferson Lab. Both concepts rely on the Fixed-Field Alternating gradient (FFA) arc optics designs where multiple beam passes are transported by a single beam line. Some of the main challenges of the optics design are in synchronization and orbital and linear optics match of the individual passes with the linac straight. To minimize the complexity of the matching sections and make them more practical, it is preferable to complete as much of the orbital and optical match as possible within a single beam line using the FFA approach. The adiabatic matching technique proposed earlier is one such solution, but it requires a large number of cells. We present a much shorter matching section design based on another approach. A compact dog-leg-type section of several bending dipoles and quadrupoles is used to suppress the orbital offset and dispersion coming out of a periodic cell. Additional quadrupoles are used in the section to keep the beta functions under control and simplify their subsequent match to the linac. Initial beam tracking results are presented.

Benesch, J.↗

Optical Design of an Optical Communications Terminal

An optical communications terminal (OCT) is being developed to enable transmission of data at a rate as high as 2.5 Gb/s, from an aircraft or spacecraft to a ground station. In addition to transmitting high data rates, OCT will also be capable of bidirectional communications.

Biswas, Abhijit↗

Baseline Optical Design for an Integrated Radio and Optical Communication System

This document outlines the baseline optical design for an Integrated Radio and Optical communication (iROC) system, specifically the version labeled in-house as Lunar R1.2a. The version number corresponds to the particular design iteration, including major and minor changes that have been made throughout the design process. The catadioptric design is based on a reflective Cassegrain telescope configuration united with refractive tertiary components in order to approach a diffraction limited, laser beam expander communication transmitter. The configuration presented is intended to be used as an optical transmitter only. Optical design parameters, far-field beam propagations, optical component sensitivity studies, and design explorations are included to provide a high-level understanding of the beam expander’s basic design requirements and optical performance.

optics↗

The University of Colorado OSO-8 spectrometer experiment. I - Introduction and optical design considerations

The optical design of the high-resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200-2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 arcsec normal to the direction of the slit and is selectable from about 3 arcsec to 15 arcmin along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer.

Bruner, E. C., Jr.↗

Telescope simulators for Hubble - An overview of optical designs

This paper briefly describes optical design of the Hubble Space Telescope (HST) and overviews three optical design simulators for HST which have been proposed for use as verification tools to characterize the performance of second-generation instruments during ground testing. These simulators are: the Refractive Aberrated Simulator developed at Ball Aerospace, the Optical Simulator developed at Laboratoire Astronomie Spatiale, and the Jet Propulsion Laboratory Stimulus. Relative advantages and disadvantages of each optical configuration are discussed.

Davilla, Pam↗

PRISM Spectrograph Optical Design

The objective of this contract is to explore optical design concepts for the PRISM spectrograph and produce a preliminary optical design. An exciting optical configuration has been developed which will allow both wavelength bands to be imaged onto the same detector array. At present the optical design is only partially complete because PRISM will require a fairly elaborate optical system to meet its specification for throughput (area*solid angle). The most complex part of the design, the spectrograph camera, is complete, providing proof of principle that a feasible design is attainable. This camera requires 3 aspheric mirrors to fit inside the 20x60 cm cross-section package. A complete design with reduced throughput (1/9th) has been prepared. The design documents the optical configuration concept. A suitable dispersing prism material, CdTe, has been identified for the prism spectrograph, after a comparison of many materials.

Chipman, Russell A.↗

Optical Design of Telescopes and other Reflective Systems using SLIDERS

Optical design tools are presented to provide automatic generation of reflective optical systems for design studies and educational use. The tools are graphical in nature and use an interactive slider interface with freely available optical design software, OSLO EDU. Operation of the sliders provides input to adjust first-order and other system parameters (e.g. focal length), while appropriate system construction parameters are automatically updated to correct aberrations. Graphical output is also presented in real-time (e.g. a lens drawing) to provide the opportunity for a truly visual approach to optical design. Available systems include two- three- and four-mirror telescopes, relays, and afocal systems, either rotationally symmetric or having just a plane of symmetry. Demonstrations are presented, including a brief discussion of interfacing optical design software to MATLAB, and general research opportunities at NASA.

Howard, Joseph M.↗

Update on Integrated Optical Design Analyzer

Updated information on the Integrated Optical Design Analyzer (IODA) computer program has become available. IODA was described in Software for Multidisciplinary Concurrent Optical Design (MFS-31452), NASA Tech Briefs, Vol. 25, No. 10 (October 2001), page 8a. To recapitulate: IODA facilitates multidisciplinary concurrent engineering of highly precise optical instruments. The architecture of IODA was developed by reviewing design processes and software in an effort to automate design procedures. IODA significantly reduces design iteration cycle time and eliminates many potential sources of error. IODA integrates the modeling efforts of a team of experts in different disciplines (e.g., optics, structural analysis, and heat transfer) working at different locations and provides seamless fusion of data among thermal, structural, and optical models used to design an instrument. IODA is compatible with data files generated by the NASTRAN structural-analysis program and the Code V (Registered Trademark) optical-analysis program, and can be used to couple analyses performed by these two programs. IODA supports multiple-load-case analysis for quickly accomplishing trade studies. IODA can also model the transient response of an instrument under the influence of dynamic loads and disturbances.

Moore, James D., Jr.↗

Computational Ion Optics Design Evaluations

Ion optics computational models are invaluable tools in the design of ion optics systems. In this study a new computational model developed by an outside vendor for use at the NASA Glenn Research Center (GRC) is presented. This computational model is a gun code that has been modified to model the plasma sheaths both upstream and downstream of the ion optics. The model handles multiple species (e.g. singly and doubly-charged ions) and includes a charge-exchange model to support erosion estimations. The model uses commercially developed solid design and meshing software to allow high flexibility in ion optics geometric configurations. The results from this computational model are applied to the NEXT project to investigate the effects of crossover impingement erosion seen during the 2000-hour wear test.

Malone, Shane P.↗

Optical Design and Signal Processing for Edge Detection

Properly combining optical design with 3-by-3 element mask reduces number of required computations by factor of as much as 100. Spatial and spatial-frequency responses obtained in system of combination of optical design and signal-processing algorithm. Closely approximate difference-of-Gaussian-function response.

Huck, Friedrich O.↗

Folded Optical Design for High Fidelity Atmospheric Emulation With A Spatial Light Modulator

Atmospheric emulators based on spatial light modulators offer the ability to test atmospheric propagation effects on a laser communication component’s performance in the laboratory setting. To create a high-fidelity atmospheric emulator, details of the optical design are key. This paper discusses the optical design choices and refinements that enabled the creation of a system that was verified to recreate multi-layer turbulence with high fidelity up to D/r0 =50. Optical design choices that affect the fidelity discussed in this paper include the characteristics of the input laser, the spatial light modulator, the holograms, the image relay optical components, and the spatial filter. Also included in this paper is a comparison of the chosen folded optical layout to an alternative angled layout.

Atmospheric turbulence↗

Folded Optical Design for High Fidelity Atmospheric Emulation With A Spatial Light Modulator

Atmospheric emulators based on spatial light modulators offer the ability to test atmospheric propagation effects on a laser communication component’s performance in the laboratory setting. To create a high-fidelity atmospheric emulator, details of the optical design are key. This paper discusses the optical design choices and refinements that enabled the creation of a system that was verified to recreate multi-layer turbulence with high fidelity up to D/r 0 =50. Optical design choices that affect the fidelity discussed in this paper include the characteristics of the input laser, the spatial light modulator, the holograms, the image relay optical components, and the spatial filter. Also included in this paper is a comparison of the chosen folded optical layout to an alternative angled layout.

Atmospheric turbulence↗

The current development status of the Orbiting Carbon Observatory (OCO) instrument optical design

The status of the OCO instrument optical design is presented in this paper. The optical bench assembly comprises three cooled grating spectrometers coupled to an all-reflective telescope/relay system. Dichroic beam splitters are used to separate the light from a common telescope into the three spectral bands. The three bore sighted spectrometers allow the total column CO2 absorption path to be corrected for optical path and surface pressure uncertainties, aerosols, and water vapor. The design of the instrument is based on classic flight proven technologies.

global carb↗

Optical Design of the Camera for Transiting Exoplanet Survey Satellite (TESS)

The optical design of the wide field of view refractive camera, 34 degrees diagonal field, for the TESS payload is described. This fast f/1.4 cryogenic camera, operating at -75 C, has no vignetting for maximum light gathering within the size and weight constraints. Four of these cameras capture full frames of star images for photometric searches of planet crossings. The optical design evolution, from the initial Petzval design, took advantage of Forbes aspheres to develop a hybrid design form. This maximized the correction from the two aspherics resulting in a reduction of average spot size by sixty percent in the final design. An external long wavelength pass filter was replaced by an internal filter coating on a lens to save weight, and has been fabricated to meet the specifications. The stray light requirements were met by an extended lens hood baffle design, giving the necessary off-axis attenuation.

CCD↗