Engineering PapersSearch

SEARCH · Engineering Papers

Results for “operations assurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Virtual Power Plant Architecture and Resilient Design

Virtual Power Plants (VPPs) represent a fundamental shift in electric grid operations, aggregating distributed energy resources (DERs) such as solar panels and battery storage to deliver utility-scale grid services traditionally provided by centralized power plants. This report examines the unique architectural, operational, and digital assurance considerations that distinguish VPPs from conventional utility infrastructure as they scale from pilot projects to mainstream deployment across the United States. While VPPs offer significant opportunities for grid modernization and enhanced flexibility, their distributed, multi-stakeholder architecture introduces distinct security challenges that differ fundamentally from traditional generation facilities. The analysis identifies risks in VPP operations, including device-level security gaps, platform vulnerabilities, and communication protocol weaknesses that create expanded attack surfaces compared to centralized power plants. Through examination of real-world incidents and emerging threat patterns, the report demonstrates how some VPPs' reliance on consumer-owned devices, public internet infrastructure, and complex vendor ecosystems require new approaches to digital assurance and operational security. The findings provide practical guidance for utilities, regulators, and aggregators to implement robust security frameworks and operational best practices essential for maintaining grid reliability as VPP deployment accelerates under the Federal Energy Regulatory Commission (FERC) Order 2222 and related regulatory initiatives.

24 - POWER TRANSMISSION AND DISTRIBUTION

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]

Industrial Assessment Center Technical Field Manager

The work to be performed involves managing Industrial Assessment Centers through a portfolio of activities. The core activities to be performed are in the general areas of; quality assurance of IAC operations, enhancement of the student IAC experience, program development for improving assessments and implementing smart manufacturing projects, program outreach to carry assessment successes beyond the program, and program integration with other DOE/manufacturing assistance programs. The IAC Technical Field Management Organization (FMO) works in close collaboration with DOE and provides technical management for the IAC program working under policy guidelines established by DOE.

42 ENGINEERING

Moving from Information Assurance to Functional Assurance with Engineered Controls

Cyber threats to operational technology demand more than traditional IT defenses—they require full-spectrum mission assurance. Cyber-Informed Engineering (CIE) is an approach that embeds engineered controls into system design to ensure critical functions remain safe and reliable, even under attack. Unlike conventional cybersecurity tools, engineered controls act directly on physical processes to prevent unacceptable outcomes such as equipment damage or mission failure. This session will outline the CIE framework and share examples of consequence-based design that deliver true resilience, not just fail-safe behaviors. Attendees will learn how to integrate these principles into the engineering lifecycle to support resilient-by-design architectures and inform emerging standards. This talk sets the stage for the panel discussion on advancing CIE across sectors as digital and physical systems converge.

24 - POWER TRANSMISSION AND DISTRIBUTION

Non-dimensional performance and safety parameters for heat pipes

The use of heat pipes in safety-critical systems such as nuclear microreactors dictates the development of generalized, practical, scalable performance and safety parameters. Traditional dimensional metrics, while informative, lack the universality required for comparative analysis across varying designs and operating regimes. Here, this work introduces a comprehensive set of non-dimensional parameters to characterize heat pipe performance and safety, including capillary performance, effective thermal conductivity, response time, exergetic efficiency, allowable temperature gradients, allowable rate of temperature change, priming coefficients, and factor of safety. A reference heat pipe design representative of microreactor applications was analyzed via the developed parameters using both traditional analytical models and Sockeye simulations under transient and steady-state conditions. Sodium, potassium, and water were evaluated as working fluids to demonstrate the applicability of the framework across a broad temperature range. The proposed non-dimensional parameters effectively captured key thermal-hydraulic behaviors and safety concerns, as was demonstrated via Sockeye simulations. This framework supports the development of design optimization strategies, operational protocols, and safety assurance practices for advanced reactor systems and other high-reliability applications.

42 - ENGINEERING

Relating Measured Component Damage to Assessed Component Reliability in Reliability Integrity Management (RIM)

There is currently no widely agreed detailed general method for licensing a novel plant incorporating novel materials (or materials being deployed in novel environments); in many such situations, there are no directly applicable engineering code cases for decision-makers (including regulators) to rely on. It may be possible to develop an approach to licensing such a plant that is based on the Reliability and Integrity Management (RIM) approach delineated in ASME BPVC Section XI Division 2. NRC Regulatory Guide 1.246, Rev.0, endorses, with conditions, the subject portion of the ASME Code. But that portion of the ASME code is written at a very high level, and there are fundamental technical challenges associated with applying it literally to licensing a real plant. In the RIM approach, applicants need to do the following (among other things): • Allocate target reliabilities to structures, systems, and components (SSCs) that collectively support the top-level plant safety and availability objectives; • Understand failure modes of those SSCs, and the degradation mechanisms that could lead to those failure modes; • Develop and propose a program of surveillances that will identify degradation prior to failure of SSCs; • Provide a means of reporting results, taking actions for anomalous or undesirable conditions, and give the regulator assurance of continued safe operations. Applying RIM in a specific case will call for advances in the state of practice of relating physical observables to functional reliability of certain component types. Except where a given level of damage corresponds to a failed (or nearly failed) state, it is not practical to establish a precise quantitative relationship between physical observables and reliability. This paper focuses on managing risk of passive component failures based on observable damage parameters. A simple approach to cumulative damage modeling will be illustrated with a view to possible use in RIM applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Cyber Halo Innovation Research Program (CHIRP) Student Research Report: Program Analysis

The Cybersecurity and Space Systems Research Program (CHIRP) conducted multi-year, mission-focused research addressing emerging cybersecurity challenges affecting space and ground systems. Students from California State University San Bernardino (CSUSB), University of Texas El Paso (UTEP), and California State University Dominguez Hills (CSUDH) conducted structured research, developed proof-of-concept demonstrations, participated in applied cybersecurity training, and collaborated with Space Systems Command (SSC), academic, and industry partners. This report documents the research questions, methodologies, findings, demonstrations, and student contributions associated with each cohort. It also summarizes the program’s workforce-development outcomes, including applied cybersecurity training, professional certifications, technical credentials, and partnerships with organizations such as CT Cubed, Inc. and ISC2. Collectively, CHIRP strengthened the space-cybersecurity workforce pipeline and produced research and prototype efforts that may inform future cybersecurity assessments, test and evaluation activities, cyber-range development, acquisition planning, operational training, and mission-assurance initiatives.

McKenzie, Penny L.

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN

Performance Validation of Endcap Timing Layer Detector Modules for CMS Phase-2 Upgrade

The High-Luminosity Large Hadron Collider (HL-LHC) will operate up to 200 simultaneous collisions per bunch crossing, which is a significant jump from the current value of about 30 collisions per bunch crossing, producing significant pileup that challenges accurate event reconstruction. To address this, the Compact Muon Solenoid (CMS) experiment is implementing the Endcap Timing Layer (ETL), a precision timing detector designed to provide timing measurements with a resolution of approximately 50 ps per hit and 35 ps per reconstructed track. This project focuses on the characterization and validation of ETL detector modules using laboratory laser test data. ETL performance is evaluated by analyzing key quantities such as Bunch Crossing Identification (BCID), Time-of-Arrival (TOA), Time-over-Threshold (TOT), Noise Stability etc. The resulting analysis provides insight into the timing performance and operational stability of ETL modules, contributing to the quality assurance process req uired before their installation in the CMS experiment and ensure that the modules can meet the long-term reliability requirements of approximately 10 years of operation without replacement.

Chipara, Munashe [Fermilab]

Long-term measurements of ice nucleating particles at Atmospheric Radiation Measurement (ARM) sites worldwide

Ice nucleating particles (INPs) play a critical role in cloud microphysics and precipitation formation, yet long-term, spatially extensive observational datasets remain limited. Here, we present one of the most comprehensive publicly available datasets of immersion-mode INP concentrations using a single analytical method, generated through the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) user facility. INP filter samples have been collected across a broad range of environments – including agricultural plains, Arctic coastlines, high-elevation mountain sites, marine regions, and urban areas – via fixed observatories, mobile facility deployments, and vertically-resolved tethered balloon system operations. We describe the standardized processing and quality assurance pipeline, from filter collection and processing using the Ice Nucleation Spectrometer to final data products archived on the ARM Data Discovery portal. The dataset includes both total INP concentrations and selectively treated samples, allowing for classification of biological, organic, and inorganic INP types. It features a continuous 5-year record of INP measurements from a central U.S. site, with data collection still ongoing. Seasonal and site-specific differences in INP concentrations are illustrated through intercomparisons at −10 and −20 °C, revealing distinct regional sources and atmospheric drivers. We also outline mechanisms for researchers to access existing data, request additional sample analyses, and propose future field campaigns involving ARM INP measurements. This dataset supports a wide range of scientific applications, from observational and mechanistic studies to model development, and provides critical constraints on aerosol-cloud interactions across diverse atmospheric regimes (Creamean et al., 2024, 2020b; https://doi.org/10.5439/1770816).

Creamean, Jessie M. [Colorado State Univ., Fort Co

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION

Annual Status Report (FY 2024): Performance Assessment for the Integrated Disposal Facility

The purpose of this Annual Summary Report (ASR) for Fiscal Year (FY) 2024 is to evaluate the continued adequacy of the Integrated Disposal Facility (IDF) Performance Assessment (PA) and Disposal Authorization Statement (DAS). This report consolidates relevant monitoring data, modeling analyses, and regulatory reviews to demonstrate a reasonable expectation that the PA objectives and performance measures will be met, as required under DOE O 435.1. The ASR follows the guidance in DOE-STD-5002-2017, which provides a framework for maintaining the validity of the DAS through periodic assessment of facility performance and compliance with waste disposal requirements. The IDF is a near-surface disposal facility designed to receive and permanently dispose of low-level waste (LLW) and mixed low-level waste (MLLW) generated from Hanford Site operations. The facility consists of two double-lined disposal cells equipped with leak detection and leachates recovery systems to ensure environmental protection. Waste planned for disposal includes vitrified low-activity waste (LAW) and solid secondary waste (SSW) from the Hanford Waste Treatment and Immobilization Plant (WTP). At the end of FY 2024, the IDF had not yet received any waste, as it remains in a pre-operational state. Disposal activities will begin with the hot commissioning of the WTP LAW Vitrification Facility using the Direct-Feed Low-Activity Waste (DFLAW) approach in Calendar Year (CY) 2025. This ASR justifies the continued adequacy of the PA and DAS by reviewing key documents and data sources. these sources are listed in Table A-2 in Appendix A.4): The Operating Disposal Authorization Statement (ODAS) for the IDF (DOE-EM, 2021) remains in effect, with no outstanding conditions or key issues affecting its implementation. Based on the comprehensive review of PA analyses, monitoring data, and regulatory compliance activities, this ASR concludes that the IDF remains in compliance with DOE O 435.1, and there is reasonable assurance that the PA performance objectives will be met once disposal operations commence in CY 2025.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Lifetime study of the ColdADC for the Deep Underground Neutrino Experiment

ColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far Detector complex, which will consist of four liquid argon time projection chambers. Each contains 17 kilotons liquid argon as the target material in order to measure neutrino oscillations. Approximately 40,000 ColdADC ASICs will be installed for DUNE in the first two large detectors and will be operated at cryogenic temperatures during the experiment without replacement. The lifetime of the ColdADC is a critical parameter affecting the data quality and physics sensitivity of the experiment. A measurement of the lifetime of the ColdADC was carried out, and the results shown in this paper assure orders of magnitude longer lifetime of the ColdADC than the planned operation time of the detectors.

Front-end electronics for detector readout

National Solar Thermal Test Facility: Operations & Maintenance Report

The NSTTF O&M Project continues the operation and maintenance activities of the existing critical capabilities and infrastructure at the NSTTF. This project is to support and assure the success of Solar Heat for Industrial Process in the United States and the larger global community by ensuring the NSTTF is a safe and operational facility. The primary goal of this project will be to maintain the solar tower and heliostat field while also allowing NSTTF staff to improve processes for operations and maintenance. This includes expanding our preventative maintenance program, inventory systems, and our data sharing capabilities. Additionally, this will support an outreach program with regular seminars, sharing of data, and the release of open-source software to support heliostat metrology

14 SOLAR ENERGY

Field Insights: Strengthening Digital Assurance Through On-Site Network Monitoring

The accelerating deployment of digital energy infrastructure, ranging from inverter-based resources (IBRs), battery energy storage systems (BESS), to advanced grid control platforms, has brought unprecedented visibility, flexibility, and efficiency to the electric grid. However, this digital transformation also introduces new cybersecurity challenges, particularly in the form of supply chain risks and operational blind spots at the grid edge. Over the past year, the Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through its Rapid Risk Assessment initiative, along with the Grid Deployment Office (GDO), through its Technical Assistance for Digital Assurance (TADA) initiative, have supported a series of on-site network engagements led by Idaho National Laboratory (INL). These engagements, conducted in partnership with asset owners across the country, have focused on identifying real-world vulnerabilities and misconfigurations in operational environments, many of which are not detectable through remote assessments or traditional compliance audits. The goal of this report is to distill key findings and lessons learned during network hunt engagements from INL’s fiscal year (FY) 2024 - 2025. It is intended to help asset owners—regardless of their participation in the program—better understand the evolving threat landscape and adopt practical measures to secure their digital energy infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING