Solar tests of aperture plate materials for solar thermal dish collectors

In parabolic dish solar collectors, walk-off of the spot of concentrated sunlight is a hazard if a malfunction causes the concentrator to stop following the Sun. Therefore, a test program was carried out to evaluate the behavior of various ceramics, metals, and polymers under solar irradiation of about 7000 kW/sq m. (peak) for 15 minutes. The only materials that did not slump or shatter were two grades of medium-grain extruded graphite. High purity, slip-cast silica might be satisfactory at somewhat lower flux. Oxidation of the graphite appeared acceptable during tests simulating walk-off, acquisition (2000 cycles on/off Sun), and spillage (continuous on-Sun operation).

Jaffe, L. D.↗

High Performance Thermal Switch for Lunar and Planetary Surface Extreme Environments

This paper describes a high performance thermal switch for lunar/planetary extreme environments. This device has been given the name Reverse-Operation DTE Thermal Switch (or ROD-TSW). Two different prototypes were designed, built, and tested. Their basis of operation is the mating/de-mating of parallel flat metal surfaces driven by the differential thermal expansion (DTE) between mid-to-high CTE metal/polymer or metal-only end-pieces and a low CTE, low thermal conductivity (k) metal/polymer support rod. The requirements were to be fully ON above 300 K and fully OFF below 260 K. A series of four tests were carried out to verify/qualify the prototypes. In the first (non-vacuum) test, the thermal switches were cooled with freeze-spray and the non-conductive rod in the OFF thermal path allowed electrical resistance to confirm the 273 K as-designed ON/OFF actuation temperature. In the second (vacuum) test, a calibrated Q-meter was used, which indicated 5 W/K ON, 0.002 W/K OFF conductance (2500:1 ON/OFF ratio). To increase readiness to TRL6, a vibration test with pre/post thermal cycling followed by a 36-day test in a relevant environment were also carried out. This paper describes the development program and on-going related work at JPL.

Bugby, David C↗

High Performance Thermal Switch for Lunar and Planetary Surface Extreme Environments

This paper describes a high performance thermal switch for lunar/planetary extreme environments. This device has been given the name Reverse-Operation DTE Thermal Switch (or ROD-TSW). Two different prototypes were designed, built, and tested. Their basis of operation is the mating/de-mating of parallel flat metal surfaces driven by the differential thermal expansion (DTE) between mid-to-high CTE metal/polymer or metal-only end-pieces and a low CTE, low thermal conductivity (k) metal/polymer support rod. The requirements were to be fully ON above 300 K and fully OFF below 260 K. A series of four tests were carried out to verify/qualify the prototypes. In the first (non-vacuum) test, the thermal switches were cooled with freeze-spray and the non-conductive rod in the OFF thermal path allowed electrical resistance to confirm the 273 K as-designed ON/OFF actuation temperature. In the second (vacuum) test, a calibrated Q-meter was used, which indicated 5 W/K ON, 0.002 W/K OFF conductance (2500:1 ON/OFF ratio). To increase readiness to TRL6, a vibration test with pre/post thermal cycling followed by a 36-day test in a relevant environment were also carried out. This paper describes the development program and on-going related work at JPL.

Bugby, David C.↗

Fire safety experiments on MIR Orbital Station

The process of heterogeneous combustion of most materials under zero-g without forced motion of air is practically impossible. However, ventilation is required to support astronauts' life and cool equipment. The presence of ventilation flows in station compartments at accidental ignition can cause a fire. An additional, but exceedingly important parameter of the fire risk of solid materials under zero-g is the minimum air gas velocity at which the extinction of materials occurs. Therefore, the conception of fire safety can be based on temporarily lowering the intensity of ventilation and even turning it off. The information on the limiting conditions of combustion under natural conditions is needed from both scientific and practical points of view. It will enable us to judge the reliability of results of ground-based investigations and develop a conception of fire safety of inhabited sealed compartments of space stations to by provided be means of nontraditional and highly-effective methods without both employing large quantities of fire-extinguishing compounds and hard restrictions on use of polymers. In this connection, an experimental installation was created to study the process of heterogeneous combustion of solid non-metals and to determine the conditions of its extinction under microgravity. This installation was delivered to the orbital station 'Mir' and the cosmonauts Viktorenko and Kondakova performed initial experiments on it in late 1994. The experimental installation consists of a combustion chamber with an electrical systems for ignition of samples, a device for cleaning air from combustion products, an air suction unit, air pipes and a control panel. The whole experiment is controlled by telemetry and recorded with two video cameras located at two different places. Besides the picture, parameters are recorded to determine the velocity of the air flow incoming to the samples, the time points of switching on/off the devices, etc. The combustion chamber temperature is also controlled. The main objectives of experiments of this series were as follows: (1) verification of the reliability of the installation in orbital flight; (2) verification of the experimental procedure; and (3) investigation of combustion of two types of materials under microgravity at various velocities of the incoming air flow.

Egorov, S. D.↗

Submicrosecond Power-Switching Test Circuit

A circuit that changes an electrical load in a switching time shorter than 0.3 microsecond has been devised. This circuit can be used in testing the regulation characteristics of power-supply circuits . especially switching power-converter circuits that are supposed to be able to provide acceptably high degrees of regulation in response to rapid load transients. The combination of this power-switching circuit and a known passive constant load could be an attractive alternative to a typical commercially available load-bank circuit that can be made to operate in nominal constant-voltage, constant-current, and constant-resistance modes. The switching provided by a typical commercial load-bank circuit in the constant-resistance mode is not fast enough for testing of regulation in response to load transients. Moreover, some test engineers do not trust the test results obtained when using commercial load-bank circuits because the dynamic responses of those circuits are, variously, partly unknown and/or excessively complex. In contrast, the combination of this circuit and a passive constant load offers both rapid switching and known (or at least better known) load dynamics. The power-switching circuit (see figure) includes a signal-input section, a wide-hysteresis Schmitt trigger that prevents false triggering in the event of switch-contact bounce, a dual-bipolar-transistor power stage that drives the gate of a metal oxide semiconductor field-effect transistor (MOSFET), and the MOSFET, which is the output device that performs the switching of the load. The MOSFET in the specific version of the circuit shown in the figure is rated to stand off a potential of 100 V in the "off" state and to pass a current of 20 A in the "on" state. The switching time of this circuit (the characteristic time of rise or fall of the potential at the drain of the MOSFET) is .300 ns. The circuit can accept any of three control inputs . which one depending on the test that one seeks to perform: a repetitive waveform from a signal generator, momentary closure of a push-button switch, or closure or opening of a manually operated on/off switch. In the case of a signal generator, one can adjust the frequency and duty cycle as needed to obtain the desired AC power-supply response, which one could display on an oscilloscope. Momentary switch closure could be useful for obtaining (and, if desired, displaying on an oscilloscope set to trigger on an event) the response of a power supply to a single load transient. The on/off switch can be used to switch between load states in which static-load regulation measurements are performed.

Folk, Eric N.↗