Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “old devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Legacy Devices and Interoperability: Developing a Scientific Strategy for Inclusion and Representation of Older Devices

Legacy devices across grid, transportation, and building systems present complex modernization challenges that extend far beyond simple equipment obsolescence. Pulling from presentations and break-out group discussions from this workshop on legacy devices across all three sectors, this report examines the interconnected factors driving replacement decisions, documents successful modernization initiatives from recent years, and provides strategic guidance for coordinating infrastructure transformation across these critical sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecular coupling competing with defects within insulator of the magnetic tunnel junction-based molecular spintronics devices

Nearly 70 years old dream of incorporating molecule as the device element is still challenged by competing defects in almost every experimentally tested molecular device approach. This paper focuses on the magnetic tunnel junction (MTJ) based molecular spintronics device (MTJMSD) method. An MTJMSD utilizes a tunnel barrier to ensure a robust and mass-producible physical gap between two ferromagnetic electrodes. MTJMSD approach may benefit from MTJ's industrial practices; however, the MTJMSD approach still needs to overcome additional challenges arising from the inclusion of magnetic molecules in conjunction with competing defects. Molecular device channels are covalently bonded between two ferromagnets across the insulating barrier. An insulating barrier may possess a variety of potential defects arising during the fabrication or operational phase. This paper describes an experimental and theoretical study of molecular coupling between ferromagnets in the presence of the competing coupling via an insulating tunnel barrier. We discuss the experimental observations of hillocks and pinhole-type defects producing inter-layer coupling that compete with molecular device elements. We performed theoretical simulations to encompass a wide range of competition between molecules and defects. Monte Carlo Simulation (MCS) was used for investigating the defect-induced inter-layer coupling on MTJMSD. Our research may help understand and design molecular spintronics devices utilizing various insulating spacers such as aluminum oxide (AlOx) and magnesium oxide (MgO) on a wide range of metal electrodes. This paper intends to provide practical insights for researchers intending to investigate the molecular device properties via the MTJMSD approach and do not have a background in magnetic tunnel junction fabrication.

36 MATERIALS SCIENCE↗

Smart memory buffers

An example method involves receiving, at a first memory node, data to be written at a memory location in the first memory node. The data is received from a device. At the first memory node, old data is read from the memory location, without sending the old data to the device. The data is written to the memory location. The data and the old data are sent from the first memory node to a second memory node to store parity information in the second memory node without the device determining the parity information. The parity information is based on the data stored in the first memory node.

97 MATHEMATICS AND COMPUTING↗

Profile Generation for GPU Targets

GPU accelerators are ubiquitous, but their ecosystem is far less evolved than the host one. Compiler heuristics are often tuned for CPUs and reused for GPU. Similarly, tooling and more evolved optimization techniques are historically not available on GPU targets. In this work, we address one of these shortcomings and enable profile generation and profile-guided optimizations (PGO) for GPU targets. While this is only a single step towards a CPU equivalent ecosystem for offload devices, it shows how old misconceptions on the limitations of GPUs are often not warranted anymore. Through our implementation in LLVM/Offload, we enable device-side PGO for full scientific applications and open up tooling opportunities, including code coverage analysis and compiler-built-in roofline analysis. Our evaluation highlights the performance implications of profile generation, the insights gained from these profiles, and the (missed) opportunities in utilizing the information for GPU compilation.

McDonough, Ethan Luis [Lawrence Livermore National↗

Polarization and domains in wurtzite ferroelectrics: Fundamentals and applications

The 2019 report of ferroelectricity in (Al,Sc)N [Fichtner et al., J. Appl. Phys. 125, 114103 (2019)] broke a long-standing tradition of considering AlN the textbook example of a polar but non-ferroelectric material. Combined with the recent emergence of ferroelectricity in HfO2-based fluorites [Böscke et al., Appl. Phys. Lett. 99, 102903 (2011)], these unexpected discoveries have reinvigorated studies of integrated ferroelectrics, with teams racing to understand the fundamentals and/or deploy these new materials—or, more correctly, attractive new capabilities of old materials—in commercial devices. The five years since the seminal report of ferroelectric (Al,Sc)N [Fichtner et al., J. Appl. Phys. 125, 114103 (2019)] have been particularly exciting, and several aspects of recent advances have already been covered in recent review articles [Jena et al., Jpn. J. Appl. Phys. 58, SC0801 (2019); Wang et al., Appl. Phys. Lett. 124, 150501 (2024); Kim et al., Nat. Nanotechnol. 18, 422–441 (2023); and F. Yang, Adv. Electron. Mater. 11, 2400279 (2024)]. We focus here on how the ferroelectric wurtzites have made the field rethink domain walls and the polarization reversal process—including the very character of spontaneous polarization itself—beyond the classic understanding that was based primarily around perovskite oxides and extended to other chemistries with various caveats. The tetrahedral and highly covalent bonding of AlN along with the correspondingly large bandgap lead to fundamental differences in doping/alloying, defect compensation, and charge distribution when compared to the classic ferroelectric systems; combined with the unipolar symmetry of the wurtzite structure, the result is a class of ferroelectrics that are both familiar and puzzling, with characteristics that seem to be perfectly enabling and simultaneously nonstarters for modern integrated devices. The goal of this review is to (relatively) quickly bring the reader up to speed on the current—at least as of early 2025—understanding of domains and defects in wurtzite ferroelectrics, covering the most relevant work on the fundamental science of these materials as well as some of the most exciting work in early demonstrations of device structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bubble Chamber Detectors with Light Nuclear Targets: A Snowmass 2021 White Paper

Neutrino cross sections are a critical ingredient in experiments that depend on neutrino scattering to reconstruct event kinematics and infer neutrino characteristics, like NOvA and T2K. An opportunity exists to reduce the 5-10% broad uncertainty on neutrino cross sections by producing more measurements of neutrino scattering from light nuclear targets at the relevant energies. Bubble chambers with light nuclear targets would be ideal for these measurements but the most recent device designed for use with an accelerator neutrino source is at least fifty years old. A new bubble chamber with light nuclear targets could be designed by observing how the technology has progressed for use in dark matter experiments and producing smaller modular devices that use more efficient cooling systems. A smaller modular device could also be designed for deployment to all functioning neutrino beams, but an investigation of the proper operating characteristics is necessary to adapt newer detectors to the structure of contemporary neutrino beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of inoculation practices on microbiota assembly and community stability in a fabricated ecosystem

Studying plant-microbe-soil interactions is challenging due to their high complexity and variability in natural ecosystems. While fabricated ecosystems provide opportunities to recapitulate aspects of these systems in reduced complexity and controlled environments, inoculation can be a significant source of variation. To tackle this, we evaluated how different bacteria inoculation practices and plant harvesting time points affect the reproducibility of a microbial synthetic community (SynCom) in association with the model grass Brachypodium distachyon. We tested three microbial inoculation practices: seed inoculation, transplant inoculation, and seedling inoculation; and two harvesting points: early (14-day-old plants) and late (21 days post-inoculation). We grew our plants and bacterial strains in sterile devices (EcoFABs) and characterized the microbial community from root, rhizosphere, and sand using 16S ribosomal RNA gene sequencing. The results showed that inoculation practices significantly affected the rhizosphere microbial community only when harvesting at an early time point but not at the late stage. As the SynCom showed a persistent association with B. distachyon at 21 days post-inoculation regardless of inoculation practices, we assessed the reproducibility of each inoculation method and found that transplant inoculation showed the highest reproducibility. Moreover, plant biomass was not adversely affected by transplant inoculation treatment. We concluded that bacteria inoculation while transplanting coupled with a later harvesting time point gives the most reproducible microbial community in the EcoFAB-B. distachyon-SynCom fabricated ecosystem and recommend this method as a standardized protocol for use with fabricated ecosystem experimental systems.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE↗

Micro-fabricated mirrors with finesse exceeding one million

The Fabry–Perot resonator is one of the most widely used optical devices, enabling scientific and technological breakthroughs in diverse fields including cavity quantum electrodynamics, optical clocks, precision length metrology, and spectroscopy. Though resonator designs vary widely, all high-end applications benefit from mirrors with the lowest loss and highest finesse possible. Fabrication of the highest-finesse mirrors relies on centuries-old mechanical polishing techniques, which offer losses at the parts-per-million (ppm) level. However, no existing fabrication techniques are able to produce high-finesse resonators with the large range of mirror geometries needed for scalable quantum devices and next-generation compact atomic clocks. In this paper, we introduce a scalable approach to fabricate mirrors with ultrahigh finesse ( ≥ <#comment/> 10 6 ) and user-defined radius of curvature spanning of four orders of magnitude ( 10 − <#comment/> 4 − <#comment/> 10 0 m ). We employ photoresist reflow and reactive ion etching to shape and transfer mirror templates onto a substrate while maintaining sub-Angstrom roughness. This substrate is coated with a dielectric stack and used to create arrays of compact Fabry–Perot resonators with finesse values as high as 1.3 million and measured excess loss < <#comment/> 1 p p m . Optical ringdown measurements of 43 devices across five substrates reveal that the fabricated cavity mirrors—with both small and large radii of curvature—produce an average coating-limited finesse of 1.05 million. This versatile approach opens the door to scalable fabrication of high-finesse miniaturized Fabry–Perot cavities needed for emerging quantum optics and frequency metrology technologies.

42 ENGINEERING↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Ocular biological parameters and prevalence of myopia in vocational high school and general high school in China

Significance Higher prevalence of myopia is possibly associated with more extended schooling schedules. Therefore, adjustments to high school curricula may aid in reducing the prevalence of myopia among adolescents. Purpose To investigate the prevalence of myopia among 15- to 18-year-old adolescents in Tianjin, China, and to evaluate the impact of different educational schedules on the prevalence of myopia among high school students. Methods This is a school-based epidemiological study with a cross-sectional design. Ocular biological parameters and noncycloplegic photorefraction were examined using optical biometry devices and photoscreener devices. Each student’s spherical equivalent (SE) and ocular biometry were recorded, and the prevalence of myopia was calculated. Results A total of 2,867 participants (1,519 males and 1,348 females) were tested for non-cycloplegic refraction, axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD) and lens thickness (LT). In this research, the overall prevalence of myopia was 81.6%, with high myopia accounting for 11.8%. Myopia prevalence was substantially higher in general high schools than in vocational high schools, with 86.1 and 70.1%, respectively. There were no significant differences in the prevalence of myopia ( p = 0.744) or high myopia ( p = 0.851) across the three vocational school years. In the general high school, however, there was an increase of 4.6% ( p < 0.05) in myopia prevalence between year 10 and year12. Conclusion Comparing vocational and standard high school students, there are considerable disparities in prevalence of myopia, spherical equivalent, and ocular biological parameters. The prevalence of myopia and high myopia increased among standard high school students, but remained relatively consistent among students in vocational schools.

Liu, Yang↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗

Integrated photonics on thin-film lithium niobate

Lithium niobate (LN), an outstanding and versatile material, has influenced our daily life for decades—from enabling high-speed optical communications that form the backbone of the Internet to realizing radio-frequency filtering used in our cell phones. This half-century-old material is currently embracing a revolution in thin-film LN integrated photonics. The successes of manufacturing wafer-scale, high-quality thin films of LN-on-insulator (LNOI) and breakthroughs in nanofabrication techniques have made high-performance integrated nanophotonic components possible. With rapid development in the past few years, some of these thin-film LN devices, such as optical modulators and nonlinear wavelength converters, have already outperformed their legacy counterparts realized in bulk LN crystals. Furthermore, the nanophotonic integration has enabled ultra-low-loss resonators in LN, which has unlocked many novel applications such as optical frequency combs and quantum transducers. In this review, we cover—from basic principles to the state of the art—the diverse aspects of integrated thin-film LN photonics, including the materials, basic passive components, and various active devices based on electro-optics, all-optical nonlinearities, and acousto-optics. We also identify challenges that this platform is currently facing and point out future opportunities. The field of integrated LNOI photonics is advancing rapidly and poised to make critical impacts on a broad range of applications in communication, signal processing, and quantum information.

Zhu, Di (ORCID:0000000302101860)↗

New value of old knowledge: sulphur-based GaAs surface passivation and potential GaAs application in molecular electronics and spintronics

GaAs is well known for its extremely high electron mobility and direct band gap. Owing to the technological advances in silicon-based technology, GaAs has been limited to niche areas. This paper discusses the application of GaAs in molecular electronics and spintronics as a potential field for considering this amazing but challenging material. GaAs is challenging because its surface is characterized by a high density of surface states, which precludes the utilization of this semiconducting material in mainstream devices. Sulfur(S)-based passivation has been found to be significantly useful for reducing the effect of dangling bonds and was researched thoroughly. GaAs applications in molecular spintronics and electronics can benefit significantly from prior knowledge of GaAs and S interactions because S is a popular functional group for bonding molecular device elements with different semiconductors and metals. In this article, the problem associated with the GaAs surface is discussed in a tutorial form. A wide variety of surface passivation methods has been briefly introduced. We attempted to highlight the significant differences in the S-GaAs interactions for different S passivation methods. We also elaborate on the mechanisms and atomic-scale understanding of the variation in surface chemistry and reconstruction due to various S passivation methods. It is envisioned that GaAs and thiol-terminated molecule-based novel devices can exhibit innovative device characteristics and bring the added advantage of S-based passivation.

36 MATERIALS SCIENCE↗

State preparation of lattice field theories using quantum optimal control

Here, we explore the application of quantum optimal control (QOC) techniques to state preparation of lattice field theories on quantum computers. As a first example, we focus on the Schwinger model, quantum electrodynamics in 1+1 dimensions. We demonstrate that QOC can significantly speed up the ground state preparation compared to gate-based methods, even for models with long-range interactions. Using classical simulations, we explore the dependence on the interqubit coupling strength and the device connectivity, and we study the optimization in the presence of noise. While our simulations indicate potential speedups, the results strongly depend on the device specifications. In addition, we perform exploratory studies on the preparation of thermal states. Our results motivate further studies of QOC techniques in the context of quantum simulations for fundamental physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Illuminating Galaxy Evolution at Cosmic Noon with ISCEA: the Infrared Satellite for Cosmic Evolution Astrophysics

ISCEA (Infrared Satellite for Cosmic Evolution Astrophysics) is a small astrophysics mission whose Science Goal is to discover how galaxies evolved in the cosmic web of dark matter at cosmic noon. Its Science Objective is to determine the history of star formation and its quenching in galaxies as a function of local density and stellar mass when the Universe was 3-5 Gyrs old (1.2 10 Mpc in each of 50 protocluster (cluster and cosmic web) fields at 1.2 < z < 2.1. ISCEA measures the star formation quenching factor in those fields, and galaxy kinematics with a precision < 50 km/s to deduce the 3D spatial distribution in each field. ISCEA will transform our understanding of galaxy evolution at cosmic noon. ISCEA is a small satellite observatory with a 30cm equivalent diameter aperture telescope with a FoV of 0.32 deg^2, and a multi-object spectrograph with a digital micro-mirror device (DMD) as its programmable slit mask. ISCEA will obtain spectra of 1000 galaxies simultaneously at an effective resolving power of R=1000, with 2.8"x2.8" slits, over the NIR wavelength range of 1.1 to 2.0 microns, a regime not accessible from the ground without large gaps in coverage. ISCEA will achieve a pointing accuracy of <= 2" FWHM over 200s. ISCEA will be launched into a Low Earth Orbit, with a prime mission of 2.5 years. ISCEA's space-qualification of DMDs opens a new window for spectroscopy from space, enabling revolutionary advances in astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics

We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feedback from the scientific and medical community to speed the process of review, improvement and possible implementation.

Galbiati, C.↗